0RB C Series AirCooled Liquid Chiller
Turn To The Experts Inheriting a rich legacy of innovation including inventing modern airconditioning, Carrier has been a global leader in innovations for Heating Ventilation Air Conditioning (HVAC) and refrigeration solutions. Carrier is a part of UTC Climate, Controls & Security, a unit of United Technologies Corp., a leading provider to the aerospace and building systems industries worldwide. With a broad portfolio of advanced technical patent awards, our global R&D center in Shanghai develops innovative heat, ventilation and airconditioning (HVAC) solutions. In 998, Time magazine named Dr. Carrier oneof its 0 most influential builders and titans of the 0 th century.
Nomenclature 0RB C PT0/6C/4 Options PT00B PT00A PT0 PT0 PT6C PT6D PT6F PT6G PT6H PT6l PT6 PT8A PT4 Blygold PoluAl Golden fin High static pressure fan Protection grilles High pressure dual pump hydronic module Unit without hydronic module Low pressure single pump hydronic module Low pressure dual pump hydronic module Super high pressure single pump hydronic module Super high pressure dual pump hydronic module EMM (Energy Management Module) 7" Touch Pilot TM screen Cu/Al condenser coils Design Series Unit Model 0RB Aircooled scroll chiller Operating Range, 0RB8~C Evaporator water temperature Minimum( ) Maximum( ) Entering water temperature at shutdown 48 Entering water temperature at startup 6.8 40 Entering water temperature during operation 6.8 Leaving water temperature during operation. Condenser air temperature Entering air temperature C 48 0 0 PT 08B PT 08 Minimum( ) Maximum( ) Standard unit 0 48 With winter operation option (PT08) 0 48 With winter operation option (PT08B) 0 48 Note:Evaporator and condenser t = 0. Evaporator leaving water temperature C Standard unit operating range. PT08 or PT08B Winter operation.
Features Developed from Carrier s leading technologies, the AquaSnap Chiller delivers allinone packaged design with leading efficiency and compact footprint, which make it be a premium solution for medium size commercial or industrial projects. Economical operation Industry leading efficiency at full load thanks to: Optimized air management system including improved heat exchanger design and patented Flying bird IV fans. Specifically designed direct expansion evaporator increases heat exchange performance and features higher flexibility to harsh water condition. Increased energy efficiency at part load The refrigerant circuit includes several compressors connected in parallel. At part load, around 99% of the operating time, only the compressors that are absolutely necessary operate. The electronic expansion device (EXV) allows operation at a lower condensing pressure (EER and COP optimization), and dynamic superheat management for better utilization of the evaporator heat exchanger surface. Reduced maintenance costs Maintenancefree scroll compressors. Fast diagnosis of possible incidents and their history via the Touch Pilot control. HFC40A refrigerant is easier to use than other refrigerant blends. Easy and quick installation Integrated builtin hydronic modules: Save efforts on design and installation by integrating all the core components of the hydronic system including centrifugal pumps, water filters, expansion tank, water flow switch, water flow control valve,, etc. Address various customer needs on job site through diversified options of different pressure head and pump quantity (single or dual). Simplified electrical connections A single power supply point without neutral. Main disconnect switch with high trip capacity. Fast commissioning Systematic factory operation test before shipment. Quicktest function for stepbystep verification of the instruments, electrical components and motors. Environmental sound Compact footprint With specifically sized coils and system design, the chiller featuring superior compact footprint that saves valuable installation space is the ideal choice for retrofit projects. The builtin hydronic module brings onestop installation to save significantly save installation space by up to 0% compared to decentralized hydronic system. 0 Ozonefriendly R40A refrigerant Chlorinefree refrigerant of the H depletion potential. Very efficient gives an increas Leaktight refrigerant circuit. Brazed refrigerant connections Reduction of leaks as no capilla are used. Verification of pressure transdu without transferring refrigerant c 0 0 90 70 Carrier Brand A Brand B
