Evaluation of Sorbents at Elevated Temperatures for Downhole Application

Similar documents
Shortcut Model for Predicting Refrigeration Cycle Performance

A Novel Freeze Drying Process by Using Self-Heat Recuperation Technology

Identification of the Most Effective Heat Exchanger for Waste Heat Recovery

Modelling of divided wall column

A New Graphical Approach for Heat Exchanger Network Retrofit Considering Capital and Utility Costs

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Compression of Fins pipe and simple Heat pipe Using CFD

Limiting Distances for Flame Merging of Multiple n-heptane and Di-tert-Butyl Peroxide Pool Fires

Effect of the Outlet Air Reuse on Thermal Efficiency of a Pilot Plant Spray Dryer with Rotary Atomizer

Minimising Energy Use in Milk Powder Production using Process Integration Techniques

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Recent Advances in Energy, Environment and Economic Development

4. Deflection Tools and Technique

Modelling of End-use Electricity Consumption and Saving Potential in Household Sector in Northern Thailand

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Desiccant Cooling with Solar Energy

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Performance Analysis of a Solid Desiccant Air Dehumidifier

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Effect of Vacuum Cooling Operation Parameters on Cooling Time and Weight Loss of Chinese Cabbage

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Economic Analysis Based on Energy and Water Consumptions between Air-Cooling and Water-Cooling

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Thermodynamics II Chapter 5 Refrigeration

Passive cooling of telecommunication outdoor cabinets for mobile base station

Fundamental Principles of Air Conditioners for Information Technology

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Mud-Motor Characterization

Experimental study of the influence of geometrical parameters on the cavitation of a small centrifugal pump

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Adsorption refrigeration system using waste heat

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Experimental and Numerical Study on a Dryexpansion Shell-and-Tube Evaporator Used in Wastewater Source Heat Pump (WWSHP)

Cassava Chip Drying by Using a Small-Scale Hot-Air Microwave Oven

Impact of TXV and Compressor in the Stability of a High-End Computer Refrigeration System

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Fan Selection. and Energy Savings

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

HIGH QUALITY VAPOR PHASE REFLOW SOLDERING. SMTA Arizona-Sonora December 4th 2012

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

Chapter 11 REFRIGERATION CYCLES

VORTEX TUBE REFRIGERATION SYSTEM BASED ON COMPRESSED AIR

CHEMICAL ENGINEERING TRANSACTIONS

REVENT Vacuum cooling

Requirements for Repair of a Miniature Liquid Helium-3 Refrigerator

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Development of Rotating Tray Dryer and Study of the Hot Air Flow Pattern with Computational Fluid Dynamics

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

RIGID DC LIQUID CHILLER

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

How Wicks and Orientation

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Liquid Ring Vacuum Pumps, Compressors and Systems

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

ANALYSIS OF DESICCANT COOLING SYSTEM

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

INFLUENCE OF DIFFERENT TEMPERING PERIOD AND VACUUM CONDITIONS ON THE RICE GRAIN BREAKAGE IN A THIN LAYER DRYER

ENSC 388. Assignment #6

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

CHAPTER 1 INTRODUCTION

Chapter 11 REFRIGERATION CYCLES

Transcription:

