Subject: Notification of Petroleum Dry Cleaning Machine Installation (SUN - 175)

Similar documents
Emis. Unit Description:

COMPLIANCE INSPECTION CHECKLIST. Date: 5/14/2011 Time In: 12:30PM Time Out: 1:00PM

COMPLIANCE INSPECTION CHECKLIST. Date: 12/20/12 Time In: 1:00PM Time Out: 1:30PM

San Joaquin Valley Air Pollution Control District

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs)

Airborne Toxic Control Measure for Emissions of Perchloroethylene from Dry Cleaning Operations

NACT 287 Dry Cleaning

AIR POLLUTION CONTROL REGULATION NO. 23 CONTROL OF PERCHLOROETHYLENE EMISSIONS FROM DRY CLEANING OPERATIONS. Promulgated December 2, 2003

Subpart M National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities

[Docket No. FAA ; Directorate Identifier 2012-NM-176-AD] Airworthiness Directives; DASSAULT AVIATION Airplanes

SOLVENT CLEANING OPERATION EQUIPMENT SUMMARY FORM-44 Page 1 of 7

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Instructions and Resource Manual for the Dry Cleaner Compliance Calendar

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

S 2024 S T A T E O F R H O D E I S L A N D

ORDINANCE O-152. (B) Title. This ordinance shall be known as the City of Saginaw Outdoor and Open Burning Ordinance.

AGENCY OF NATURAL RESOURCES Waterbury, Vermont ENVIRONMENTAL PROTECTION REGULATIONS CHAPTER 5 AIR POLLUTION CONTROL. Subchapter II.

UNOFFICIAL COPY OF HOUSE BILL 1406 A BILL ENTITLED

Append LCCO 10.8 Emissions from Fuel-Burning Equipment

UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923

OHIO UNIVERSITY RADIATION SAFETY REVIEW

Installation & Operation Manual Ice Cream Freezers

U.S. Department East Building, PHH 32 of Transportation. The US Department of Transportation Competent Authority for the United States

UNOFFICIAL COPY OF SENATE BILL 464 A BILL ENTITLED

The New EMC Directive 2004/108/EC

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

APPENDIX 2 NORTHEAST AIR ALLIANCE. SMOKE MANAGEMENT PLAN For Butte, Lassen, Modoc, Plumas, Shasta, Siskiyou, Tehama

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

Creating a New Care Label for Environmentally Friendly Professional Wetcleaning:

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

ANNEXES. to the. Commission Delegated Regulation

TOWN OF BIGGAR OPEN OUTDOOR FIRE BYLAW BYLAW NO A BYLAW TO REGULATE OPEN OUTDOOR FIRES

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

Management of Solvents and Wipes in the Printing Industry

City of Regina Alarm Bylaw

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

L'HOTELLIER

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Standard PRC Transmission Relay Loadability

Miniature Hobby Boiler Inspection and Certification Requirements

CITY OF SURREY BY-LAW NO SURREY SECURITY AND FIRE ALARM BY-LAW,

Ministry Ministère Order Issued Pursuant to s.35(14) of of the de O. Reg. 419/05 Environment l Environnement. Benzene and Climate et de l Action en

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

SCHEDULE 2 - EXHIBIT 1 DATED [ ] NATIONAL GRID ELECTRICITY TRANSMISSION PLC (1) and THE CONNECTION AND USE OF SYSTEM CODE

Append LCCO 10.8 Emissions from Fuel-Burning Equipment

Guidance Document for the Halogenated Solvent Cleaner NESHAP - Forms Only Version

06-96 DEPARTMENT OF ENVIRONMENTAL PROTECTION CONTROL OF EMISSIONS FROM OUTDOOR WOOD BOILERS

1997 Edition. Clearing the Air on Clean Air: Strategies for Perc Drycleaners Compliance Risk Reduction Pollution Prevention

Ministry Ministère Order Issued Pursuant to s.35(14) of of the de O. Reg. 419/05 Environment l Environnement and Climate et de l Action en.

1SPP Notification to Construct

CITY OF VANCOUVER CORPORATE POLICY

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

INDEX 100 GENERAL 101 PURPOSE 102 EXEMPTION, VACUUM CONDITION 103 EXEMPTION, VAPOR PRESSURE

ALABAMA Propane Gas Association

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

a) Establishment of emergency procedures to be followed at the time of an emergency;

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Loss Prevention Standard

COMMISSION DELEGATED REGULATION (EU) /... of

RADIATION CONTROL GUIDE

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD ALARM SYSTEMS

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

APPENDIX 112D. PERCHLOROETHYLENE DRY CLEANING NESHAP (40 CFR 63 Subpart M) CAA SECTION 112 NESHAP

Perchloroethylene in Dry Cleaning

UNIVERSITY OF WASHINGTON MASTER PLAN SEATTLE CAMPUS

The New EMC Directive 2004/108/EC

PARTS CLEANING AND DEGREASING

Brandon Fire and Emergency Services

Study Final Report. Priority Cool Refrigerant Study

EXTRACT FROM MAYOR AND COUNCIL MEETINGS PERTAINING TO FIRE HYDRANTS

2007 ASME Boiler & Pressure Vessel Code 2007 Edition July 1, 2007

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

SPECIFICITIES OF SUPERVISION OF OVERPRESSURIZED EQUIPMENT

Environmental Expenditures. by the U.S. Oil and Natural Gas Industry

U.S. Department East Building, PHH 32 of Transportation. The US Department of Transportation Competent Authority for the United States

