563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Similar documents
563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

697C (60 HZ) Sizes 018 thru 060

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data PA13NA PA13PA FEATURES AND BENEFITS

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

R4H4. Product Specifications

R4H4. Product Specifications

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

WCH5**4. Product Specifications

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

N4H4. Product Specifications

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

A 14 SEER Heat Pump with R---410A Refrigerant Series

N4A6. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency. S S Reliability

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

Product Data. Efficiency

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

R 410A Ducted Horizontal Air Conditioner

Product Data INDUSTRY LEADING FEATURES / BENEFITS

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. Efficiency

Advance Product Data

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Efficiency

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

2 shp 13 lc 1 36 t - 1 a

Commercial High-Efficiency Condensing Units

TECHNICAL SPECIFICATIONS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

PAJ3. Product Specifications

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

TECHNICAL SPECIFICATIONS

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Product Data. Efficiency

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Installation Instructions

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Product Data. Fig. 1 - Unit 50VR -A

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

WJH4 Product Specifications

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Transcription:

12 SEER ELECTRIC AIR CONDITIONER 563C (60 Hz) Sizes 024 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today including SEER ratings of at least 12.0 when combined with specific Bryant equipment. All models are listed with UL, c-ul, ARI, CEC, and CSA-EEV. The 563C meets the Energy Star guidelines for energy efficiency. AVAILABLE OPTIONS UNIT DESIGN Copper tube, enhanced sine wave aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan for easy removal of water, dirt, and leaves. ELECTRICAL RANGE All units are offered in single phase 208/230v. The 036 through 060 sizes are offered in 208/230v 3 phase. WIDE RANGE OF SIZES Available in 6 nominal sizes from 024 through 060 to meet the needs of residential and light commercial applications. COMPRESSOR This unit features a scroll compressor, which is significantly more efficient than conventional compressors. Its simple design offers improved reliability and each compressor is mounted on rubber isolators for additional sound reduction. Scroll compressors start under most system loads, minimizing the need for start assistance components. For improved serviceability, units are equipped with a compressor terminal plug. Continuous operation is approved down to 55 F (12.8 C) in the cooling mode. (See cooling performance tables.) Operation down to 0 F or 20 F is approved when low-ambient requirements are met. WEATHER-PROTECTIVE CABINET The access panels and top are protected with a galvanized coating, then treated with a layer of zinc phosphate to which a modified polyester powder coating is applied and baked on. This provides each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rustresistant, quality appearance. TOTALLY ENCLOSED FAN MOTOR Means greater reliability under adverse weather conditions and dependable performance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. The motor was tested and qualified under extreme conditions to ensure greatest reliability. APPLICATION VERSATILITY The 563C can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. EASY SERVICEABILITY One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. COMPRESSOR PROTECTION Includes a suction tube accumulator on 048 and 060 sizes that reduces the amount of liquid refrigerant reaching the compressor. All compressors are protected by internal temperature and current sensitive overloads. An internal pressure relief is provided for high-pressure protection to the refrigerant system. LIMITED WARRANTY Standard 1-year warranty on all parts. Additional 4-year warranty on compressor. Form No. PDS 563C.24.11

DIMENSIONS M AIR IN AIR DISCHARGE 30" SQ AIR DISCHARGE N 20" FIELD POWER SUPPLY CONN 7/ 8-IN. DIA HOLE WITH 1 1 / 8-IN. DIA KNOCKOUT AND 1 3 / 8-IN. DIA KNOCKOUT AIR IN 3 /8-IN. DIA TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN 27 1 /16" AIR IN 29 9 /16" B P FIELD CONTROL SUPPLY CONN 7 / 8-IN. DIA HOLE 3 / 8-IN. DIA LIQUID LINE CONN AIR DISCHARGE 6 1 /2" AIR IN 23 1 /2" D DIA VAPOR LINE CONN 1 1 /4 2 7 /8 C 27 1 /4" 29 3 /4" NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F, max. 125 F. 3. Series designation is the 14th position of the unit model number. 4. Center of gravity. A97076 DIMENSIONS (IN.) UNIT SIZE SERIES B C D M N P MINIMUM MOUNTING PAD DIMENSIONS 024 B 23-15/16 3-3/16 5/8 14-3/4 14 10 30 x 30 030 B 27-15/16 3-3/16 3/4 14-3/4 14 11 30 x 30 036 D 33-15/16 3-3/16 3/4 14-3/4 14 13 30 x 30 036 C, D 27-15/16 3-3/16 3/4 14-3/4 14 11 30 x 30 042 D 39-15/16 3-1/4 7/8 14-3/4 14 15 30 x 30 042 C, D 33-15/16 3-1/4 7/8 14-3/4 14 13 30 x 30 048 E, F 33-15/16 3-1/4 7/8 15-1/2 14-3/4 13 30 x 30 060 E, F 39-15/16 3-1/4 7/8 15-1/2 14-3/4 15 30 x 30 2

RECOMMENDED TUBE DIAMETERS LIQUID TUBE DIAMETER (IN.) VAPOR TUBE DIAMETER (IN.) UNIT SIZE 0 to 50 Ft Tube Length Long-Line Applications* 0 to 50 Ft Tube Length Long-Line Applications* (Maximum Diameter) 024 5/8 3/4 030, 036 3/4 7/8 3/8 3/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 * For tube sets between 50 and 175 ft, consult Residential s Split Long-Line Application Guideline. CHECK-FLO-RATER PISTON CHART PISTON* UNIT SIZE-SERIES IDENTIFICATION NO. 024-B 61 030-B 70 036-C, D 73 042-D 84 042- C, D 82 048-E, F 90 060-E, F 104 * Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. CHARGING SUBCOOLING (TXV-TYPE EXANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING ( F). 024-B 13 030-B 11 036-D 13 036-C, D 14 042-D 9 042-C, D 12 048-E, F 11 060-E, F 11 UNITARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. As an ENERGY STAR Partner, Bryant Heating & s has determined that this product meets the ENERGY STAR guidelines for energy efficiency. REGISTERED QUALITY SYSTEM 3