Easy management Thanks to new innovative Touch Pilot control platform, Aquasnap chillers offer easy local and remote management: Convenient operation: An intuitive and userfriendly, colored, interface Easy access to the controller box with inclined touch screen mounting to ensure legibility under any lighting conditions Screenshots with concise and clear information in local languages. Complete menu, customized for different users (end user, service personnel and Carrierfactory technicians). Easy and quick service Direct access to the unit s technical drawings and the main service documents. Simple and smart intelligence uses data collection from the constant monitoring of all machine parameters to optimise unit operation. Graphic trending of main operating variables: evaporator entering/leaving temperature, OAT, condensing and evaporating temperature Alarm notification through emails. Excellent remote communication Easy access from any local Ethernetenabled device or intranetnetwork Connectivity to BA system through diverse communication protocals High speed Bacnet IP connectivity Graphic trending Dynamic P&ID Quiet operation Compressors Lownoise scroll compressors with low vibration level. The compressor assembly is installed on an independent chassis and supported by antivibration mountings. Dynamic suction and discharge piping support minimize vibration transmission (Carrier patent). Acoustic compressor enclosure reduces radiated noise emission (option). Condenser section Condenser coils in Vshape with an open angle allows quieter air flow across the coil. Lownoise 4th generation Flying Bird fans (Carrier patent) enjoy quieter operation and never generate intrusive lowfrequency noise. Rigid fan mounting preventing startup noise (Carrier patent). FC group with zero zone ed energy efficiency ratio for increased leaktightness. ry tubes and flare connections ers and temperature sensors harge. Absolute reliability Autoadaptive control Control algorithm prevents excessive compressor cycling Carrier patent Automatic compressor unloading in case of abnormally high condensing pressure. If condenser coil fouling or fan failure occurs, the Aquasnap continues to operate, but at reduced capacity. Exceptional endurance tests Corrosion resistance tests in salt mist in the laboratory. Accelerated ageing test on components that are submitted to continuous operation: compressor piping,fan supports. Transport simulation test in the laboratory on a vibrating table. The test is based on a military standard and equivalent to 4000 km by truck. 4
Touch Pilot TM Control General Features New innovative smart control features: An intuitive and userfriendly, colored, interface Direct access to the unit s technical drawings and the main service documents Screenshots with concise and clear information in local languages Complete menu, customized for different users (end user, service personnel and Carrierfactory technicians) Easy access to the controller box with inclined touch screen mounting to ensure legibility under any lighting conditions Safe operation and unit setting: password protection ensures that unauthorized people cannot modify any advanced parameters Simple and smart intelligence uses data collection from the constant monitoring of all machine parameters to optimise unit operation Night mode Energy management: Internal time schedule clock controls chiller on/off times and operation at a second setpoint The DCT (Data Collection Tool) records the alarms history to simplify and facilitate service operations Remote Management (Standard) Units with Touch Pilot control can be easily accessed from the internet, using a PC with an Ethernet connection. This makes remote control quick and easy and offers significant advantages for service operations Aquaforce is equipped with an RS48 serial port that offers multiple remote control, monitoring and diagnostic possibilities. When networked with other Carrier equipment through the CCN (Carrier Comfort Network proprietary protocol), all components form a HVAC system fullyintegrated and balanced through one of the Carrier s network system products, like the Chiller System Manager or the Plant System Manager (optional). The 0RB also communicates with other building management systems via optional communication gateways. Dual setpoint management: Through a dedicated contact is possible to activate a second setpoint (example: unoccupied mode) Demand limit setting: To limit the maximum chiller capacity to a predefined value Water pump control: These outputs control the contactors of one/two evaporator water pumps Water pumps on reversal (only with options 6C/6G):These contacts are used to detect a water pump operation fault and automatically change over to the other pump Operation visualization: Indication if the unit is operating or if it s in standby (no cooling load) Alarm visualization Remote Management (EMM option) The Energy Management Module (EMM) offers extended remote control possibilities: Room temperature: Permits setpoint reset based on the building indoor air temperature (if Carrier thermostat are installed) Setpoint reset: Ensures reset of the cooling setpoint based on a 40 ma or 00 V signal Demand