FAN UNIT FH4A Sizes 001 thru 004

Similar documents
Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Installation Instructions

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Installation Instructions

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

FEM4X. Product Specifications FAN COILS /14/15

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--

Installation Instructions

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

WAHL A Product Specifications

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Dimensions H x W x D in. (mm)

Installation Instructions

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

FXM4X. Product Specifications FAN COILS FXM4X

REM4P, REM4X. Product Specifications

Installation Instructions

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Product Data. HUM Humidifiers

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

FCM4X. Product Specifications

FUSE COVER CLIP LATCH (OMITTED ON 18-K3N)

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

Ruud Standard Efficiency Air Handler

HIGH EFFICIENCY AIR HANDLER

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Ruud Standard Efficiency Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

INSTALLATION INSTRUCTION

Rheem Standard Efficiency Air Handler

HIGH EFFICIENCY AIR HANDLER

Rheem High Efficiency Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

395CAV Sizes 045 thru 155 Series H and J

Table of Contents. Page 2

Electric Heat Accessory Installation Instructions

Product Data MECH. Mechanical Filter Air Cleaner

Rheem High Efficiency Air Handler

Ruud High Efficiency Air Handler

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Cooling/Heat Pump Convertible Air Handlers

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Cooling/Heat Pump Convertible Air Handlers

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

Installation Instructions

Product Data. FE4A, FE5A Infinityr Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

MODELS B1PA024, 030 AND 036

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

36,000-62,000 BTUH Nominal Capacity

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Transcription:

FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging from 800 to 2000 CFM. The units are the right choice if you need versatility and affordability in a fan unit. These fan coil units offer an air handler for practical, no-nonsense application and outstanding performance. The multipoise units allow greater flexibility to meet your upflow, downflow, or horizontal installation requirements, and offer multiple electric entry to permit quick, hassle-free hookup (003 and 004 when coupled with coil are upflow/downflow only). All models come fully equipped with solid-state cooling controls. The FH4A, with its 3-speed motor and field-installed heater package, provides the application versatility required for most installations. Heater packages are available from 3- through 30- kw, either fused or with a circuit breaker, or non-fused for 10-kw and less. Form No. PDS FH4A.01.4

FEATURES Prepainted galvanized sheet metal Cooling controls with every unit 3-speed motor Factory-supplied cleanable filter Easy access filter for cleaning no tools required Field-installed heater packages 3- through 30-kw, fused, circuit breaker, non-fused (10-kw and down) Factory-supplied power plug Control board with replaceable 5-amp blade type auto fuse Foil-faced high-density super thick R-4.2 insulation Multiple electric entry HUD approved for manufactured housing 40-va, 208/230-v transformer All models listed with UL, cul, ARI, and RADCO MODEL NUMBER NOMENCLATURE F H 4 A N F 001 015 AEAA F Fan Coil H Fan Unit 4 Multipoise A Original Series N 208/230-1-60 001 1800 CFM 002 1200 CFM 003 1600 CFM 004 2000 CFM F Single Piece Cabinet with 1 in. Super Thick Insulation Electric Heater (kw) 003 015 005 020 008 024 009 030 010 A Common Unit E Minor Engineering Change A Standard Unit A Standard Unit UNITARY HEAT PUMP UNITARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION LISTING TESTING INSPECTION CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. REGISTERED QUALITY SYSTEM 2

