BIG BEAR VORTEX FAN MODEL #BB-2

Similar documents
THANK YOU FOR PURCHASING A B-AIR PRODUCT.

PROFESSIONAL AIR MOVER OWNER S MANUAL

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

LOW PROFILE AIR MOVER

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

P-200T / P-200AT / P-230AT (115V / 60Hz)

16 OUTDOOR MISTING FAN

1 HP Air Mover. Owner s Manual

30 Misting/Oscillating Fan Model Number 01030

Model: B-55 (115V/60Hz)

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

OWNER S MANUAL #DC2000B #DC2000BCF

High-Velocity Floor Fan

owner s manual & parts list

Operating Instructions & Parts Manual Models 99533, 99532

20 High Velocity Fan with 135 Tilt Head

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

Professional Warming Drawer and Warming Drawer Cabinet

User s Manual and Operating Instructions

Instruction Manual Item No.: V~, 60Hz

OmniDry 2.9 Amp Centrifugal Air Mover

177 Can Beverage Cooler

Suntec. Infrared HomeHeating System. Model. Thermal Design

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

- Oscillating Table Model Fan

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

42 Oscillating Tower Fan with Remote Control. OWNER S MANUAL Model # FC1-42R-03

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

BLT-999W-2 Item # 60757

BG8SS. 8 Inch Slow Speed Bench Grinder with LED Lights Assembly & Operating Instructions

CLASSIC PLUS INFRARED ZONE HEATER

PORTABLE ICE MAKER. Model: IM-124S INSTRUCTION MANUAL

690 and Power Fishing Systems

22In. Oscillating Pedestal Fan. Owner s Manual

24 & 30 Quiet Design Oscillating Wall Mount Fan

16 Stand Fan with Remote Control Model No: FS3-40R-30

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

Quest Power Electric Heat EHS 62 Pro

ULTRASONIC HUMIDIFIER

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

User s Manual and Operating Instructions

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Operating Instructions

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Installation Guide. Manufactured for Aero-Spa, LLC Web:

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

GALE FORCE VAF-16R. Ventilation Manual

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

Instruction Manual Item No.: V~, 60Hz

96 Can Beverage Cooler

ULTRASONIC HUMIDIFIER

MINI CERAMIC TOWER HEATER Instruction Manual

E1.5 ELECTRIC FAN HEATER

BG6UL. 6 Inch Bench Grinder Assembly & Operating Instructions

Electronic 18 Watt High Efficiency UV-A Lamp

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

The FAWSsit USER CARE GUIDE

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

FOR THE FOLLOWING MODELS : EE-7588R EE-7588W EE-7588O EE-7588B EE-7588M

SolidFlo G2 Solid Handling Pumps Product Manual

OWNER S MANUAL. General Ventilation Fans Electric Driven. PAL Series (Incl. 24 & 30) HD Series (Incl. -T & -S) 0316_01A

Stand Fan. English. Owner s Guide. Model F R

7.5A Electric Blower EN Souffleuse électrique 7,5 A Soplador eléctrico de 7,5 A P05 P00 P00 WG506 HELPLINE NUMBER WORX (9679)

Service Manual Models CPH2 & CPH3

40E ELECTRIC FAN HEATER

FM-17DS & FM-20DS FLOOR MACHINES

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

SSS BPV- 40 Backpack Vacuum

CERAMIC HEATER MODEL # EE If you have any questions about the operation of your ceramic heater, please contact Crane Customer Care.

Operating Instructions (ENG) MODEL: AM115V. Read instructions before operating the machine. AM /24/00

Electrical Fireplace Stove with Heater

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

IMPORTANT SAFETY INFORMATION

PERSONAL CERAMIC HEATER

UB20 12V DC. Owner s Manual

Rechargeable UV-A LED/Emergency Light

Owner s. Coolerr. comply. To view

Micro-Computer Induction Cooktop SR-1885SS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

690 Power Fishing System

MINI ELECTRIC CONVECTION HEATER

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

Zeus Extreme Owner's Manual

Transcription:

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-2 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING PLEASE READ AND SAVE THESE INSTRUCTIONS

