AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

Similar documents
Thermal Comfort with Convective and Radiant Cooling Systems

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams

American Society of Heating, Refrigerating and Air-Conditioning Engineers

To describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Passivhaus school kitchens

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

THE EFFECT OF HEAT LOAD ARRANGEMENT ON THE PERFORMANCE OF RADIANT PANELS

Human response to thermal environment in rooms with chilled beams

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

The impact of thermal loads on indoor air flow

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Don t Turn Active Beams Into Expensive Diffusers

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

for commercial kitchen ventilation

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Comparison of radiant and convective cooling of office room: effect of workstation layout

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

NORDcanopy Kitchen ventilation

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

KVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology

Simulation of Full-scale Smoke Control in Atrium

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

EFFECTS OF COMBINING SMART SHADING AND VENTILATION ON THERMAL COMFORT

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

An experimental study of the impact of tunnel suppression on tunnel ventilation

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Heyam Daod. Keywords Fine-grained soils, liquid limit, microwave drying, moisture content

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Heat Transfer in Evacuated Tubular Solar Collectors

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

New Convection Correlations for Cooled Ceiling Panels in Room with Mixed and Stratified Airflow

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Performance of an Improved Household Refrigerator/Freezer

THE EFFECT OF HIGH TEMPERATURE AIR DRYING ON EVAPORATION, RUNNABILITY AND COATED PAPER PROPERTIES. Pertti Heikkilä and Pasi Rajala

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

THE AMOUNT OF ACCUMULATED DUST IN DUCTS OF NEW HVAC INSTALLATIONS

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

Design and Experimental Studies on Modified Solar Dryer

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

Purdue e-pubs. Purdue University

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Displacement Ventilation

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

Cork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

MARIYA INTERNATIONAL SCHOOL AL-JUBAIL L-8 PHYSICS WORKSHEET(Heat & energy )

Mango Sheet Drying by the Solar Dryer Combine with Electric Coil

series900 the Essence

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

Performance Evaluation of Hybrid Solar Water Heating System Using Wire Screen Packed Solar Air Heater

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Residential ventilation concepts based on the idea of displacement airflow distribution

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

GUIDANCE AND TOOLS FOR CHILLED CEILINGS COMBINED WITH A WET COOLING TOWER

Experimental Research on Monomial Cooling Measure of Greenhouse in Summer

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

American International Journal of Research in Science, Technology, Engineering & Mathematics

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Key Words: Microalgae; Solar Dryer; Exergy Analysis; Energy Analysis;

Compression of Fins pipe and simple Heat pipe Using CFD

Transcription:

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE R Kosonen 1,*, H Koskela 2 and P Saarinen 2 1 Halton Oy, Haltonintie 1-3, 474 Kausala, Finland 2 Finnish Institute of Occupational Health, Lemminkaisenkatu 14-18 B, 252 Turku, Finland ABSTRACT The main purpose in the design practice of kitchen ventilation has been the calculation of the airflow rate, which is sufficient to extract the convective heat and contaminants. In the most accurate design method, the design of a kitchen ventilation system is based on the air flow rate in the thermal plume. When the convection flow is calculated, the influence of the cooking process is ignored. In this paper, the actual measured plume characteristics of typical kitchen appliances are presented during cooking mode. The conducted measurements show that the generic plume equation gives a suitable platform for practical applications during the cooking mode as well. The critical factors affecting the accuracy are the estimation of the actual convection load and the proper adjustment of the virtual origin. INDEX TERMS Thermal plume, convection flow, kitchen design, displacement ventilation INTRODUCTION Concerns over the indoor environment have increased during recent years as a result of the knowledge about the significance of thermal conditions and air quality on the health, comfort and productivity of workers. In a commercial kitchen, working conditions are especially demanding. There are four main factors affecting thermal comfort, these being: air temperature, thermal radiation, air velocity and air humidity. At the same time, high emission rates of contaminants are released from the cooking process. Ventilation plays an important role in providing comfortable and productive working conditions and in securing the contaminant removal. The published studies demonstrate quite clearly the health risk of cooking. Thiebaud (1995) indicates that the fumes generated by frying pork and beef are mutagenic. Hence, the chefs are exposed to relatively high levels of airborne mutagens and carcinogens. Vainiotalo (1993) carried out measurements at eight workplaces. His survey confirmed that cooking fumes contain hazardous components. It also indicated that kitchen workers may be exposed to relatively high concentration of airborne impurities. Based on the sensible heat load, the requested airflow rate is possible to calculate. As for the heat load method, consideration is made for the convective heat output of the cooking appliance, the area of exposure and the distance of the extract. The main idea is to adjust the required airflow rate based on the convection heat gain or to be more specific, based on the thermal plume of a kitchen appliance. The most well-known code which utilizes this approach is German VDI (VDI 1999). In this paper, the actual plumes of typical kitchen appliances are presented according to the measurements at the laboratory of Finnish Institute of Occupation Health. Based on the conducted measurements, the effect of cooking on the air flow rate is analyzed. RESEARCH METHODS The main idea of the measurements was to analyse the convection flows of the actual kitchen appliances during the cooking mode. The measurements were carried out in a test room, built inside a laboratory facility. Construction consists of a steel frame, with floor dimensions of 1 m x 4 m and a height of 6 m. The room space is thermally insulated with 5 mm thick polystyrene elements from the surroundings. The supply air flow rate is released using displacement ventilation principle from the floor level through six multi-nozzle ductworks which guarantees undisturbed convection flow of a kitchen appliance. The total supply air flow rate of 6 l/s was adjusted to cover * Corresponding author email: risto.kosonen@halton.com 2624

