Proposed Changes to NFPA

Similar documents
Proposed Changes to NFPA

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement 10/20/ :03 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

MEMORANDUM. Technical Committee on Notification Appliances for Fire Alarm and Signaling Systems

NFPA 72 Code Changes vs 2013


First Revision No. 82-NFPA [ Section No ] Submitter Information Verification. Committee Statement. 2 of /21/2013 1:03 PM

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

MNEC NFPA 72 WHITE PAPER

Changes in NFPA

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

Health Care Facility Rehabilitation

Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN

Questions/Comments for Richard Roux from Webinar on 7/11/13

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Florida Building Code 2010

Frequently Asked Questions

26 of 128 9/23/2014 9:25 AM

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Circulation Report for SIG-TMS Comments Document # 72

Second Correlating Revision No. 21-NFPA [ Global Input ]

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

First Revision No. 339-NFPA [ Section No. 2.2 ]

AGENDA NFPA TECHNICAL COMMITTEE ON NOTIFICATION APPLIANCES. Report on Comments Meeting, October 13-14, Richmond Marriott, Richmond, VA

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Changes to NFPA 101A 2013 Edition for Health Care Facilities

2018 NICET Code Transition Changes

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Fire Alarm System Fundamentals

National Fire Protection Association M E M O R A N D U M. Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

ISO INTERNATIONAL STANDARD

INSPECTION AND TESTING FORM

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Report on First Revisions with Statement June 2014 NFPA 101

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

U.S. Codes & Standards for Energy Storage Systems. Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

The 2013 National Fire Alarm and Signaling Code

Early Warning Fire Detection Engineering

A COMPARISON OF FIRE ALARM SYSTEM REQUIREMENTS IN THE US AND UK. James R. Lugar Jr., P.E. Rolf Jensen & Associates, Inc. SFPE 2012 Savannah, GA

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Report on First Revision June 2014 NFPA 5000

MEMORANDUM. Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

MEMORANDUM. NFPA Technical Committee on Fundamentals of Fire Alarm and Signaling Systems (SIG- FUN)

NFPA Updates (c) 2015 SSR, Inc. All rights reserved Florida AHCA Conf

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

Functional Challenges of Integrating Mass Notification and Fire Alarm Systems

MEMORANDUM. Technical Committee on Fundamentals of Fire Alarm and Signaling Systems

Item Review Dates and Times for Future Meetings/Conference Calls

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

Artificial Trees and Fire Performance

FIRE & LIFE SAFTEY STANDARD

Fire Alarm and Life Safety System Inspection Certificate

MEMORANDUM. Technical Committee on Protected Premises Fire Alarm and Signaling Systems

Prefunctional Checklist

Significant Changes to the 2012 IFC Semiconductor Fabrication Facilities. Scott Stookey Senior Technical Staff International Code Council, Austin TX

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Please think twice about printing this matrix. You can it, along with your ballot to or

Full Service Central Station Fire Alarm Listing Evaluation

Unified Fire Authority - Fire Prevention Bureau

Second Revision No. 102-NFPA [ Global Comment ] Submitter Information Verification. Committee Statement

NFPA Changes

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

The following information shall become and form part of the contract documents.

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

2019 COURSE CATALOG (rev )

EC 5.10 FIRE PREVENTION MANAGEMENT

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

Transcription:

2017 NFPA Conference & Expo Proposed Changes to NFPA 72-2019 Presented by: Daniel O Connor (SIG-IDS), Jensen Hughes Robert Schifiliti (SIG-NAS), R.P. Schifiliti Associates William Koffel (SIG-ECS), Koffel Associates, Inc. Richard Heffernan (SIG-TMS), SDi Merton Bunker (SIG-AAC), EYP Architecture & Engineering 1

2017 NFPA Conference & Expo CEUs: To receive CEUs for this session, scan your badge at the back of the room before leaving Evaluation: Complete a session evaluation on the mobile app. (Search app store for NFPA 2017 C&E. ) Handouts: Handouts will be available via the mobile app and at nfpa.org/conference Recordings: Audio recordings of all sessions will be available free of charge via NFPA Xchange. 2

What Does the Future Hold?? 3

Decoding the Terminology FR = First Revision CN = Committee Note FDM = First Draft Meeting SDM = Second Draft Meeting PI = Public Input PC = Public Comment CI = Committee Input CC = Correlating Comment FCR = First Correlating Revision NITMAM = Notice of Intent to Make A Motion 4

