DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Similar documents
CM 16. Temperature controllers with compact dimensions. Manual 42/61-72 EN Rev. 01

CM 8. Temperature controllers with compact dimensions. Manual 42/61-71 EN Rev. 01

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Installation Manual Tracker 221

I/A Series 716C 1/16 DIN Temperature Controller

SCHMIDT LED Measured Value Display MD Instructions for Use

SHIMADEN DIGITAL INDICATORS

COMMANDER 150. User Guide Universal Process Indicator A1

General Specifications

/8 DIN Level Indicator

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Temperature Controllers

DIGITAL INDICATOR JIR-301-M

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

F4 Process Controller Installation and Operation Guide

Analog Annunciator Unit SACO 16 A3. Product Guide

MO n : 12JMC rév A

Series Temperature Controller Instruction Sheet

UDC 700 Universal Digital Controllers and Indicator Specifications

Process & TeMPerATUre UniversAl input DigiTAl MeTers

CTT8 TEMPERATURE MONITOR DEVICE

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

/8 DIN Universal Process Indicator

Temperature-Relay TR210

Product Manual SZ1145

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

UDC100 Universal Digital Controller Specifications

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Nov 08 PRODUCT SPECIFICATION SHEET

02/11/2015

Operating Manual RCM420

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Product Manual SZ1144

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DIGITAL METERS Large Display Temperature Meters Instruction Manual

CLEANROOM MONITOR CR3A Network - Installation Instructions

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

DIGITAL INDICATOR DI25

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1.

Electronic Temperature Controller 70304,

Model 96VTR ¼ DIN Process Controller

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Insulation fault evaluator EDS460-DG

Specification , July 2015

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

02/11/2015

Two-Channel Gas Controller

Oxygen (O2) Single-Point Gas Detection System

Temperature Controller

FIRERAY 5000 range USER GUIDE

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

N1540 Process Indicator

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

COMMANDER 160 Wall/Pipe-mounted Universal Process Indicator. User Guide. ABB Automation

99 Washington Street Melrose, MA Phone Toll Free Visit us at

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

2-wire Passive Intelligent Loop (LED) Display Meter

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Table of Contents SECTION PAGE

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Low Temperature Zirconia Oxygen Analyzer

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

RS Pro Infrared Temperature Sensor

Instruction Manual. Aquacon Conductivity Controller / Transmitter

ST Wiring diagram. Product description. Standard temperature controller. Order number

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Beacon 800 Gas Monitor Operator s Manual

Operating Manual MS220DA

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Model 144H. Product Data Sheet , Rev DB February Content

2-wire Passive Intelligent Loop (LED) Display Meter

Transcription:

DS 96/48 P Digital indicator Short manual 41/33-89 EN Rev. 00 A1 A2 DIM E

1 Safety instructions Correct and safe operation of the apparatus calls for expert installation and meticulous maintenance. This apparatus has beeen designed and tested in accordance with IEC 1010-1 1990 and has been supplied in a safe condition. In order to retain this condition and to ensure safe operation, the safety instructions in this operating manual bearing the headline Caution" must be observed. Otherwise, persons can be endangered and the apparatus itself as well as other equipment and facilities can be damaged. Caution In order to protect against shocks, this apparatus may only be operated when fully and properly installed. 2 Commissioning elements 3 4 9 2 A1 A2 DIM 1 E 5 6 7 8 z-20240 1 Front bezel (removeable) 2 optical alarm A2 3 optical alarm A1 4 4 digit, 7 segment display 5...8 keys 9 insert dimension plate 2 Safety instructions 42/33-89 EN

Back of housing 1 2 3 4 5 6 7 8 9 10 1112 1314 15 161718 19 20 z-20241 Terminals (wire cross section max 1.5 mm 2 ) 2.1 Connections Connect the instrument according to the rating plate. Caution: Before switching on, please ensure that the operating voltage stated on the rating plate is identical with the mains voltage. Terminal assignment 1 Tx (serial interface) 11 Transmitter supply (+) 2 Rx (serial interface) 12 Transmitter supply (-) 3 Segment test 13 A1 common 4 Hold/retrace blanking 14 NC contact 5 Programming disable 15 NO contact 6 Digital GND (terminals1-5) 16 A2 common 7 Input U (+) 17 NC contact 8 Input (-) 18 NO contact 9 Input I (+) 19 N, DC (-) 10 free 20 L1, DC (+) 42/33-89 EN Commissioning elements 3

Connection diagram Power supply 20 L1 AC 19 N + DC - Segment test 3 6 Display storage (Hold) or 4 6 Display blanking 4 6 Programming stop 5 6 Measuring input Voltage 7 U+ Current 9 I+ 8 U- 8 I- Alarm relay 1 (option) 15 13 14 Alarm relay 2 (option) 18 16 17 Transmitter supply (option) 11 + 12 - Analog output (option) 1 +Tx 2 +Rx 6 Gnd Thermocouple 8 - Resistance thermometer Pt 100 / Ni 100 2-wire 3-wire 4-wire 7 I- 7 I- 7 I- 8 U- 8 U- 8 U- 7 + 9 U+ 10 I+ 9 U+ 10 I+ 9 U+ 10 I+ Relay contact positions are shown for de-energized state. 2.2 Control inputs Control inputs are activated by connecting those terminals to terminal 6. Segment test terminal 3: Indication 8.8.8.8." and A1, A2 Programming disable terminal 5: Disables programming via front keys. Hold or Blanking terminal 4 (Option): Hold: Freezes the display and stops all functions. Blanking: shuts off all digits. 4 Commissioning elements 42/33-89 EN

