New Silent Alert Fire Safe System

Similar documents
Silent Alert Fire Safe System

9 100% Recycled Paper

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Deaf & Hearing Impaired RadioLINK Alarm System

Smoke Vent Control Panel PCB4 V4 Installation Manual

Installation and user manual for the BiWire / Conventional Repeater Panel

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Unity DAU Voice Alarm System

SilentMAlert. ClofieldMLimited. ProductMDataMSheetsM. PagingMSystem. Silent

Installation & Operating Instructions

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers

Installation, Operating and Maintenance Manual

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

5000 INSTALLATION GUIDE

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

SMARTWALK DEMENTIA WANDERING SYSTEM

Installation & Operating Instructions

Control Panel Engineering and Commissioning Instructions

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Salamander User Guide

Water Detection Controllers

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Accessible Toilet Alarm

Emergency Assist Alarm Kit Single Zone

Loadstar AC/DC Systems

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

Firehawk Deaf Alert. Installation and Maintenance. Version 16/8/2017 New Features

Excel-EN Conventional Fire Control Panel

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

Temporary wireless battery operated fire system from Channel Safety Systems

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Installation Guide. Disabled Persons Emergency Alarm Kit. Single Zone Call Control/Call answered unit c/w Sounder LED indicators and Braille lettering

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

WARNING FIRE DOOR CLOSING

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Control Panel User Guide

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

PERMACONN PM1030 Includes DI300. Installation Manual

CFDAU30 Voice Alarm System

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

LEAKSTOPPER RANGE Multizone water leak detection systems

Engineer Paging. Staff Paging. Deaf Alert.

USER MANUAL & MAINTENANCE GUIDE OG OO

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Digital Door Entry System. Specification

Fire detection and alarm

Operating Guide. English Version 3.3

ZITON RADIO LOOP MODULE

QA16 Addressable System

SECURIT 700L PLUS ENGINEERING MANUAL

Control Panel User Guide

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

Disabled Persons Toilet Alarm Kit

THE BELLMAN & SYMFON WAY Visit technical training

PTE0705 Electric Fence Monitor

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

5000 SERIES 8 ZONE INSTRUCTION MANUAL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

ELECTRONIC SOUNDER STROBE Model : AVD-C407

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

FEC400 Series. Installation Manual

LEAKSTOPPER 1 Single zone water leak detection system

Door Release Power Supply

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

MOBILE CALL GSM Alarm System User s Manual

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

WM3000 WIRELESS MODULES

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

Intelligent addressable fire alarm control panel

Solution Ultima Series Operators Manual ISSUE 1.00

EC-P Zone Intruder Alarm System

Model 17A00 Expansion Enclosure

ORION Mini-Rep INSTALLATION MANUAL

Keep this guide in a safe place. Contents

Strikemaster ES Engineering Manual

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Installation Instructions 4 Zone Fire Panel

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Transcription:

1 New Silent Alert Fire Safe System TECHNICAL MANUAL This manual covers the FSTX-2225-EU - Fire Alarm Interface PG3A-2204-EU - Pager Unit - Fire Safe Compatible FSCH-2226-IN - Fire Safe Charger or CH3A-2205-IN Alarm Clock Charger The Fire Safe Interface Panel contains electrostatic discharge sensitive components. Observe antistatic precautions whilst ever the cover is removed.

