DETECTION AREA OA-FLEX AIR T BLUEZONE (1st row) A X B C D 2nd row 3rd row E F G 4th row 5th row 6th row I H J : Emitting spots : Emitting spots (can be eliminated) : Detection Area Emitting area [ feet,inch (m) ] A 6'7" (2.00) 7'7" (2.30) 8'2" (2.50) 9'10" (3.00) B C D E F G H I J 5" (0.13) 6" (0.16) 7" (0.17) 1'3" (0.38) 1'6" (0.46) 1'8" (0.50) 2'4" (0.71) 2'10" (0.86) 3'1" (0.94) 2'9" (0.84) 3'4" (1.01) 3'7" (1.09) 4'5" (1.34) 5'4" (1.62) 5'9" (1.76) 5'9" (1.75) 6'11" (2.11) 7'6" (2.29) 3' (0.92) 3'8" (1.11) 3'11" (1.20) 4'11" (1.49) 5'11" (1.80) 6'5" (1.95) 6'9" (2.06) 8'2" (2.48) 8'10" (2.69) 1'12" 3'8" 4'4" 6'11" 4'9" 7'8" 10'7" Charts show the values in the following area angle adjustment settings ; Depth : 8 Width : 0 8" 9' (0.21) (0.60) (1.13) (1.31) (2.11) (2.75) (1.45) (2.34) (3.23)
DETECTION AREA AIR-SLIDE T/2 BLUEZONE (1st row) A X B C D 2nd row 3rd row E F G 4th row 5th row 6th row I H J : Emitting spots : Emitting spots (can be eliminated) : Detection Area Emitting area [ feet,inch (m) ] A 6'7" (2.00) 7'7" (2.30) 8'2" (2.50) 9'10" (3.00) B C D E F G H I J 5" (0.13) 6" (0.16) 7" (0.17) 1'3" (0.38) 1'6" (0.46) 1'8" (0.50) 2'4" (0.71) 2'10" (0.86) 3'1" (0.94) 2'9" (0.84) 3'4" (1.01) 3'7" (1.09) 4'5" (1.34) 5'4" (1.62) 5'9" (1.76) 5'9" (1.75) 6'11" (2.11) 7'6" (2.29) 3' (0.92) 3'8" (1.11) 3'11" (1.20) 4'11" (1.49) 5'11" (1.80) 6'5" (1.95) 6'9" (2.06) 8'2" (2.48) 8'10" (2.69) 1'12" 3'8" 4'4" 6'11" 4'9" 7'8" 10'7" Charts show the values in the following area angle adjustment settings ; Depth : 8 Width : 0 8" 9' (0.21) (0.60) (1.13) (1.31) (2.11) (2.75) (1.45) (2.34) (3.23)
OUTER DIMENSIONS OA-FLEX AIR T Touchless plate (option) ø83 (ø3 4/16")
OUTER DIMENSIONS AIR-SLIDE T Touchless plate (option) 4 (102) 4 (102)
OUTER DIMENSIONS AIR-SLIDE 2 Touchless plate (option) 4 (102) ø83 (ø3 4/16") 4 (102)
SPECIFICATION OA-FLEX AIR T Operation indicator table Status Set-up Stand-by (Installation mode) Stand-by (Operation mode) Cover color Mounting height Detection area Detection method Area angle adjustment angle adjustment Power supply (*2) Power consumption Operation indicator Test intput Activation output Safety output BLUEZONE (1st row) detection 2nd row detection 3rd row detection 4th-6th row detection detection & 2nd-4th row detection Signal saturation Signal saturation () Sensor failure Operating temperature Operating humidity Noise level Output hold time Response time IP rate Weight Accessories Operation indicator color Yellow Blinking Yellow Green Blue Red Blinking Red Orange Fast Purple Blinking Purple Slow Green Blinking Slow Purple Blinking Fast Green Blinking : Black : 6'7"(2.0m) to 9'10"(3.0m) : See DETECTION AREA : Active infrared reflection(*1) : Depth : -8 to +8 Width : ±7 (2 clicks with 3.5 every click-left/right) : Depth : -14 to +2 Width : ±42 (7 clicks with 6 every click-left/right) : 12 to 24VAC ±10% (50 / 60Hz) 12 to 30VDC ±10% : < 2.5W (< 6VA at AC) : See Operation indicator table : Opto coupler Voltage / 5 to 30VDC Current / 6mA Max. (30VDC) : -31 to 131 F (-35 to +55 C) : < 80% : < 70dBA : Approx. 0.5 sec. : < 0.3 sec. : IP54 : 8.1oz (230g) : 1 Operation manual 2 Mounting screws 1 Mounting template 1 Area adjustment tool 1 Cable 9'10"(3m) (8 0.22mm² AWG24) (*3)