A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 29, 2012 Guest Editors: Petar Sabev Varbanov, Hon Loong Lam, Jiří Jaromír Klemeš Copyright 2012, AIDIC Servizi S.r.l., ISBN 978-88-95608-20-4; ISSN 1974-9791 The Italian Association of Chemical Engineering Online at: www.aidic.it/cet DOI: 10.3303/CET1229258 Evaluation of Sorbents at Elevated Temperatures for Downhole Application Erik Pennewitz* a, Thomas Kruspe b, Sebastian Jung b, Meinhard Schilling a a Technische Universität Braunschweig, Hans-Sommer-Straße 66, 38106 Braunschweig, Germany b Baker Hughes, Baker-Hughes-Straße 1, 29221 Celle, Germany e.pennewitz@tu-bs.de The drilling of geothermal wellbores provides a basis for an efficient exploitation of geothermal energy. It is usually more demanding than conventional high-temperature applications for the oil and gas industry. The temperatures are generally higher, and all components of the downhole system will be exposed to temperatures between 200 C and 250 C and to harsh environmental conditions like strong vibrations, shocks, and high pressures. The high wellbore temperatures may prevent the utilization of electronic components and can negatively influence accuracy and precision of sensors. Due to the drilling depth of deep geothermal wellbores a failure of a downhole system seriously impacts the cost and economical efficiency of the geothermal project. Therefore, reliable technical solutions are paramount for the success of geothermal projects. To date, there is no existing commercial technology capable of providing instrumentation that meets the requirements for the operation of downhole instrumentation in deep and hot geothermal wellbores. One solution under investigation is to use an active cooling system to cool existing sensors and electronics. Techniques that lower the temperature inside the cooling systems below the downhole temperature are considered as active cooling methods, in contrast to passive heat dissipation. Active cooling systems based on phase change from solid to liquid as well as from liquid to gas provide a good compromise between cooling power, temperature drop, and operation time. While phase change from solid to liquid was used in the past, it provides significantly lower enthalpy compared to a phase change from liquid to gas. Therefore, the liquid-to-gas concept is appealing. Unfortunately, the large gas volume is not easy to manage downhole. The sorption of gas in a desiccant is one potential solution and will be further investigated in this paper. Important for the considered cooling system are selection of an optimal phase change material and the design and application of a suitable sorption process. We designed two special experimental setups to investigate the sorption process, and to characterize the sorption rate and capacity of different desiccants at elevated temperatures and pressures. We show results of a characterization of two potential desiccants for downhole application. 1. Cooling Technologies Several concepts for actively cooling downhole electronics were investigated in the past (Bennett 1986; Flores, 1996), always in combination with thermal insulation. Thermal insulation is critical because it minimizes the amount of cooling energy, phase change material, and desiccant. Thermoelectric cooling may be used for hot-spot cooling of certain electronic components or sensors, but this technique adds heat to the thermally insulated electronics. Furthermore, thermoelectric cooling is dependent on an external energy supply. This external energy is commonly provided by a turbine Please cite this article as: Pennewitz E., Kruspe T., Jung S. and Schilling M., (2012), Evaluation of sorbents at elevated temperatures for downhole application, Chemical Engineering Transactions, 29, 1543-1548 1543

near the downhole instrumentation and driven by the drilling mud flow. If this external energy supply stops because of a trip out or because the flow of the drilling mud is interrupted due to a technical problem in the pump system, the thermoelectric cooling fails. Furthermore, if the flow of the drilling mud is interrupted, the wellbore is not longer cooled, and most active cooling methods that are based on an external energy supply would also fail. The electronics would have to survive the subsequent raise in temperature because of the heat flow from the wellbore into the downhole instrumentation and the heat dissipation of the electronics. Energy storage, such as batteries, cannot be used because of the high temperatures. In this situation, cooling by a phase change material that can keep the temperature below a certain threshold during the operation time is preferable. Phase change can be from solid to liquid as well as from liquid to gas. In the later case the significant difference in volume between the phases provides additional challenges for the design of such cooling systems. Therefore, solid-to-liquid phase change cooling was applied primarily in the past. Phase change materials (PCMs), in combination with thermal insulation, are in common use in wireline applications (Bennett, 1998). There are two major disadvantages of using phase change from solid to liquid. First, the enthalpy of fusion is lower than the enthalpy of evaporation. Second, after the cooling by a phase change from solid to liquid starts, the process cannot be controlled, whether cooling is still necessary or not. Therefore, to ensure an independent and reliable cooling of the electronics and sensors of the bottomhole assembly, a system based on liquid-to-gas phase change is promising, provided one can find a way to deal with the gas volume. Due to wellbore pressures as high as 2000 bar, a release of the gaseous refrigerant into the environment is not possible. Another possibility would be a compression and reuse of the evaporated refrigerant. Such a cooling system would be complicated and dependant on an external energy supply which is, as mentioned above, not desirable. Therefore, one solution for a reliable and controllable downhole cooling system is the use of a sorption process. In a sorption cooler a refrigerant evaporates, cools the electronic components and sensors, and is then stored in a desiccant. This cooling system would be independent of the external energy supply and the cooling process could be started and stopped to control the temperatures when required. The component for starting and stopping the cooling process could be a pressure or temperature controlled evaporation valve. Every downhole active cooling systems comprises a cooling unit in combination with thermal insulation. An excellent thermal insulation, in combination with an electronics design optimized with regards to power consumption and size, helps to keep the necessary amount of cooling energy low and reduces the amount of phase change material and desiccant to a minimum. Figure 1: Schematic design of a downhole sorption cooler, thermal insulation, required components and electronics. Figure 1 shows a schematic of a liquid-to-gas phase change cooler. The concept could be integrated in a measurement while drilling (MWD) or wireline tool. This concept comprises the following 1544