2 TECHNICAL SPECIFICATION Introduction The Silent Alert Fire Safe System alerts people who are deaf when a fire alarm is activated; it comprises a Fire Alarm Interface and one or more vibrating pager units. The Fire Alarm Interface links to a fire alarm panel via a volt free relay and incorporates a radio transmitter. When the fire alarm is activated the transmitter within the Fire Alarm Interface sends out a coded radio signal. When a Pager receives this signal it vibrates and lights a fire key on the pager display. The system is designed to comply with all relevant parts of BS5839-1 2002 & EN54-2 and MUST be installed by a competent person as defined in BS5839-1 2002. Installation Training Installation training is available; please call us on 01246-260045 for more details. Fire Safe Interface Panel Part Number: FSTX-2225-EU Dimensions: H300mm x W240mm x D100mm Weight: Without Battery 1.90 KG - With battery 4.5KG Material: Polycarbonate self-extinguishing enclosure. Protection: Water resistant Power Supply: 240v AC 50 Hz Battery back up: 12volt lead acid 7Ah (Yuasa Type NP7-12) Dimensions (H100mmxW150mmxD65mm) Alarm Panel feed to Fire Safe Panel: Normal condition 5-30 Volts DC this can be taken from the leads within the panel. Grounded in alarm mode via an integral OPTO isolated voltage fed relay. Fault signal to Fire Panel: Via an integral normally open or normally closed volt free relay. Fault conditions: Mains failure, battery removal or charge failure, main PCB failure, radio failure Radio Compliance: In accordance with EN300 220-1. Radio Licence: Licence Exempt Range: Up to 1000m in open air Pager Unit Part Number: PG3A-2204-EU MKIII Dimensions: H63mm x W82mm x D26mm (Excluding belt clip) Weight: 74gms Material: Impact resistant ABS Power Supply: Integral NiMH 6Volt rechargeable battery pack. Charger: Intelligent boost, trickle and maintenance charging. Fault conditions: Low battery & radio failure. Radio Compliance: In accordance with EN300 220-1. Radio Licence: Licence Exempt. Range: Up to 1000m in open air. Other: Integral field strength / data validation meter for system commissioning.

3 Preliminary Radio Coverage Test INSTALLATION A preliminary radio coverage test is normally conducted prior to installation to ensure total coverage throughout a building. It is recommended that a further radio coverage test is performed prior to permanently securing the Fire Safe Panel to a wall in case it needs to be relocated. The Fire Safe panel should be mounted temporarily to a wall at between 1.5 and 1.75 meters from the ground away from large metal objects and lift shafts. For best results locate the panel central to the building. In multi-storey buildings penetrations through steel re-enforced concrete floors may be poor. In these situations coverage would be improved if the panel is located one floor above ground level to provide coverage over three floors or two levels above ground level to cover four floors. In-building coverage will vary from building to building therefore it is essential that a full and thorough radio coverage test is conducted. The range test procedure detailed later under the heading Site Survey should be followed. If it is found that the coverage is inadequate then additional Fire Safe Interfaces may need to be added. In this case it will be necessary to change the signal patterns for each panel to ensure there are no standing wave problems. This aspect is covered in more detail under the heading The use of more than one Fire Safe Panel below. Power Supply It is necessary to supply the Interface panel with a dedicated mains supply (220-240v AC 50 Hz) via its own unswitchable fused spur. The mains terminal block is located at the bottom left hand side of the main PCB and is marked Earth (top) Neutral (middle) Live (bottom). The Panel will also require a 12 Volt lead acid 7Ah back-up battery (Yuasa Type NP7-12) Dimensions (H100mmxW150mmxD65mm). It is necessary to connect the battery to the two wires with crimped connectors, before connecting the mains to avoid a fault condition.

4 Alarm Output from main Fire Alarm Panel The top terminal block on the main PCB has a RED and BLACK wire secured to the outer two terminals. The BLACK wire SHOULD NOT BE REMOVED. The RED wire must be removed and rerouted via a relay in an Input / Output Module. In alarm mode this VOLTAGE needs to be removed in order to trigger the Fire Safe Interface, therefore a normally closed contact will be required. The terminal is clearly marked GND (top/ BLACK wire) and V+ (bottom/ RED wire). It is also possible to trigger the unit by the removal of an external voltage. IF AN EXTERNAL VOLTAGE IS USED THEN BOTH THE RED AND BLACK WIRES MUST BE REMOVED FROM THE TOP TERMINAL BLOCK AND INSULTATED OR THE MAIN PCB CAN BE SERIOUSLY DAMAGED. The Interface Panel requires an external voltage of at least 5v AC or DC the maximum voltage must not exceed 30v AC or DC. RED positive feed from Main Board to normally closed relay To a normally closed relay. Open on alarm Return from normally closed relay BLACK negative feed from backup battery DO NOT REMOVE

5 Fault condition from Fire Safe Panel The Fire Safe panel has a fault output to the main Fire Alarm Panel provided via the middle terminal block. A fault condition on the Fire Safe Panel will cause a relay to be closed that will create an open circuit between common and normally closed (N/C) and a closed circuit between normally open (N/O) and common. A fault alarm will be given in the following conditions: Mains failure Battery charge failure or removal Loss of radio signal Main PCB failure Front Panel Indicator Lights Mains Green Lit when mains power present Battery Green Lit when battery present Charging Yellow Lit whilst battery is charging Fault Orange Lit when any of the above fault conditions occur Poll Yellow Lit constantly, goes out when poll signal is sent Alarm Red Lit when alarm signal received from Fire Panel Disable Orange Lit when disable key is turned to the off position Test Red Lit when in range test mode.

