DETECTION AREA OA-FLEX AIR T. Active Infrared Sensor FLEX EYE A X B C D E F G. Emitting area

Similar documents
Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h

DESIGN EASY ADJUSTMENT

ARCHITECTURAL DOOR HARDWARE SENSORS CATALOG

Acusensor 3. Instruction Manual

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Plug-in Base, Long Range Sensor E3B2

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

DIGITAL LIGHT CONTROLLER

Process Alarm Module RTA 421

D A R A - 4. Data Aire Relay Auto-Changeover

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Retroreflective sensor with polarization filter

Dissolved Oxygen Analyzers

DTA. Motor thermistor relay. Benefits. Description

Fast Track Troubleshooting

User Manual LIGHTMEN.COM. Apollo A75050

Compressed Air Filtration

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

max C 15 minutes other types on request 3 x 0,25 mm2 or plug M8, other types on request

EC3-X33 Stand-alone Superheat Controller Technical Data

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

DTA04. Motor thermistor relay. Benefits. Description

Danfoss gas detection units

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

Intelligent addressable fire alarm control panel

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Power Supply Display Module PSDM. Installation and Operation Manual

for relative humidity and temperature

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

for relative humidity and temperature

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

PolyGard 2-channel Gas Controller MGC-03

Danfoss gas detection units

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en


Duct Temperature Sensors

ATFLASH. Sensor ATFLASH SENSOR USER GUIDE ATFLASH. Sensor ATFLASH SENSOR USER GUIDE

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

YO3 - YO4 / YL4 - YO5 / YL5

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

VA301C CONTROLLER WITH BACnet OPTION

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

FireNET Plus Wiring Instructions

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

E3M-V. Mark Sensor. Applications

INDICATOR LAMPS & LED REPLACEMENT LAMPS

ELEKTRON ELEKTROLABORATORIJSKE - VISOKOTEMPERATURNE PEĆI. The view from the back of the oven

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

AUDIBLE SIGNALIZATION

Instruction manual for the Infrared Point Type Flame Detector

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

FLEX DC SIDE EMITTING

LF-4000 Series Conventional Fire Alarm Control Unit

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Beck. The differential pressure transmitter for air

HX-80NRAM. High Mount Outdoor Detector

M15051) INSTRUCTION MANUAL

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Passive infrared ceiling sensor

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

CCS-100. Installation Manual

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

QPM21 Series Duct CO 2 and Air Quality Sensors

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

For more information, please visit 3-form.com or call

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Analog Transmitter AT1000 AT1

Installation/Owner s Manual Models 1504 / 1506

Fan speed controller Type Saginomiya XGE

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Oxygen (O2) Single-Point Gas Detection System

Series Internal Detector

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Technical data lumina MS4

Life insurance for your electronics

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Transcription:

DETECTION AREA OA-FLEX AIR T BLUEZONE (1st row) A X B C D 2nd row 3rd row E F G 4th row 5th row 6th row I H J : Emitting spots : Emitting spots (can be eliminated) : Detection Area Emitting area [ feet,inch (m) ] A 6'7" (2.00) 7'7" (2.30) 8'2" (2.50) 9'10" (3.00) B C D E F G H I J 5" (0.13) 6" (0.16) 7" (0.17) 1'3" (0.38) 1'6" (0.46) 1'8" (0.50) 2'4" (0.71) 2'10" (0.86) 3'1" (0.94) 2'9" (0.84) 3'4" (1.01) 3'7" (1.09) 4'5" (1.34) 5'4" (1.62) 5'9" (1.76) 5'9" (1.75) 6'11" (2.11) 7'6" (2.29) 3' (0.92) 3'8" (1.11) 3'11" (1.20) 4'11" (1.49) 5'11" (1.80) 6'5" (1.95) 6'9" (2.06) 8'2" (2.48) 8'10" (2.69) 1'12" 3'8" 4'4" 6'11" 4'9" 7'8" 10'7" Charts show the values in the following area angle adjustment settings ; Depth : 8 Width : 0 8" 9' (0.21) (0.60) (1.13) (1.31) (2.11) (2.75) (1.45) (2.34) (3.23)

DETECTION AREA AIR-SLIDE T/2 BLUEZONE (1st row) A X B C D 2nd row 3rd row E F G 4th row 5th row 6th row I H J : Emitting spots : Emitting spots (can be eliminated) : Detection Area Emitting area [ feet,inch (m) ] A 6'7" (2.00) 7'7" (2.30) 8'2" (2.50) 9'10" (3.00) B C D E F G H I J 5" (0.13) 6" (0.16) 7" (0.17) 1'3" (0.38) 1'6" (0.46) 1'8" (0.50) 2'4" (0.71) 2'10" (0.86) 3'1" (0.94) 2'9" (0.84) 3'4" (1.01) 3'7" (1.09) 4'5" (1.34) 5'4" (1.62) 5'9" (1.76) 5'9" (1.75) 6'11" (2.11) 7'6" (2.29) 3' (0.92) 3'8" (1.11) 3'11" (1.20) 4'11" (1.49) 5'11" (1.80) 6'5" (1.95) 6'9" (2.06) 8'2" (2.48) 8'10" (2.69) 1'12" 3'8" 4'4" 6'11" 4'9" 7'8" 10'7" Charts show the values in the following area angle adjustment settings ; Depth : 8 Width : 0 8" 9' (0.21) (0.60) (1.13) (1.31) (2.11) (2.75) (1.45) (2.34) (3.23)

OUTER DIMENSIONS OA-FLEX AIR T Touchless plate (option) ø83 (ø3 4/16")

