Multitube- Heatexchanger 0,5-8,0M² INSTALLATION AND OPERATION SPECIFICATION

Similar documents
Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Laser welded Plate Heat Exchangers Type XPS

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

HUSKY SANITARY SERIES

AIR SPRAY GUN and AIRBRUSH

P/N: AODD-0613-B. Sanitary Air Operated Diaphragm Pumps

Instruction Manual, Rotary Spray Heads

Meets the Highest Standards in Sanitary Cleaning

requirements can be equipped with an additional product temperature control probe, and with a printer.

Sanitary Drum Transfer Pumps

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

The theory behind heat transfer

Dome Fiber Optic Closure SC-221

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

Cheese kettles SKH Let's add value to milk. Basic/Basic+ Advanced/Advanced+ Professional Premium

MIX Type Blenders. I Application. I Principle of operation

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

WFIS. Water For Injection Stills

Industrial and collective. With coil exchanger. Technical data. Initial heat-up. surface area. Exchanger. Exchanger capacity.

TECHNICAL DATA SHEET. InJet 388 CRD. STENCIL cleaning PUMPRINT cleaning CHAMBER.

TECHNICAL INFORMATION L / A 1

No. 1 in Europe New on offer air curtain GUARD

TECHNICAL DATA SHEET NEW UPGRADED. InJet 888 CRD. FILTERS OF REFLOW OVENS, SOLDERING FRAMES cleaning PCBs cleaning CHAMBER.

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

InJet 388 CRD - 2PR TECHNICAL DATA SHEET. MISPRINT PCBs cleaning STENCIL cleaning PUMPRINT cleaning PCBs cleaning.

TECHNICAL DATA SHEET. InJet 388 CRD. STENCIL cleaning PUMPRINT cleaning CHAMBER.

Recirculating Coolers

Specially Designed Waste Water & Sewage Pumps

PolyRex polymer make-up unit, vacuum conveyor support Technical specification

TOX -Spray System SP. Data sheet /

OPERATION & MAINTENANACE MANUAL

Tetra Pak Indirect UHT unit PFF with tubular heat exchanger Efficient UHT unit for flexible production of ambient or hot-filled prepared food products

INDIRECT WATER HEATERS

ROTARY SPRAY HEADS CATALOGUE

Hand Held Welding Guns

MINI COMBI OVENS REPLACEMENT PARTS LIST

A world of heat exchangers Optimized heat transfer solutions for every application

System Components. Vacuum stations, Central filter systems, Vacuum receivers & Piping systems

SaniForce. A Complete Sanitary Pump Line. unleash the

Explosion-proof Immersion Heater Type D-8660

COTES ALL-ROUND THE C65 RANGE

SaniForce. A Complete Sanitary Pump Line. unleash the

Heat Recovery from Hot Waste Air with the Fernett Waste Air Heat Exchanger Type MONSUN

Tetra Pak Continuous Freezer S A2 Self-contained conntinuous freezers with built in refrigeration unit

SIGMAWIG ALL WELDED PLATE HEAT EXCHANGERS

These pumps offer unique capabilities which are either not available or costly to acquire with other pumps.

TMCI Padovan Evaporators

AQUASNAP JUNIOR 30RHV

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

VS LD series vertical steam sterilizers

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

Pre-Installation guide PRO. For TopBrewer Pro Version:

OXeN. Ductless ventilation with heat recovery.

Solar Thermal Energy

AUTOMATIC VACUUM MACHINES AND PACKAGING LINES

1,500 2,500 4,500 9,000 14,000 20,000 30,000 50,000 1,000 1,000 2,000 3,000 4,000 8,000 12,000 18,000 N/A PF2500 (NO UVC)

VEGA SERIES ROTARY WASHING MACHINES

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

No. 1 in Europe New on offer air curtain GUARD

Filtering Ideas, Making Innovations

Brazed Plate Heat Exchangers TTP s Series

"ER" Series Electric Humidifier

Vacuum cleaners Multi 20

Gas cooler series RC 1.1

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation

PCH/new Series. High performance, total flexibility

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Thermodynamics: Homework A Set 7 Jennifer West (2004)

GAS ABSORPTION HEAT PUMP

Thermoelectric Bath. Series HEB

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

EDS - EDC. Vacuum Insulating Oil Treatment Plants

Heat exchanger plates

Gasketed and brazed plate heat exchangers

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

Instruction manual ISO-MIX Skid Mounted Pump Unit

SHELL AND TUBE HEAT EXCHANGER (STHE) - part b

Wash Baskets & Machine Accessories. For use in Miele Large Chamber Washers Models PG 8527 & PG 8528

PHARMACEUTICAL INDUSTRY CLEANING SYSTEMS

CHILLED BEAM CASSETTE IQ STAR LYRA

B2009 compact. Dal 1901 COD

Air Shower TECHNICAL DATA

Some Heat Transfer Problems. A hydrocarbon oil (mean heat capacity = 0.50 BTU/(lb m

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE

Thermoelectric Bath. Series HEB

Liquid Drainers LIQUID DRAINERS

SaniForce. unleash the. A Complete Sanitary Pump Line. Indianapolis Chicago San Juan