See notes on page 5. SPECIFICATIONS UNIT SIZE-SERIES 024-B 030-B 036-C/D 036-C/D 042-C/D 042-C/D Operating Weight (Lb) 147 161 169 169/173 186/180 180/186 ELECTRICAL Volts Hertz Phase 208/230 60 1 208/230 60 3 208/230 60 1 208/230 60 3 Operating Voltage Range* 187 253 Compressor Rated Load Amps 11.4 15.0 16/16.7 11.4/10.6 20.0/18.6 13.9/13.4 Locked Rotor Amps 56.0.5 88.0/97.0 77.0/75.0 104.0/115.0 88.0/90.0 Condenser Fan Motor Full Load Amps 0.5 0.8 1.1 1.4 1.1 1.4 Min Ampacity for Wire Sizing 14.8 19.6 21.1/22.0 15.7/14.7 26.1/24.5 18.8/18.2 Min Wire Size (60 C Copper) AWG 14 14 12 14 10 14 Min Wire Size (75 C Copper) AWG 14 14 12 14 10 14 Max Wire Length (Ft) (60 C Copper) 53 39 55/ 49/53 74/80 41/41 Max Wire Length (Ft) (75 C Copper) 50 37 52/54 47/50 70/76 39 Max Branch Circuit Fuse Size** 25 30 30 20 40 25 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Manufacturer Copeland Copeland/ Millennium Copeland/ Millennium Copeland/ Millennium Copeland/ Millennium Temperature and Current Protection Internal Line Break Refrigerant Type R-22 Amount (Lb) 5.25 6.25 6.50 6.50/7.10 6.75 6.75/8.38 CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 12.4 14.9 14.9 14.9/18.7 18.7 18.7/22.4 Fins per In. Rows Circuits 25 1 2 25 1 2 25 1 2 25 1 2/ 25 1 3 25 1 3 25 1 3/ 25 1 4 Fan Motor (PSC) HP and RPM 1/15 and 820 1/8 and 825 1/5 and 825 1/4 and 1125 1/5 and 825 1/4 and 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 1800 2500 2800 3300 2800 3300 OPTIONAL EQUIPMENT Coastal Filter KAACF0401MED KAACF0501LRG Time-Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Standard/ KSACY0101AAA KSACY0101AAA Standard/ KSACY0101AAA KSACY0101AAA Crankcase Heater KAACH1201AAA Inlet Grille Kit KSABG2004CMD/ KSABG1704CMD/ KSABG2304CMD/ KSABG2004CMD/ KSABG1504CMD KSABG1704CMD KSABG1704CMD KSABG2004CMD KSABG2004CMD KSABG2304CMD Start Assist Capacitor/Relay Type KSAHS1501AAA N/A KSAHS1501AAA N/A Start Assist PTC Type KAACS0201PTC N/A KAACS0201PTC N/A Sound Hood KSASH1801COP KSASH0601COP TXV (RPB) KAATX0301RPB KAATX0401RPB KAATX0501RPB TXV (Hard Shutoff) KSATX0601HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8083S (RCD) P502-8163S (RCD) Evaporator Freeze Thermostat KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Control*** N/A 32LT660004 (RCD) Ball Bearing Fan Motor N/A HC38GE231 (RCD) HC38GE231(RCD) HC40GE232(RCD) HC38GE231(RCD) HC40GE232(RCD) Thermostat Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B Thermostat Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermidistat TM Control Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 4

SPECIFICATIONS Continued UNIT SIZE-SERIES 048-E/F 048-E 060-E/F 060-E Operating Weight (Lb) 231/237 237 260/264 264 ELECTRICAL Volts Hertz Phase 208/230 60 1 208/230 60 3 208/230 60 1 208/230 60 3 Operating Voltage Range* 187 253 Compressor Rated Load Amps 20.2/24.3 15.1 28.8 17.3 Locked Rotor Amps 137.0/140.0 91.0 169.0/175.0 123.0 Condenser Fan Motor Full Load Amps 1.1/1.4 1.4 1.4 1.4 Min Ampacity for Wire Sizing 26.4/31.9 20.2 37.4 23.0 Min Wire Size (60 C Copper) AWG 10/8 12 8 12 Min Wire Size (75 C Copper) AWG 10/8 12 8 12 Max Wire Length (Ft) (60 C Copper) 74/97 60 82 55 Max Wire Length (Ft) (75 C Copper) 70/59 78 52 Max Branch Circuit Fuse Size** 40/50 30 60 40 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Manufacturer Copeland/Millennium Copeland Copeland/Millennium Copeland Temperature and Current Protection Internal Line Break Refrigerant Type R-22 Amount (Lb) 10.45 12.88 CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 18.7 22.4 Fins per In. Rows Circuits 20 2 5 23 2 6 Fan Motor (PSC) HP and RPM 1/5 and 825/1/4 and 1125 1/4 and 1125 1/4 and 1125 1/4 and 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 2800/3300 3300 3300 OPTIONAL EQUIPMENT Coastal Filter KAACF0501LRG Time-Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA/Standard KSACY0101AAA KSACY0101AAA/Standard KSACY0101AAA Crankcase Heater Standard Inlet Grille Kit KSABG2004CMD KSABG2004CMD KSABG2304CMD KSABC2304CMD Start Assist Capacitor/Relay Type KSAHS1601AAA N/A KSAHS1601AAA N/A Start Assist PTC Type KAACS0201AAA N/A KAACS0201AAA N/A Sound Hood KSASH0601COP KSASH2101COP TXV (RPB) KAATX0601RPB KAATX0701RPB TXV (Hard Shutoff) KSATX0701HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8163S (RCD) (Standard on D only) Evaporator Freeze Thermostat KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Control*** 32LT660004 (RCD) Ball Bearing Fan Motor HC40GE232 (RCD) Thermostat Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat,1-Stage Cool TSTATBBNAC01-B Thermostat Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermidistat TM Control Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time-delay fuse or circuit breaker. Charge quantity is for 15 ft of interconnecting tubing. For tubing lengths longer than 15 ft, add 0.6 oz. of refrigerant per ft of tube length in excess of 15 ft. Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 048 and 060). Do not use hard shutoff TXV with liquid solenoid valve. *** Fan motor with ball bearings required. N/A Not applicable in this application. NOTES: All motors/compressors contain internal overload protection. Copper wire must be used from service disconnect to unit. Control circuit is 24v on all units and requires external power source. 5

ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No Low-Ambient Controller, MotorMaster Control or Low-Ambient Pressure Switch Yes No No Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV * For tubing line sets between 50 and 175 ft, refer to Residential s Split s Long-Line Application Guideline. Only when low-pressure switch is used. Required for Low-Ambient Controller (full modulation feature) and MotorMaster Control only. No See Long-Line Application Guideline Ball Bearing Fan Motor Yes No No No ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster Control has been added. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. SUGGESTED USE: In geographic areas where salt damage could occur. 3. Compressor Start Assist Capacitor/Relay Type Start capacitor and start relay gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Installations where Liquid-Line Solenoid Valve has been added. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a soft boost to compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. (Thermostat control standard on 048 and 060 sizes.) SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations. 6. Cycle Protector Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High rise applications. 7. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where Winter Start Control has been added. 8. Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow. (Filter drier standard on 048 and 060 sizes.) SUGGESTED USE: All split-system air conditioners. 9. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Installations exposed to very dirty outdoor air. Installations where condenser inlet air temperature exceeds 125 F (51.7 C). 10. Inlet Grille Kit A field-installed enhanced inlet grille to replace the standard inlet grille on residential air conditioners and heat pumps. SUGGESTED USE: For greater protection against inclement weather, incidental damage, and vandalism. 11. Liquid-Line Solenoid Valve An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. NOTE: Compressor Start Assist Capacitor/Relay Type must also be used. SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. In certain long-line applications. Refer to Residential s Split s Long-Line Application Guideline. 6