OUTER DIMENSIONS AIR-SLIDE T Touchless plate (option) 4 (102) 4 (102)

OUTER DIMENSIONS AIR-SLIDE 2 Touchless plate (option) 4 (102) ø83 (ø3 4/16") 4 (102)

SPECIFICATION OA-FLEX AIR T Operation indicator table Status Set-up Stand-by (Installation mode) Stand-by (Operation mode) Cover color Mounting height Detection area Detection method Area angle adjustment angle adjustment Power supply (*2) Power consumption Operation indicator Test intput Activation output Safety output BLUEZONE (1st row) detection 2nd row detection 3rd row detection 4th-6th row detection detection & 2nd-4th row detection Signal saturation Signal saturation () Sensor failure Operating temperature Operating humidity Noise level Output hold time Response time IP rate Weight Accessories Operation indicator color Yellow Blinking Yellow Green Blue Red Blinking Red Orange Fast Purple Blinking Purple Slow Green Blinking Slow Purple Blinking Fast Green Blinking : Black : 6'7"(2.0m) to 9'10"(3.0m) : See DETECTION AREA : Active infrared reflection(*1) : Depth : -8 to +8 Width : ±7 (2 clicks with 3.5 every click-left/right) : Depth : -14 to +2 Width : ±42 (7 clicks with 6 every click-left/right) : 12 to 24VAC ±10% (50 / 60Hz) 12 to 30VDC ±10% : < 2.5W (< 6VA at AC) : See Operation indicator table : Opto coupler Voltage / 5 to 30VDC Current / 6mA Max. (30VDC) : -31 to 131 F (-35 to +55 C) : < 80% : < 70dBA : Approx. 0.5 sec. : < 0.3 sec. : IP54 : 8.1oz (230g) : 1 Operation manual 2 Mounting screws 1 Mounting template 1 Area adjustment tool 1 Cable 9'10"(3m) (8 0.22mm² AWG24) (*3)

SPECIFICATION AIR-SLIDE T Cover color Mounting height Detection area Detection method Area angle adjustment angle adjustment Power supply (*2) Power consumption Operation indicator Test intput Activation output : Black : 6'7"(2.0m) to 9'10"(3.0m) : See DETECTION AREA : Active infrared reflection(*1) : Depth : -8 to +8 Width : ±7 (2 clicks with 3.5 every click-left/right) : Depth : -14 to +2 Width : ±42 (7 clicks with 6 every click-left/right) : 12 to 24VAC ±10% (50 / 60Hz) 12 to 30VDC ±10% : < 2.5W (< 6VA at AC) : See Operation indicator table : Opto coupler Voltage / 5 to 30VDC Current / 6mA Max. (30VDC) Operation indicator table Status Set-up Stand-by (Installation mode) Stand-by (Operation mode) Safety output BLUEZONE (1st row) detection 2nd row detection 3rd row detection 4th-6th row detection detection & 2nd-4th row detection Signal saturation Signal saturation () NOTE Sensor failure Operating temperature Operating humidity Noise level Output hold time Response time IP rate Weight Accessories :-31 to 131 F (-35 to +55 C) : < 80% : < 70dBA : Approx. 0.5 sec. : < 0.3 sec. : IP54 : 8.1oz (230g) : 1 Operation manual 2 Mounting screws 1 Mounting template 1 Area adjustment tool 1 Cable 9'10"(3m) (8 0.22mm² AWG24) (*3) Operation indicator color Yellow Blinking Yellow Green Blue Red Blinking Red Orange Fast Purple Blinking Purple Slow Green Blinking Slow Purple Blinking Fast Green Blinking The specifications herein are subject to change without prior notice due to improvements. *1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function. *2 : When using this sensor, the sensor has to be connected to a door system which has the SELV circuit. *3 : Overcurrent protection with less than 2A.

SPECIFICATION AIR-SLIDE 2 Cover color Mounting height Detection area Detection method angle adjustment Secondary Activation area angle adjustment Power supply Power consumption Operation indicator Primary, Secondary Activation output : Black : 6'7"(2.0m) to 9'10"(3.0m) : See DETECTION AREA : Active infrared reflection(*1) : Depth : -14 to +2 Width : ±42 ( 7 clicks with 6 every one click-reft/light ) : Depth : -16 to +0 Width : ±7 ( 2 clicks with 3.5 every one click-reft/light ) : 12 to 24V AC ±10% (50/60Hz) 12 to 30V DC ±10% : < 2.0W (< 3VA at AC) : See Operation indicator table Operation indicator table NOTE Status Set-up Stand-by (Installation mode) Stand-by (Operation mode) BLUEZONE (1st row) detection (*2) 2nd row detection 3rd row detection 4th-6th row detection detection (*3) & 2nd-4th row detection Signal saturation(secondary Activation area) Signal saturation () Sensor failure Output hold time : Approx. 0.5 sec. Response time : < 0.3 sec. Operating temperature : -4 to 131 F (-20 to +55 C) Operating humidity : <80% IP rate : IP44 Weight : 8.8oz (250g) Accessories : 1 Operation manual 2 Mounting screws 1 Mounting template 1 Area adjustment tool 1 Power & Primary Activation output cable 8'2" (2.5m) 1 Secondary Activation output cable 8'2" (2.5m) Operation indicator color Yellow Blinking Yellow Green Blue Red Blinking Red Orange Fast Purple Blinking Purple Slow Green Blinking Slow Purple Blinking Fast Green Blinking The specifications herein are subject to change without prior notice due to improvements. *1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function.