MODEL #BB-2 YOUR NEW BIG BEAR FAN HAS A 3/4 HP HIGH EFFICIENCY MOTOR WITH THE FOLLOWING FEATURES: STATE OF THE ART CONSTRUCTION. SAFETY SCREENS ON OPEN VENTS. EASY TO USE CARRYING HANDLE WIDE BASE, FOR STABILITY BUILT IN PULL STRAP FOR EASE OF MOVING BUILT IN (LOCKING) WHEELS. 2 SPEED SWITCH. 3 BUILT IN WIND STABILIZING POLE RECEPTACLES. PRE-DRILLED 5/16 HOLE IN CENTER OF FAN GRILL TO ACCOMMODATE A LIGHTING SYSTEM. OPERATION/USE A) CAREFULLY PLACE THE BIG BEAR FAN UNIT ON A STABLE FLAT DRY SURFACE DURING OPERATION. B) THE BIG BEAR FAN IS EQUIPTED WITH A 2 VELCRO AROUND THE OUTER PERIMETER OF THE FAN S EXHAUST PORT. C) BIG BEAR FAN OPERATION MUST BE SUPERVISED AT ALL TIMES. STORAGE STORE UNIT INDOORS IN A CLEAN DRY ENVIRONMENT TO ENSURE LONG LIFE WARNING BIG BEAR FAN MUST BE SUPERVISED AND ATTENDED AT ALL TIMES. THE USE OF A 3-PRONG TO 2-PRONG ADAPTER IS PROHIBITED. ONLY USE A 2-PRONG TO 2-PRONG ADAPTER. IF THE POWER SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD. 2

SAFETY 1) KEEP CHILDREN AND PETS AWAY FROM UNIT WHILE IN OPERATION AND/OR PLUGGED IN. 2) DO NOT PUT FINGERS OR OTHER OBJECTS IN UNIT WHILE IN OPERATION AND/OR PLUGGED IN. 3) TO AVOID ELECTRIC SHOCK DO NOT OPERATE IN POOLED WATER 4) NEVER PULL THE FAN BY THE POWER CORD (USE THE PULL STRAP) 5) MOTOR MUST BE KEPT DRY AT ALL TIMES. IF UNIT BECOMES WET, THOROUGHLY DRY BEFORE NEXT OPERATION. 6) USE ONLY WITH A GROUNDED PLUG AND/OR EXTENSION CORD TO AVOID RISK OF ELECTRICAL SHOCK OR FIRE. REMEMBER NEVER TO USE A CORD WITH ANY KIND OF DAMAGE OR WEAR. 7) MAKE SURE THE POWER SOURCE IS SUFFICIENT TO MEET THE REQUIREMENTS OF THE BLOWER. 8) TO PREVENT OVERHEATING THE UNIT, KEEP AIR INTAKES CLEAR AT ALL TIMES 9) CLOGGING OR BLOCKING THE AIR INTAKES COULD RESULT IN A FIRE OR ELECTRICAL HAZARD. 10) IN ORDER TO PREVENT INJURY DO NOT REMOVE ANY SCREENS OR SAFETY GUARDS FROM THE UNIT AND TO AVOID OBJECTS FROM COMING IN CONTACT WITH THE FAN. UNIT DAMAGE IN THIS MANNER WILL VOID YOUR WARRANTY. 11) DO NOT OPERATE UNIT CLOSE TO ANY DANGEROUS AREAS, SUCH AS EXPLOSIVE GASES, FLAMMABLES, HEATERS AND UNVENTILATED ENVIRONMENTS, WHICH MAY RESULT IN EXPLOSIONS OR ELECTRICAL HAZZARDS. 12) DO NOT USE ANY FORM OF SPEED CONTROL DEVICE AS DOING SO MAY CAUSE INJURY OR FIRE. 13) ALWAYS PLACE FAN ON A SMOOTH AND LEVELED SURFACE FOR SAFE OPERATION. 14) LOCK THE WHEELS WHEN FAN IS RUNNING 15) DO NOT USE UNIT IF DAMAGED. 16) BEFORE CLEANING OR SERVICING UNPLUG UNIT. 17) ALL FANS IN OPERATION MUST BE SUPERVISED AT ALL TIMES. 18) DO NOT SIT OR STAND ON FAN UNIT. 19) UNPLUG FAN WHEN NOT IN USE. 20) MAKE SURE FAN SWITCH IS IN OFF POSITION BEFORE PLUGGING INTO THE POWER SOURCE. 21) MAKE SURE HANDS ARE DRY BEFORE HANDLING FAN OR POWER CORD. 22) ONLY A QUALIFIED ELECTRICIAN SHOULD ATTEMPT TO REPAIR / REPLACE ANY ELECTRICAL COMPONENTS. 23) DO NOT LOOK INTO FAN OPENING IN ORDER TO AVOID ANY FLYING DEBRI FROM BLOWING INTO YOUR FACE OR EYES. 3