The Annual 2019 Revision Process Technical Committee First Draft Meetings: July 2016, Salt Lake City Correlating Committee First Draft Meetings: December 2016, New Orleans Public Comment Closing Date: May 10, 2017 Technical Committee Second Draft Meetings: July 17-21, Charlotte, NC Correlating Committee Second Draft Meetings: November 15-16, Savannah, GA NITMAM Closing Date: February 21, 2018 NITMAM Closing Date: April 4, 2018 NFPA Annual Meeting Adoption: June 2018, Las Vegas Standards Council Approval: July 2018 5

Proposed Global Changes Dissolve NFPA 720 and blend applicable requirements into NFPA 72, for Carbon Monoxide equipment and systems. Change speaker to loudspeaker. Change hearing impaired to deaf. Change visible to visual. Change communication to communications. Change enforcing authority to authority having jurisdiction. Correlate all SI and Standard units for consistency. Elimination of exceptions, where possible. 6

Protected Premises (SIG-IDS) Chapters 3 and 17 Dan O Connor, Chair Jensen Hughes 7

Initiating Devices Key Types of Changes Three categories of changes for Chapter 17 1) Carbon monoxide initiating devices 2) Air-sampling type smoke detectors 3) A few miscellaneous changes PI #468 8

Initiating Devices Carbon monoxide New text was added to incorporate CO devices into Chapter 17 (household applications in Chapter 29 ) 1) CO devices now integrated to the general scope 2) CO devices subject to the concealed location requirements 3) Specific provisions for CO devices in a new section(17.12) PI #591,592,605,606 FR #2010, 2011, 2012 & 2013 9

Initiating Devices Carbon monoxide New Section 17.12 was added to address specific requirements for CO devices, when required by other codes/ordinances 1) Location & mounting 2) CO threshold requirements ANSI/UL 2034 3) Ambient conditions, factors of environment 4) Protection during construction 5) Provisions related to HVAC and smoke control systems PI #607 / FR #2018 10

Air-Sampling Type Smoke Detector New Section 17.7 added to address specific requirements for Air-Sampling Type Smoke Detectors 1) General requirements a) Apply Performance-based design (PBD)criteria b) If not PBD - Each port treated as a spot smoke detector for location and spacing c) Airflow trouble signals required d) Atmospheric contaminant filters listed and per mfg s instructions 2) Pipe Network 3) Installation 4) Air duct applications 5) Electrical Cabinet applications PI #531, 645, 644 FR #2008 11

Air-Sampling Smoke Detector If PBD criteria is not being Applied Then Use Spot Criteria 12

Air-Sampling Piping Network New Section 17.7.3.6.2 added to address piping network 1) Transport time - 120 seconds 2) Design must be based on Fluid Dynamics calculations - Pressure, Volumetric flow, port sensitivity 3) Design Software Listed for MFG s product 4) Treatment of test ports 5) Painting - per MFG s instructions 6) Pipe suitable for the environment 7) Fittings airtight and permanently fixed 8) Exhaust lessor or equal pressure zone 9) Materials, installation, pipe and tubing - per MFG s instructions PI #531, 645, 644 FR #2008 13

Air-Sampling Type Smoke Detector FR-2016 Revised Section 17.7.2.2 to eliminate potential confusion between Air-Sampling Type Smoke Detectors and Spot Smoke Detectors 17.7.2.2 Smoke Spot-type smoke detectors that have provision for field adjustment of sensitivity via a mechanical means shall have an adjustment range of not less than 0.6 percent per foot (1.95 percent per meter) obscuration. Existing requirement may create confusion if it is viewed within the context of high sensitivity aspirated detectors, which have sensitivity settings outside of the normal UL range of 0.5 to 4%/ft PI #373? FR #2016 14

Revisions Regarding Applicable Standards Wording revised so as not to preclude other standards 17.6.1.4 Heat sensing fire detectors shall be listed in accordance with applicable standards such as ANSI/UL 521 Standard for Heat Detectors for Fire Protective Signaling Systems and installed in accordance with their listing. 17.10.2.1 Gas detection equipment shall be listed in accordance with applicable standards such as UL 1484 Standard for Residential Gas Detectors or UL 2075 Standard for Gas and Vapor Detectors and Sensors for the specific gas or vapor it is intended to detect. 17.15.1 Manually actuated alarm-initiating devices shall be listed in accordance with applicable standards such as ANSI/UL 38, Standard for Manual signaling Boxes for Fire Alarm Systems. PI #531, 645, 644 15

