Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

Similar documents
EC 5.10 FIRE PREVENTION MANAGEMENT

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

Agency for Health Care Administration

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

Are there any policies regarding outlets that contain USB ports?

Lauzon Life Safety Consulting

Agency for Health Care Administration

Agency for Health Care Administration

Compliance w/ the 2012 Life Safety Code

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

Iowa State Fire Marshal

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

Agency for Health Care Administration

FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

Fire & Life Safety Code Compliance. Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities

WHEA FSE inspections.

Written Fire Safety Plans

Agency for Health Care Administration

ICC CODE CORNER 2015 International Fire Code

Public. Mike Free Health. State of Alabama Department of

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Agency for Health Care Administration

Public Health Fax: Web Site:

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION

K SURVEY FOR DATE OF PLAN APPROVAL SURVEY UNDER

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

Crosswalk of 2014 HFAP Standards against HFAP Standards Acute Care Hospital Manual

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities

Emergency Planning for Institutional Facilities

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

HFAP Acute Care Hospital Manual Crosswalk of Standards against 2014 Standards

FIRE PROTECTION PROGRAM

Department of Health Life Safety Code Update

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time.

FHCA 2014 Annual Conference & Trade Show

Agency for Health Care Administration

FIRE PLAN. In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required.

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates

Barrier Management- Defending the Safety of Patients, Visitors, & Staff

Defend In Place 2012 IFC Overview of Institutional Occupancies

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Agency for Health Care Administration

LIFE SAFETY CODE MAINTENANCE MANUAL

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

NFPA 99 for Facility Managers

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Report on First Revisions with Statement June 2014 NFPA 101

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

Policies, Practices, & Procedures

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

DEALING WITH FIRE SAFETY

Fire Safety, Risks, & Response at Jackson Health System JHS Annual Mandatory Education

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

NFPA 101 Life Safety Code Culture change 2012

10/25/2018. Facilitators. Emergency Preparedness &Life Safety Code for Administrators. Participant Guide

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

Center for Clinical Standards and Quality /Survey & Certification Group

New Facilities. Minimum Requirements

FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Life Safety - Means of Egress/Exits NFPA 101

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

JOINT COMMISSION PREPAREDNESS / STATEMENT OF CONDITIONS DRAWINGS WSSHE SOUTHWEST CHAPTER NOVEMBER 19, 2015

Residential Based Care Facility Guidelines

Life Safety Codes for Assisted Living Facilities

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

Assisted Living Facilities

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

Building and Grounds Self-Inspection Program

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS

Agency for Health Care Administration

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Procedure DESCRIPTION/OVERVIEW

ASCs & LSC. Alice Epstein, DFASHRM, FNAHQ

Established /10/2015. Doran Pruisner Dan Wood

For additional information regarding R-3.1 residential care facilities please contact (951)

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

Chapter 2: Definitions

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Transcription:

Life Safety Code Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services danilo.concepcion@stjoe.org 714-771-8944 The findings and conclusions in this presentation are those of the author and do not represent the views of St. Joseph Hospital or any professional organizations

NFPA National Fire Protection Association Founded 1896 to promote the science and improve the methods of fire protection. Mission: to reduce the burden of fire and related hazards on the quality of life.

NFPA 101 (2000 Edition) LSC The LSC is a set of fire protection requirements designed to provide a reasonable degree of safety from fire. It covers construction, protection and operational features designed to provide safety from fire, smoke, and panic.

42 CFR part 494 February 9, 2009 to include LSC to standardize CMS regulatons across provider types. Not appropriate with unique characteristics of ESRD facilities

Executive Order 13563 Improving Regulations and Regulatory Review Establish a plan for ongoing retrospective review of existing significant regulations, to identify those rules that can be eliminated as obsolete, unnecessary, burdensome or counterproductive or that can be modified to more effective, efficient, flexible and streamlined.

October 24, 2011 Published a proposed rule that proposed reforms in CMS regulations that were identified as unnecessary, obsolete, or excessively burdensome to health care providers and beneficiaries. Final rule published May 16, 2012 and effective rule date: July 16, 2012

Two Changes Core Survey Limits mandatory compliance with the Life Safety Code to those End Stage Renal Disease facilities located adjacent to high hazardous occupancies and clarifies that the requirement for sprinklers in facilities housed in high rise buildings is intended to be applicable to those buildings constructed after January 1, 2008

Defend in Place Smoke compartment barriers Occupancy separations Hazardous area separations Upgraded fire alarms

Risk/Cost Analysis Original per facility government estimate: $1960 Smoke compartment barriers, occupancy separations, hazardous area separations and upgraded fire alarms. $23,500 - $222,000 Avg: $77,659/facility No recorded patient injuries or death due to fire in 40 years of Medicare ESRD program. Federal Emergency Management Agency s (FEMA) Topical Fire Report Series (TFRS) ranked ESRD facilities the lowest among all health care facilities.