6 FIRE SAFE PCB LAYOUT 4 9 5 12 1 6 2 7 10 11 14 3 13 8 1. Signal In from Alarm Panel 8. Back-up Battery 2. Fault out to Alarm Panel 9. Sounder 3. Mains Input 10. Numeric Display 4. Monitor Keys 11. 3 Amp 20mm Fuse one of three 5. Transmitter PCB 12. Radio receiver 6. Master Reset Button 13. LED Indicator PCB 7. Engineer s Keys 14. Disable Key

7 Pager Unit (PG3A-2204-EU MKIII) OTHER COMPONENTS Pager front showing key pad Pager back showing key switches Fire Safe Charger Unit (FSCH-2226-IN) with Power Supply (PS3A-2207-UK) Alarm Clock Charger (CH3A-2205-IN) with Power Supply (PS3A-2207-UK)

8 SYSTEM SETUP Setup Fire Safe Interface Panel 1. Remove the front cover using a flat bladed screwdriver by loosening the four captured plastic screws in each corner. 2. The Interface contains a number of components that are susceptible to electrostatic damage. Observe antistatic precautions whilst ever the front cover is removed and avoid touching the surface of any of the PCB s. 3. Locate the Interface panel next to the main fire alarm panel at 1.5m 1.75m from the ground. Avoid locating the panel close to large metal objects and lift shafts. 4. Use the Four mounting holes shown below to secure to a wall. Do not make any additional holes in the case, as this will affect its IP rating. 5. Attach battery terminals +V Red or Brown, V Black or Blue to 12 volt lead acid battery 7Ah (Yuasa Type NP7-12) Dimensions (H100mmxW150mmxD65mm). 6. Fit three cable glands (supplied) to input / output holes on left of case. 7. Connect mains in accordance with BS5839-1 2002 to the bottom terminal block via the cable gland. 8. Remove the RED wire from the top terminal block (V in + ). 9. Reconnect it via a normally closed relay back in to the (V in +) terminal. The external relay within an input/output module should be opened in alarm mode to trigger the unit. IF AN EXTERNAL VOLTAGE IS USED THEN BOTH THE BLACK AND RED WIRES MUST BE REMOVED FROM THE TOP TERMINAL AND INSULATED. IF THIS IS NOT DONE THE MAIN PCB CAN BE SERIOUSLY DAMAGED. 10. Connect a fault wire link between the Fire Safe Interface Panel and the Fire Alarm Panel via the middle terminal block. A fault condition on the Fire Safe Panel will cause a relay to be closed that will create an open circuit between common and normally closed (N/C) and a closed circuit between normally open (N/O) and common. 11. Move Engineer s key numbered 4 to the on position. This will cause the unit to send a continuous sequence of poll signals to enable a site test as detailed later.

9 Pager Unit 1. Move keys A, B and 5 to the On position away from the belt clip as shown. 2. Switch pager on by moving the miniature key labelled OFF to the left away from the belt clip. As the Pager is switched on the battery key lights for 2 seconds then the pager should vibrate and each light on the display will light up four times. If this does not happen it may be necessary to charge the pager (see below). 3. Immediately after the set up sequence the fire key will light and the pager will vibrate three times. Thereafter the field strength will be displayed on the keypad each time a poll signal is received approximately once every four seconds. Charger Unit 1. Plug the Mains Adaptor into a 13 amp socket and connect the plug to the socket at the back of the Fire Safe or Alarm Clock Charger. Illustration shows the mains adaptor (left) and optional Pillow Pad / Strobe plug (right) connected to the charger using the strain relief features

10 2. Place Pager in charging slot to charge. Entrance Stickers Entrance stickers for wall and windows are included. These should be displayed at all entrances to the building.