limit: Permits limitation of the maximum chiller power or current based on 00 V signal Demand limit and : Closing of these contacts limits the maximum chiller power or current to two predefined values User safety: This contact can be used for any customer safety loop; opening the contact generates a specific alarm Time schedule override: Closing of this contact cancels the time schedule effects Out of service: This signal indicates that the chiller is completely out of service Chiller capacity: This analogue output (00 V) gives an immediate indication of the chiller capacity Alert indication: This voltfree contact indicates the necessity to carry out a maintenance operation or the presence of a minor fault Compressors running status : Set of outputs (as many as the compressors number) indicating which compressors are running The following commands/visualizations are possible from remote connection: Start/Stop of the machine
Technical Specification Performance data 0RB 8CPT4 0CPT4 CPT4 6CPT4 CPT4 4CPT4 40CPT4 46CPT4 CPT4 Nominal cooling capacity* kw 80 06 40 7 4 484 46 Compressor power input kw 49 60 66 8 9 06 7 47 67 EER kw kw.9.09.7.06.7.06.0.0.0 Operating weight Standard unit** kg 9 0 0 949 999 80 8 900 Unit without hydronic module kg 906 970 07 0 807 86 97 608 688 Refrigerant Circuit A kg 0.0.0.0.0.0.0.0.0 4.0 Circuit B kg.0.0.0.0 0.0.0.0 44.0 44.0 Compressor Hermetic scroll compressors Circuit A 4 Circuit B 4 4 Number of capacity stages 4 4 6 7 8 Minimum capacity % % % % % 8% 0% 7% 4% % Control Condensers Fans Touch Pilot TM controls Gr Axial Flying Bird IV with rotating shroud Quantity 4 4 4 6 7 8 T I/s 4 806 806 806 69 69 708 97 6 Speed rpm 90 Evaporator Direct expansion shellandtube Water volume I 0 0 0 0 m /h 0.9. 4. 46.8. 60. 7. 8.9 9.7 Unit internal water pressure drop kpa 6 9 7 0 4 64 Max. waterside operating pressure without hydronic module kpa 000 with hydronic module kpa 400 Hydronic module Centrifugal pump,victaulic scr r,safety valve,expansion tank,air vent, flow switch, water flow control valve, etc. Water pressure external to chiller Standard unit** kpa 90 8 8 60 97 8 76 9 96 Unit with low pressure pump kpa 0 99 86 09 8 0 74 Unit with super high pressure pump kpa 9 8 66 9 9 88 6 46 64 Expansion tank I 0 0 0 0 80 80 80 80 80 Water connections Diameter (with hydronic module) Diameter (without hydronic module) Electrical data Main power supply Control power supply Nominal unit operating current draw, circuit A+B Maximum operating current draw, circuit A+B Maximum startup current, circuit A+B DN 00 00 00 00 00 00 00 DN 00 00 00 00 00 00 00 0 0 400VPh0Hz Main power supply by builtin transformer A 0 0 4 79 9 7 A 7 96 8 4 9 48 9 A 0 8 6 46 48 47 78 6 Total fan power input kw.6 7. 7. 7. 8.6 8.6 0..6. Pump power input (standard unit**) kw.6.9..7 4.9.0 6.0 6. 0. * Nominal cooling mode evaporator entering/leaving water temperature /7, outside air temperature ; Evaporator fouling factor 0.08m K/kW. ** Standard unit is equipped with high speed single pump hydronic module. 6
Options & accessories Options No. Description Advantages Available for Improved corrosion resistance, Blygold PoluAL 00B Coil with factoryapplied Blygold PoluAL treatment recommended for heavy marine and industrial environments Golden Fin 00A Fin made of pretreated aluminium (polyurethane and epoxy) Improved corrosion resistance, recommended for light marine environments High static pressure fan 0 0rpm to provide 0Pa static pressure for indoor unit installation with discharge ducts Available for ducted condenser air discharge, optimized condensing temperature control Protection grilles 0 Metallic grilles on the four unit aces Better chiller protection and aesthetics Better chiller protection and aesthetics Winter operation (0ºC) 08 Fan speed control by frequency inverter Stable operation between 0 and 0 outdoor air temperature Winter operation (0ºC) 08B Twospeed ontrol by frequeny inerter Stabe operation between o 0 and 0 outdoor air temperature Antifreezing evaporator electrical heater 04 Electrical heater equipped on evaporator Prevent evaporator to be freezed under winter seasons Lead lag control 08 To allow master/slave operation of two chillers connectted in parallel or series Optimised operation of two chillers connected in parrallel with operating time balancing Evaporator Aluminium caldding 088 Evaporator with aluminium cladding Evaporator with aluminium cladding Suction & discharge valve 09A Shut off valves on the suction and dischrage pipiping of compressor Simplifed maintenance Discharge valve 09A Shut off valves on the dischrage pipiping of compressor Simplifed maintenance High pressure dual pump hydronic module (with electrical heater) 6C Provide integrated hydronic module with high pressure dual pump Easy and quick installation, operating safety Unit without hydronic module or electrical heater 6D Unequip high pressure singl pump hydronic module in standard unit Easy and quick installation, operating safety Low pressure single pump hydronic module (with electrical heater) 6F Provide integrated hydronic module with low pressure single pump Easy and quick installation, operating safety 7
