30RB C Series Air-Cooled Liquid Chiller

Similar documents
30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30KAV Variable Speed Air-cooled Screw Chiller

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

30RB/RQ 039S-160S Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

30RB /30RQ

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

Carrier India. Snapshots of Carrier India manufacturing facility

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30RB /30RQ

61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30RB /30RQ

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw. Features and advantages. Very economical operation

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

30RB/RQ Modular Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30RB A /30RQ

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

30RB Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features. Quiet operation

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

30RBM/30RBP AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE PRODUCT SELECTION DATA

AQUASNAP JUNIOR 30RHV

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

MISSING 30XB / 30XBP AIR-COOLED FIXED-SPEED SCREW CHILLER PRODUCT SELECTION DATA

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

3 0 H X C A - H P 2

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

30XW Water-Cooled Liquid Chiller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30XAV Variable Speed Air-cooled Screw Chiller. Nominal cooling capacity 327~1385KW

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

.2 Section Waste Management and Disposal.

30HXC Nominal cooling capacity kw

Neosys Product catalogue

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

30XW Water-Cooled Liquid Chiller

30RBS /30RQS Air-Cooled Liquid Chillers, Reversible Air-to-Water Heat Pumps. product selection data

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Product Data. Features/Benefits ComfortLink control

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

Water-cooled chillers with High Speed Centrifugal Compressors

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

HYDRONIC RESIDENTIAL

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

High COP. Water-Cooled Screw Chiller

30KAV VARIABLE-SPEED SCREW LIQUID CHILLER WITH GREENSPEED TM INTELLIGENCE PRODUCT SELECTION DATA

Aquaflair TRAC-TRAF-TRAH

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

Renewables High-Temperature Monobloc Air-t nobloc Air oc Air o t -Wat W er Heat P ater He umps er Heat Pum mps

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Be sustainable while protecting your business

Advance Split

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

SCA 620C AIR COOLED SCREW CHILLER

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

30GTS,GTU. Air-Cooled Reciprocating Liquid Chillers with ComfortLink Controls 50 Hz Nominal Capacities: 50 to 410 Tons 172 to 1354 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

30XW-PZE/30XWHPZE-A WATER-COOLED SCREW CHILLERS WATER-SOURCED SCREW HEAT PUMPS PRODUCT SELECTION DATA

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Galletti Water chillers and heat pumps catalogue

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Transcription:

0RB C Series AirCooled Liquid Chiller

Turn To The Experts Inheriting a rich legacy of innovation including inventing modern airconditioning, Carrier has been a global leader in innovations for Heating Ventilation Air Conditioning (HVAC) and refrigeration solutions. Carrier is a part of UTC Climate, Controls & Security, a unit of United Technologies Corp., a leading provider to the aerospace and building systems industries worldwide. With a broad portfolio of advanced technical patent awards, our global R&D center in Shanghai develops innovative heat, ventilation and airconditioning (HVAC) solutions. In 998, Time magazine named Dr. Carrier oneof its 0 most influential builders and titans of the 0 th century.

Nomenclature 0RB C PT0/6C/4 Options PT00B PT00A PT0 PT0 PT6C PT6D PT6F PT6G PT6H PT6l PT6 PT8A PT4 Blygold PoluAl Golden fin High static pressure fan Protection grilles High pressure dual pump hydronic module Unit without hydronic module Low pressure single pump hydronic module Low pressure dual pump hydronic module Super high pressure single pump hydronic module Super high pressure dual pump hydronic module EMM (Energy Management Module) 7" Touch Pilot TM screen Cu/Al condenser coils Design Series Unit Model 0RB Aircooled scroll chiller Operating Range, 0RB8~C Evaporator water temperature Minimum( ) Maximum( ) Entering water temperature at shutdown 48 Entering water temperature at startup 6.8 40 Entering water temperature during operation 6.8 Leaving water temperature during operation. Condenser air temperature Entering air temperature C 48 0 0 PT 08B PT 08 Minimum( ) Maximum( ) Standard unit 0 48 With winter operation option (PT08) 0 48 With winter operation option (PT08B) 0 48 Note:Evaporator and condenser t = 0. Evaporator leaving water temperature C Standard unit operating range. PT08 or PT08B Winter operation.