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 12. Low-Ambient Controller Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits (approximately 100 F high and 60 F low). The control will maintain working head pressure at low-ambient temperatures down to 0 F when properly installed. SUGGESTED USE: operation at outdoor temperatures below 55 F (12.8 C). 13. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F when properly installed. SUGGESTED USE: operation at outdoor temperatures below 55 F (12.8 C). 14. Low-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Provides protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to dirty air. All commercial installations. 15. MotorMaster Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F, it maintains condensing temperature at 100 F ± 10 F. SUGGESTED USE: operation at outdoor temperatures below 55 F. All commercial installations. 16. Outdoor Air Temperature Sensor A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat. SUGGESTED USE: All Bryant programmable thermostats. 17. Sound Hood Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2 dba. SUGGESTED USE: installed closer than 15 ft to quiet areas bedrooms, etc. installed between 2 houses less than 10 ft apart. 18. Thermostatic Expansion Valve (TXV) A modulating flow control valve which meters refrigerant flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. Do not use hard shutoff TXV with Liquid-Line Solenoid Valve. SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. Required for use on all zoning systems. 19. Time-Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. Required for use on all zoning systems. 20. Winter Start Control An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions. SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added. SOUND POWER (dba) UNIT SOUND OCTAVE BAND CENTER FREQUENCY (Hz) SIZE LEVEL (dba) 125 250 500 1000 2000 4000 8000 024-B 78 49.5 58.0 64.0 71.0 64.5 60.5 56.5 030-B 78 54.0 61.0 66.0 70.5 66.0.5 58.0 036-D (single phase) 82 54.5 66.5 68.0 71.0 77.0 70.5 61.5 036-D 82 49.5 61.0 70.5 73.5 65.5.5 54.0 036-C 82 52.0 58.5 68.0 78.0 68.0 64.0 58.0 042-D (single phase) 82 55.0 69.0.0 70.5 76.5 68.5 61.5 042-D 82 49.5 60.5.5.0 66.0 63.0 56.0 042-C 82 54.0 61.0.5 73.5 71.0 63.5 58.5 048-E 82 51.5 58.5 65.5 66.5 64.0 64.5 61.5 048-F 82 52.5.5.0 70.0 64.5 63.5 58.5 060-E 82 58.0 69.0.0 75.0 69.5 70.0 64.5 060-F 82 58.5 66.0 71.5 75.0 68.5 68.0 60.5 7

COMBINATION RATINGS UNIT SIZE-SERIES 024-B 030-B See notes on page 13. SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER CC5A/CD5AA024* 23,000 NONE 12.00 12.00 12.00 10.80 CC5A/CD5AA030 23,400 NONE 12.10 12.10 12.10 10.90 CC5A/CD5AW024 23,000 NONE 12.00 12.00 12.00 10.80 CC5A/CD5AW030 23,400 NONE 12.10 12.10 12.10 10.90 CE3AA024 23,400 NONE 12.00 12.00 12.00 10.90 CE3AA030 23,600 NONE 12.10 12.10 12.10 11.00 CF5AA024 23,400 NONE 12.00 12.00 12.00 10.90 CK3BA024 23,000 NONE 12.00 12.00 12.00 10.80 CK3BA030 23,400 NONE 12.10 12.10 12.10 10.95 CK5A/CK5BA024 23,000 NONE 12.00 12.00 12.00 10.80 CK5A/CK5BA030 23,400 NONE 12.10 12.10 12.10 10.95 CK5A/CK5BW024 23,000 NONE 12.00 12.00 12.00 10.80 CK5A/CK5BW030 23,400 NONE 12.10 12.10 12.10 10.95 F(A,B)4AN(F,C)024 23,200 TDR 12.00 12.00 10.90 F(A,B)4AN(F,C)030 23,600 TDR 12.20 12.20 11.15 FC4BNF024 23,200 TDR & TXV 12.00 10.90 FC4BNF030 23,600 TDR & TXV 12.20 11.15 FC4BNF033 24,000 TDR & TXV 12.40 11.35 FF1(A,B,C)NA024 23,200 TDR 12.00 12.00 10.80 FF1(A,B,C)NA030 23,400 TDR 12.20 12.20 11.05 FG3AAA024 23,000 NONE 11.80 11.80 11.80 10.65 FK4CNF001 23,800 TDR & TXV 13.00 12.30 FK4CNF002 23,800 TDR & TXV 13.50 12.40 FK4CNF003 23,800 TDR & TXV 14.00 12.70 COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.75 CC5A/CD5AA030 23,400 TDR 13.00 13.00 11.95 CC5A/CD5AW024 23,200 TDR 13.00 13.00 11.75 CC5A/CD5AW030 23,400 TDR 13.00 13.00 11.95 CE3AA024 23,400 TDR 13.00 13.00 11.80 CE3AA030 23,600 TDR 13.00 13.00 12.05 CK3BA024 23,200 TDR 13.00 13.00 11.85 CK3BA030 23,200 TDR 13.00 13.00 12.10 CK5A/CK5BA024 23,200 TDR 13.00 13.00 11.85 CK5A/CK5BA030 23,200 TDR 13.00 13.00 12.10 CK5A/CK5BW030 23,200 TDR 13.00 13.00 12.10 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.65 CC5A/CD5AA030 23,400 TDR 13.00 13.00 11.95 CC5A/CD5AW024 23,200 TDR 13.00 13.00 11.65 CC5A/CD5AW030 23,400 TDR 13.00 13.00 11.95 CK3BA024 23,200 TDR 13.00 13.00 11.65 CK3BA030 23,400 TDR 13.00 13.00 11.95 CK5A/CK5BW030 23,400 TDR 13.00 13.00 11.95 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.65 CC5A/CD5AA030 23,400 TDR 13.00 13.00 11.95 CC5A/CD5AW024 23,200 TDR 13.00 13.00 11.65 CC5A/CD5AW030 23,400 TDR 13.00 13.00 11.95 CK3BA024 23,200 TDR 13.00 13.00 11.65 CK3BA030 23,400 TDR 13.00 13.00 11.95 CK5A/CK5BW024 23,200 TDR 13.00 13.00 11.65 CK5A/CK5BW030 23,400 TDR 13.00 13.00 11.95 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.65 CC5A/CD5AA030 23,400 TDR 13.00 13.00 11.95 CC5A/CD5AW024 23,200 TDR 13.00 13.00 11.65 CC5A/CD5AW030 23,400 TDR 13.00 13.00 11.95 CK3BA024 23,200 TDR 13.00 13.00 11.95 CK3BA030 23,400 TDR 13.00 13.00 12.15 CK5A/CK5BW024 23,200 TDR 13.00 13.00 11.95 CK5A/CK5BW030 23,400 TDR 13.00 13.00 12.15 CC5A/CD5AA030* 29,000 NONE 12.00 12.00 12.00 10.70 CC5A/CD5AA036 29,600 NONE 12.20 12.20 12.20 11.15 CC5A/CD5AW030 29,000 NONE 12.00 12.00 12.00 10.70 CD5AW036 29,600 NONE 12.20 12.20 12.20 11.15 CE3AA030 29,000 NONE 12.00 12.00 12.00 10.85 CE3AA036 29,600 NONE 12.20 12.20 12.20 10.95 CF5AA036 29,600 NONE 12.20 12.20 12.20 11.05 CK3BA030 29,000 NONE 12.00 12.00 12.00 10.75 CK3BA036 29,600 NONE 12.20 12.20 12.20 11.15 CK5A/CK5BA030 29,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA036 29,600 NONE 12.20 12.20 12.20 11.15 CK5A/CK5BN036 27,600 NONE 12.20 12.20 12.20 11.15 CK5A/CK5BW030 29,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BW036 29,600 NONE 12.20 12.20 12.20 11.15 F(A,B)4AN(F,C)030 29,200 TDR 12.10 12.10 10.90 F(A,B)4AN(F,C)036 29,600 TDR 12.00 12.00 10.85 FC4BNF030 29,200 TDR & TXV 12.10 10.90 FC4BNF036 29,600 TDR & TXV 12.00 10.85 8