3 Mounting 1. Fit the unit into the panel from the front. 2. Tighten mounting brackets equally. Note The mounting brackets are designed for close packed mounting. Dimension drawing (dimensions in mm) 45-0, 5 130 120 48 96 Panel cutout 92 +0, 8 42/33-89 EN Mounting 5

4 Indication of d (min/max) and alarm values (A1, A2) If for 2 minutes no key is activated while programming, checking alarms or indicate d values the instrument always automatically falls back to normal operation modus. Check alarms Indicate min/max max value L1 A1 + min value L2 A2 Reset z-20242 6 Indication of d (min/max) and alarm values 42/33-89

5 Programming One can always re the factory values (default values) by pressing all keys simultaneously. + + + def load default z-20243 42/33-89 EN Programming 7

5.1 Programming menu via front keys + CON L10 +/-1999 Alarm A1 d01 +/-1999 lower range value L11 HI / LO Alarm A1 min/max d02 +/-1999 upper range value L12 NCC/NOC Alarm A1 ncc/noc operation d03 +/-1999 lower read out value L13 1...99 Alarm A1 hysteresis d04 +/-1999 upper read out value L14 0...9.9 Alarm A1 delay d05 0.0.0.0. Decimal point position L20 +/-1999 Alarm A2 d08 1-2-5-0 off Digit steps L21 HI / LO Alarm A2 min/max d10 ON/OFF Sign on/off L22 NCC/NOC Alarm A2 ncc/noc operation d11 0.1..9.9 Display rate L23 1...99 Alarm A2 hysteresis d12 1...8 Brightness L24 0...9.9 Alarm A2 delay z-20244 8 Programming 42/33-89 EN

5.2 Programming Example The following example shows how menu items d01...d05 can be set: A transmitter outputs a current signal between -3 ma and +17.5 ma (within standard range -20 ma to 20 ma, s.b.). A -3 ma current shall correspond to a display value of -50.0. The upper current value of 17.5 ma shall give a display value of +173.0. The device is designed such that it displays the maximum value, i.e. 1999, with the upper range value. The user can change this basic setting using the scale. Proceed as described below to configure the desired lower and upper range values (-3 ma and +17.5 ma): Add as many zeros to the end value that the display is filled completely. Example: -3 ma -300 and 17,5 ma 1750). In the overview below, the values that must be entered for some specific measuring ranges are shown. Measuring range: Value to be entered: -200 mv...+200 mvmeasured variable in mv x 10-2 V....+2 VMeasured variable in mv x 1-20 V...+20 VMeasured variable in mv x 0.1-2 ma...+2 mameasured variable in ma x 1000-20 ma... +20 ma Measured variable in ma x 10 (example) -200 ma...+200 mameasured variable in ma x 100 Also, the display range is defined as required to realize the wanted display. Set the point to the position where it is needed. The point position has no effect on other parameters, it is only a matter of display. Menu item d01, lower range value: Example above: Set to -300. (Only available for current/voltage model) 42/33-89 EN Programming 9

Menu item d02, upper range value: Example above: Set to 1750. (Only available for current/voltage model) Menu item d03, start of display range: Example above: Set to -500. (Only available for current/voltage model) Menu item d04, end of display range: Example above: Set to 1730. (Only available for current/voltage model) Menu item d05, position of decimal point: Use the and buttons to move the decimal point to the appropriate position of the display. In the example above, position "000.0" is used. 10 Programming 42/33-89 EN

6 Technical data Indication Display LED red, 13 mm high Maximum reading - 1999...+1999 digit Readout overflow OFL" Range overflow Err" Decimal point on/off, position Measuring cycle 0.1 s... 9,9 s Deviation 0.1% of value ± 1 digit at 23 C Temperature coefficient 0.05 % of value/10 C, ± 1 digit Parasitic voltage CMR > 100 db (0/50 Hz) Display control last digit 2- steps, 5- steps, fixed 0, last digit off complete readout opional Hold or Blanking display, Segment test Input Current, Voltage ± 2 ma...200 ma DC, ± 0.2 V...50 V DC Input resistance 100 Ω at 20 ma, > 150 kω at 2 V Power supply DC voltage 18...32 V DC approx. 1,8 W AC voltage 24/115/230 V AC, 50...60 Hz, approx. 3 VA Environmental capability Operating temperature 0...+ 50 C Storage temperature - 25...+ 65 C Relative humididity 75 % annual average, avoid condensation Housing Dimensions (W x H x D) 96 x 48 x 120 mm (130 mm incl. terminals) Panel cut out 92 (+0.8) x 45 (-0.5) mm Material plastic: ABS Type of protection case IP 52, terminals IP 20 42/33-89 EN Technical data 11

Weight approx. 0.4 kg Connection plug in screw terminals for 1,5 mm 2 Standards EMC, safety data EN 55011-B, EN 61010-1, EN 50082-1 Options Transmitter supply 24 V DC, max. 25 ma unregulated 2 alarm relay Relay output 4 A, 250 V Min. or Max., NO or NC operation Hysteresis, and response time programmable Indication LED-Indication 2x (A1, A2) Interface RS 232 in preparation (Configuration, viewing of values and parameters) DS 96/48 P: optionally DS 96/48 PK standard Subject to technical changes. This technical documentation is protected by copyright. Translating, photocopying and diseminating it in any form whatsoever - even editings or excerpts thereof - especially as reprint, photomechanical or electronic reproduction or storage on data processing systems or networks is not allowed without the permission of the copyright owner and noncompliance will lead to both civil and criminal prosecution. ABB Automation Products GmbH Hoeseler Platz 2, D-42579 Heiligenhaus Phone +49(0)20 56 12-51 81 Fax. +49(0)20 56 12-50 81 http://www.abb.com Subject to technical changes Printed in the Fed. Rep. of Germany 41/33-89 EN Rev. 0.0 Edition 04.01