Features Developed from Carrier s leading technologies, the AquaSnap Chiller delivers allinone packaged design with leading efficiency and compact footprint, which make it be a premium solution for medium size commercial or industrial projects. Economical operation Industry leading efficiency at full load thanks to: Optimized air management system including improved heat exchanger design and patented Flying bird IV fans. Specifically designed direct expansion evaporator increases heat exchange performance and features higher flexibility to harsh water condition. Increased energy efficiency at part load The refrigerant circuit includes several compressors connected in parallel. At part load, around 99% of the operating time, only the compressors that are absolutely necessary operate. The electronic expansion device (EXV) allows operation at a lower condensing pressure (EER and COP optimization), and dynamic superheat management for better utilization of the evaporator heat exchanger surface. Reduced maintenance costs Maintenancefree scroll compressors. Fast diagnosis of possible incidents and their history via the Touch Pilot control. HFC40A refrigerant is easier to use than other refrigerant blends. Easy and quick installation Integrated builtin hydronic modules: Save efforts on design and installation by integrating all the core components of the hydronic system including centrifugal pumps, water filters, expansion tank, water flow switch, water flow control valve,, etc. Address various customer needs on job site through diversified options of different pressure head and pump quantity (single or dual). Simplified electrical connections A single power supply point without neutral. Main disconnect switch with high trip capacity. Fast commissioning Systematic factory operation test before shipment. Quicktest function for stepbystep verification of the instruments, electrical components and motors. Environmental sound Compact footprint With specifically sized coils and system design, the chiller featuring superior compact footprint that saves valuable installation space is the ideal choice for retrofit projects. The builtin hydronic module brings onestop installation to save significantly save installation space by up to 0% compared to decentralized hydronic system. 0 Ozonefriendly R40A refrigerant Chlorinefree refrigerant of the H depletion potential. Very efficient gives an increas Leaktight refrigerant circuit. Brazed refrigerant connections Reduction of leaks as no capilla are used. Verification of pressure transdu without transferring refrigerant c 0 0 90 70 Carrier Brand A Brand B

Easy management Thanks to new innovative Touch Pilot control platform, Aquasnap chillers offer easy local and remote management: Convenient operation: An intuitive and userfriendly, colored, interface Easy access to the controller box with inclined touch screen mounting to ensure legibility under any lighting conditions Screenshots with concise and clear information in local languages. Complete menu, customized for different users (end user, service personnel and Carrierfactory technicians). Easy and quick service Direct access to the unit s technical drawings and the main service documents. Simple and smart intelligence uses data collection from the constant monitoring of all machine parameters to optimise unit operation. Graphic trending of main operating variables: evaporator entering/leaving temperature, OAT, condensing and evaporating temperature Alarm notification through emails. Excellent remote communication Easy access from any local Ethernetenabled device or intranetnetwork Connectivity to BA system through diverse communication protocals High speed Bacnet IP connectivity Graphic trending Dynamic P&ID Quiet operation Compressors Lownoise scroll compressors with low vibration level. The compressor assembly is installed on an independent chassis and supported by antivibration mountings. Dynamic suction and discharge piping support minimize vibration transmission (Carrier patent). Acoustic compressor enclosure reduces radiated noise emission (option). Condenser section Condenser coils in Vshape with an open angle allows quieter air flow across the coil. Lownoise 4th generation Flying Bird fans (Carrier patent) enjoy quieter operation and never generate intrusive lowfrequency noise. Rigid fan mounting preventing startup noise (Carrier patent). FC group with zero zone ed energy efficiency ratio for increased leaktightness. ry tubes and flare connections ers and temperature sensors harge. Absolute reliability Autoadaptive control Control algorithm prevents excessive compressor cycling Carrier patent Automatic compressor unloading in case of abnormally high condensing pressure. If condenser coil fouling or fan failure occurs, the Aquasnap continues to operate, but at reduced capacity. Exceptional endurance tests Corrosion resistance tests in salt mist in the laboratory. Accelerated ageing test on components that are submitted to continuous operation: compressor piping,fan supports. Transport simulation test in the laboratory on a vibrating table. The test is based on a military standard and equivalent to 4000 km by truck. 4