Part I Extraction Process Equipment

[Docket No. FAA ; Directorate Identifier 2004-CE-25-AD; Amendment ; AD ]

Westerville, OH Code of Ordinances. CHAPTER 969 Alarm Systems

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. November 3, 2016 PERMIT TO INSTALL 31-02B

Subj: Shipboard Refrigerant Leak Repair and Record Keeping

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

Loss Prevention Standard

Cat 5 Pro Vacuum OPERATOR S MANUAL

DEPARTMENT OF THE ARMY TECHNICAL MANUAL TECHNICAL MANUAL

Water and Waste Department Service des Eaux et des Déchets

Nine Metal Fabrication and Finishing Source Categories 40 Code of Federal Regulations (CFR) Part 63, Subpart XXXXXX (6X NESHAP)

CITY OF POWELL RIVER

Phase 2 Security Response

Chapter ALARM SYSTEMS

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

MANUAL OF PROCEDURE. Keys and Access Control (Standard and Electronic)

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Land Use Amendment in Southwood (Ward 11) at and Elbow Drive SW, LOC

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

NESLAB CB 60/CB 80 Cryobaths. Operation. Product Service Information, Applications Notes, MSDS Forms, .

Chapter 101 OPEN FIRES

Transcription:

SWCAA Southwest Clean Air Agency 11815 NE 99th Street, Suite 1294 Vancouver, WA 98682 (360) 574-3058 www.swcleanair.org August 16, 2018 Eun Yi Imperial Cleaners Shop 470 NE Birch Street Camas, WA 98607-2029 Subject: Notification of Petroleum Dry Cleaning Machine Installation (SUN - 175) Dear Mr. Yi: The Southwest Clean Air Agency (SWCAA) received your Small Unit Notification (SUN) on May 17, 2018 for installation and operation of a new dry cleaning machine at Imperial Cleaners Shop. For administrative and tracking purposes SWCAA has assigned tracking number SUN-175 to this notification. This notification was filed in accordance with SWCAA 400-072 and applies to the installation of one dry cleaning machine. The new machine was identified as: ( 1) InnoClean model AC-400 with a load capacity of 40 pounds. The unit will utilize DF-2000 as a cleaning fluid. SW CAA has completed a review of your notification and the associated support information and has determined that the notification meets the requirements of SWCAA 400-072(2). Once installed, affected equipment must maintain compliance with the requirements of SWCAA 400-072(5)(d) "Petroleum Dry Cleaners". A copy of the relevant SW CAA 400-072 section is attached for your information. Be advised that em1ss1on units installed pursuant to SWCAA 400-072 are subject to source registration and periodic inspection. Registration fees for this equipment will be invoiced consistent with SWCAA 400-100. If you need further assistance or have any questions regarding these matters, please contact me at (360) 574-3058 extension 130. Q Sincerely, ~;{/l{~ Paul T. Mairose Chief Engineer Our Mission is to Preserve and Enhance Air Quality in Southwest Washington @

SWCAA 400-072 Emission Standards for Selected Small Source Categories [Statutory Authority : Chapter 70.94.141 RCW 5/ 18/17, effective 6/18/1 71 Original adoption 09-21 -056 fi led I 0/ 15/09, effective 11 / 15/09, 16-19-009 filed 9/8/ 16, effective I 0/9/16; 17-11-078 filed (5) Source categories. ( d) Petroleum dry cleaners. (i) Applicability. The provisions of this section apply to dry cleaning facilities that use petroleum solvent and have a total manufacturer's rated dryer capacity less than 38 kilograms (84 pounds). The total manufacturers' rated dryer capacity is the sum of the manufacturers' rated dryer capacity for each existing and proposed petroleum solvent dryer at the facility. (ii) Emission limits and standards. (A) VOC emissions from each dry cleaning facility shall not exceed 1.0 ton per year. Emissions shall be calculated using a mass balance approach assuming that all cleaning fluid utilized at the facility is emitted to the ambient air. Documented quantities of cleaning fluid shipped offsite as waste may be deducted from the calculated emissions. (B) Operations which cause or contribute to odors that unreasonably interfere with any other property owner's use and enjoyment of their property shall use recognized good practice and procedures to reduce these odors to a reasonable minimum, consistent with the requirements of SW CAA 400-040( 4). (iii) General requirements. (A) Each dry cleaning facility shall be operated in a business space zoned for commercial activity, located a minimum of 200 feet from the nearest residential structure. (B) Dry cleaning machines shall use DF-2000 cleaning fluid or an equivalent solvent. (C) Solvent or waste containing solvent shall be stored in closed solvent tanks or containers with no perceptible leaks. (D) All cartridge filters shall be drained in their sealed housing or other enclosed container for 24 hours prior to disposal. (E) Perceptible leaks shall be repaired within twenty-four hours unless repair parts must be ordered. If parts must be ordered to repair a leak, the parts shall be ordered within 2 business days of detecting the leak and repair parts shall be installed within 5 business days after receipt. (F) Pollution control devices associated with each piece of dry cleaning equipment shall be operated whenever the equipment served by that control device is in operation. Control devices shall be operated and maintained in accordance with the manufacturer's specifications. (iv) Monitoring and recordkeeping requirements. The information listed below shall be recorded at the specified intervals, and maintained in a readily accessible form for a minimum of 3 years. Each required record shall include the date and the name of the person making the record entry. (A) Each dry cleaning machine shall be visually inspected at least once per week for perceptible leaks. The results of each inspection shall be recorded in an inspection log and maintained on-site. The inspection shall include, but not be limited to the following: (I) Hose connections, unions, couplings and valves;

