EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Similar documents
Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

Providing Comfort Through Efficient Energy Solutions PRICE BOOK (USD) - LIST EFFECTIVE JUNE 1,

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Tankless On Demand Electric Water Heater

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Industrial Series. Electric Hot Water Boiler EB-NB Series Installation & Operating Manual

GB Condensing Gas Boiler

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Control and power circuit fusing to meet N.E.C.

Industrial Series. Electric Hot Water Boiler EB-NB Series Installation & Operating Manual

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

SECTION DOMESTIC WATER HEATERS

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

GB Condensing Gas Boiler

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

GB Condensing Gas Boiler

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

Date: Project #: Engineer: Prepared By: Bid Date:

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

ASME Packaged Electric Water Heater

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

RHP120 RHP300 Steam Boiler Series

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Indirect Fired Water Heater

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Boiler & Water Heater

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Revitalize Building Mechanical Systems (4619)

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

ELECTRO-BOILER Commercial Series

MODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Easy Installation & Service

Utica Boilers MAC Submittal

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

High Capacity Instantaneous Steam Fired Water Heater

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

THERMOLEC. Installation Instructions for Electric Boilers (USA) June 2018 Version 12 TMB FFB (STANDARD) FFB (LARGE) (TANDEM)

CLE SERIES Fluid heating for emergency eyewash stations

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

SECTION ROTARY-SCREW WATER CHILLERS

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Description. Applications

RQE Series Temperature Controllers

INSTALLATION INSTRUCTIONS

Tepid Water Delivery System

DIVISION FINNED WATER-TUBE BOILERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Water Heaters. Solar Applications

INSTALLATION AND SERVICE MANUAL

Light Duty Commercial Electric Water Heater

TABLE OF CONTENTS page 2

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

ASME Packaged Indirect Fired Water Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

AFUE 95% Heating Input 50,000 to 200,000 Btuh

MONITRON II MODEL EH-M2 ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS. Four stage electronic control with energy saving and other features.

Circulation Heaters Selection Guidelines

Proudly assembled in U.S.A

Shipboard Electric Water Heater

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS

Proudly assembled in U.S.A

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Raypak Residential Products

Centro-Matic Automated Lubrication Systems System Controls

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Circulation Heaters Selection Guidelines

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Circulating Water Temperature Controller

CONTENTS AUTOMATIC TRANSFER SWITCHES

Packaged Semi-Instantaneous Steam Fired Water Heater

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

C1N & C2N SERIES Fluid heating for light industrial applications

FX5 Series Explosion-Proof Electric Air Heaters

Transcription:

Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional dimension and mechanical details for installers requiring this information prior to receiving the unit with its appropriate installation manual. They can be downloaded from www.electromn.com. The following are currently available: EMB-S-* Mini-Boiler BL306 EB-M*-** Midsize Electro-Boiler BL509 EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506 EB-CX-** TS Commercial Electro-Boiler BL508 EB-NB-**-*** Industrial Electro-Boiler BL803 03/20/2018 1 XC018