Dry Sprinkler System Air Pressure FR-2023 Revised Section 17.17.2.2 to correctly address air pressure monitoring for both high and low differential dry valves 1) Off-normal signal traditionally required to signal a) Pressure increase of 10 psi b) Pressure decrease of 10 psi c) Applicable to systems using 40 psi pressure 2) Low differential systems operating in 10-15 psi range a) Use manufacturer s instructions PI #371, 67, 74 FR 2023 16

Protected Premises (SIG-NAS) Chapters 3 and 18 Robert Schifiliti, Past Chair & Principal RP Schifiliti & Associates 17

TLAs 18

Chapter 18 Notification Appliances Global Changes Change enforcing authority to AHJ FR-2502 Change visible to visual FR-2504 Change speaker to loudspeaker FCR-23 FR #2502, 2504 / FCR #23 19

Chapter 18 Notification Appliances Global Changes 18.1.6 The requirements of Chapters 10, 14, 23, and 24 shall apply to FR-2512 Similar proposals submitted on behalf of SIG- FUN to all other chapters. CC reviewed and submitted notes to reinstate in 2 nd draft. FR #2512 20

Chapter 18, Notification Appliances Voltage Drop Calculations Already required by 7.2.1 (8) TG formed to provide guidance Adds requirement into Ch. 18 Provides examples in Annex A CI # 2510 21

Chapter 18 Notification Appliances Incorporation of Carbon Monoxide New 18.4.3 Distinctive carbon monoxide signal CI-2515 and FCR-1 added T4 for CO 18.4.9.4 modified and new 18.5.5.7.2 : Locate CO per the requirements for detectors or alarms FCR-2 18.5.3.7 Adds strobes for CO use FR-2521 CI #2515 / FCR #2 / FR #2521 22

Chapter 18, Notification Appliances FR-2514 Removes figure of T3 & updates reference to ANSI S3.41 ANY FREQUENCY PERMITTED ANY FREQUENCY PERMITTED ANY FREQUENCY PERMITTED ANY FREQUENCY PERMITTED ANY FREQUENCY PERMITTED ANY FREQUENCY PERMITTED 0.50 sec 0.50 0.50 0.50 0.50 1.50 3000 Hz Piezo 23

800 HZ 2000 HZ 4000 HZ 800 HZ 2000 HZ 4000 HZ 800 HZ 2000 HZ 4000 HZ REPEAT CYCLE THREE TIMES AND FOLLOW WITH VOICE MESSAGE REPEAT CYCLE THREE TIMES AND FOLLOW WITH VOICE MESSAGE 6/2/2017 Modified T-3 RELATIVE FREQUENCY NOT AMPLTUDE ON OFF Courtesy R.P. Schifiliti Associates, Inc., 2016 a1 a2 a3 a1 a2 a3 a1 a2 a3 a b a b a c CYCLE RELATIVE FREQUENCY NOT AMPLTUDE SWEEP 500 4000 HZ ON OFF 500 HZ 4000 HZ 500 HZ 4000 HZ 500 HZ 4000 HZ Courtesy R.P. Schifiliti Associates, Inc., 2016 SOUND FILES 2017 R.P. Schifiliti Associates, Inc.. a b a b a c CYCLE 24

FR-2517 allows ONLY ADSs that DO NOT require intelligibility to be designated by the designer. Designer must designate Acoustically Distinguishable Spaces (ADSs) ADS System Planning & Design ADS Will Have Occupant Notification ADS Will NOT Have Occupant Notification Occupant Notification by Audible Tone Occupant Notification By Tone Alert & Voice Intelligible Voice Required in this ADS Intelligible Voice NOT Required in this ADS 25

Acoustically Distinguishable Spaces (ADSs) Sample ADS plan for a nightclub. 26

Chapter 18, Notification Appliances Visual Signaling Intensity in candela Short duration pulse, high peak intensity Longer duration pulse, shorter peak intensity Time duration 27

Chapter 18, Notification Appliances Visual Signaling INTENSITY IN CANDELA (cd) Short duration pulse, high peak intensity Long duration pulse, low peak intensity TIME DURATION 28