the induced air flow rate of convection flow 3 meters above the heated surface. The return air grille was installed at the height of 6 m. The supply air temperature was about 2 o C. Convection plumes from an electric range, a chrome range, a gas range, an induction range, a fryer and an induction griddle were studied during the cooking mode. The description of the studied appliances is presented in Table 1. The cooking mode of ranges was arranged by boiling water in two 1 l kettles, Fig 1. In the case of the induction griddle, cooking is exucuded by frying boneless chicken breast, Fig 2. In the fryer, the oil temperature is maintained at 18 o C. Equipment Iron Range 5x8x95 (H) Gas Range 4x65x46 (H) Chrome Range 5x8x95 (H) Induction Range 38x7x14 5 (H) Fryer 36x435x26 (H) Induction Griddle 52x44x17 5 (H) Total Power (W) Table 1. Description of the kitchen appliances. Boiling Power (W) Convective Power (W) Radiation/Rest (W) Surface temperature ( o C) 544 357 (65.6 %) 1142 (21. %) 728 (13.4 %) ~35 4625 227 (49.1 %) 1885 (4.8 %) 47 (1 %) - 6277 3974 (63.3 %) 1372 (21.9 %) 931 (14.8 %) ~4-5 369 (8 % of max. power) 29 (78.6 %) 22 (6. %) 57 (15.4 %) ~ 4-7 53-23 (43.4 %) 3 (56.6 %) 18 (oil) 872-18 (2.6 %) 692 (79.4 %) 21 During the tests, the actual power of the electric appliances was measured with clip-on-ammeter. The power of the gas range was determined from the measured gas consumption. The convection heat power was computed from the measured temperatures and velocities. Based on the amount of vaporized water, the boiling power was also computed. From the balance, the remaining heat power is attributed to be radiation. Figure 1. The cooking arrangement of the ranges. 2625