DIMENSIONS TOP VIEW 7 8 DIA KNOCKOUTS FOR LOW VOLTAGE CONTROL WIRING 1 7 8 1 NOTE: Allow 21 In. from front for service. 22 1 16 1 15 16 15 16 C B 1 3 8 7 8, 1 3 32, 2 DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING 2 1 8 10 3 16 11 1 OUTLET AIR 7 8 DISCONNECT OR CIRCUIT BREAKER LOCATION 3 4 BLOWER, CONTROL, & ELECTRIC HEATER ACCESS PANEL ALTERNATE 7 8 DIA KNOCKOUT FOR LOW VOLTAGE ACCESS PANEL CONTROL WIRING ALTERNATE 7 8, 1 3 32, 2 DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE A FITTING PANEL OPENING 1 F INLET AIR FRONT VIEW FILTER ACCESS PANEL 1 1 4 19 13 OPENING 16 INLET AIR RIGHT SIDE VIEW A95533 UNIT SERIES A B C F ACCY. COIL CONFIGURATION In. In. In. In. SLOPE A OPERATING WEIGHT (Lb) FH4ANF001 E 42-11/16 14-5/16 12-7/16 12-5/16 175 FH4ANF002 E 49-5/8 17-5/8 15-3/4 15-5/8 192 FH4ANF003 E 49-5/8 21-1/8 19-1/4 19-1/8 106 FH4ANF004 E 53-7/16 21-1/8 19-1/4 19-1/8 114.5 3

DIMENSIONS Continued * HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM, HOLES PROVIDED.136 IN. DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. 1 13 16 AIRFLOW 7 16 TYP (4 PLACES)* 1 TYP (2 PLACES)* 1 2 5 16 2 3 16 TYP (2 PLACES)* 7 8 HORIZ LEFT UPFLOW AIRFLOW 2 3 16 TYP (2 PLACES)* 5 16 1 TYP (2 PLACES)* 7 16 TYP (4 PLACES)* DOWNFLOW 1 13 16 1 1 2 HORIZ RIGHT 1 2 7 8 A95534 4

DIMENSIONS Continued POWER ENTRY OPTIONS FIELD SUPPLIED SUPPLY DUCT LOW VOLT ENTRY OPTIONS 24-IN. FRONT SERVICE CLEARANCE UNIT FH4A001 FH4A002 A 12 In. 17 In. 1 1 2 19 2 1 2 A FIELD MODIFIED SIDE RETURN LOCATION FOR SLOPE COIL UNITS ONLY FIELD SUPPLIED RETURN PLENUM A98526 *Side Return not compatible when used in conjunction with accessory cooling coil Field-modified Side Return Location For Slope Coils Only 5

