photo by PFC Price Fan Column

Similar documents
Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Linear Floor Heaters

FDCLP2 Low Profile, Series Flow Fan Powered Terminal Unit

Technical Assignment 3 11/15/04. Executive Summary

DIGI-VAV APPLICATIONS

Direct Fired Heater Model AD Specification

Operating Room Diffuser System with Integrated LED Lighting

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Product Specifications. Vertical Floor Consoles By First Co.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Plenum Fans. Model HPA. Direct Drive

APPLICATION GUIDE BEAMS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

THE ULTIMATE ROOFTOP SOLUTION

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Temperature Control and Zoning of UFAD Systems

Underfloor Air Distribution:

WEAVE RADIANT TEXTILE PANEL. Credit Reimann Architecture

Glossary of Terms Laboratory & Fume Exhaust Fans

Water-Cooled Self-Contained Units

VertiCool Aurora Engineering Guide

VariCool VAV Engineering Guide

VERTICAL FAN COIL UNITS

Maverick II Commercial Rooftop Systems 15 to 75 tons

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Advance Release September 2009

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Air Handler Unit (AHU) Equipment Purchase and Delivery Invitation to Bid

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

SECTION AIR HANDLING UNIT

AcoustiFlo Fans: Retrofit Solutions and Beyond

RE9X Series Downflow, Upflow Electric Furnaces

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Appendices. Included in this section are

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Q-Tec TM QC-Series Chilled Water Air Conditioner

ALL PRODUCTS BROCHURE

b.) Technical Information:

Modular Supply Make-Up Air Unit

MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

4. OVERVIEW OF MECHANICAL SYSTEM

Active & Passive Beams

Split System Heat Pumps

SKYPAK II, 3 Ton Series, gives you a

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Modular Heating & Ventilating Unit Model IGX-HV

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

DESCRIPTION OF TECHNOLOGY

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

SKYPAK II Heating & Cooling Self Contained Packages

Q-TEC QC-Series Chilled Water Air Conditioner

Indirect Gas-Fired Make-Up Air

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Unimaster Dust Collectors

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Vision and Skyline Semi-custom Air Handlers

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

MB Therma-Fuser Standalone Motorized Disc VAV Diffuser

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

RoofPak Applied Rooftop Systems

Vertical Air Handler Unit

48 50 UH UA PACKAGED ROOFTOP

Multi-Path RTU-TYPE 2

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Energy Recovery with Cooling and Heating

FAN POWERED VAV TERMINALS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

Split System Cooling Units

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

Chilled Water DOAS Fan Powered Terminal Units

Florida Department of Transportation

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

HVAC DISTRIBUTION and DELIVERY SYSTEMS

SKYPAK II, 3 Ton Series, gives you a

62DA,DB,DC,DD,DE,DF07-38

Fan Arrays. White Paper. Energy Labs White Paper Series Volume 0412 Issue 001 April 2012 Rev. 0. Series

Transcription:

photo by www.mrobinsonphoto.com PFC Price Fan Column

Typical Applications The Price Fan Column (PFC) is a vertical fan unit designed to discharge into a raised access floor plenum. The unit s compact design makes it suitable for any office space looking to minimize the mechanical room foot print and maximize usable floor space. It provides localized air handling and can also help reduce the air shaft size down to fresh air only. The PFC is an ideal solution for millennial spaces seeking flexibility and optimal space utilization. Price Fan Column Product Highlights Fan Column Housing The PFC is available in various sizes and configurations in order to meet any application need. The following features lend to the versatility the PFC can offer. FEATURES Compact design Capacities range from 1,000 to 17,500 cfm Convenient access Superior acoustical performance Variable frequency drive Demand control ventilation Discharge flow monitoring Compact Design Use of vertical space frees up mechanical room floor space. A design based around fan columns can reduce the size of the mechanical room by 30% or more compared to compartmental units. Capacity Range 1,000 17,500 cfm air flow range to take care of small to large zones. Airfoil style blade fan wheel design with seven different unit sizes available to select from. Convenient Access Exterior handles make it easy to access the fan column interior. The fan assembly is on rollers facilitating any maintenance or inspection and also designed without having to remove a flex connector. Superior Acoustical Performance Quiet operation is achieved from the double wall insulated construction and acoustical pyramid discharge section. Heavy gauge steel frame provides a sturdy construction. Variable Frequency Drive (VFD) Plenum pressure can be controlled through modulating the fan speed from the VFD. Factory installed variable frequency drive and controls enclosure for reduced field installation. Demand Control Ventilation (DCV) CO 2 levels in the space can be monitored and used to control the isolated fresh air supply into each zone based on actual demand and occupancy. DCV can provide energy savings through demand based fresh air supply. Discharge Flow Monitoring A piezometer ring can be provided to measure the total air volume being supplied through the PFC. Zone based airflow monitoring allows tight and efficient control throughout the building. PFC-2