components: refrigerant tank, where the phase change material is stored, desiccant tank, where the gas is finally stored, control valve, evaporator and thermal insulation. 2. Sorption Cooling One important aspect of a downhole cooler is the performance of the phase change material and the desiccant. For a downhole sorption cooler we have, as mentioned above, special requirements for the desiccant and refrigerant, compared to conventional applications. The desiccant and the refrigerant must be investigated in combination with each other. Some critical specifications for a downhole application of the refrigerant are: - High phase change enthalpy per volume. - The refrigerant should preferably be non-hazardous, and non-toxic. - The vapor pressure of the refrigerant should be in the order of 1 mbar to around 50 bar. Water is a good candidate for a refrigerant because it meets all these requirements. Some critical specifications for a downhole application of the desiccant are: - The volumetric storage capacity of the desiccant with respect to water has to be high. - The speed of sorption for the vaporous water under high temperature must be considered when determining sufficient cooling power. - As with all other components used in the drilling system, the desiccant must possess stability against shock and vibration. - The desiccant has preferably to be to be non-hazardous and non-toxic. - The desiccant should not appreciably increase the price for a downhole tool, as we will require this material in kilograms-per-tool quantities. Previous investigations of the sorption rate and capacity have shown that the presence of air in a desiccant tank can negatively influence the sorption process. The creation and maintenance of a vacuum in a downhole tool during wellbore operations could be relatively challenging. Therefore, it is preferable to use desiccant in a system that is not evacuated. Because of this, we investigated the sorption rate and capacity of different desiccants in combination with water in an evacuated and nonevacuated experimental system. To select an optimal combination of water and desiccant experimental investigations are necessary. Here we show a characterization of two potential desiccants for downhole applications, named desiccant A and desiccant B. An experimental setup to investigate a desiccant and the gaseous refrigerant at temperatures of 250 C and elevated pressures is challenging due to the materials for containing the substances and sealing the containers. We designed two special experimental setups to investigate the sorption process to determine the velocity and capacity of water and different desiccants at higher temperatures and pressures. The two most-promising choices will be explained below. 2.1 First setup: investigation of storage capacity at downhole conditions In a downhole sorption cooler we have one water tank in contact with another tank filled with a desiccant. This is schematically displayed in Figure 1. We used an experimental setup based on this later system. This setup enabled us to characterize the storage capacity of different desiccants at downhole temperatures and different pressures of the vaporous refrigerant. Other components like the evaporator, valve and downhole instrumentation were neglected in these first investigations. Figure 2 displays the weight percent of a test run with water as the refrigerant at a pressure of 9 bar, stored in desiccant A and desiccant B with a temperature of T Desiccant = 230 C. 1545

