Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:

Similar documents
Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:

Capacitive Sensors with a body that is in excellent shape - The 26 Series

M-Sens 2 Application overview. FlowJam application overview. Online moisture measurement for solids. For measuring capillary and surface humidity

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

MICROSENSE FLOW SWITCH

Introduction to Bulk Solids. The Basics

WHG. RoHS. Compliant. Edition February All specifications are subject to change without notice. ( )

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH. Manual Number: LX-SPDT A

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE SWITCH

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

SET-2000 Oil/Sludge 12 VDC

From simple point level controls to advanced computer-based inventory management

ASTRO FF14 FRICTION FEEDER SERVICE MANUAL

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Vacuum Conveying. Industrial Equipment & Design Company....a world of experience in powder handling

Gate Operator. Modfications

FLAKER/DCM SEQUENCE OF OPERATION

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

Instruction Manual Model A

Snifter ATEX22 VERSION. User Manual. Distributor

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Model Number Structure

Operating Instructions. PowerFill. Automatic Granulate Conveyor for perfectmelt SE

One Easy Strategy for Savings, Sustainability, and Productivity

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

FAN POWERED VAV TERMINALS

SET-2000 Hi Level/Oil

Revision date Section Change page(s) Description

RTP9 ROTARY TABLET PRESS USER MANUAL

Filabot EX6 Extruder. Operation Manual. CAUTION! Read Carefully. Filabot Vermont, USA, Earth

Handling Equipment & Dedusting

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

APPLICATIONS > KORUND

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Functional Safety Manual Oil Leak Detector NAR300 System

INSTALLATION INSTRUCTIONS

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Centro-Matic Automated Lubrication Systems System Controls

OilSET-1000 (12 VDC)

Solid biofuel solutions

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

LH 3 Resina Capper Document No. LH3

10 Considerations for Pneumatic Conveying System Design: What Most Engineering Schools Didn t Teach You

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH. Manual Number: LX-DualSP A

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Proper maintenance of tunnel finisher will prolong its life and enable the equipment to produce the best possible quality.

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

Ronan Model X96S Series Weighing System

Catalog Number E57 product family or iprox. Description Tubular inductive proximity sensor

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

C Series Oven Training Program

Volkmann Vacuum Conveying Applications

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

NHR-25 Feed Hopper with Agitator

Infra-Red Transit Heat and Flame Sensors. Early warning fire detection to protect conveyors, product and plant

DTA. Motor thermistor relay. Benefits. Description

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

ORION-FWS. Computer for feed weighing

BOP Management System Information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS

AUTOMATIC BAG SLITTERS. Bag Slitters & Tubular Chain Conveyors EST YEARS

GAS MONITOR Model Model

CleanSpray System Operation

FC-2200 Flame Detector

Instruction Manual. Princo Model L3522. Point Level Controllers with LEVEL SENTRY. Rev 2, June 2013

Conditioning Hoppers. Installation and Electrical Wiring Guide

Refrigeration System with a Capillary Tube and a Thermostat

IR FLAME DETECTOR RIV-601/F

High Output Vacuum/Pressure Pump

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Fluoride. by ProMinent May 2016

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

WINDFERN ROAD HOUSTON, TEXAS D-500 Dry Polymer Make Up System

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Granulators Reprocessing Plastic Scrap into Valuable Regrind. world of innovation

MJC Click to go to the page. MJC Cartridge Filter

Microwave Doppler Flow Switch. Installation & Operation Manual

AO Annunciator Module

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

FlowJam Bulk Flow Detection

Ramsey Motion Monitoring Systems

Phone: Fax :

BEHN+BATES. Information. Inline Valve Bag Filling Machines

Getting Started Quick Reference Guide

Features and Benefits

piflow Conveyor Customer Code

TEMPERATURE & PRESSURE CONTROLS

PELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Transcription:

Description: The Rechner KAS series sensors are ideal for use as level detection devices. The sensors work equally well for liquids, granulates, or powders. When a system is required to replenish a bin or tank when a low level point is reached, a control can be made using 2 sensors and the EGI-RLC-MM power supply logic controller. Function: When the system is installed as shown, the pump or conveyor used to fill the tank or bin will be controlled by the relay in the EGI-RLC-MM. When the level in the tank drops below the min sensor, the relay will energize to start the pump motor. The relay will remain energized until the tank has been filled to the max sensor. At this point, the relay will de-energize and stop the filling process. The relay will remain de-energized until the level drops below the min sensor again. The cycle then repeats to keep the tank filled. Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows: 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the product to be detected. 3. Reset the sensor s sensitivity by turning the potentiometer counter-clockwise 20 full turns, or until the sensor no longer sees the product. 4. Adjust the sensor to the product to be detected by turning the potentiometer clockwise until the sensor sees the product. 5. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees clockwise. Parts Required: 2 Sensors: KAS-80-35-A-M32-Y3-NL 2 5 Meter Cables: 0.25SQX4C 1 Rechner Logic Controller: EGI-RLC-MM