WARRANTY 1 YEAR: B-AIR WILL COVER ALL PARTS (EXCEPT POWER CORD). WITHIN ONE YEAR OF PURCHASE B-AIR WILL PAY REPAIR COSTS AND ONE WAY UPS GROUND SERVICE SHIPPING TO YOUR LOCATION WHITHIN THE 48 CONTIGUOUS STATES. PROOF OF PURCHASE IS REQUIRED. CUSTOMER IS RESPONSIBLE FOR SHIPMENT OF DAMAGED UNIT TO B-AIR WAREHOUSE FOR REPAIR. CANADA AND NON-CONTIGUOUS STATES MUST PAY FREIGHT BOTH WAYS. 5-YEAR: B-AIR WILL COVER HOUSING FROM DATE OF ORIGINAL PURCHASE. PROOF OF PURCHASE IS REQUIRED. SERVICE IN ORDER TO RECEIVE SERVICE OR REPLACEMENT PARTS UNDER WARRANTY, YOU MUST: A) CALL FOR A RMA# (Return Merchandise Authorization Number) B) HAVE PROOF OF PURCHASE C) SHIP TO B-AIR BLOWER IF IMMEDIATE SERVICE IS REQUIRED, B-AIR WILL SHIP A REFURBISHED FAN IMMEDIATELY TO REPLACE THE ONE REQUIRING SERVICE PROVIDED A VALID CREDIT CARD IS PROVIDED AND CHARGED. ONCE WE RECEIVE YOUR FAN, WE WILL CREDIT YOUR CREDIT CARD ACCOUNT. WE WILL GLADLY REPAIR YOUR FAN AND SHIP WITHIN 24 HOURS UPON INSPECTION, WE WILL ADVISE YOU OF THE REPAIRS NEEDED AND THE COST (IF APPLICABLE). B-AIR WILL ISSUE REPAIR OR REPLACEMENT PARTS DEPENDING ON WARRANTY. CORDS 1) DO NOT USE EXTENSION CORDS FOR OUTSIDE USE. 2) USE 3 PRONG ADAPTORS THAT ARE UL AND CE APPROVED AND NOT LESS THAN 16-3 WITH GROUND FAULT CIRCUIT INTERRUPTER (GFCI). 3) DO NOT USE CORDS THAT SHOW ANY KIND OR WEAR OR DAMAGE. 4) CORDS ARE NOT COVERED BY WARRANTY. 4

BIG BEAR FAN LIMITED WARRANTY COVERS 1) BIG BEAR FAN IS COVERED AGAINST DEFECTS IN MATERIAL AND CRAFTSMANSHIP USED UNDER NORMAL INTENDED USE, TO ORIGINAL PURCHASER FOR A TERM OF (1) ONE-YEAR FROM THE ORIGINAL DATE OF PURCHASE INCLUDING PARTS, LABOR AND ONE WAY SHIPPING. 2) BIG BEAR FAN HOUSING IS COVERED FOR A TERM OF (5) FIVE FULL YEARS FROM THE DATE OF THE ORIGINAL PURCHASE. DOES NOT COVER 1) ANY SIGNS OF MISUSE INCLUDING, BUT NOT LIMITED TO ROUGH HANDLING, ABUSE, TAMPERING, IMPROPER VOLTAGE USE, AND UNAUTHORIZED MAINTENANCE AND REPAIRS. CONTACT INTERTEX, INC. / B-AIR BLOWERS 1851 TYBURN STREET GLENDALE, CA 91204 1-877-800-2247 (BAIR) FAX: (818) 242-2430 EMAIL: info@b-air.com WEB SITE: www.b-air.com 5

SPECIFICATIONS MODEL #BB-2 VOLTS 115 V 230 V CYCLE 60 Hz 50 Hz MAX AIR VOLUME 5220 CFM 5510 CFM AMPS 7.0A 5.6A MAX STATIC PRESSURE 1.9 INCH 1.9 INCH WEIGHT NET/SHIP 41/46 LBS 41/46 LBS UNIT SIZE (L x W x H) 23 x 23 x 18 23 x 23 x 18 FAN SPEED (RPM) L 3200 / H 3500 L 2500 / H 2840 MOTOR 3/4 HP 3/4 HP ATTACHED CORD (16G) 25 FT 25 FT SPEEDS 2 2 STAND HEIGHT 20 20 MAX TUBE CAPACITY 70 70 OUTLET DIMENSION 55.5 55.5 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Motor Not Running a) Switch is OFF a) Turn Switch ON b) Bad Outlet b) Check Outlet/ Change to Another Outlet c) Faulty Switch/Cord c) Call Factory for new Switch/Replace Cord Scraping Noise From fan blade a) Fan blade loose a) Call Factory for advice 6