Chapter 18, Notification Appliances Visual Signaling INTENSITY IN CANDELA (cd) 18.5.3.2 Changed in 2016: Max. pulse duration changed from 200 ms (0.2 s) to 20 ms (0.02 s) (100 ms for direct viewing) Temporary change pending research verification and validation. Does NOT apply to direct signaling used in corridors. TIME DURATION 29

Chapter 18, Notification Appliances Visual Signaling 18.5.3.2 FR-2519: Remove 40% duty cycle requirements as being redundant Remove allowance for 100 ms long pulse duration for direct viewing FR #2519 30

Chapter 18, Notification Appliances What's on the Radar Screen for Visual Signaling? 18.5 CI-2539 Complete rewrite of visual appliance performance requirements Measure ambient light or use table for new construction Existing tables stay for Zenon strobes (<1 ms) > 1ms, intensity may vary with pulse duration >100 ms requires intensity multiplier CI #2539 31

Chapter 18, Notification Appliances What's on the Radar Screen for Visual Signaling? 18.5 UL Research program continues Data not yet published New work to be presented at July TC meeting 32

Emergency Communications Systems (SIG-ECS) Chapters 3 and 18 William Koffel, Chair Koffel & Associates 33

Bid Documents (7.3.3) Architect/Engineer shall be qualified IAW 10.5.1 Bid documents shall include: Performance criteria meeting needs of owner, occupant, and AHJ Intended performance of installing contractor Ensure that areas will be finished out in a manger that intelligibility will be achieved PI # 393/ FR # 548 34

Control Unit Listing For MNS (24.3.10) Equipment shall be listed in accordance with: UL 864 UL 2017 UL 2572 Scope of UL 2017 is to broad in that it includes nonemergency equipment PI 681 submitted by UL proposed to delete UL 864 as well PI # 681/FR # 508 35

Risk Analysis (24.3.12.1.1) Permits acceptance of previously prepared risk analysis for new or renovated facilities PI # 508/FR # 525 36

Two Way Communication Enhancement Systems (24.3.14.9) Pathway survivability requirements deleted since provisions are in NFPA 1221 PI # 430/FR # 511 37

Alert tones (24.4.8.4) Where the system is used to transmit partial evacuation instructions, the alert tone specified in 24.4.2.1 followed by a message (or messages where multi-channel capability is used) shall be provided. Requires alert tones when partial evacuation is used PI # 776 / FR # 517 38

Alternative Methods (A.24.5.4.1) An example of an alternate method could include an attendant monitored system listed to UL 2017, The addition to the annex seeks to provide additional clarity by providing an example of an alternate method with cited justification from other referenced standards. PI # 423 / FR # 544 39

Testing & Maintenance (SIG-TMS) Chapters 3 and 14 Richard Heffernan, Principal SDi 40

Proposed Changes SIG-TMS Adds new section after 4.3 2.3.3 IEEE Publications. Institute of Electrical and Electronics Engineers, 3 Park Avenue, 17th Floor, New York, NY 10016-5997. IEEE 450, Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications, 2010. IEEE 485, Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications, 2010. IEEE 1106, Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications, 2005. PI #138 / FR #4503 41

Proposed Changes SIG-TMS 3.3.31* Battery. 3.3.31.1 Battery Capacity. 3.3.31.2 Battery Charger. 3.3.31.2.1 Float Charge. 3.3.31.2.2 Fully Charged. Add definitions: 3.3.31.2.3 State of Charge (SOC). 3.3.31.2.4 Trickle Charge. 3.3.31.3 Battery Load Test. 3.3.31.4 Battery Unit. 3.3.31.5 Rechargeable Battery. Reason: Battery definitions added per the recommendations of the IEEE Stationary Battery Committee and NFPA Battery Task Group to introduce correct battery terminology. FR #4504 42

Proposed Changes SIG-TMS FR 4529 Adds New Section 3.3.40 Cell. The basic electrochemical unit, characterized by an anode and a cathode, used to receive, store, and deliver electrical energy. [ 70: 480] (SIG-TMS) 3.3.40.1 Primary (Dry) Cell. A non-rechargeable electrochemical cell requiring periodic replacement, such as a 9-volt alkaline cell. (SIG-FUN) 3.3.40.2 Starved Electrolyte Cell. A cell in which liquid electrolyte is immobilized, also known as an absorbed glass mat (AGM) cell or agelled electrolyte cell (gel cell). (SIG-TMS) PI #140 / FR #4529 43