Fresh Air Fan Column Sections Mixing Box Section Return Air Coil Discharge Temperature Sensor T Mixing AIr Mixing Box Section Return Air Bypass Control Enclosure The mixing box is the most versatile section of the PFC as it can be arranged and modified to fit any application. Cooling coil and bypass arrangement will use the discharge temperature sensor located in the underfloor plenum to achieve desired set point. Fresh air connection is ducted to the top of the mixing box. Other arrangements include: -- When an open ended VAV box is being used no separate fresh air opening is needed on the fan column, fresh air is mixed with return air in the mechanical room. -- No cooling coil or no bypass is required when using an air economizer. Fan Section The fan section includes a direct drive plenum fan inside the insulated double wall housing with a factory mounted VFD and control enclosure. Fan can be modulated based on the underfloor pressure sensor to maintain a predetermined static pressure. If required the fan can also be modulated to reset the static pressure under low load conditions to minimize fan energy. Fan Section P Underfloor Pressure Sensor Discharge Section The discharge section can be provided in 2, 3 and 4 way discharge opening orientations based on location and restrictions. The height dimensions of this section can be tailored to match the floor plenum height. Discharge section comes with integrated acoustical pyramid for superior sound performance. T Temperature Sensor Discharge Section For more information visit www.priceindustries.com PFC-3

Typical System Layout Other mixing box arrangements available, see page 3. DCV signal from BAS Price Single Duct Price PIC Sensor Fresh Air Supply A Return Grille Silencer CO2 Sensor Cooling Coil Return Conditioned Filter Damper Return Grille Silencer Bypass 75 F - 80 F CO2 Sensor Filter Occupied Zone Thermostat Drain Pan 75 F Controls Enclosure and VFD 70 F Linear Floor Grille T Round Floor Displacement Diffusers P Price Power and Control Module (PCM) Pressure Sensor Discharge Air Temperature Sensor Fan Column Wiring Daisy-chained UFAD Control Wiring PFC-4 For more information visit www.priceindustries.com PFC-5

Dimensional Data PFC - Fan Column C B Size Design (cfm) Unit Width (A) 1 Overall Height (B) 2 Above Floor Height (C) 25 2,500 30 92.5 78.5 50 5,000 40 115 101 75 7,500 49 135 121 100 10,000 52 143 129 125 12,500 58 153 139 150 15,000 64 172 158 175 17,500 72 182 168 1 All units have a square cross-section. 2 All units come with a standard underfloor height of 14 in. Underfloor height may vary by job and needs to be verified prior to ordering. NOTES: 1. Dimension UH varies per order A Minimum 10" Maximum 24" 2. UL1995/CSA22.2 No. 236 Certified 3. Other mixing box arrangements available, see page 3. A Nominal Performance Data Model Maximum ESP Cooling Coil Rated Design OA Design Coil Maximum BHP with with design Fin Area Total Coil Coil PD at design (cfm) (cfm) (cfm) design coil (BHP) coil (in.w.c.) 1 (ft 2 ) Capacity 2 (MBH) (in.w.c.) 25 2,500 750 1,250 1.8 1.8 3.7 43.0 0.31 50 5,000 1,500 2,300 1.0 2.7 7.7 89.4 0.25 75 7,500 2,250 3,450 1.3 4.5 13.2 144.1 0.18 100 10,000 3,000 4,600 1.9 6.7 14.3 181.9 0.25 125 12,500 3,750 5,750 0.9 5.4 16.5 229.1 0.32 150 15,000 4,500 6,900 0.8 6.3 23.0 278.9 0.23 175 17,500 5,250 8,050 1.4 9.1 26.5 330.7 0.23 1 Maximum ESP based on average filter pressure drop and design cooling coil pressure drop with 4 discharge openings. 2 Total capacity based on design for 62 F supply air, 80/67 F db/wb return air, and 55/55 F db/wb outdoor air. Note: Sound power level data is available upon request. PFC-6

For more information visit www.priceindustries.com PFC-7

Product Improvement is a continuing endeavour at Price. Therefore, specifications are subject to change without notice. Consult your Price Sales Representative for current specifications or more detailed information. Not all products may be available in all geographic areas. All goods described in this document are warranted as described in the Limited Warranty shown at priceindustries.com. The complete Price product catalog can be viewed online at priceindustries.com. Price is a registered trademark of Price Industries Limited. 2016. Printed in Canada 2016.