Touch Pilot TM Control General Features New innovative smart control features: An intuitive and userfriendly, colored, interface Direct access to the unit s technical drawings and the main service documents Screenshots with concise and clear information in local languages Complete menu, customized for different users (end user, service personnel and Carrierfactory technicians) Easy access to the controller box with inclined touch screen mounting to ensure legibility under any lighting conditions Safe operation and unit setting: password protection ensures that unauthorized people cannot modify any advanced parameters Simple and smart intelligence uses data collection from the constant monitoring of all machine parameters to optimise unit operation Night mode Energy management: Internal time schedule clock controls chiller on/off times and operation at a second setpoint The DCT (Data Collection Tool) records the alarms history to simplify and facilitate service operations Remote Management (Standard) Units with Touch Pilot control can be easily accessed from the internet, using a PC with an Ethernet connection. This makes remote control quick and easy and offers significant advantages for service operations Aquaforce is equipped with an RS48 serial port that offers multiple remote control, monitoring and diagnostic possibilities. When networked with other Carrier equipment through the CCN (Carrier Comfort Network proprietary protocol), all components form a HVAC system fullyintegrated and balanced through one of the Carrier s network system products, like the Chiller System Manager or the Plant System Manager (optional). The 0RB also communicates with other building management systems via optional communication gateways. Dual setpoint management: Through a dedicated contact is possible to activate a second setpoint (example: unoccupied mode) Demand limit setting: To limit the maximum chiller capacity to a predefined value Water pump control: These outputs control the contactors of one/two evaporator water pumps Water pumps on reversal (only with options 6C/6G):These contacts are used to detect a water pump operation fault and automatically change over to the other pump Operation visualization: Indication if the unit is operating or if it s in standby (no cooling load) Alarm visualization Remote Management (EMM option) The Energy Management Module (EMM) offers extended remote control possibilities: Room temperature: Permits setpoint reset based on the building indoor air temperature (if Carrier thermostat are installed) Setpoint reset: Ensures reset of the cooling setpoint based on a 40 ma or 00 V signal Demand limit: Permits limitation of the maximum chiller power or current based on 00 V signal Demand limit and : Closing of these contacts limits the maximum chiller power or current to two predefined values User safety: This contact can be used for any customer safety loop; opening the contact generates a specific alarm Time schedule override: Closing of this contact cancels the time schedule effects Out of service: This signal indicates that the chiller is completely out of service Chiller capacity: This analogue output (00 V) gives an immediate indication of the chiller capacity Alert indication: This voltfree contact indicates the necessity to carry out a maintenance operation or the presence of a minor fault Compressors running status : Set of outputs (as many as the compressors number) indicating which compressors are running The following commands/visualizations are possible from remote connection: Start/Stop of the machine