Specification Data Sheet - Mini-Boiler TM STANDARD EQUIPMENT Staging - EMB-S-* Supply water sensing Regulates to front panel selected temperature Temperature range 90 F to 160 F Staging indicator lights DC Power Relays Hi-limits: 1 st - automatic reset at 190 F 2 nd - manual reset at 205 F Circulator switching relay - 10-amp maximum Thermostat or end switch connection (R and W) Utility load control provisions 1 gl. Steel vessel ASME H Stamp (20-year warranty*) Supply temperature/pressure gauge Safety relief valve (30 PSI) Made in the USA Modulating - EMB-H-* Same as EMB-S-* PLUS Modulates at a tighter temperature control Temperature range 90 F to 180 F WATER FLOW REQUIREMENTS (MINIMUM 1 GPM WATER FLOW THROUGH BOILER) Water Temperature Rise Model Flow - 10 F/6 C Head Loss Flow - 20 F/11 C Head Loss Flow - 30 F/16 C Head Loss gpm lpm ft m gpm lpm ft m gpm lpm ft m EMB-S-1.75 2.83.01.003.37 1.39.003.001.25 1.89.003.001 EMB-S-2 1.7 6.43.01.006.85 3.21.02.006.56 2.11.004.001 EMB-S-4 3.41 12.88.08.024 1.70 6.42.04.012 1.13 4.27.02.006 EMB-*-5 3.07 11.60.06.018 1.53 5.78.02.006 1.02 3.85.02.006 EMB-*-7 4.78 18.06.12.036 2.39 9.03.06.01 1.59 6.01.02.006 EMB-*-9 6.14 23.20.23.07 3.07 11.60.10.03 2.04 7.71.06.018 * = S or H Result below minimum required flow of boiler, make sure system design provides minimum flow requirements of boiler. Note: Head Loss based on 110 F return temperature. ELECTRIC SUPPLY CLEARANCES Model Volts Watts Amps kw Phase Btu/h CB EMB-S-1 120 1,100 9.17 1.1 1-60 3,754 N/A EMB-S-2 120 2,500 20.83 2.5 1-60 8,532 N/A EMB-S-4 120 5,000 41.67 5 1-60 17,065 N/A EMB-*-5 240 4,500 18.75 4.5 1-60 15,358 30A EMB-*-7 240 7,000 29.17 7 1-60 23,891 45A EMB-*-9 240 9,000 37.5 9 1-60 30,717 60A MINIMUM CLEARANCE FROM SUGGESTED MINIMUM COMBUSTIBLE SURFACES SERVICE CLEARANCE BACK 0 INCH 0 MM 0 INCH 0 MM LEFT 1 INCH 25 MM 6 INCHES 152 MM RIGHT 1 INCH 25 MM 6 INCHES 152 MM FRONT 1 INCH 25 MM 24 INCHES 610 MM TOP 1 INCH 25 MM 24 INCHES 610 MM BOTTOM REQUIRED CLEARANCE - 18 INCHES/450 MM * = S or H SHIPPING WEIGHT Model Weight (lbs) EMB-S-1 44 EMB-S-2 44 EMB-S-4 44 EMB-*-5 45 EMB-*-7 46 EMB-*-9 46 Specifi cations subject to change without notice, all rights reserved. 05/27/2010 BL306

MINI-BOILER, EMB-(H,S)-* Hydronic Boilers Submittal Data 3/4"-1/2" CONDUIT 59 2 3/8" OUT 53 2 1/8" 221 8 5/8" 217 8 5/8" MOUNT THIS END UP 3/4" NPT 3/8" THERMOSTAT WIRE OPENING 266 10 1/2" 178 7" 36 1 3/8" 106 4 1/8" 84 3 1/4" 163 6 3/8" 201 7 7/8" 584 23" 635 25" 705 27 3/4" 2X 3/4"-1/2" CONDUIT 35 1 3/8" 3/4" NPT 143 5 5/8" 243 9 1/2" 49 1 7/8" 457 MINIMUM CLEARANCE 18" FROM FLOOR DIMENSIONS ARE: [mm] IN IN ELECTRO INDUSTRIES, INC. MONTICELLO, MN 55362 BL306 Rev. B 12/29/2009 Sheet 1 of 1