Figure 2: Comparison of the storage capacity in weight percent of desiccant A and desiccant B at 230 C and with a generated vacuum or air filled in the experimental setup The mean weight percent of stored refrigerant in the two desiccants in a vacuum condition and with an air-filled experimental setup is given in Table 1: Table 1: Comparison of two special desiccants for downhole application Weight percent (Air in exp. setup) Weight percent (vacuum condition) Difference of storage cap. (because of vacuum) Desiccant A 8.39 % 9.56 % 1.17 % Desiccant B 17.15 % 18.93 % 1.78 % We conclude that, at elevated temperatures of 230 C, desiccant B has around two times the storage capacity of desiccant A in combination with water. Furthermore, the creation of a vacuum in a potential downhole phase change cooler is desirable. The air in the desiccant tank might prevent a certain volume of the desiccant from being saturated/reached by the vaporous water. Another possibility might be that without creating a vacuum in the experimental system, air remains in the pores of the desiccant, preventing to be filled by vaporous water. 2.2 Second setup: speed of sorption By using a setup of two tanks in contact as described above it is not possible to monitor the speed of sorption of a desiccant. The loading velocity of a desiccant in a downhole application may be a decisive aspect. If the desiccant is not able to store the vaporous water at a rate which is evaporated to cool the downhole instrumentation, the cooling process will break down. Therefore, we designed a special experimental setup to investigate the sorption process to determine the sorption rate and capacity of different desiccants in combination with water at higher temperatures and pressures. The principal test setup is shown in Figure 3. With this test we were able to investigate the sorption process in real time. 1546

Figure 3: Picture and schematics of the test setup to investigate the sorption velocity and capacity for different material combinations. This setup uses the principle of a beam balance. A tank filled with a desiccant is mounted on one arm of the beam and a refrigerant tank on the other. Both tanks are in contact via a tube and a valve. The beam-balance is supported on a thin metal blade to enable the setup to rotate with extremely low friction. An arm is mounted on the beam balance and transfers the force out of the oven to a scale. At first, a calibration measurement is performed to transform the measured weight at the scale into the amount of adsorbed refrigerant in the desiccant. The setup was designed to control the temperature of both tanks independently. By using an IR-heater temperatures differences of up to 125 C are possible. Results of one example of the test runs of desiccant B are displayed in Figure 4. Figure 4: Weight of stored refrigerant and temperature of desiccant B with vacuum condition in the experimental system. The weight percent stored in desiccant B at vacuum conditions and with air in the experimental system is displayed in Figure 5. Here the exponential time constant is calculated via Eq. 1: 1547

(1) Here X1 and X2 are fit-parameter and tau is the time constant, given as well in Figure 5. Figure 5: Weight percent of stored refrigerant and temperature of desiccant B. Comparison of the sorption speed at vacuum condition and with air in the system At vacuum condition the sorption rate is around four times faster than compared to an air-filled experimental system. 3. Conclusion Active cooling in combination with thermal insulation is a paramount for the exploration and drilling of hot geothermal wellbores and can increase the operational temperature and the reliability of the electronic components of downhole instrumentation. We considered different active cooling methods. One interesting cooling method might be sorption cooling because this method is independent of an external energy supply and can be used at downhole conditions. Water as the refrigerant is a good option. The storage capacity and loading speed of two promising desiccants were investigated and results are shown. We found one desiccant that could be used in a downhole environment at 250 C. The influence of the presence of air in a desiccant tank was investigated. Although the creation of a vacuum within a downhole cooling system is technically challenging, the sorption rate and capacity of a non-evacuated desiccant tank is inferior with respect to desiccant at vacuum conditions. 4. References Bennett G.A., 1986, Active Cooling for Downhole Instrumentation: Design Criteria and Conceptual Design Summary, PhD Thesis, Los Alamos Laboratories, Los Alamos, USA. Bennet G.A., 1998, Thermal Protection Methods for electronics in Hot Wells, In: Kirschmann R., High- Temperature Electronics, 1 st edition, New York, USA, pp. 111-124. Flores A.G., 1996, Active Cooling for Electronics in a Wireline Oil-Exploration Tool, PhD Thesis, Massachusetts Institute of Technology, Cambridge, USA. 1548