(v) (vi) (II) Machine door gaskets and seating; (III) Filter gaskets and seating; (IV) Pumps; (V) Solvent tanks and containers; (VI) Water separators; (VII) Distillation units; (VIII) Diverter valves; and (IX) Filter housings. (B) The amount of cleaning fluid (e.g., DF-2000) purchased, used, and disposed of shall be recorded monthly. (C) Upset conditions that cause excess emissions shall be recorded for each occurrence; and (D) All air quality related complaints, including odor complaints, received by the owner or operator and the results of any subsequent investigation or corrective action shall be recorded promptly after each occurrence. Testing requirements. None. Reporting requirements. (A) The owner or operator of an affected emission unit shall provide written notification of initial operation to SW CAA within 10 days of occurrence. (B) All air quality related complaints, including odor complaints, received by the permittee shall be reported to SWCAA within 3 calendar days of receipt. (C) The owner or operator of an affected petroleum dry cleaner shall report the following information to the Agency no later than March 15th for the preceding calendar year: (I) Quantity of cleaning fluid (e.g., DF-2000) consumed; and (II) Air emissions of criteria air pollutants, VOCs, and toxic air po 11 utants (T APs). 2

Summary Information (by SWCAA) for SUN-175 Imperial Cleaners Shop A petroleum solvent dry cleaning machine was installed m October 2017 to replace the perchloroethylene machine. New Unit Information Unit Identification: InnoClean Location: 470 NE Birch Street, Camas, WA 98607 Make/Model: InnoClean / AC-400 Serial Number: IS4038-0096 Built: 2017 Installed: October 2017 Load Capacity: 40 pounds Solvent Capacity: 80 gallons Stack Description: No stack The dry cleaning machine utilizes DF-2000 or a similar fluid as a cleaning solvent. DF-2000 fluid is a hydrotreated aliphatic hydrocarbon manufactured by ExxonMobile Chemical Company. DF- 2000 fluid consists primarily of hydrocarbons in the range of C6 - C13. Several toxic air pollutants are within this hydrocarbon range including hexane, heptane, octane, and nonane, however their concentrations in DF-2000 are expected to be negligible. DF-2000 fluid has a vapor pressure of 0.49 IllinHg at 68 F ( compared to perchloroethylene with a vapor pressure of 18.5 mrnhg at 77 F) AC400 InnoClean

KTE Co., Ltd. 1497-1,SongJeong- Dono. Gangseo- Gu. Busan 618-817, l".orca lei 82-51- 265-0255. Fax 82-51-265-0250 Mode\ AC- 400 Heating Steam Ser,a\ No. Manutactured listed So\vent ti\\ino F\ash point ETL Voltage 3~.200-240VAC.60r1z.25A Electric consumption Load 300/80 I/gal Steam(Operating) 64/147 c/ F Water(Operating) Spinning Max 900 r.p.m Air th ng 8 flash point less than Not to be operated with a solven av, that stated 12 40 Dry Cleaning Machine Emissions. Emissions ofvocs from the dry cleaning machine and process occur from evaporation of residual liquid from garments, leaks, and volatilization during maintenance activities. The amount of VOCs released must be calculated using a material balance methodology assuming that the quantity of VOCs released to the air is the difference between the amount of cleaning fluid purchased, and the amount of cleaning fluid disposed offsite as waste. DF-2000 fluid has a specific gravity of 0.77 at 60 F, therefore it takes approximately 311 gallons of DF-2000 fluid evaporation to equate to 1 ton of VOC emissions. It is estimated that annual emissions will be much less than 1 ton. To account for an up-turn in business and/or a lower solvent mileage in actual practice, SW CAA estimated that potential VOC emissions could be approximately 0.5 tons per year. An emission rate of 0.5 tons ofvoc emission per year is equivalent to 125,000 pounds of clothing cleaned with a solvent mileage of 800 pounds of clothing per gallon of DF-2000 fluid.