Figure 2. The cooking arrangement of the induction griddle. The plume measurements were carried out with probes that were attached to a computer-controlled traversing system moving them from point to point and scanning the determined four measurement planes at the heights of.8 m, 1.2 m, 1.6 m and 2. m above the appliances. The basic measurement grid of 1.1 m x 1.1 m consists altogether 121 measurement points ( m interval) in each plane. Air velocity was measured with Kaijo Denki WA- 39 ultrasonic probes, which have an accuracy of.2 m/s. In the case of the induction griddle, the velocity was measured with omnidirectional TSI 162 hot bulb sensors and a turbulence correction was applied to the velocity results. The air temperatures were measured with Fenwale thermistors having an accuracy of K RESULTS Measured convection flows were compared with generic plume equation (VDI 1999), Eqs. 1 and 2. In VDI, the virtual origin is set to be at 1.7 D h below the surface of the appliance. In addition, the effect of the product specific virtual origin was studied. The empirical coefficient of each appliance was adjusted to get reasonable correlation with the measurements. q 3 1/ 3 ( z + a D ) 5 / Φ = (1) v, p 5 h conv where q v,p is the airflow in convective plume, [m 3 /s] z is the height above the cooking surface, [m] D h is the hydraulic diameter of the appliance, [m] Φ conv is the cooking appliance convective heat output, [W] a is the product specific factor of the virtual origin L W D h = 2 (2) L + W L,W are the length and width of the cooking surface, [m] The measured and estimated air flow rate of low capacity appliances are presented in Fig. 3. The results of more energy intensive ranges, in turn, are presented in Fig. 4. The relative difference between and numerical is more significant with low heat gains. With high gains, the air flow rates of these two methods are quite similar. With the adjusted virtual origin, it is possible to reach a reasonable accuracy for practical applications. This means that the effect of the released vapour from the boiling and cooking processes does not have significant effect on the convection flow. For the high heat gain appliances, the coefficient of the virtual origin is 1.2 1.5. For the low heat gain appliance, values of 2.- 2.5 gives reasonable correlation with the measurements. 2626

8 6 4 2.8.6.4.2 Air Flow Rate of Fryer 2.5 x Dhydr 5 Air Flow Rate of Induction Griddle.5 2.x Dhydr Air Flow Rate of Induction Range 8 6 4 2.8.6.4.2 2.x Dhydr Figure 3. Measured and calculated air flow rates of the low heat gain appliances. 2627

Air Flow Rate of Iron Range.35.3 5 5.5 Measured numerical 1.2x Dhydr Air Flow Rate of Gas Range.35.3 5 5.5 1.2x Dhydr.4.35.3 5 5.5 Air Flow Rate of Chrome Range 1.5x Dhydr Figure 4. Measured and calculated air flow rates of the high heat gain appliances. DISCUSSION The conducted measurement show that the power of distance in the generic plume equation can not exactly describe the induced air flow rate with high heat gains. However, it gives a reasonable accuracy for practical applications when the convection load is known and the location of the virtual origin is adjusted. Based on in tandem study of idle mode conditions (Kosonen et al. 25), it can be stated that the same location of virtual origin can be used during idle and cooking modes. In comparison with the idle mode conditions, the ratio 2628

of the convection is not larger in the idle mode. This observation means that if there is no special control features applied in the kitchen appliance, then the idle mode determinates the requested air flow rate. Typically, the mass flow of water during boiling was only about 1-1.5 g/s. Thus, the released vapour flow is small compared with the induced air flow rate and therefore does not have a significant effect on the convection flow. Thus, the actual convection load and the product specific virtual origin can describe nicely the plume during the cooking process. When boiling water in two kettles, there are two peaks of velocity close to the appliances. These two separate plumes merge at a certain distance, after which the gives a good correlation with the measurements. CONCLUSION The generic plume equation gives reasonable accuracy in the cooking mode, when an appliance-specific, optimized coefficient of the virtual origin is applied. The vapour released from the process does not have a significant influence on the convection flow. The critical factors for accuracy of the equation are the correct estimation of the actual convection load and the optimal selection of the appliance-specific virtual origin. ACKNOWLEDGEMENTS The study is supported by Technology Agency of Finland (TEKES). The authors wish to thank Mr. Pasi Karhunen from Metos Oy for technical advices and loans of the kitchen appliances that made these tests possible. REFERENCES Kosonen R., Koskela H. and Saarinen P. 25. An experimental study of thermal plumes of kitchen appliances, Proceedings of the 1 th International Conference on Indoor Air Quality and Climate Indoor Air 25, Beijing China. Thiebaud HP., Knize MG., Kuzmicky PA., Hsieh DP. and Felton JS (1995). Airborne mutagens produced by frying beef, pork and a soy-based food, Food and Chemical Toxicology, Volume 33, Issue 1, 1995, Pages 821-828 Vainiotalo S. and Matveinen K. (1993), Cooking fumes as a hygienic problem in the food and catering industries, American Industrial Hygiene Association Journal, Volume 54, Issue 7, 1993, Pages 376-382 Verein Deutcher Ingenieure VDI (1999) Standard 252: Ventilation Equipment for Kitchens. 2629