Specification Data Sheet - TS Series Midsize Electro-Boiler TM STANDARD EQUIPMENT Staging - EB-MS-** Supply water sensing Regulates to front panel selected temperature Staging indicator lights DC Power Relays Hi-limits: 1 st - automatic reset at 190 F 2 nd - manual reset at 205 F Circulator switching relay - 10-amp maximum Thermostat or end switch connection (R and W) Utility load control provisions 2.2 gl. Steel vessel ASME H Stamp (20-year warranty) Supply temperature/pressure gauge Safety relief valve (30 PSI) Standby switch and boiler contact Made in the USA Modulating - EB-MX-** Same as EB-MS-** PLUS Modulates at a tighter temperature control Outdoor sensing with outdoor reset capability. The target supply temperature ramps up as it is colder outside. WATER FLOW REQUIREMENTS (MINIMUM 2 GPM WATER FLOW THROUGH BOILER) Water Temperature Rise Model Flow - 10 F/6 C Head Loss Flow - 20 F/11 C Head Loss Flow - 30 F/16 C Head Loss gpm lpm ft m gpm lpm ft m gpm lpm ft m EB-M*-10 6.82 25.82.01.003 3.41 12.91.004.001 2.27 8.59.001.001 EB-M*-15 10.23 38.73.03.009 5.11 19.34.01.003 3.41 12.91.004.001 EB-M*-20 13.65 51.66.07.02 6.82 25.01.02.006 4.55 17.22.01.003 * = S or X Note: Head Loss based on 110 F return temperature. ELECTRIC SUPPLY Model Volts Watts Amps kw Phase Btu/h CB EB-M*-10 240 10,000 41.66 10 1-60 34,130 60 EB-M*-15 240 15,000 62.50 15 1-60 51,195 60 + 30 EB-M*-20 240 20,000 83.33 20 1-60 68,260 60 + 60 * = S or X Canadian models include single feed bus option where applicable. CLEARANCES MINIMUM CLEARANCE FROM SUGGESTED MINIMUM COMBUSTIBLE SURFACES SERVICE CLEARANCE BACK 0 INCH 0 MM 0 INCH 0 MM LEFT 1 INCH 25 MM 12 INCHES 305 MM RIGHT 1 INCH 25 MM 6 INCHES 152 MM FRONT 1 INCH 25 MM 24 INCHES 610 MM TOP 1 INCH 25 MM 24 INCHES 610 MM BOTTOM REQUIRED CLEARANCE - 18 INCHES/457 MM SHIPPING WEIGHT Model Weight (lbs) EB-M*-10 76 EB-M*-15 77 EB-M*-20 78 Specifi cations subject to change without notice, all rights reserved. Monticello, Minnesota 800.922.4138 www.electromn.com 02/09/2016 BL509

Specification Data Sheet - TS Standard Electro-Boiler TM STANDARD EQUIPMENT Staging - EB-S-** Supply water sensing Regulates to front panel selected temperature Staging indicator lights DC Power Relays Hi-limits: 1 st - automatic reset at 190 F 2 nd - manual reset at 205 F Circulator switching relay - 10-amp maximum Thermostat or end switch connection (R and W) Utility load control provisions 6.5 gl. Steel vessel ASME H Stamp (20-year warranty*) Supply temperature/pressure gauge * 20-year warranty does not apply to 3-phase models. WATER FLOW REQUIREMENTS (MINIMUM 2 GPM WATER FLOW THROUGH BOILER) Water Temperature Rise Model Flow - 10 F/6 C Head Loss Flow - 20 F/11 C Head Loss Flow - 30 F/16 C Head Loss gpm lpm ft m gpm lpm ft m gpm lpm ft m EB-**-13 9.21 34.86.03.009 4.60 17.41.01.003 3.07 11.62.004.001 EB-**-18 12.28 46.49.06.018 6.14 23.24.02.006 4.09 15.48.01.003 EB-**-23 15.35 58.11.09.027 7.67 29.03.02.006 5.11 19.34.01.003 EB-**-27 18.43 69.77.13.039 9.21 34.86.03.009 6.14 23.24.02.006 EB-WX-13-2 9.21 34.86.03.009 4.60 17.41.01.003 3.07 11.62.004.001 EB-WX-27-2 18.43 69.77.13.039 9.21 34.86.03.009 6.14 23.24.02.006 ** = S or WX Note: Head Loss based on 110 F return temperature. ELECTRIC SUPPLY Model Volts Watts Amps kw Phase Btu/h CB EB-**-13 240 13,500 56 13.5 1-60 46,075 60 + 30 EB-**-18 240 18,000 75 18 1-60 61,434 60 + 60 EB-**-23 240 22,500 94 22.5 1-60 76,792 60 + 60 + 30 EB-**-27 240 27,000 113 27 1-60 92,151 60 + 60 + 60 EB-WX-13-2 208 13,500 37.5 13.5 3-60 46,075 50 EB-WX-27-2 208 27,000 75 27 3-60 92,151 100 ** = S or WX Canadian models include single feed bus option where applicable. SHIPPING WEIGHT Model Weight (lbs) EB-**-13 150 EB-**-18 152 EB-**-23 153 EB-**-27 155 EB-WX-13-2 150 EB-WX-27-2 155 Safety relief valve (30 PSI) Standby switch and boiler contact Made in the USA Modulating - EB-WX-** Same as EB-S-** PLUS Modulates at a tighter temperature control Outdoor sensing with outdoor reset capability. The target supply temperature ramps up as it is colder outside. CLEARANCES MINIMUM CLEARANCE FROM SUGGESTED MINIMUM COMBUSTIBLE SURFACES SERVICE CLEARANCE BACK 0 INCH 0 MM 0 INCH 0 MM LEFT 1 INCH 25 MM 12 INCHES 305 MM RIGHT 1 INCH 25 MM 6 INCHES 152 MM FRONT 1 INCH 25 MM 24 INCHES 610 MM TOP 1 INCH 25 MM 24 INCHES 610 MM BOTTOM REQUIRED CLEARANCE - 16 INCHES/406 MM Specifi cations subject to change without notice, all rights reserved. Monticello, Minnesota 800.922.4138 www.electromn.com 02/09/2016 BL506