SPECIFICATIONS UNIT SIZE 001 002 003 004 FAN Air Discharge CFM (Nominal) Motor Hp (PSC) 850 1/4 FILTER 21-1/2 x 13 21-1/2 x 16-3/8 21-1/2 x 19-7/8 1300 1/3 1700 3/4 2000 3/4 SIZE FH4A001 FH4A002 FH4A003 FH4A004 AIRFLOW PERFORMANCE* (CFM) EXTERNAL STATIC PRESSURE (IN. WC) BLOWER 0.10 0.20 0.30 0.40 0.50 0.60 SPEED 208 230 208 230 208 230 208 230 208 230 208 230 HIGH 1173 1270 1135 1225 1090 1170 1045 1126 993 1058 925 981 MED 900 1025 875 991 847 963 810 922 768 869 695 802 LOW 579 687 560 663 537 639 505 610 451 554 384 467 HIGH 1630 1841 1605 1798 1567 1748 1525 1696 1480 1629 1415 1560 MED 1244 1438 1225 1407 1190 1383 1170 1342 1141 1308 1100 1265 LOW 1001 1172 985 1147 955 1116 930 1094 908 1062 850 1024 HIGH 2118 2060 2202 1949 2106 1853 1989 MED 1757 2061 1745 2016 1734 1985 1716 1943 1686 1890 1624 1802 LOW 1290 1535 1286 1535 1281 1528 1277 1515 1263 1467 1245 1431 HIGH 2257 2235 2188 2113 2336 MED 1930 2215 1914 2196 1887 2163 1838 2106 1787 2047 LOW 1620 1881 1620 1870 1613 1864 1607 1853 1594 1836 1562 1802 * With factory approved filter, 10-kw elec heat 001 and 002 sizes, 15-kw elec heat 003 and 004 sizes 230-volt. MODEL AND SIZE FH4A001 WITH KFAEC0101024 FH4A002 WITH KFAEC0201036 FH4A003 WITH KFAEC0301048 FH4A004 WITH KFAEC0401060 BLOWER MOTOR SPEED AIRFLOW PERFORMANCE WITH ACCESSORY COIL (CFM) EXTERNAL STATIC PRESSURE (IN. WC) 0.10 0.20 0.30 0.40 0.50 0.60 208 230 208 230 208 230 208 230 208 230 208 230 HIGH 945 975 900 930 840 870 780 805 695 725 560 595 MED 835 900 795 855 745 800 690 740 610 650 470 510 LOW 605 695 575 665 530 625 485 580 425 510 340 395 HIGH 1485 1550 1425 1490 1365 1420 1300 1350 1230 1275 1150 1190 MED 1235 1380 1200 1325 1160 1265 1110 1210 1055 1140 985 1070 LOW 1035 1185 1010 1150 980 1115 940 1070 890 1010 825 935 HIGH 1880 1935 1785 1830 1700 1735 1615 1645 1520 1555 1430 1460 MED 1740 1840 1660 1750 1585 1660 1510 1575 1435 1485 1350 1390 LOW 1425 1605 1395 1555 1360 1495 1315 1430 1255 1360 1170 1270 HIGH 2145 2245 2085 2185 2030 2115 1965 2045 1905 1975 1830 1895 MED 2025 2175 1970 2110 1915 2050 1860 1990 1805 1905 1740 1830 LOW 1680 1895 1655 1855 1625 1810 1595 1765 1555 1705 1500 1645 NOTES: 1. Airflow based upon dry coil at 230v with factory approved accessory filter and electric heater (10-kw electric heat, sizes 001 and 002; 15-kw electric heat, sizes 003 and 004). 2. Not recommended for use above 0.60 in external static pressure. Airflows in this region have the potential for condensate to blow out of the drainpan. If usage in this region is desired, consult duct pressure graph for allowable return and supply duct static pressures. Airflows in this region are outside recommended airflow for all applications. Usage at these airflows could result in condensate blowing out of the drainpan. FILTER STATIC PRESSURE DROP (IN. WC) CFM UNIT SIZE 400 600 800 1000 1200 1400 1600 1800 2000 001 0.044 0.075 0.110 002 0.072 0.100 0.130 003 0.092 0.120 0.152 004 0.120 0.152 0.187 6

0.6 0.5 TOO HIGH TOTAL STATIC PRESSURE (AIRFLOW TOO LOW) SUPPLY STATIC PRESSURE, IN.W.C. 0.4 0.3 0.2 ACCEPTABLE RANGE TOO HIGH RETURN STATIC PRESSURE (DIFFICULT TO MAKE TRAP) 0.1 TOO HIGH AIRFLOW* (WATER MAY BLOW OUT OF PAN PRIOR TO MAKING TRAP] 0 0 0.1 0.2 0.3 0.4 0.5 0.6 RETURN STATIC PRESSURE, IN.W.C. Acceptable Duct Conditions For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed with duct systems which fall within the Acceptable Range illustrated above. These acceptable duct conditions apply to FH4 units used with accessory evaporator coils. A96027 * Operation in this Too High Airflow range (below.2 supply static) do not apply to FH4. FAN COIL ELECTRICAL DATA (UNITS WITHOUT ELECTRICAL HEAT) UNIT VOLTS MIN CKT BRANCH CIRCUIT Min Wire SIZE (1 PHASE) FLA AMPS Size AWG* Fuse Amps 001 208/230 1.8 2.3 14 15 002 208/230 2.7 3.4 14 15 003 208/230 4.3 5.4 14 15 004 208/230 5.4 6.8 14 15 * Use copper wire only. 75 C must be used in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60 C conductors, instead of wire sizes shown in table above per NEC 1999 Article 336-26. FLA Full Load Amps NOTE: If branch circuit wire length exceeds 100 ft., consult NEC 215-2 to determine maximum wire length. Use 2% voltage drop. 7