Technical Specification Performance data 0RB 8CPT4 0CPT4 CPT4 6CPT4 CPT4 4CPT4 40CPT4 46CPT4 CPT4 Nominal cooling capacity* kw 80 06 40 7 4 484 46 Compressor power input kw 49 60 66 8 9 06 7 47 67 EER kw kw.9.09.7.06.7.06.0.0.0 Operating weight Standard unit** kg 9 0 0 949 999 80 8 900 Unit without hydronic module kg 906 970 07 0 807 86 97 608 688 Refrigerant Circuit A kg 0.0.0.0.0.0.0.0.0 4.0 Circuit B kg.0.0.0.0 0.0.0.0 44.0 44.0 Compressor Hermetic scroll compressors Circuit A 4 Circuit B 4 4 Number of capacity stages 4 4 6 7 8 Minimum capacity % % % % % 8% 0% 7% 4% % Control Condensers Fans Touch Pilot TM controls Gr Axial Flying Bird IV with rotating shroud Quantity 4 4 4 6 7 8 T I/s 4 806 806 806 69 69 708 97 6 Speed rpm 90 Evaporator Direct expansion shellandtube Water volume I 0 0 0 0 m /h 0.9. 4. 46.8. 60. 7. 8.9 9.7 Unit internal water pressure drop kpa 6 9 7 0 4 64 Max. waterside operating pressure without hydronic module kpa 000 with hydronic module kpa 400 Hydronic module Centrifugal pump,victaulic scr r,safety valve,expansion tank,air vent, flow switch, water flow control valve, etc. Water pressure external to chiller Standard unit** kpa 90 8 8 60 97 8 76 9 96 Unit with low pressure pump kpa 0 99 86 09 8 0 74 Unit with super high pressure pump kpa 9 8 66 9 9 88 6 46 64 Expansion tank I 0 0 0 0 80 80 80 80 80 Water connections Diameter (with hydronic module) Diameter (without hydronic module) Electrical data Main power supply Control power supply Nominal unit operating current draw, circuit A+B Maximum operating current draw, circuit A+B Maximum startup current, circuit A+B DN 00 00 00 00 00 00 00 DN 00 00 00 00 00 00 00 0 0 400VPh0Hz Main power supply by builtin transformer A 0 0 4 79 9 7 A 7 96 8 4 9 48 9 A 0 8 6 46 48 47 78 6 Total fan power input kw.6 7. 7. 7. 8.6 8.6 0..6. Pump power input (standard unit**) kw.6.9..7 4.9.0 6.0 6. 0. * Nominal cooling mode evaporator entering/leaving water temperature /7, outside air temperature ; Evaporator fouling factor 0.08m K/kW. ** Standard unit is equipped with high speed single pump hydronic module. 6

Options & accessories Options No. Description Advantages Available for Improved corrosion resistance, Blygold PoluAL 00B Coil with factoryapplied Blygold PoluAL treatment recommended for heavy marine and industrial environments Golden Fin 00A Fin made of pretreated aluminium (polyurethane and epoxy) Improved corrosion resistance, recommended for light marine environments High static pressure fan 0 0rpm to provide 0Pa static pressure for indoor unit installation with discharge ducts Available for ducted condenser air discharge, optimized condensing temperature control Protection grilles 0 Metallic grilles on the four unit aces Better chiller protection and aesthetics Better chiller protection and aesthetics Winter operation (0ºC) 08 Fan speed control by frequency inverter Stable operation between 0 and 0 outdoor air temperature Winter operation (0ºC) 08B Twospeed ontrol by frequeny inerter Stabe operation between o 0 and 0 outdoor air temperature Antifreezing evaporator electrical heater 04 Electrical heater equipped on evaporator Prevent evaporator to be freezed under winter seasons Lead lag control 08 To allow master/slave operation of two chillers connectted in parallel or series Optimised operation of two chillers connected in parrallel with operating time balancing Evaporator Aluminium caldding 088 Evaporator with aluminium cladding Evaporator with aluminium cladding Suction & discharge valve 09A Shut off valves on the suction and dischrage pipiping of compressor Simplifed maintenance Discharge valve 09A Shut off valves on the dischrage pipiping of compressor Simplifed maintenance High pressure dual pump hydronic module (with electrical heater) 6C Provide integrated hydronic module with high pressure dual pump Easy and quick installation, operating safety Unit without hydronic module or electrical heater 6D Unequip high pressure singl pump hydronic module in standard unit Easy and quick installation, operating safety Low pressure single pump hydronic module (with electrical heater) 6F Provide integrated hydronic module with low pressure single pump Easy and quick installation, operating safety 7