Specification Data Sheet - TS Large Electro-Boiler TM WATER FLOW REQUIREMENTS (MINIMUM 4 GPM WATER FLOW THROUGH BOILER) Water Temperature Rise Model Flow - 20 F/6 C Head Loss Flow - 30 F/11 C Head Loss Flow - 40 F/16 C Head Loss gpm lpm ft m gpm lpm ft m gpm lpm ft m EB-CX-18-60 6.14 23.24.002.0006 4.09 15.48.001.0003 3.07 11.62.0008.0002 EB-CX-24-60 8.19 31.00.002.0006 5.46 20.66.001.0003 4.09 15.48.0008.0002 EB-CX-30-60 10.23 38.72.06.018 6.82 25.81.07.021 5.11 19.34.07.021 EB-CX-36-60 12.28 46.49.01.003 8.19 31.00.004.001 6.14 23.24.002.0006 EB-CX-45-60 15.35 58.10.02.006 10.23 38.72.01.003 7.67 29.03.01.003 EB-CX-54-60 18.43 69.77.02.006 12.28 46.49.01.003 9.21 34.86.01.003 EB-CX-18-48 6.14 23.24.002.0006 4.09 15.48.001.0003 3.07 11.62.0008.0002 EB-CX-36-48 12.28 46.49.01.003 8.19 31.00.004.001 6.14 23.24.002.0006 EB-CX-54-48 18.43 69.77.02.006 12.28 46.49.01.003 9.21 34.86.01.003 EB-CX-27-20 9.21 34.86.01.003 6.14 23.24.002.0006 4.60 17.41.001.0003 EB-CX-40-20 13.82 52.32.01.003 9.21 34.86.01.003 6.91 26.16.003.0009 EB-CX-27-24 9.21 34.86.01.003 6.14 23.24.002.0006 4.60 17.41.001.0003 EB-CX-40-24 13.82 52.32.01.003 9.21 34.86.01.003 6.91 26.16.003.0009 EB-CX-31 10.75 40.69.06.018 7.16 27.10.07.021 5.37 20.33.07.021 EB-CX-36 12.28 46.49.06.018 8.19 31.00.06.018 6.14 23.24.07.021 EB-CX-40 13.65 51.67.01.003 9.10 34.44.01.003 6.82 25.81.003.0009 EB-CX-44 15.01 56.82.02.006 10.01 37.89.01.003 7.50 28.39.01.003 Result below minimum required flow of boiler, make sure system design provides minimum flow requirements of boiler. Note: Head Loss based on 110 F return temperature. ELECTRIC SUPPLY Model Volts Watts Amps kw Phase Btu/h CB EB-CX-18-60 600 18,000 17 18 3-60 61,000 30 EB-CX-24-60 600 24,000 23 24 3-60 81,600 30 EB-CX-30-60 600 30,000 29 30 3-60 102,000 45 EB-CX-36-60 600 36,000 35 36 3-60 123,000 45 EB-CX-45-60 600 45,000 44 45 3-60 153,000 60 EB-CX-54-60 600 54,000 52 54 3-60 184,000 70 EB-CX-18-48 480 18,000 22 18 3-60 61,434 30 EB-CX-36-48 480 36,000 44 36 3-60 122,868 60 EB-CX-54-48 480 54,000 65 54 3-60 184,302 80 EB-CX-27-20 208 27,000 75 27 3-60 92,151 100 EB-CX-40-20 208 40,500 113 40.5 3-60 138,226 150 EB-CX-27-24 240 27,000 65 27 3-60 92,151 80 EB-CX-40-24 240 40,500 98 40.5 3-60 138,226 125 EB-CX-31 240 31,500 131 31.5 1-60 107,509 100 + 80 EB-CX-36 240 36,000 150 36 1-60 122,868 100 + 100 EB-CX-40 240 40,000 167 40 1-60 136,000 125 + 125 EB-CX-44 240 44,000 183 44 1-60 150,000 125 + 125 Canadian models include single feed bus option where applicable. SHIPPING WEIGHT Model Weight (lbs) CLEARANCES Model Weight (lbs) EB-CX-18-60 225 EB-CX-27-20 227 EB-CX-24-60 227 EB-CX-40-20 233 EB-CX-30-60 230 EB-CX-27-24 227 EB-CX-36-60 232 EB-CX-40-24 233 EB-CX-45-60 233 EB-CX-31 230 EB-CX-54-60 237 EB-CX-36 232 EB-CX-18-48 225 EB-CX-40 233 EB-CX-36-48 232 EB-CX-44 233 EB-CX-54-48 237 MINIMUM CLEARANCE FROM SUGGESTED MINIMUM COMBUSTIBLE SURFACES SERVICE CLEARANCE BACK 0 INCH 0 MM 0 INCH 0 MM LEFT 1 INCH 25 MM 16 INCHES 406 MM RIGHT 1 INCH 25 MM 6 INCHES 152 MM FRONT 1 INCH 25 MM 24 INCHES 610 MM TOP 1 INCH 25 MM 24 INCHES 610 MM BOTTOM REQUIRED CLEARANCE - 16 INCHES/406 MM Specifi cations subject to change without notice, all rights reserved. Monticello, Minnesota 800.922.4138 www.electromn.com 02/09/2016 BL508