COMBINATION RATINGS Continued UNIT SIZE-SERIES 030-B 036-C, D See notes on page 13. SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER FC4BNF033 30,000 TDR & TXV 12.50 11.20 FF1(B,C,D)NA030 29,000 TDR 12.00 12.00 10.85 FG3AAA036 29,600 NONE 12.00 12.00 12.00 10.85 FK4CNF001 29,400 TDR & TXV 13.00 11.80 FK4CNF002 29,400 TDR & TXV 13.00 11.90 FK4CNF003 29,800 TDR & TXV 13.50 12.35 FK4CNF005 30,000 TDR & TXV 14.00 12.85 COILS + 333(B,J)AV036030 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 13.00 13.00 11.35 CC5A/CD5AA036 29,600 TDR 13.50 13.50 11.90 CC5A/CD5AW030 29,000 TDR 13.00 13.00 11.35 CD5AW036 29,600 TDR 13.50 13.50 11.90 CE3AA030 29,000 TDR 13.00 13.00 11.50 CE3AA036 29,600 TDR 13.20 13.20 11.65 CK3BA030 29,000 TDR 13.00 13.00 11.45 CK3BA036 29,600 TDR 13.50 13.50 12.00 CK5A/CK5BA030 29,000 TDR 13.00 13.00 11.45 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.00 CK5A/CK5BN036 27,600 TDR 13.00 13.00 11.85 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.45 COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 13.00 13.00 11.35 CC5A/CD5AA036 29,600 TDR 13.50 13.50 11.90 CC5A/CD5AW030 29,000 TDR 13.00 13.00 11.35 CD5AW036 29,600 TDR 13.50 13.50 11.90 CE3AA030 29,000 TDR 13.00 13.00 11.50 CE3AA036 29,600 TDR 13.20 13.20 11.65 CK3BA030 29,000 TDR 13.00 13.00 11.60 CK3BA036 29,600 TDR 13.50 13.50 12.20 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.60 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.20 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 12.80 12.80 11.35 CC5A/CD5AA036 29,600 TDR 13.00 13.00 11.85 CC5A/CD5AW030 29,000 TDR 12.80 12.80 11.35 CD5AW036 29,600 TDR 13.00 13.00 11.85 CK3BA030 29,000 TDR 12.50 12.50 11.25 CK3BA036 29,600 TDR 13.00 13.00 11.85 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.25 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.85 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 12.80 12.80 11.35 CC5A/CD5AA036 29,600 TDR 13.00 13.00 11.85 CC5A/CD5AW030 29,000 TDR 12.80 12.80 11.35 CD5AW036 29,600 TDR 13.00 13.00 11.85 CK3BA030 29,000 TDR 12.80 12.80 11.25 CK3BA036 29,600 TDR 13.00 13.00 11.85 CK5A/CK5BA036 29,600 TDR 13.00 13.00 11.85 CK5A/CK5BW030 29,000 TDR 12.80 12.80 11.25 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 12.80 12.80 11.35 CC5A/CD5AA036 29,600 TDR 13.00 13.00 11.85 CC5A/CD5AW030 29,000 TDR 12.80 12.80 11.35 CD5AW036 29,600 TDR 13.00 13.00 11.85 CK3BA030 29,000 TDR 12.80 12.80 11.35 CK3BA036 29,600 TDR 13.00 13.00 11.95 CK5A/CK5BW030 29,000 TDR 12.80 12.80 11.35 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.95 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA030 29,000 TDR 12.50 12.50 11.20 CK3BA036 29,600 TDR 13.00 13.00 11.80 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.80 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CK3BA030 29,000 TDR 13.00 13.00 11.60 CK3BA036 29,600 TDR 13.00 13.00 12.20 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.60 CK5A/CK5BW036 29,600 TDR 13.00 13.00 12.20 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK3BA030 29,000 TDR 13.00 13.00 11.55 CK3BA036 29,600 TDR 13.00 13.00 12.15 CK5A/CK5BW036 29,600 TDR 13.00 13.00 12.15 CC5A/CD5AA036* 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AA042 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AW036 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AW042 35,000 NONE 12.00 12.00 12.00 10.70 CE3AA036 35,000 NONE 11.80 11.80 11.80 10.65 CE3AA042 35,400 NONE 12.10 12.10 12.10 10.80 CF5AA036 35,000 NONE 12.00 12.00 12.00 10.70 CK3BA036 35,000 NONE 12.00 12.00 12.00 10.75 9

UNIT SIZE-SERIES 036-C, D See notes on page 13. COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER CK3BA042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA036 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BN036 33,000 NONE 12.00 12.00 12.00 10.85 CK5A/CK5BN042 33,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BT036 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BT042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BW036 35,000 NONE 12.00 12.00 12.00 10.75 F(A,B)4AN(F,B,C)042 35,400 TDR 12.00 12.00 10.70 F(A,B)4AN(F,C)036 35,000 TDR 11.50 11.50 10.45 FC4BN(F,B)042 35,400 TDR & TXV 12.00 10.70 FC4BNF036 35,000 TDR & TXV 11.50 10.45 FG3AAA036 34,600 NONE 11.80 11.80 11.80 10.55 FK4CNB006 36,000 TDR & TXV 14.00 12.40 FK4CNF001 34,400 TDR & TXV 12.00 11.15 FK4CNF002 34,600 TDR & TXV 12.00 11.20 FK4CNF003 35,000 TDR & TXV 13.00 11.70 FK4CNF005 35,600 TDR & TXV 13.50 12.15 COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.25 CC5A/CD5AA042 35,000 TDR 12.50 12.50 11.25 CE3AA036 35,000 TDR 12.50 12.50 11.15 CE3AA042 35,000 TDR 13.00 13.00 11.35 CK3BA036 35,000 TDR 12.50 12.50 11.30 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.30 CK5A/CK5BN036 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.30 COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.45 CC5A/CD5AA042 35,000 TDR 13.00 13.00 11.60 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.45 CC5A/CD5AW042 35,000 TDR 13.00 13.00 11.55 CE3AA036 35,000 TDR 12.50 12.50 11.40 CE3AA042 35,000 TDR 13.00 13.00 11.60 CK3BA036 35,000 TDR 12.50 12.50 11.45 CK3BA042 35,000 TDR 13.00 13.00 11.55 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.55 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.55 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.45 COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW036 35,000 TDR 12.80 12.80 11.65 CC5A/CD5AW042 35,000 TDR 13.00 13.00 11.70 CE3AA036 35,000 TDR 12.50 12.50 11.60 CE3AA042 35,000 TDR 13.00 13.00 11.75 CK3BA042 35,000 TDR 13.00 13.00 11.80 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.80 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.80 CK5A/CK5BW036 35,000 TDR 12.80 12.80 11.75 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE CC5A/CD5AW036 35,000 TDR 12.80 12.80 11.50 CC5A/CD5AW042 35,000 TDR 13.00 13.00 11.60 CE3AA036 35,000 TDR 12.50 12.50 11.45 CE3AA042 35,000 TDR 13.00 12.50 11.65 CK3BA042 35,000 TDR 13.00 13.00 11.70 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.70 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.70 CK5A/CK5BW036 35,000 TDR 12.80 12.80 11.65 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.00 CC5A/CD5AA042 35,000 TDR 12.50 12.50 11.10 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.00 CK3BA036 35,000 TDR 12.50 12.50 11.00 CK3BA042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.00 CK5A/CK5BN042 34,000 TDR 12.50 12.50 11.15 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.00 10