SPECIFICATION AIR-SLIDE T Cover color Mounting height Detection area Detection method Area angle adjustment angle adjustment Power supply (*2) Power consumption Operation indicator Test intput Activation output : Black : 6'7"(2.0m) to 9'10"(3.0m) : See DETECTION AREA : Active infrared reflection(*1) : Depth : -8 to +8 Width : ±7 (2 clicks with 3.5 every click-left/right) : Depth : -14 to +2 Width : ±42 (7 clicks with 6 every click-left/right) : 12 to 24VAC ±10% (50 / 60Hz) 12 to 30VDC ±10% : < 2.5W (< 6VA at AC) : See Operation indicator table : Opto coupler Voltage / 5 to 30VDC Current / 6mA Max. (30VDC) Operation indicator table Status Set-up Stand-by (Installation mode) Stand-by (Operation mode) Safety output BLUEZONE (1st row) detection 2nd row detection 3rd row detection 4th-6th row detection detection & 2nd-4th row detection Signal saturation Signal saturation () NOTE Sensor failure Operating temperature Operating humidity Noise level Output hold time Response time IP rate Weight Accessories :-31 to 131 F (-35 to +55 C) : < 80% : < 70dBA : Approx. 0.5 sec. : < 0.3 sec. : IP54 : 8.1oz (230g) : 1 Operation manual 2 Mounting screws 1 Mounting template 1 Area adjustment tool 1 Cable 9'10"(3m) (8 0.22mm² AWG24) (*3) Operation indicator color Yellow Blinking Yellow Green Blue Red Blinking Red Orange Fast Purple Blinking Purple Slow Green Blinking Slow Purple Blinking Fast Green Blinking The specifications herein are subject to change without prior notice due to improvements. *1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function. *2 : When using this sensor, the sensor has to be connected to a door system which has the SELV circuit. *3 : Overcurrent protection with less than 2A.
SPECIFICATION AIR-SLIDE 2 Cover color Mounting height Detection area Detection method angle adjustment Secondary Activation area angle adjustment Power supply Power consumption Operation indicator Primary, Secondary Activation output : Black : 6'7"(2.0m) to 9'10"(3.0m) : See DETECTION AREA : Active infrared reflection(*1) : Depth : -14 to +2 Width : ±42 ( 7 clicks with 6 every one click-reft/light ) : Depth : -16 to +0 Width : ±7 ( 2 clicks with 3.5 every one click-reft/light ) : 12 to 24V AC ±10% (50/60Hz) 12 to 30V DC ±10% : < 2.0W (< 3VA at AC) : See Operation indicator table Operation indicator table NOTE Status Set-up Stand-by (Installation mode) Stand-by (Operation mode) BLUEZONE (1st row) detection (*2) 2nd row detection 3rd row detection 4th-6th row detection detection (*3) & 2nd-4th row detection Signal saturation(secondary Activation area) Signal saturation () Sensor failure Output hold time : Approx. 0.5 sec. Response time : < 0.3 sec. Operating temperature : -4 to 131 F (-20 to +55 C) Operating humidity : <80% IP rate : IP44 Weight : 8.8oz (250g) Accessories : 1 Operation manual 2 Mounting screws 1 Mounting template 1 Area adjustment tool 1 Power & Primary Activation output cable 8'2" (2.5m) 1 Secondary Activation output cable 8'2" (2.5m) Operation indicator color Yellow Blinking Yellow Green Blue Red Blinking Red Orange Fast Purple Blinking Purple Slow Green Blinking Slow Purple Blinking Fast Green Blinking The specifications herein are subject to change without prior notice due to improvements. *1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function.