11 Site Survey Radio coverage test 1. Ensure the Fire Safe is in range test mode. Engineer s key 4 in the on position. 2. Ensure the Pager is charged and in range test mode, as above. 3. Walk around the building with the pager. As the pager receives a poll signal, the keys on the pager will light. The highest signal strength will light the telephone key the lowest the battery key. It is essential that one of the keys lights up during each transmission, within the area to be covered. 4. It is possible to add additional Interface Panels on larger sites. 5. Switch Engineer s Key 4 on the Fire Safe Interface to the OFF position. 6. Switch the Pager off, move key B to the OFF position, switch the pager on again. The pager will go through its normal start up routine. 7. The fire key will flash and the pager will vibrate three times when the pager receives the first poll signal from the Interface Panel, this can take up to 4 minutes 45 seconds. The use of more than one Fire Safe Panel In larger buildings it may be necessary to have more than one Fire Safe Interface Panel. In this case it is important that the timing of the fire alarm radio signals are altered to avoid standing wave problems. A standing wave is where two radio waves meet at similar power levels and can have the affect of cancelling each other out. It is necessary therefore to overcome this phenomenon by ensuring that adjacent Fire Safe Panels do not send radio signals out at the same time. This is achieved by changing the ON / OFF periods as shown below. The Key 1 referred to below refers to the Monitor Keys not the Engineer s Keys Monitor Key 1 1 Sec 2 Sec 3 Sec 4 Sec 5 Sec 6 Sec 7 Sec 8 Sec 9 Sec Panel 1 1 OFF ON ON ON OFF OFF OFF ON ON ON Panel 2 1 ON OFF OFF OFF ON ON ON OFF OFF OFF Poll Signals The Fire Safe Panel sends a poll signal once every 4 minutes 45 seconds. This is a radio signal integrity check. The pager will expect a poll signal at least once every 5 minutes. If a signal is missed due to a fault, then the Pager will vibrate and all keys will flash six times. This will occur every five minutes whilst ever the fault remains. The Fire Safe Panel includes its own radio receiver to check the radio signal, using the same poll signal. If a poll signal is not sent the Fire Safe Panel will send a fault to the Fire Alarm Panel.

12 Daily Use The Pager Unit can be placed at reception on charge permanently. Both the Fire Safe Charger and Alarm Clock Charger have intelligent charging circuits that ensure the Pager is not overcharged. If a visitor leaves the building without returning the pager to reception the pager will vibrate and all lights will flash 6 times within 4 minutes 45 seconds to remind the user. This sequence will repeat whilst ever the pager is out of range of the system. Visitors who have their own Silent Alert Fire Safe Compatible Pagers can log onto the system by pressing the fire key on their own pager as they enter the building. Annual / Six Monthly Maintenance 1. The lead acid battery should be checked and replaced as necessary. 2. The site survey should be repeated with each Pager. 3. The Charger power supply should be PAT tested annually. 4. Check for obvious signs of wear and tear to the Pager/s, Charger/s and Fire Alarm Interface Panel. 5. During the Fire Alarm system test check that the Fire Safe Panel goes into alarm mode, indicated by the red alarm light on the front panel and that a fire signal is received by all pagers. 6. Fault condition test should be carried out as follows: - Remove mains from Fire Safe Panel Observe green mains indicator goes out and that the orange fault light comes on. - Reinstate mains power and disconnect battery lead Observe green battery and yellow charging lights go out, sounder activates and the red fault light comes on. Master Reset & Numeric Display Diagnostics Master Reset The System will recover from a fault condition when the fault has been rectified. This however can take a number of seconds. The Master Reset button can be used to clear fault conditions more quickly. Numeric Display Diagnostics

13 Move key 2 on the 4 way main interface board to the on position to activate display. This function will only operate whilst mains power is present. Ensure key 2 is returned to the OFF position before replacing the panel cover. A list of codes is shown below. = Boost Charge (Voltage and charge current levels also shown periodically) = Rapid Charge (Voltage and charge current levels also shown periodically) = Trickle Charge = Main Alarm = Battery Fault = Transmitting a radio Signal = If valid polling signal received by onboard receiver. Technical Help Line If you have any queries please call our technical help line on 01246-260045