UNIT SIZE-SERIES 036-C, D 042-C, D See notes on page 13. COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.80 12.80 11.20 CC5A/CD5AA042 35,000 TDR 12.80 12.80 11.35 CC5A/CD5AW036 35,000 TDR 12.80 12.80 11.20 CC5A/CD5AW042 35,000 TDR 12.80 12.80 11.25 CK5A/CK5BA042 35,000 TDR 12.80 12.80 11.25 CK5A/CK5BT042 35,000 TDR 12.80 12.80 11.25 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.10 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA036 35,000 TDR 12.50 12.50 11.00 CK3BA042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BA042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BT042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.00 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.80 12.80 11.25 CC5A/CD5AA042 35,000 TDR 13.00 13.00 11.40 CC5A/CD5AW036 35,000 TDR 12.80 12.80 11.25 CC5A/CD5AW042 35,000 TDR 13.00 13.00 11.35 CK3BA036 35,000 TDR 12.80 12.80 11.30 CK3BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BW036 35,000 TDR 12.80 12.80 11.30 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BW036 35,000 TDR 12.80 12.80 11.35 CC5A/CD5AA042* 40,000 NONE 12.00 12.00 12.00 10.45 CC5A/CD5AC048 40,000 NONE 12.00 12.00 12.00 10.35 CC5A/CD5AW042 40,000 NONE 12.00 12.00 12.00 10.35 CC5A/CD5AW048 40,500 NONE 12.00 12.00 12.00 10.45 CD5AA048 40,500 NONE 12.00 12.00 12.00 10.45 CE3AA042 40,000 NONE 12.00 12.00 12.00 10.50 CE3AA048 40,500 NONE 12.00 12.00 12.00 10.55 CF5AA048 40,500 NONE 12.00 12.00 12.00 10.45 CK3BA042 40,000 NONE 12.00 12.00 12.00 10.45 CK3BA048 40,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BA042 40,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BA048 40,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BN042 39,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BN048 39,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BT042 40,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BT048 40,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BW048 40,500 NONE 12.00 12.00 12.00 10.50 F(A,B)4AN(F,B,C)042 40,000 TDR 11.50 11.50 10.30 F(A,B)4AN(F,B,C)048 40,500 TDR 12.00 12.00 10.50 FC4BN(F,B)042 40,000 TDR & TXV 11.50 10.30 FC4BN(F,B)048 40,500 TDR & TXV 12.00 10.50 FC4BNB054 42,000 TDR & TXV 12.50 11.15 FG3AAA048 40,500 NONE 12.00 12.00 12.00 10.40 FK4CNB006 42,000 TDR & TXV 14.00 12.00 FK4CNF003 41,000 TDR & TXV 12.50 11.15 FK4CNF005 41,500 TDR & TXV 13.00 11.65 COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 10.95 CC5A/CD5AW042 40,000 TDR 12.50 12.50 10.85 CC5A/CD5AW048 40,500 TDR 13.00 13.00 11.10 CD5AA048 40,500 TDR 13.00 13.00 11.10 CE3AA042 40,000 TDR 12.80 12.80 11.00 CE3AA048 40,500 TDR 12.80 12.80 11.05 CK3BA042 40,000 TDR 12.50 12.50 10.95 CK3BA048 40,500 TDR 12.50 12.50 11.10 CK5A/CK5BA042 40,000 TDR 12.50 12.50 10.95 CK5A/CK5BA048 40,500 TDR 12.50 12.50 11.10 CK5A/CK5BT042 40,000 TDR 12.50 12.50 10.95 CK5A/CK5BT048 40,500 TDR 12.50 12.50 11.10 COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW042 40,000 TDR 12.50 12.50 11.10 CC5A/CD5AW048 40,500 TDR 13.00 13.00 11.30 CD5AA048 40,500 TDR 13.00 13.00 11.30 CE3AA042 40,000 TDR 13.00 13.00 11.25 CE3AA048 40,500 TDR 13.00 13.00 11.30 CK3BA042 40,000 TDR 12.50 12.50 11.20 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.20 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.20 CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.35 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE CC5A/CD5AW042 40,000 TDR 12.50 12.50 10.95 CC5A/CD5AW048 40,500 TDR 13.00 13.00 11.10 CD5AA048 40,500 TDR 13.00 13.00 11.10 11

UNIT SIZE-SERIES 042-C, D 048-E, F See notes on page 13. COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER CE3AA042 40,000 TDR 12.80 12.80 11.10 CE3AA048 40,500 TDR 13.00 13.00 11.15 CK3BA042 40,000 TDR 12.50 12.50 11.20 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.20 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.20 CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.30 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 10.95 CC5A/CD5AW042 40,000 TDR 12.50 12.50 10.85 CC5A/CD5AW048 40,000 TDR 12.50 12.50 11.05 CD5AA048 40,000 TDR 13.00 13.00 11.05 CK3BA048 40,000 TDR 12.50 12.15 11.00 CK5A/CK5BA048 40,000 TDR 12.50 12.50 11.00 CK5A/CK5BT048 40,000 TDR 12.50 12.50 11.00 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA048 40,500 TDR 12.30 12.30 10.85 CK5A/CK5BA048 40,500 TDR 12.30 12.30 10.85 CK5A/CK5BT048 40,500 TDR 12.30 12.30 10.85 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.00 CC5A/CD5AW042 40,000 TDR 12.50 12.50 10.90 CC5A/CD5AW048 40,000 TDR 13.00 13.00 11.10 CD5AA048 40,000 TDR 13.00 13.00 11.10 CK3BA048 40,500 TDR 13.00 13.00 11.20 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.20 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.20 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.20 CD5AA048* 47,000 NONE 12.00 12.00 12.00 10.60 CC5A/CD5AA060 47,500 NONE 12.10 12.10 12.10 10.65 CC5A/CD5AC048 46,000 NONE 11.80 11.80 11.80 10.50 CC5A/CD5AW048 47,000 NONE 12.00 12.00 12.00 10.60 CC5A/CD5AW060 47,500 NONE 12.20 12.20 12.20 10.90 CE3AA048 47,000 NONE 12.00 12.00 12.00 10.75 CE3AA060 47,500 NONE 12.10 12.10 12.10 11.00 CF5AA048 47,000 NONE 12.00 12.00 12.00 10.70 CK3BA048 47,000 NONE 12.00 12.00 12.00 10.65 CK3BA060 47,500 NONE 12.10 12.10 12.10 10.90 CK5A/CK5BA048 47,000 NONE 12.00 12.00 12.00 10.65 CK5A/CK5BA060 47,500 NONE 12.10 12.10 12.10 10.90 CK5A/CK5BN048 46,000 NONE 12.00 12.00 12.00 10.65 CK5A/CK5BN060 47,500 NONE 12.10 12.10 12.10 11.10 CK5A/CK5BT048 47,000 NONE 12.00 12.00 12.00 10.65 CK5A/CK5BT060 47,500 NONE 12.10 12.10 12.10 10.90 CK5A/CK5BW048 47,000 NONE 12.00 12.00 12.00 10.65 CK5A/CK5BX060 47,500 NONE 12.20 12.20 12.20 11.10 F(A,B)4AN(F,B,C)048 47,000 TDR 12.00 12.00 10.60 F(A,B)4AN(F,B,C)060 47,500 TDR 12.10 12.10 10.70 FB4ANB070 47,500 TDR 12.20 12.20 11.10 FC4BN(F,B)048 47,000 TDR & TXV 12.00 10.60 FC4BN(F,B)060 47,500 TDR & TXV 12.10 10.70 FC4BNB054 48,000 TDR & TXV 12.50 11.15 FG3AAA048 47,000 NONE 12.00 12.00 12.00 10.60 FG3AAA060 48,000 NONE 12.20 12.20 12.20 10.85 FK4CNB006 48,000 TDR & TXV 14.00 11.95 FK4CNF005 47,000 TDR & TXV 13.50 11.60 COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE CC5A/CD5AC048 46,500 TDR 12.00 12.00 10.60 CD5AA048 46,500 TDR 12.20 12.20 10.80 CJ5A/CK5A/CK5BT048 46,500 TDR 12.20 12.20 10.85 CK5A/CK5BA048 46,500 TDR 12.20 12.20 10.85 COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.50 12.50 11.35 CC5A/CD5AW048 46,500 TDR 12.50 12.50 11.20 CC5A/CD5AW060 47,500 TDR 13.00 13.00 11.70 CK5A/CK5BA060 47,000 TDR 12.50 12.50 11.65 CK5A/CK5BT060 47,000 TDR 12.50 12.50 11.65 CK5A/CK5BW048 46,500 TDR 12.50 12.50 11.30 CK5A/CK5BX060 47,500 TDR 13.00 13.00 11.95 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.50 12.50 11.25 CC5A/CD5AW048 46,500 TDR 12.50 12.50 11.10 CC5A/CD5AW060 47,500 TDR 13.00 13.00 11.60 CK5A/CK5BA060 47,000 TDR 12.50 12.50 11.55 CK5A/CK5BT060 47,000 TDR 12.50 12.50 11.55 CK5A/CK5BW048 46,500 TDR 12.50 12.50 11.20 CK5A/CK5BX060 47,500 TDR 13.00 13.00 11.80 12