STANDARD EQUIPMENT Staging - EB-CX-** Supply water sensing Regulates to front panel selected temperature Staging indicator lights Heavy duty contactors Hi-limits: 1 st - automatic reset at 190 F 2 nd - manual reset at 205 F Circulator switching relay - 10-amp maximum Thermostat or end switch connection (R and W) Utility load control provisions 13.1 gl. Steel vessel ASME H Stamp Supply temperature/pressure gauge Safety relief valve (30 PSI) Standby switch and boiler contact Outdoor reset capability Made in the USA Electro-Boiler EB-CX series Hydronic Boilers Submittal Data dimensions are: mm in. 2X 3/4"-1/2" CONDUIT 51 2" OUT 254 10" IN 1 1/4"-1" CONDUIT 64 2 1/2" 523 20 9/16" 51 2" 39 1 9/16" 52 2 1/16" 508 20" 2" NPT MOUNT THIS END UP 559 22" 533 21" 406 16" 213 40 8 3/8" 1 9/16" 889 35" 809 31 13/16" 914 36" 968 38 1/8" 64 2 1/2" 5 7/8" drain 3/4" NPT 457 18" 1 69 2 11/16" 65 2 9/16" 2X 1 1/4"-1" CONDUIT 1 minimum clearance from floor 18". 361 14 3/16"