ELECTRIC HEATER INTERNAL PROTECTION* HEATER PHASE FUSES QTY/SIZE CKT BKR QTY/SIZE 3 1 5 1 1/60 8 1 1/60 10 1 1/60 15 1 2/30 2/60 2/60 20 1 4/60 2/60 24 3/1 6/60 30 3/1 6/60 9 1/3** 15 3 18 3 * 5-, 8-, 10-kw factory-installed heat has no internal protection. 15-kw factory-installed heat is internally protected with fuses. ** KFCEH1401N09 is single phase only. Circuit breakers are 2 pole. ELECTRIC HEATERS INTERNAL CIRCUIT PROTECTION HEATER PART NO. @ 240V VOLTS/PHASE / STAGE FAN COIL SIZE USED WITH KFAEH0101N03 KFCEH0401N03 3 230/1 3 None 001 9,400 KFAEH0201N05 KFCEH0501N05 5 230/1 5 None 001, 002 15,700 KFAEH0301N08 KFCEH0801N08 8 230/1 8 None 001 004 25,100 KFAEH0401N10 KFCEH0901N10 10 230/1 10 None 001 004 31,400 KFAEH0601F20 KFCEH1801F20 20 230/1 10, 10 Fuse 002 004 62,800 KFAEH0801315 KFCEH1601315 15 230/3 5, 10 None 002 004 47,100 KFAEH0901318 KFCEH2001318 18 230/3 6, 6, 6 None 003, 004 56,500 KFAEH1001F24 KFCEH2101F24 24 230/3* 8, 8, 8 Fuse 003, 004 75,300 KFAEH1101F30 KFCEH2201F30 30 230/3* 10, 10, 10 Fuse 003, 004 94,100 KFAEH1301C05 KFCEH0601C05 5 230/1 5 Circuit Breaker 001, 002 15,700 KFAEH1401C08 KFCEH1001C08 8 230/1 8 Circuit Breaker 001, 002 25,100 KFAEH1501C10 KFCEH1101C10 10 230/1 10 Circuit Breaker 001 004 31,400 KFAEH1701C20 KFCEH1901C20 20 230/1 10, 10 Circuit Breaker 002 004 62,800 KFAEH2501N09 KFCEH1401N09 9 230/1 3, 6 None 002 004 28,200 KFAEH2601F15 KFCEH1501F15 15 230/1 5, 10 Fuse 001 004 47,100 KFAEH2801C15 KFCEH1701C15 15 230/1 5, 10 Circuit Breaker 001 004 47,100 HEATING CAP. ** @ 230V * Field convertible to 1 phase. KFAEH2501N09 is field convertible to 3 phase. Single point wiring kit required for these heaters in Canada. ** Blower motor heat not included. SMART HEAT INTERNAL CIRCUIT PROTECTION HEATER PART NO. @ 240V VOLTS/PHASE / STAGE FAN COIL SIZE USED WITH KFAEH2201H10 KFCEH0101H10 10 230/1 4, 6 None 001, 002 31,400 KFAEH2301H15 KFCEH0201H15 15 230/1 3, 8, 4 Fuse 001 003 47,100 KFAEH2401H20 KFCEH0301H20 20 230/1 5, 10, 5 Fuse 002 004 62,800 HEATING CAP. ** @ 230V When using units with 20-, 24-, and 30-kw electric heaters, maintain a 1-in. clearance from combustible materials to discharge plenum and ductwork, and maintain a distance of 36 in. from the unit. Use an accessory downflow base to maintain proper clearance on downflow installations. Use flexible connectors between ductwork and unit to prevent transmission of vibration. When electric heater is installed, use heat resistant material for flexible connector between ductwork and unit at discharge connection. Ductwork passing through unconditioned space must be insulated and covered with vapor barrier. 8