Proposed Changes SIG-TMS FR 4529, (Cont) 3.3.40.2.1 Absorbed Glass Mat (AGM) Cell. A cell in which the liquid electrolyte is immobilized in fiberglass or polymeric fiber separators. (SIG-TMS) 3.3.40.2.2 Gelled Electrolyte Cell (Gel Cell). A cell in which the electrolyte is immobilized by addition of a gelling agent. (SIG-TMS) 3.3.40.3 Unit (Multi-Cell). Multiple cells in a single container, such as a 12-volt unit composed of six 2-volt cells. (SIG-TMS) 3.3.40.4* Valve-Regulated Lead-Acid (VRLA) Cell. A sealed lead-acid cell with a valve that opens to the atmosphere when the internal pressure in the cell exceeds atmospheric pressure by a preselected amount. (SIG-TMS) PI #140 / FR #4529 44

Proposed Changes SIG-TMS FR 4533, PI s 522, 649, 134, 149, 519, 13 FR 4534, PI s 630, 451, 547, 301, 180, 7, 133, 338, 254, 672, 739, 135, 520, 521 Multiple Changes Throughout Table Reason: The Technical Committee makes multiple changes to this table under guidance from the Correlating Committee, to increase clarity of requirements and to include new battery technologies. 45

Proposed Changes SIG-TMS Add new text: 3.3.140* Inspection and Testing Report Recommendation. A suggestion that is provided within the scope of the report but is not required and does not rise to the level of a deficiency. The Technical Committee makes multiple changes to this table under guidance from the Correlating Committee, to increase clarity of requirements and to include new battery technologies. Reason: To provide additional clarification to both the building owner and service provider that recommendations are permitted but not required to be acted upon by this Code. PI #341 / FR #4509 46

Proposed Changes SIG-TMS FR 4509 (con t) Add new text: A.3.3.140* Inspection and Testing Report Recommendation. A recommendation should not be considered a required system deficiency or impairment repair, but could become one in the future for example, manufacturer suggested device replacements, executive software upgrades, corroded electrical box/fitting/raceway replacement, and other similar items not directly impacting a system s ability to complete its intended function at the point in time when the recommendation was made. Reason: To provide additional clarification to both the building owner and service provider that recommendations are permitted but not required to be acted upon by this Code. PI #341 / FR #4509 47

Proposed Changes SIG-TMS Add new text: 14.1.6 The inspection, testing, and maintenance required by this chapter and NFPA 25 shall be coordinated so that the system operates as intended. Reason: This new section clarifies this coordinated effort, namely that the functions common to both systems operate as intended. FR #4507 48

Proposed Changes SIG-TMS Add new text: 14.2.2.2.3 During required testing, service, or maintenance of fire alarm systems, inspection, service, or testing personnel shall be permitted to make note of opportunities to improve or enhance existing system performance. 14.2.2.2.3.1 If opportunities to improve or enhance existing system performance are noted, such observations shall be communicated to the system owner via official correspondence in the inspection and testing report or in a separate document. 14.2.2.2.3.2 The system owner shall only be required to consider, but shall not be required to authorize, implementation of any recommendations. Reason: This new section was added to provide additional clarification to both the building owner and service provider that recommendations are permitted but not required to be acted upon by this Code. PI #342 / FR #4508 49

Proposed Changes SIG-TMS Revise text (Table 14.3.1): Valve-Regulated Lead Acid Batteries Semiannual Inspection Primary Dry Cell Semiannual Inspection Nickel Cadmium and Sealed Lead Acid - DELETED Reason: Revised per the recommendations of the IEEE StationaryBattery Committee and NFPA Battery Task Group to introduce correct battery terminology. PI #131, 134, 149, 519, 522 & 649 FR #4508 50

Proposed Changes SIG-TMS Add new text: 14.6.2.5 The system shall be clearly identified by a placard, sticker, or other means to indicate the next regularly scheduled inspection, test, or maintenance. Exception: If the devices have been tested as part of the normal carbon monoxide alarm testing, the existing means of indicating the next regularly scheduled inspection period shall be permitted. Reason: Provides new language to incorporate NFPA 720 requirements into Chapter 14 in accordance with the guidance of the Correlating Committee. PI #360 / FR #4508 51