Health Care Facilities Authority Having Jurisdiction (AHJ) Only the AHJ shall be permitted to grant exceptions to the requirements of NFPA provided: Technical documentation is submitted to the AHJ to demonstrate equivalency; and The system, method, or device is approved for the intended purpose. 10

Exceptions Adjacent to a high hazardous occupancy and that do not exit to grade Sprinklers: State may require

Health Care Facilities Introduction The scope of NFPA is to establish criteria to minimize the hazards of fire, explosion, and electricity in health care facilities providing services to human beings. 12

Health Care Facilities Receptacles in all patient care areas * Highly dependable grounding pole * Sufficient number of receptacles to avoid the need for extension cords or multiple outlet adapters * Each general care patient bed location minimum of four receptacles * Each critical care patient bed location minimum of six receptacles 13

Health Care Facilities Receptacles in all patient care areas *Exceptions 1. Receptacles shall not be required in bathrooms or toilet rooms. 2. Receptacles shall not be required in areas where medical requirements mandate otherwise; for example, certain psychiatric, pediatric, or hydrotherapy areas. 14

Health Care Facilities * Wet locations shall be provided with ground fault circuit interruption (GFCI) receptacles to not exceed 6 ma. 15

Health Care Facilities Receptacle testing in patient care areas at least annually * Physical integrity of each receptacle by visual inspection * Verification of continuity of the grounding circuit * Verify correct polarity of the hot and neutral connections * Verify retention force of grounding blade not less than 115 g (4 oz) 16

Health Care Facilities Electrical Equipment * Scope This chapter covers the performance, maintenance, and testing of electrical equipment used within health care facilities. 19

Health Care Facilities Manufacturer Requirements * Scope This chapter covers the performance, maintenance, and testing, with regard to safety, required of manufacturers of equipment used within health care facilities. 20

Health Care Facilities Health Care Emergency Preparedness * Scope This chapter establishes minimum criteria for health care facility emergency preparedness management in the development of a program for effective disaster preparedness, mitigation, response, and recovery. 21

Health Care Facilities Health Care Emergency Preparedness * 11-2 Purpose The purpose of this chapter is to provide those with the responsibility for disaster management planning in health care facilities with a framework to assess, mitigate, prepare for, respond to, and recover from, disasters. This chapter is intended to aid in meeting requirements for having an emergency preparedness management plan. 22

Automatic Sprinkler System Required for facilities housed in multistory buildings that were constructed after January 1, 2008 and those housed in high rise buildings constructed after January 1., 2008 Annual Inspections Quarterly Inspections Monthly Monitoring 23

Fire Alarm System Annual Inspection Sensitivity Test Smoke Detectors Alarm Panel Pull Stations 24

Portable Fire Extinguishers Annual Inspections Monthly Inspections Six year maintenance Hydrostatic testing 5 12 years interval 25

Fire Drills Have a plan and specific duties for all employees. ALL staff must participate. Shall be conducted quarterly on each shift. Drills are to be held at unexpected times and under varying conditions 26

Corridor Room Doors Doors in sprinklered buildings only required to resist the passage of smoke. Doors must latch securely when closed. Hold open devices that release when the door is pushed or pulled are permitted. Doors can not be blocked open with any thing. 27

Exit Access Corridors and Exit Doors Exit access and exit doors shall be arranged and designed to be clearly recognizable. Means of egress shall be continuously maintained free of all obstructions or impediments at all times. 28

EXITACCESS Exits must terminate directly at a public way or at an exterior exit discharge. Yards, courts, open spaces, or other portions of the exit discharge must be of required width and size to provide all occupants with safe access to a public way. To ensure adequate hard surfaces, CMS requires asphalt or concrete surfaces from exterior exits to public ways.

EXITACCESS Keyed locks, dead bolt locks and multi latching devices create an impediment to egress from individual habitable spaces.

Deficiencies that Should never occurr Oxygen Storage Portable Space Heaters Exit Signs Extension Cords Testing Emergency Lights 33

Maintenance Logs Have all Life Safety concerns together Don t use check marks Give location of equipment tested 35

Managing Fire Risk The written fire response plan describes the specific roles of staff and licensed independent practitioners at and away from a fire s point of origin, including when and how to sound fire alarms, how to contain smoke and fire, how to use a fire extinguisher and how to evacuate to areas of refuge

Fire Drills The hospital conducts fire drills once per shift per quarter in each building defined as a health care occupancy by the Life Safety Code. The hospital conducts quarterly fire drills in each building defined as an ambulatory health care occupancy by the Life Safety Code. The hospital conducts fire drills every 12 months from the date of the last drill in all freestanding buildings classified as business occupancies and in which patients are seen or treated.

Fire System Testing Key Fire System Maintenance Requirements Every 12 months the hospital tests visual and audible fire alarms including speakers Every quarter the hospital tests fire alarm equipment for notifying offsite fire responders. At least quarterly the hospital tests supervisory signal devices. Every 12 months the hospital tests duct detectors, electromechanical releasing devices, heat detectors, manual fire alarm boxes and smoke detectors. Every 6 months the hospital tests valve tamper switches and water-flow devices.

Fire System Testing Key Fire System maintenance Requirements At least monthly, the hospital inspects portable fire extinguishers Every 12 months the hospital performs maintenance on portable fire extinguishers The hospital operates fire and smoke dampers 1 year after installation and then at least every 6 years to verify that they fully close. Every 12 months the hospital tests automatic smokedetection shutdown devices for air-handling equipment

Medical Equipment Maintenance Inspects, tests and maintains all life-support equipment. Inspects, tests and maintains non-life-support equipment identified on the medical equipment inventory. Performs equipment maintenance and chemical and biological testing of water used in hemodialysis.

Fire Code & ABHR Class IB: Flashpoint below 73F and having a boiling point above 100F Isopropyl: Flashpoint 53F and boiling point 183F Maximum individual dispenser: 2.0L Maximum of 10G (37.85L) per smoke compartment The dispenser shall not be installed over or directly adjacent to an ignition source. ABHR dispensers must be mounted no less than 4 feet from each other, measured horizontally

Slide: Courtesy Ron Reynolds