ELECTRIC HEATER ELECTRICAL DATA BRANCH CIRCUIT HEATER INTERNAL HEATER AMPS Min Ampacity Min Wire Size (AWG) Min Gnd Wire Size Max Fuse/Ckt Bkr Amps Max Wire Length PHASE CIRCUIT ** (Ft) PART NO. PROTECTION Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit 240v 208v Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 KFAEH0101N03 KFCEH0401N03 3 2.3 1 None 10.9/12.0 15.9/17.3 12/12 12/12 20/20 67/68 KFAEH0201N05 1 KFCEH0501N05 1 5 3.8 1 None 18.1/20.0 26.0/28.4 10/10 10/10 30/30 66/66 KFAEH0201N05 2 KFCEH0501N05 2 5 3.8 1 None 18.1/20.0 31.2/33.5 8/8 10/10 35/35 85/88 KFAEH1301C05 1 KFCEH0601C05 1 5 3.8 1 Ckt Bkr 18.1/20.0 26.0/28.4 10/10 10/10 30/30 66/66 KFAEH1301C05 2 KFCEH0601C05 2 5 3.8 1 Ckt Bkr 18.1/20.0 31.2/33.5 8/8 10/10 35/35 85/88 KFAEH0301N08 KFCEH0801N08 8 6.0 1 None 28.9/32.0 44.7/48.5 8/8 10/10 45/50 59/60 KFAEH1401C08 KFCEH1001C08 8 6.0 1 Ckt Bkr 28.9/32.0 44.7/48.5 8/8 10/10 45/50 59/60 KFAEH2501N09 *** KFCEH1401N09*** 9 6.8 1 None 32.8/36.0 49.5/53.5 8/6 10/10 50/60 54/87 9 6.8 3 None 18.8/20.8 32.0/34.5 8/8 10/10 35/35 83/85 KFAEH0401N10 KFCEH0901N10 10 7.5 1 None 36.2/40.0 53.8/58.5 6/6 10/10 60/60 78/80 KFAEH1501C10 KFCEH1101C10 10 7.5 1 Ckt Bkr 36.2/40.0 53.8/58.5 6/6 10/10 60/60 78/80 KFAEH2601F15*** KFCEH1501F15*** 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 KFAEH2801C15*** KFCEH1701C15*** 15 11.3 1 Ckt Bkr 36.2/40.0 18.1/20.0 53.8/58.5 22.7/25.0 6/6 10/10 10/10 10/10 60/60 25/25 78/80 75/76 KFAEH0801315 KFCEH1601315 15 11.3 3 None 31.3/34.6 47.7/51.8 8/6 10/10 50/60 56/90 KFAEH0901318 KFCEH2001318 18 13.5 3 None 37.6/41.5 55.5/60.4 6/6 10/8 60/70 76/77 KFAEH0601F20 KFCEH1801F20*** 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 KFAEH1701C20 KFCEH1901C20*** 20 15.0 1 Ckt Bkr 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 6/6 8/8 10/10 10/10 60/60 50/50 78/80 59/59 KFAEH1001F24 *** KFCEH2101F24 *** KFAEH1101F30 *** KFCEH2201F30 *** 24 18.0 3 Fuse 50.1/55.4 71.2/77.8 4/4 8/8 80/80 94/95 24 18.0 1 Fuse 86.7/95.5 116.9/127.9 1/1 6/6 125/150 115/116 30 22.5 3 Fuse 62.6/69.2 86.8/95.0 3/3 8/8 90/100 97/98 30 22.5 1 Fuse 109.0/120.0 144.8/158.5 0/00 6/6 150/175 117/150 SMART HEAT ELECTRICAL DATA BRANCH CIRCUIT HEATER INTERNAL HEATER AMPS Min Ampacity Min Wire Size (AWG) Min Gnd Wire Size Max Fuse/Ckt Brk Amps Max Wire Length PHASE CIRCUIT ** (Ft) PART NO. PROTECTION Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit 240v 208v Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 KFAEH2201H10 KFCEH0101H10 10 7.5 1 None 32.5/35.9 44.0/48.3 8/8 10/10 45/50 60/61 KFAEH2301H15 KFCEH0201H15 15 11.3 1 Fuse 54.2/59.9 39.7/43.9 14.4/16.0 73.2/80.3 49.7/54.9 23.4/25.4 4/4 8/6 10/10 8/8 10/10 10/10 80/90 50/60 25/30 92/92 53/85 73/74 KFAEH2401H20 KFCEH0301H20 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 97.2/106.7 52.0/56.8 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 87/111 81/82 93/93 FIELD MULTIPOINT WIRING OF 24-AND 30- SINGLE PHASE HEATER AMPS MIN AMPACITY MIN WIRE SIZE (AWG) MIN GND MAX FUSE/CKT BKR AMPS MAX WIRE LENGTH HEATER PART NO. PHASE ** WIRE SIZE (FT) 240V 208V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 KFAEH1001F24 KFCEH2101F24 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 KFAEH1101F30 KFCEH2201F30 30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 Field convertible to 1 phase, single or multiple supply circuit. Field convertible to 3 phase. ** Includes blower motor amps of largest fan coil used with heater. Copper wire must be used. If other than uncoated (non-plated), 75 C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. *** Heaters are Intelligent Heat capable when used with the FK, FV fan coils and corporate 2-speed programmable thermostat (TSTATBBP2S01-A), or Thermidistat Control (TSTATBBPRH01-B). NOTES: 1. For fan coil sizes 018-036. 2. For fan coil sizes 042-060 and all FK4C, FV4A sizes. 3. Single circuit application of F15 and F20 heaters requires single-point wiring kit accessory 9