Proposed Changes SIG-TMS New 720 Requirements! 14.4.3.5 Testing of CO System Detectors. For all carbon monoxide system detectors installed after January 1, 2012, carbon monoxide tests shall be performed at initial acceptance and annually by the introduction of carbon monoxide into the sensing chamber or element. 14.4.3.5.1 An electronic check (e.g., magnets, analog values, and so on) shall comply with the requirements of 14.4.3.5.1. PI #356 / FR #3510 52

Proposed Changes SIG-TMS New 720 Requirements! FR 4511, PI 357 FR 4513, PI 359 FR 4514, PI 360 Reason: The Technical Committee provides new language to incorporate NFPA 720 requirements into Chapter 14 in accordance with the guidance of the Correlating Committee. 53

Proposed Changes SIG-TMS New 720 Requirements! Adds New Section 14.4.5.4.2 Carbon monoxide alarms shall be replaced when either the end-oflife signal is activated or the manufacturer s replacement date is reached. Reason: The Technical Committee adds this section in accordance with guidance from the Correlating Committee to incorporate NFPA 720 into NFPA 72. PI #358 / FR #5050 54

Proposed Changes SIG-TMS New 720 Requirements! FR 4515 Adds Annex (H) Material Reason: The Technical Committee provides new language to incorporate NFPA 720 requirements into Chapter 14 in accordance with the guidance of the 720/72 Consolidation Task Group. FR 4519 Removes Annex material Reason: Removes Annex material due to NFPA 720 being withdrawn. PI #378 / FR #4515, 4519 55

Proposed Changes SIG-TMS FR 4522, FR 4523 The Technical Committee edits the text to be consistent with the new proposed definition of official correspondence and adds the word deficiency to be consistent throughout the section. FR 4524 The Technical Committee edits text to be consistent with the new proposed definition of official correspondence, and provides new language in the Annex to address the need to take into account manufacturer tolerances for equipment operability, especially where environmental conditions are not optimal. PI #15, 16, 26 & 209 FR #4522, 4523 & 4524 56

Proposed Changes SIG-TMS New Section 3.3.84 Electromechanical Releasing Device. Mechanical devices, including fusible links, electrically monitored for contact closure to initiate a signa to the FACU. Reason: The Technical Committee clarifies the limited use of this device and technology and provides a definition for a previously undefined term FR #4520 57

Proposed Changes SIG-TMS Editorial Clarification 14.2.10.1 A test plan shall be written developed to clearly establish the scope of the testing for the fire alarm or signaling system. Reason: The Technical Committee edits the text to clarify that this section is to develop a test plan by replacing WRITTEN with DEVELOPED. PI #31 / FR #4521 58

Proposed Changes SIG-TMS FR 4505 Correlation in Section No. D.3.2.3 Reason: The Technical Committee revises the text to replace panel with unit and thereby correlate with the definition of an Emergency Communications System Control Unit in Chapter 3. FR 4506 Editorial Change in Sections 14.2.2.2.3, 14.2.2.2.4 Reason: The Technical Committee removed the words "in writing" because they were found to be unnecessary. PI #340 / FR #4505 & 4506 59

Proposed Changes SIG-TMS FR 4528 Correlation Issue in Section No. F.1 Reason: The Technical Committee edits the text in line with a review conducted by the Correlating Committee and for consistency with Chapter 12. Class R and Class S have been removed from Chapter 12 and Class N has been added. The above text will harmonize accordingly. FR 4531 Table Modification in Section No. A.14.6.2.4 Reason: The Technical Committee modifies column GG and replaces "exterior strobe" with "exterior visible notification appliance". This is done as part of the Correlating Committee Task Group on terms, the term "light" and strobe was reviewed throughout the entire document for proper use. In some cases it refers to a physical appliance while other sections use it to refer to the output of an appliance. In this section the term is for an appliance and the proper term "visible notification appliance" should be used. PI #717 / FR #4528 & 4531 60

Proposed Changes SIG-TMS FR 4526 Editorial Change D.3.2 Emergency Communication Communications Equipment. FR 4525, PI 465 Editorial Change Reason: Correlate with task group work done by the Correlating Committee FR 4527 Removes redundant language in Section No. D.2.5.4 PI #466 / FR #4526 & 4527 61

Questions? 62