Electro Industries Industrial Electric Water Boilers Electro Industries Industrial Boiler is a very compact and an effective solution to retrofitting old, inefficient fossil fuel boilers, or for use in new installations. Safety is one major benefit of these boilers. Several state electrical jurisdictions are requiring the (optional) Bender Insulation Monitor device (ground fault) for increased operating safety, personal protection and reliability of the boiler. Secondly, there are individual circuit breakers for each heating element, further increasing the safety and reliability of our boilers. Each boiler also includes built-in digital supply return and outdoor temperature sensors, enabling you to internally set and maintain the correct system design temperature, simplifying the installation process. Features & Benefits Pressure vessel built in accordance with the requirements of the ASME Boiler and Pressure Vessel Code (National Board and CRN registered) Compact, can easily fit through service doors High efficiency electric boiler with no combustion waste No minimum return water temperature required Individual circuit breakers for each heating element All boilers come fully assembled; control box is within front door Built-in digital temperature sensing; adjustable desired temperature allows the user to set the boiler to operate at a specific supply temperature (set point mode) Outdoor reset (can be enabled or disabled) Outdoor reset sensing and software (reset mode) Operator alarm monitor and control functions including manual resets are in the control box All parts within the boiler are rated for 60 C Optional Honeywell T775R temperature control Made in USA 0-10VDC terminal enabling control of boiler via building automation system, etc. Software and interface cable for setup, monitoring, and troubleshooting Transformer Wiring Configurations Standard boiler - add to building electrical service, 4-wire but no neutral current. All service wiring design, safety and ground fault equipment, NEC special code application, etc. are the responsibility of the installer. Standard boiler with option ground fault monitor - suitable for use with a 3-wire Delta service, dedicated utility transformer (Delta or unbonded/neutral). All control and protection needed to meet NEC Article 250 is included.

Product Specifications The electric hot water boiler shall be an Electro Industries, Inc. model number EB-NB-. The Boiler output shall be Btu/h or kw at volts three phase. Wiring within the main cabinet shall be rated at 75 C or higher. Aluminum or copper conductors may be used for field installed power wiring. The boiler shall include provisions to connect directly to utility load control. The boiler shall include a dedicated 15A 120V single phase control circuit (general service). As a preferred option the boiler (dependant upon kw) shall be wired using (2) three phase delta feeds without neutral (unbonded neutral) within the dedicated utility transformer XO terminal. All Delta 3-phase require optional Bender fault monitor. The vessel shall be wrapped with 3 insulation. The vessel shall be enclosed in a 14 gauge fully enclosed cabinet. The cabinet and vessel shall be attached to a 10 gauge structural steel base. The base includes integral fork pockets for easy maneuvering during installation. Both base and cabinet shall be painted with powder coated enamel. The cabinet shall include a full length hinged door with an included lockable T-handle. The inside dead front panel shall include an integral door safety interlock switch. The vessel shall have a capacity of 40 gallons. The vessel shall be H stamped and National Board registered with a maximum working pressure of 30 or 125 PSI. The Vessel shall have 3 NPT threaded inlet and outlet nozzles. The outlet nozzle shall be located on the top of the vessel. The inlet nozzle shall be located on the left side of the vessel. The immersion heating elements shall be installed in the top of the vessel and threaded into vessel for easy servicing (water draw-down not required). The heating elements shall be constructed using incoloy sheathing for long service life. The low-watt density heating elements shall be 30 in length. The cabinet shall have a split cover top for easy access to the heating elements. Contactors used to operate the heating elements shall be rated for 500,000 cycles. The boiler shall include mounted control enclosure. The control enclosure shall contain all boiler controls and adjustments. Operator is not required to enter main cabinet for resets or other functions. A window shall be included on the door of the control enclosure to permit viewing of monitor and alarm LED s. The control assembly shall include a six function alarm LED. The sequencer shall include provisions for stage rotation. An optional emergency stop switch can be field installed at the terminals provided in the boiler. The boiler shall include a 5-year limited warranty on the vessel and a 1-year limited warranty on the parts. The boiler shall be fully tested using standard UL834 and shall bear the CSA mark. Standard Equipment Circuit breakers, each stage Manual reset hi-limit - 220 F Auto reset limit control - 210 F Low water cut-off with manual reset Integrated ½ air vent ASME pressure relief valve, 30 or 125 psi (design pressure specified when placing order) Pressure/temperature gauge Drain pipe 3 NPT inlet and outlet, with inspection opening Incoloy sheathed heating elements, vessel top screw-in Staging indicator lights, at contactor Main supply circuit lugs Safety door interlock and lockable door latch Control Box includes: Contains all boiler controls and adjustments Bender fault monitor (optional) Manual reset low water cut-off Hi-limit reset button Temp Sensing & Alarm board T775R controller (optional) Alarm and alarm LED s Sequencer up to 15 stages Progressive staging delay time 0-10VDC for external boiler control Built-in load management controls