UNIT SIZE-SERIES 048-E, F 060-E, F COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER COILS + 355MAV042080 VARIABLE-SPEED FURNACE CD5AA048 46,500 TDR 12.20 12.20 10.85 CK5A/CK5BA048 46,500 TDR 12.20 12.20 10.80 CK5A/CK5BT048 46,500 TDR 12.20 12.20 10.80 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.20 12.20 10.80 CC5A/CD5AW060 47,500 TDR 12.50 12.50 11.00 CD5AA048 46,500 TDR 12.00 12.00 10.60 CK5A/CK5BA048 46,500 TDR 12.00 12.00 10.70 CK5A/CK5BA060 47,000 TDR 12.20 12.20 10.95 CK5A/CK5BT048 46,500 TDR 12.00 12.00 10.70 CK5A/CK5BT060 47,000 TDR 12.20 12.20 10.95 CK5A/CK5BX060 47,500 TDR 12.50 12.50 11.25 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.50 12.50 11.00 CC5A/CD5AC048 46,500 TDR 12.00 12.00 10.65 CC5A/CD5AW060 47,500 TDR 13.00 13.00 11.35 CD5AA048 46,500 TDR 12.50 12.50 10.95 CK5A/CK5BA048 46,500 TDR 12.50 12.50 11.00 CK5A/CK5BA060 47,000 TDR 12.50 12.50 11.30 CK5A/CK5BT048 46,500 TDR 12.50 12.50 11.00 CK5A/CK5BT060 47,000 TDR 12.50 12.50 11.30 CK5AS/CK5BX060 47,500 TDR 13.00 13.00 11.55 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.50 12.50 11.00 CC5A/CD5AW048 46,500 TDR 12.50 12.50 10.95 CC5A/CD5AW060 47,500 TDR 13.00 13.00 11.35 CK5A/CK5BA060 47,000 TDR 12.50 12.50 11.30 CK5A/CK5BT060 47,000 TDR 12.50 12.50 11.30 CK5A/CK5BW048 46,500 TDR 12.50 12.50 11.05 CK5A/CK5BX060 47,500 TDR 13.00 13.00 11.60 CC5A/CD5AW060* 58,000 NONE 12.00 12.00 12.00 10.70 CC5A/CD5AA060 56,000 NONE 11.50 11.50 11.50 10.50 CE3AA060 58,000 NONE 12.00 12.00 12.00 10.80 CK3BA060 56,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BA060 56,000 NONE 11.50 11.50 11.50 10.60 CK5A/CK5BN060 56,000 NONE 11.50 11.50 11.50 10.95 CK5A/CK5BT060 56,000 NONE 11.50 11.50 11.50 10.45 CK5A/CK5BX060 58,000 NONE 12.00 12.00 12.00 10.90 F(A,B)4AN(F,B,C)060 58,000 TDR 11.50 11.50 10.40 FB4ANB070 58,500 TDR 12.00 12.00 10.85 FC4BN(F,B)060 58,000 TDR & TXV 11.50 10.40 FC4BNB070 58,500 TDR & TXV 12.00 10.85 FK4CNB006 59,000 TDR & TXV 13.00 11.40 COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12.20 12.20 10.90 CC5A/CD5AW060 58,000 TDR 12.50 12.50 11.30 CK3BA060 56,000 TDR 12.20 12.20 10.90 CK5A/CK5BA060 56,000 TDR 12.20 12.20 10.90 CK5A/CK5BT060 56,000 TDR 12.20 12.20 10.90 CK5A/CK5BX060 58,000 TDR 12.50 12.50 11.30 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12.20 12.20 10.75 CC5A/CD5AW060 58,000 TDR 12.50 12.50 11.30 CK3BA060 56,000 TDR 12.20 12.20 10.75 CK5A/CK5BA060 56,000 TDR 12.20 12.20 10.75 CK5A/CK5BT060 56,000 TDR 12.20 12.20 10.75 CK5A/CK5BX060 58,000 TDR 12.50 12.50 11.30 * Tested Combination In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR. Must be installed with hard shutoff TXV to achieve rating. EER Energy Efficiency Ratio LSV Liquid Solenoid Valve SEER Seasonal Energy Efficiency Ratio NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 13