Wiring Diagrams: Max Min

Description: The Rechner KAS series sensors can easily be applied to detect the accumulation of water in the bottom of oil or petroleum product tanks. Since the dielectric constant of petroleum products is considerably lower than water (the dielectric constant of water is 80 and the dielectric constant of petroleum is between 2 and 4) the KAS sensor can be adjusted to detect the water and not the petroleum. Function: The sensor should be mounted at or below the maximum acceptable water accumulation level. When the sensor detects the water, it will energize the relay providing a high water indication or alarm. The KAS sensor is capable of detecting water through glass up to 4mm (5/32 inch) thick. If a sight glass is available at or below the maximum acceptable water accumulation level, installing the sensor to detect through the sight glass eliminates the need to make a mounting hole through the tank. Adjust the sensor to ignore the oil in the tank: 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the oil. 3. Find the switching point of the oil by turning the potentiometer clockwise until the sensor detects the oil. 4. Adjust the sensor to ignore the oil by turning the potentiometer counter-clockwise until the sensor turns off. 5. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees counter-clockwise. Parts Required: 1 Rechner Logic Controller: EGI-RLC 1 5 Meter Cable: 0.25SQX4C 1 Sensor: KAS-80-A24-A-K-Y3-NL (for through tank installation) -OR- KAS-80-A14-A-K-Y3-NL (for through site glass)

Wiring Diagrams: Through Tank Oil Water Through Site Glass Oil NOTE: 1/16 air gap between sensor and glass Water

Description: In many industrial applications vibrating rod-type level detectors are used. In some cases these devices cause problems as a result of the mechanical principle the sensor is based on. Vibrating rods, even though they are built tough, are prone to mechanical failure, or can give you false signals due to build up, or creating a cavity in compressible solids. Powder from granular material often works its way into the bearing and creates false level indication. The KAS-80-26-A-200-PTFE-1"-Y5 sensor has no moving parts and no place for material to build-up which eliminates the risk of mechanical failure. The 26 Series sensors are made with food safe PTFE. Versions for areas with a risk of dust and gas explosion are also available with AtEx and IECEx approvals. Function: Remove the old level switch and mount the new Rechner Sensor. Modification to the mounting bracket may or may not be necessary. The sensor is connected to the Rechner Logic Controller with a standard M12 connector cable. The Logic controller needs to be supplied AC power (100-240VAC). The Logic controller provides 24VDC to the sensor and controls the relay output. Once the sensor is mounted and wired the sensor needs to be adjusted. 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the product to be detected. 3. Reset the sensor s sensitivity by turning the potentiometer counter-clockwise 20 full turns, or until the sensor no longer sees the product. 4. Adjust the sensor to the product to be detected by turning the potentiometer clockwise until the sensor sees the product. 5. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees clockwise. Parts Required: 1 Sensor: KAS-80-26-A-200-PTFE-1"-Y5 1 5 Meter Cable: 0.25SQX4C 1 Rechner Logic Controller: EGI-RLC

Wiring Diagrams: or

Description: KAS Series sensors are used as level detectors in the bulk processing industry for many operations. Dry glue pellets, which feed into hot melt glue machines, can be detected in bins, hoppers, and transfer systems. The signal from the sensors can be used to control bin levels, shut off pneumatic conveyors or operate alarm systems Function: The level of bulk pellets in the supply bin of a hot melt glue machine must be kept above a minimum level at all times to prevent the hot melt glue machine running empty. The supply bin of the machine is manually refilled with glue pellets by a worker. For detection of glue pellets, it is recommended that the sensors be immersed in the material. The nonflush mount type of sensor is installed through the wall of the bin to obtain accurate results. One KAS sensor is mounted through the wall of the supply bin at the refill level. The sensor detects a low level of glue pellets in the bin and turns on an alarm or a visual signal. This signal indicates to a worker that it is time to add more glue pellets to the bin. In this application the EGI-RLC power supply is wired as shown. The EGI-RLC acts as the power supply for the sensor as well as a signal conditioner to turn the sensor signal into a SPDT relay output. This simplifies installation and allows for a wider variety or signal devices to be used. Parts Required: 1 Rechner Logic Controller: EGI-RLC 1 Sensor: KAS-80-A24-A-K-Y3-NL (M30 diameter) -OR- KAS-80-35-A-M32-Y3-NL (M32 diameter) 1 5 Meter Cable: 0.25SQX4C

Wiring: AC power is wired to terminals 10, and 12. The sensor is wired to terminals 4, 5, and 6. The low level signal is wired to terminals 1 and 2. Adjust the sensor to detect the pellets in the tank: 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the bulk material. 3. Find the switching point of the bulk material by turning the potentiometer clockwise until the sensor detects the product. 4. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees clockwise.