Options & accessories Options No. Description Advantages Use Low pressure dual pump hydronic module (with electrical heater) 6G Provide integrated hydronic module with low pressure dual pump Easy and quick installation, operating safety Super high pressure single pump hydronic module (with electrical heater) 6H Provide integrated hydronic module with super high pressure single pump Easy and quick installation, operating safety Super high pressure dual pump hydronic module (with electrical heater) 6I Provide integrated hydronic module with super high pressure dual pump Easy and quick installation, operating safety CCN to JBus gateway 48B Twodirectional communication board with JBus protocol Easy connection by communication bus to building management system CCN to Bacnet gateway 48C Twodirectional communication board with LonTalk protocol Easy connection by communication bus to building management system CCN to LonTalk gateway 48D Twodirectional communication board with LonTalk protocol Easy connection by communication bus to building management system Bacnet over IP gateway 49 Twodirectional highspeed communication using Bacnet protocol over Ethernet network (IP) Easy connection by communication bus to building management system Energy Management Module (EMM) 6 See control manual Ease of unit operation and energy saving management 7" Touch Pilot TM screen 8A 7" colorful touch screen display Better operation experience Cu/Al condenser coils 4 Coils made of copper tube with aluminium fin Australian compliance A Compliance with Australian regulation Enhanced hydrophilic character Blue fin 0 Hydrophilic Aluminium coil and better aesthetics 8

Dimensions/Clearances 0RB8C~6C 97 G Z Power X 40 80 Y 00 00 68 00 00 40 G View DN00 DN00 Unit without hydronic module 00 00 68 0 00 00 DN00 G View DN00 unit model 0RB8C X 7 Y Z 860 Required clearances for maintenance and air flow Control box Water inlet Water outlet 0RB0C 0RBC 0RB6C 48 9 4 09 0 90 844 847 Safety valve Center gravity Power supply connection Air outlet do not obstruct *Please contact local Carrier operation for other integrated hydronic module options. 9

Dimensions/Clearances 97 0RBC~40C Z G X A 604 Y Power Standard unit with high pressure single pump hydronic module* 00 700 DN00 00 00 68 6 G View 89 DN00 PT6D (unit without hydronic module) 00 00 DN00 00 68 00 6 09 G View unit model X Y Z A 0RBC 77 9 88 868 0RB4C 77 90 848 868 0RB40C 87 8 069 DN00 Required clearances for maintenance and air flow Safety valve Water outlet Center gravity Power supply connection Water inlet Air outlet do not obstruct *Please contact local Carrier operation for other integrated hydronic module options. 0

Dimensions/Clearances 0RB46C~C 97 G Z X 4798 Power 069 Y 00 00 9 7 00 PT6D (unit without hydronic module) 00 68 68 00 00 G View DN00 DN00 00 00 9 7 G View DN00 DN00 unit model 0RB46C 0RBC X 7 400 Y 48 0 Z 99 980 Required clearances for maintenance and air flow Safety valve Center gravity Water inlet Water outlet Power supply connection Air outlet do not obstruct *Please contact local Carrier operation for other integrated hydronic module options.