ELECTRIC HEATER STATIC PRESSURE DROP The airflow performance data was developed using fan coils with 10-kw electric heaters (2 elements) in the 001 and 002 size units and 15-kw heaters (3 elements) in the 003 and 004 size units. HEATER ELEMENTS 001, 002 003, 004 EXTERNAL STATIC PRESSURE CORRECTION EXTERNAL STATIC PRESSURE CORRECTION HEATER ELEMENTS 0 0 +0.02 0 0 +0.04 1 3, 5 +0.01 2 8, 10 +0.02 2 8, 10 0 3 9, 15 0 3 9, 15 0.02 4 20 0.02 4 20 0.04 6 18, 24, 30 0.10 The airflow performance data was developed using fan coils with 10-kw electric heaters (2 elements) in the 001 and 002 units and 15-kw heaters (3 elements) in the 003 and 004 units. For fan coils with heaters of a different number of elements, the available external static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. * Factory authorized and listed, field-installed. ACCESSORIES ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH Disconnect Kit KFADK0101DSC Cooling Controls and Heaters 3-kw through 10-kw Downflow Base Kit KFACB0101CFB 001 KFACB0201CFB 002 KFACB0301CFB 003, 004 Downflow Conversion Kit KFADC0201SLP Slope Coil Units 001, 002 KFADC0401ACL A-Coil Units 003, 004 Single-Point Wiring Kit KFASP0101SPK Only with 15- and 20-kw Fused Heaters Filter Kit (12 pack) KFAFK0112SML 001 KFAFK0212MED 002 KFAFK0312LRG 003, 004 Evaporator Coil KFAEC0501024 001 KFAEC0601036 002 KFAEC0301048 003 KFAEC0401060 004 Accessory Kits Description Suggested and Required Use 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: FH4 units for 3-kw through 10-kw electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1-in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap free seal with the floor. REQUIRED USE: This kit must be used whenever FH4 fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A-coils. REQUIRED USE: This kit must be used whenever FH4A fan coils are used in downflow applications. 4. Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavygage, high-voltage wires into the fan coil rather than 4 light-gage, high-voltage wires. SUGGESTED USE: FH4 fan coils with 15-kw and 20-kw fused heaters only. 5. Fan Coil Filter The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevent them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efficiency of the system. SUGGESTED USE: To replace filters in FH4 fan coils. 6. Evaporator Coil Kit The kit contains a heating/cooling coil and drain pan. SUGGESTED USE: Accessory coil used with FH4A fan unit. 10

MATCHED SYSTEM HEAT PUMP VENTILATOR PLUS ZONE PERFECT PLUS EQUIPMENT CONTROLLER HUMIDIFIER FAN COIL AIR CLEANER A98065 11

SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-962-9212 [ ] Packaged Service Training [ ] Classroom Service Training A94328 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS FH4A.01.3B 1998 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 PRINTED IN U.S.A. Catalog No. 12FH-4A0 10-98 12