MIXING AND OTHER PROCESSING EQUIPMENT FROM THE HEART OF EUROPE

ZOLLER. power shrink. The Modular Shrink Unit for your Production

X1 series Submersible Drainage Pump

MANUFACTURER OF HEATING ELEMENTS

Instruction Manual. Pharma-X ESE02197-EN Original manual

DELIVERY PROGRAMME KITCHEN BOWLS (sinks) & BATHROOM BOWLS (basins)

STEAM STERILIZER SERIE S1000 (RBE)

Industrial vacuum cleaners ATTIX 30

GALATEA DOMUS. Dal 1901 COD

STATIC MIXERS STATIC MIXING HEAT EXCHANGERS EJECTORS IN-LINE HEATER IN-TANK HEATER JET MIXING EDUCTOR DESUPERHEATER

Industrial vacuum cleaners AERO 26. Compact wet&dry vacuum cleaner with filter cleaning and ergonomic design

Transcription:

Multitube- Heatexchanger 0,5-8,0M² INSTALLATION AND OPERATION SPECIFICATION 19-09-2014

Installation Installation & Safety parameters Before installing the Heat-exchanger, follow these requirement: 1. Make sure that all connections (Product, water, cooling media, stream and condensate) is made so that it is not possible to overhear/cool the heat-exchanger. 2. Make sure that the heat-exchanger is installed technical correct. (Welds, constructions, pipe holders, seal, etc.) 3. It is the user s responsibility that the installation are made correct in reference to safety. Valves and other security installations, check your local authority. 4. If the Heat-exchanger is supplied with steam, then your make sure that the condensate is taken out of the lowest point of the installation. 5. Make sure that Warning signs is placed on the Heat-exchanger. Heat-exchanger incl. pipes have to be installed without danger to the operators. 6. Never run the Heat-exchanger above the following limits. The Heat-exchanger is connected (See drawing at page 5). The Heat exchanger should be installed horizontal or vertically. Operation: The Heat-exchanger is normally used in connection to process systems. The application is cooling or heating of products ore water, above standings limits.

Technical specification Type: W-0,5-51-51 to W-08-150-51 Application: In connection for cooling and heating water and other products. Design for 40 bar: Sanitary design outside Ø129x2,0 or Ø209x3,0 pipes, made of stainless steel aisi 316L. Inside Ø12x1,0mm pipes made of stainless steel aisi 316L. The cooling/heating flow is outside of the Ø12x1,0mm pipes. Connection: Ø129x2,0 pipes: Ø25 to Ø51 neck up pipe with Ø25 to Ø51 clamps for inlet/outlet cooling and heating. Ø51 to Ø129 clamps for inlet/outlet of the product. Ø209x3,0 pipes: Ø25 to Ø51 neck up pipe with Ø25 to Ø51 clamps for inlet/outlet cooling and heating. Ø76,1 to Ø154 clamps for inlet/outlet of the product. Design for 60 bar: Sanitary design outside Ø133x4 pipes, made of stainless steel aisi 316L. Inside Ø12x1,0mm pipes made of stainless steel aisi 316L. The cooling/heating flow is outside of the Ø12x1,0mm pipes. Connection: Ø133x4,0 pipes: Ø25 to Ø51 neck up pipe with Ø25 to Ø51 clamps for inlet/outlet cooling and heating. Ø51 to Ø129 clamps for inlet/outlet of the product.

Technical data for 40 bar: Max pressure 4MPa (580 psi) Min pressure 1,5MPa (217 psi) Technical data for 60 bar: Max pressure 6MPa (870 psi) Min pressure 1,5MPa (217 psi) Produced in according to: Directive 97/23/EF - European Approved for fluids gr. 2 "Non dangerous"

Key for ordering General Description Application: In connection with filtration modules or other sanitary applications for cooling/heating of the product. Standard: Sanitary design An external pipe made of stainless steel aisi 316L surrounds internal pipe also made of stainless steel aisi 316L. The cooling/heating medium flow is on the outside of internal pipes. Connection: See above key for ordering, clamps both for inlet and outlet of the cooling/heating medium and for inlet and outlet of the product. Technical Data:

Example: Cooling capacity 2,3 Kw/⁰C with 75m³ product flow, 1 CP viscosity and 3m³/h cooling flow. Max product pressure 4MPa (580 psi) Min medium pressure 1,5MPa (217 psi) Heat transfer area = 2,0m² Liquid volume = Product 6,7L and Medium 7,3L FDA approved materials: 3.1.B certificate, welding certificate and pressure test-sheet.

Dimensions Multitube Heatexchanger 0,5 to 8,0m²

*Dimension after welding ±2,0. Shrinks by welding.

Example 1: Example 2: Key for ordering: W-02-51-51/38 Key for ordering: W-02-101-51

Special Heatexchanger Wila also make Heatexchanger after the customer's request. We also do special exchanger if they are in line with our concept and can be produced in according to the article 3.3 Fluids Gr. 2 Non dangerous.