Multiple Chillers Installation 000 000 00 000 000 00 00 00 00 Note: If the height of wall exceeds m, please contact local Carrier Sales & Service Corporation. Weight Distribution E C D E D C F Square hole 00 x 00 P P4 P P P6 0 0 A B P P A B P P P 0 0RB8C40C 0RB46CC Section FF Model Dimension Weight distribution (kg) A B C D E F P P P P4 P P6 Operating weight (kg) 0RB8CPT4 9 88 496 446 08 478 9 4 0RB0CPT4 0RBCPT4 0RB6CPT4 0RBCPT4 0RB4CPT4 0RB40CPT4 9 9 9 9 9 9 88 88 88 8 8 8 496 496 496 690 690 690 446 446 446 446 446 446 4 60 60 88 8 8 469 486 4 68 697 677 64 6 664 787 800 90 68 0 69 670 7 9 0 0 949 999 80 0RB46CPT4 9 4776 94 446 94 80 47 946 7 6 486 8 0RBCPT4 9 4776 94 446 94 9 484 96 740 6 496 900

Hydronic Connections Standard unit with integrated high pressure single pump hydronic module 8 9 ( 8 7 0 6 7 6 4 9 0 9 7 6 6 9 7 4 8 7 8 4 Legend: Components of the unit and hydronic module. Installation components. Victaulic screen filter. Expansion tank. Safety valve 4. Water pump. Shutoff valve 6. Pressure gauge 7. Air vent 8. Drain valve 9. Water flow control valve 0. Shellandtube heat exchanger. Evaporator heater. Hydronic module heater. Air vent (evaporator) 4. Water purge (evaporator). Flexible connections 6. Electronic flow switch 7. Water temperature sensor 8. Air vent 9. Flexible connections 0. Check valve. Shutoff valve. Water charge valve. Antivibration pad 4. Water pump support. Evaporator water inlet 6. Evaporator water outlet 7. Hydronic module water inlet 8. Hydronic module water outlet

Heat Exchanger Water Pressure Drop 00 90 80 70 60 0 40 0 Water pressure drop, kpa 0 0 9 8 7 6 4 0RB8C/0C/C/6C 0RBC/4C/40C 0RB46C/C 4 6 7 8 9 0 0 0 40 0 60 70 80 90 00 Water flow rate,l/s Available Static Pressure High pressure pump hydronic module 400 External water pressure, kpa 0 00 0 00 6 0 4 00 0 0 0 0 0 0 Water flow rate, l/s 0RB8C/0C 0RBC/6C 0RBC/4C 4 0RB40C 0RB46C 6 0RBC Low pressure pump hydronic module 0 External water pressure, kpa 00 0 00 0 4 0 0 0 0 0 4 0RB8C/0C 0RBC/6C 0RBC 0RB4C/40C 0RB46C/C Water flow rate, l/s Super high pressure pump hydronic module External water pressure, kpa 400 0 00 0 00 0 00 0 0 0 0 0 0 4 4 0RB8C/0C/C 0RB6C 0RB/C/4C/40C 0RB46C 0RBC Water flow rate, l/s 4

Minimum Water Loop Volume For better control of leaving water temperature, the water loop minimum capacity is given by the formula: Capacity = CAP (kw) N Liters Application Normal air conditioning Process cooling Model 0RB 0RB N. 6. Where Cap is the nominal system cooling capacity (kw) at the nominal operating conditions of the installation. This volume is necessary for stable operation and accurate temperature control. It is often necessary to add a buffer water tank to the circuit in order to achieve the required volume. The tank must be internally baffled in order to ensure proper mixing of the liquid (water or brine).refer to the examples below. Bad Good Bad Good Field Control Wiring (with hydronic module).mm²max 4VAC 0mA Remote ON/OFF swith Set point switch Demand limit switch (Jumped as default) 6 66 6 64 DI0 +C DI0 +C DI0 +C DI04 +C A.mm²MAX A MAX 4VAC 48VDC MAX 80mA MIN 0V MIN Alarm Running 80mA MIN A MAX 80mA MIN A MAX 0 7 8 J J DO0 DO06.mm²MAX 4VAC 0mA User interlock switch (Jumped as default) 4 J DI0 +C A.mm²MAX CCN connector Ethernet connector GND + CCN Port 0 X Ethernet X A

The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_0RB_E70_04 CAT_0RB_E0_0 Jan, 07