Electric Supply Model Volts kw Flow Rate Amps 3-Phase Element Btu/h Watts Steps @20 T Quantity Output Feed #1 Feed #2 Required GPM EB-NB-72-600 600 72 70-72,000 6 6 @ 12 245,736 25 690 EB-NB-84-600 600 84 81-84,000 7 7 @ 12 286,692 29 695 EB-NB-108-600 600 108 93 12 108,000 9 9 @ 12 368,604 37 700 EB-NB-120-600 600 120 93 24 120,000 10 10 @ 12 409,560 41 705 EB-NB-144-600 600 144 93 46 144,000 12 12 @ 12 491,472 49 710 EB-NB-160-600 600 160 154-160,000 8 8 @ 20 546,080 55 695 EB-NB-200-600 600 200 154 39 200,000 10 10 @ 20 682,600 68 700 EB-NB-240-600 600 240 154 77 240,000 12 12 @ 20 819,120 82 705 EB-NB-300-600 600 300 154 135 300,000 15 15 @ 20 1,023,900 102 710 EB-NB-300-600H 600 300 154 135 300,000 13 13 @ 23 1,023,900 102 750 EB-NB-84-480 480 84 101-84,000 7 7 @ 12 286,692 29 695 EB-NB-108-480 480 108 116 15 108,000 9 9 @ 12 368,604 37 700 EB-NB-120-480 480 120 116 29 120,000 10 10 @ 12 409,560 41 705 EB-NB-144-480 480 144 116 58 144,000 12 12 @ 12 491,472 49 710 EB-NB-160-480 480 160 193-160,000 8 8 @ 20 546,080 55 695 EB-NB-200-480 480 200 193 48 200,000 10 10 @ 20 682,600 68 700 EB-NB-240-480 480 240 193 96 240,000 12 12 @ 20 819,120 82 705 EB-NB-300-480 480 300 193 169 300,000 15 15 @ 20 1,023,900 102 710 EB-NB-300-480H 480 300 193 169 300,000 13 13 @ 23 1,023,900 102 750 EB-NB-60-208 208 60 167-60,000 4 4 @ 15 204,780 21 716 EB-NB-75-208 208 75 209-75,000 5 5 @ 15 255,975 26 721 EB-NB-105-208 208 105 292-105,000 7 7 @ 15 358,365 36 721 EB-NB-150-208 208 150 292 125 150,000 10 10 @ 15 511,950 50 731 EB-NB-180-208 208 180 292 210 180,000 12 12 @ 15 614,340 61 737 EB-NB-60-240 240 60 145-60,000 4 4 @ 15 204,780 20 716 EB-NB-75-240 240 75 181-75,000 5 5 @ 15 255,975 26 721 EB-NB-105-240 240 105 253-105,000 7 7 @ 15 358,365 36 721 EB-NB-150-240 240 150 289 73 150,000 10 10 @ 15 511,950 51 731 EB-NB-180-240 240 180 289 145 180,000 12 12 @ 15 614,340 61 737 Actual calculated amps, not service rating. Options EB-N-GFM-KIT - Ground fault monitor kit. ONLY suitable for use with dedicated 3-wire Delta service with unbonded neutral. Not suitable for WYE service or non-dedicated 3-wire Delta. EB-NB-***-***H - 125 psi vessel and relief valve. Boiler Weight Specifi cations subject to change without notice, all rights reserved. Monticello, Minnesota 800.922.4138 www.electromn.com 04/24/2015 BL801