EVAPORATOR AIR CFM 700 800 900 EWB See notes on page 20. DETAILED COOLING CAPACITIES* CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens 25.9 23.6 21.4 20.3 26.5 24.1 21.9 21.1 26.9 24.5 22.3 21.8 563C024-B Outdoor Section With CC5A/CD5AA024 Section 12.7 15.9 19.0 20.3 13.2 16.9 20.3 21.1 13.8 17.8 21.4 21.8 1.92 1.93 1.93 1.92 1.96 1.96 1.96 1.97 2.00 2.00 2.00 2.00 25.0 22.7 20.6 19.7 25.5 23.2 21.1 20.5 25.8 23.5 21.4 21.1 12.3 15.5 18.6 19.7 12.9 16.5 19.9 20.5 13.4 17.4 20.9 21.1 2.13 2.13 2.13 2.12 2.17 2.17 2.17 2.17 2.20 2.20 2.20 2.20 24.1 21.9 19.8 19.1 24.5 22.3 20.2 19.8 24.8 22.6 20.6 20.5 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 024 1.00 1.00 CK3BA 024 1.01 0.92 030 1.02 1.00 030 1.01 0.91 CC5A/CD5AW 024 1.00 1.00 CK5A/CK5BA 024 1.01 0.92 030 1.02 1.00 030 1.01 0.91 CE3AA 024 1.02 1.00 CK5A/CK5BW 030 1.01 0.91 030 1.03 1.00 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CF5AA 024 1.02 1.00 CC5A/CD5AA 024 1.01 0.94 CK3BA 024 1.00 1.00 030 1.02 0.93 030 1.02 1.00 CC5A/CD5AW 024 1.01 0.94 CK5A/CK5BA 024 1.00 1.00 030 1.02 0.93 030 1.02 1.00 CK3BA 024 1.01 0.94 CK5A/CK5BW 024 1.00 1.00 030 1.02 0.94 030 1.02 1.00 CK5A/CK5BW 030 1.02 0.94 F(A,B)4AN(F,C) 024 1.01 1.00 COILS + 355MAV042060 VARIABLE-SPEED FURNACE 030 1.03 0.99 CC5A/CD5AA 024 1.01 0.94 FC4BNF 024 1.01 1.00 030 1.02 0.93 030 1.03 0.99 CC5A/CD5AW 024 1.01 0.94 033 1.04 1.00 030 1.02 0.93 FF1(B,C,D)NA 024 1.01 1.01 CK3BA 024 1.01 0.94 030 1.02 1.01 030 1.02 0.94 FG3AAA 024 1.00 1.00 CK5A/CK5BW 024 1.01 0.94 FK4CNF 001 1.03 0.92 030 1.02 0.94 002 1.03 0.92 COILS + 355MAV042080 VARIABLE-SPEED FURNACE 003 1.03 0.90 CC5A/CD5AA 024 1.01 0.94 COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE 030 1.02 0.93 CC5A/CD5AA 024 1.01 0.92 CC5A/CD5AW 024 1.01 0.94 030 1.02 0.91 030 1.02 0.93 CC5A/CD5AW 024 1.01 0.92 CK3BA 024 1.01 0.93 030 1.02 0.91 030 1.02 0.92 CE3AA 024 1.02 0.93 CK5A/CK5BW 024 1.01 0.93 030 1.03 0.92 030 1.02 0.92 12.0 15.2 18.2 19.1 12.5 16.1 19.4 19.8 13.0 17.0 20.4 20.5 2.37 2.36 2.36 2.35 2.40 2.40 2.40 2.41 2.44 2.44 2.44 2.43 23.1 21.0 19.0 18.5 23.5 21.4 19.4 19.2 23.8 21.7 19.8 19.8 11.6 14.8 17.8 18.5 12.2 15.8 19.0 19.2 12.7 16.6 19.8 19.8 2.63 2.63 2. 2.63 2. 2. 2.66 2.66 2.71 2.71 2.70 2.70 22.2 20.1 18.2 17.8 22.5 20.5 18.6 18.5 22.8 20.7 19.1 19.1 11.3 14.5 17.4 17.8 11.8 15.4 18.5 18.5 12.3 16.3 19.1 19.1 Kw** 2.94 2.93 2.92 2.94 2.98 2.97 2.96 2.98 3.02 3.01 3.00 3.03 14

EVAPORATOR AIR CFM 875 1000 1125 EWB See notes on page 20. DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens 32.3 29.5 26.9 25.5 32.9 30.1 27.4 26.5 33.4 30.6 27.9 27.3 563C030-B Outdoor Section With CC5A/CD5AA030 Section 15.8 19.8 23.8 25.5 16.4 21.0 25.3 26.5 17.1 22.1 26.7 27.3 2.41 2.39 2.37 2.36 2.46 2.44 2.42 2.42 2.51 2.49 2.47 2.47 31.2 28.5 25.9 24.7 31.7 29.0 26.4 25.6 32.2 29.4 26.8 26.4 15.4 19.4 23.3 24.7 16.0 20.5 24.8 25.6 16.6 21.7 26.1 26.4 2.65 2. 2.61 2.60 2.70 2. 2.66 2.65 2.75 2.73 2.71 2.70 30.0 27.4 24.9 23.9 30.5 27.9 25.3 24.8 30.9 28.2 25.8 25.6 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 030 1.00 1.00 CK3BA 030 1.00 0.93 036 1.02 1.00 036 1.02 0.91 CC5A/CD5AW 030 1.00 1.00 CK5A/CK5BW 030 1.00 0.93 CD5AW 036 1.02 1.00 036 1.02 0.91 CE3AA 030 1.00 1.00 COILS + 355MAV042040 VARIABLE-SPEED FURNACE 036 1.02 1.00 CC5A/CD5AA 030 1.00 0.96 CF5AA 036 1.02 1.00 036 1.02 0.95 CK3BA 030 1.00 1.00 CC5A/CD5AW 030 1.00 0.96 036 1.02 1.00 CD5AW 036 1.02 0.95 CK5A/CK5BA 030 1.00 1.00 CK3BA 030 1.00 0.97 036 1.02 1.00 036 1.02 0.95 CK5A/CK5BN 036 0.95 1.00 CK5A/CK5BW 030 1.00 0.97 CK5A/CK5BW 030 1.00 1.00 036 1.02 0.95 036 1.02 1.00 COILS + 355MAV042060 VARIABLE-SPEED FURNACE F(A,B)4AN(F,C) 030 1.01 0.99 CC5A/CD5AA 030 1.00 0.96 036 1.02 1.01 036 1.02 0.95 FC4BNF 030 1.01 0.99 CC5A/CD5AW 030 1.00 0.96 033 1.03 0.99 CD5AW 036 1.02 0.95 036 1.02 1.01 CK3BA 030 1.00 0.96 FF1(B,C,D)NA 030 1.00 1.00 036 1.02 0.95 FG3AAA 036 1.02 1.00 CK5A/CK5BA 036 1.02 0.95 FK4CNF 001 1.01 0.93 CK5A/CK5BW 030 1.00 0.96 002 1.01 0.93 COILS + 355MAV042080 VARIABLE-SPEED FURNACE 003 1.03 0.91 CC5A/CD5AA 030 1.00 0.96 005 1.03 0.90 036 1.02 0.95 COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE CC5A/CD5AW 030 1.00 0.96 CC5A/CD5AA 030 1.00 0.94 CD5AW 036 1.02 0.95 036 1.02 0.93 CK3BA 030 1.00 0.96 CC5A/CD5AW 030 1.00 0.94 036 1.02 0.94 CD5AW 036 1.02 0.93 CK5A/CK5BW 030 1.00 0.96 CE3AA 030 1.00 0.94 036 1.02 0.94 036 1.02 0.94 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA 030 1.00 0.94 CK3BA 030 1.00 0.97 036 1.02 0.92 036 1.02 0.95 CK5A/CK5BA 030 1.00 0.94 CK5A/CK5BW 030 1.00 0.97 036 1.02 0.92 036 1.02 0.95 CK5A/CK5BN 036 0.95 0.93 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CK5A/CK5BW 030 1.00 0.94 CK3BA 030 1.00 0.94 COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE 036 1.02 0.93 CC5A/CD5AA 030 1.00 0.94 CK5A/CK5BW 030 1.00 0.94 036 1.02 0.93 036 1.02 0.93 CC5A/CD5AW 030 1.00 0.94 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CD5AW 036 1.02 0.93 CK3BA 030 1.00 0.95 CE3AA 030 1.00 0.94 036 1.02 0.93 036 1.02 0.94 CK5A/CK5BW 036 1.02 0.93 14.9 18.9 22.8 23.9 15.6 20.1 24.2 24.8 16.2 21.2 25.4 25.6 2.91 2.88 2.87 2.86 2.96 2.94 2.91 2.91 3.01 2.99 2.96 2.96 28.8 26.2 23.8 23.1 29.2 26.7 24.3 24.0 29.6 27.0 24.7 24.7 14.5 18.5 22.3 23.1 15.1 19.6 23.6 24.0 15.7 20.7 24.7 24.7 3.21 3.18 3.15 3.16 3.26 3.23 3.18 3.21 3.31 3.28 3.26 3.26 27.5 25.1 22.8 22.3 28.0 25.5 23.3 23.1 28.3 25.7 23.8 23.8 14.0 18.0 21.7 22.3 14.6 19.1 23.0 23.1 15.2 20.2 23.8 23.8 Kw** 3.54 3.52 3.47 3.50 3.59 3. 3.55 3.55 3.65 3.58 3.58 3.60 15

EVAPORATOR AIR CFM 1050 1200 1350 EWB See notes on page 20. DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens 39.0 35.7 32.7 31.3 39.7 36.4 33.3 32.5 40.2 36.9 33.9 33.5 563C036-C, D Outdoor Section With CC5A/CD5AA036 Section 19.3 24.5 29.5 31.3 20.2 26.0 31.5 32.5 21.0 27.5 33.2 33.5 2.89 2.86 2.83 2.82 2.95 2.92 2.89 2.89 3.01 2.98 2.96 2.95 37.6 34.4 31.4 30.4 38.2 35.0 32.1 31.5 38.6 35.4 32.6 32.5 18.8 24.0 28.9 30.4 19.7 25.5 30.8 31.5 20.5 26.9 32.3 32.5 3.18 3.15 3.12 3.11 3.24 3.21 3.19 3.18 3.30 3.26 3.23 3.24 35.9 32.9 30.1 29.3 36.5 33.5 30.7 30.4 36.9 33.9 31.3 31.3 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 036 1.00 1.00 CK5A/CK5BA 042 1.00 0.93 042 1.00 1.00 CK5A/CK5BT 042 1.00 0.93 CC5A/CD5AW 036 1.00 1.00 CK5A/CK5BW 036 1.00 0.93 042 1.00 1.00 COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE CE3AA 036 1.00 1.00 CC5A/CD5AW 036 1.00 0.92 042 1.01 1.00 042 1.00 0.91 CF5AA 036 1.00 1.00 CE3AA 036 1.00 0.91 CK3BA 036 1.00 1.00 042 1.00 0.92 042 1.00 1.00 CK3BA 042 1.00 0.91 CK5A/CK5BA 036 1.00 1.00 CK5A/CK5BA 042 1.00 0.91 042 1.00 1.00 CK5A/CK5BT 042 1.00 0.91 CK5A/CK5BN 036 0.94 0.97 CK5A/CK5BW 036 1.00 0.92 042 0.94 1.00 COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE CK5A/CK5BT 036 1.00 1.00 CC5A/CD5AW 036 1.00 0.93 042 1.00 1.00 042 1.00 0.91 CK5A/CK5BW 036 1.00 1.00 CE3AA 036 1.00 0.92 F(A,B)4AN(F,B,C) 042 1.01 1.01 042 1.00 0.92 F(A,B)4AN(F,C) 036 1.00 1.02 CK3BA 042 1.00 0.92 FC4BN(F,B) 042 1.01 1.01 CK5A/CK5BA 042 1.00 0.92 FC4BNF 036 1.00 1.02 CK5A/CK5BT 042 1.00 0.92 FG3AAA 036 0.99 0.99 CK5A/CK5BW 036 1.00 0.92 FK4CNB 006 1.03 0.91 COILS + 355MAV042060 VARIABLE-SPEED FURNACE FK4CNF 001 0.98 0.95 CC5A/CD5AA 036 1.00 0.98 002 0.99 0.95 042 1.00 0.97 003 1.00 0.92 CC5A/CD5AW 036 1.00 0.98 005 1.02 0.92 CK3BA 036 1.00 0.98 COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE 042 1.00 0.97 CC5A/CD5AA 036 1.00 0.94 CK5A/CK5BA 036 1.00 0.98 042 1.00 0.94 CK5A/CK5BN 042 0.97 0.97 CE3AA 036 1.00 0.94 CK5A/CK5BT 036 1.00 0.98 042 1.00 0.94 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CK3BA 036 1.00 0.94 CC5A/CD5AA 036 1.00 0.97 CK5A/CK5BA 036 1.00 0.94 042 1.00 0.96 CK5A/CK5BN 036 1.00 0.95 CC5A/CD5AW 036 1.00 0.97 CK5A/CK5BT 036 1.00 0.94 042 1.00 0.96 COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE CK5A/CK5BA 042 1.00 0.96 CC5A/CD5AA 036 1.00 0.93 CK5A/CK5BT 042 1.00 0.96 042 1.00 0.92 CK5A/CK5BW 036 1.00 0.98 CC5A/CD5AW 036 1.00 0.93 COILS + 355MAV060080 VARIABLE-SPEED FURNACE 042 1.00 0.92 CK3BA 036 1.00 0.98 CE3AA 036 1.00 0.92 CK3BA 042 1.00 0.97 042 1.00 0.93 CK5A/CK5BA 042 1.00 0.97 CK3BA 036 1.00 0.93 CK5A/CK5BT 042 1.00 0.97 042 1.00 0.93 CK5A/CK5BW 036 1.00 0.98 18.2 23.4 28.2 29.3 19.0 24.9 30.0 30.4 19.9 26.3 31.3 31.3 3.48 3.45 3.42 3.41 3.55 3.52 3.49 3.48 3.61 3.58 3.55 3.55 34.3 31.4 28.7 28.2 34.8 31.9 29.3 29.2 35.2 32.2 30.0 30.0 17.6 22.7 27.5 28.2 18.5 24.2 29.1 29.2 19.3 25.7 30.0 30.0 3.83 3.79 3.75 3.74 3.90 3.85 3.82 3.81 3.96 3.92 3.89 3.88 32.6 29.8 27.3 27.0 33.1 30.2 27.9 27.9 33.4 30.5 28.7 28.7 17.0 22.1 26.7 27.0 17.9 23.6 27.9 27.9 18.7 25.0 28.7 28.7 Kw** 4.21 4.15 4.10 4.11 4.28 4.21 4.17 4.18 4.34 4.27 4.25 4.26 16