Options & accessories Options No. Description Advantages Use Low pressure dual pump hydronic module (with electrical heater) 6G Provide integrated hydronic module with low pressure dual pump Easy and quick installation, operating safety Super high pressure single pump hydronic module (with electrical heater) 6H Provide integrated hydronic module with super high pressure single pump Easy and quick installation, operating safety Super high pressure dual pump hydronic module (with electrical heater) 6I Provide integrated hydronic module with super high pressure dual pump Easy and quick installation, operating safety CCN to JBus gateway 48B Twodirectional communication board with JBus protocol Easy connection by communication bus to building management system CCN to Bacnet gateway 48C Twodirectional communication board with LonTalk protocol Easy connection by communication bus to building management system CCN to LonTalk gateway 48D Twodirectional communication board with LonTalk protocol Easy connection by communication bus to building management system Bacnet over IP gateway 49 Twodirectional highspeed communication using Bacnet protocol over Ethernet network (IP) Easy connection by communication bus to building management system Energy Management Module (EMM) 6 See control manual Ease of unit operation and energy saving management 7" Touch Pilot TM screen 8A 7" colorful touch screen display Better operation experience Cu/Al condenser coils 4 Coils made of copper tube with aluminium fin Australian compliance A Compliance with Australian regulation Enhanced hydrophilic character Blue fin 0 Hydrophilic Aluminium coil and better aesthetics 8
Dimensions/Clearances 0RB8C~6C 97 G Z Power X 40 80 Y 00 00 68 00 00 40 G View DN00 DN00 Unit without hydronic module 00 00 68 0 00 00 DN00 G View DN00 unit model 0RB8C X 7 Y Z 860 Required clearances for maintenance and air flow Control box Water inlet Water outlet 0RB0C 0RBC 0RB6C 48 9 4 09 0 90 844 847 Safety valve Center gravity Power supply connection Air outlet do not obstruct *Please contact local Carrier operation for other integrated hydronic module options. 9
Dimensions/Clearances 97 0RBC~40C Z G X A 604 Y Power Standard unit with high pressure single pump hydronic module* 00 700 DN00 00 00 68 6 G View 89 DN00 PT6D (unit without hydronic module) 00 00 DN00 00 68 00 6 09 G View unit model X Y Z A 0RBC 77 9 88 868 0RB4C 77 90 848 868 0RB40C 87 8 069 DN00 Required clearances for maintenance and air flow Safety valve Water outlet Center gravity Power supply connection Water inlet Air outlet do not obstruct *Please contact local Carrier operation for other integrated hydronic module options. 0
Dimensions/Clearances 0RB46C~C 97 G Z X 4798 Power 069 Y 00 00 9 7 00 PT6D (unit without hydronic module) 00 68 68 00 00 G View DN00 DN00 00 00 9 7 G View DN00 DN00 unit model 0RB46C 0RBC X 7 400 Y 48 0 Z 99 980 Required clearances for maintenance and air flow Safety valve Center gravity Water inlet Water outlet Power supply connection Air outlet do not obstruct *Please contact local Carrier operation for other integrated hydronic module options.
Multiple Chillers Installation 000 000 00 000 000 00 00 00 00 Note: If the height of wall exceeds m, please contact local Carrier Sales & Service Corporation. Weight Distribution E C D E D C F Square hole 00 x 00 P P4 P P P6 0 0 A B P P A B P P P 0 0RB8C40C 0RB46CC Section FF Model Dimension Weight distribution (kg) A B C D E F P P P P4 P P6 Operating weight (kg) 0RB8CPT4 9 88 496 446 08 478 9 4 0RB0CPT4 0RBCPT4 0RB6CPT4 0RBCPT4 0RB4CPT4 0RB40CPT4 9 9 9 9 9 9 88 88 88 8 8 8 496 496 496 690 690 690 446 446 446 446 446 446 4 60 60 88 8 8 469 486 4 68 697 677 64 6 664 787 800 90 68 0 69 670 7 9 0 0 949 999 80 0RB46CPT4 9 4776 94 446 94 80 47 946 7 6 486 8 0RBCPT4 9 4776 94 446 94 9 484 96 740 6 496 900
Hydronic Connections Standard unit with integrated high pressure single pump hydronic module 8 9 ( 8 7 0 6 7 6 4 9 0 9 7 6 6 9 7 4 8 7 8 4 Legend: Components of the unit and hydronic module. Installation components. Victaulic screen filter. Expansion tank. Safety valve 4. Water pump. Shutoff valve 6. Pressure gauge 7. Air vent 8. Drain valve 9. Water flow control valve 0. Shellandtube heat exchanger. Evaporator heater. Hydronic module heater. Air vent (evaporator) 4. Water purge (evaporator). Flexible connections 6. Electronic flow switch 7. Water temperature sensor 8. Air vent 9. Flexible connections 0. Check valve. Shutoff valve. Water charge valve. Antivibration pad 4. Water pump support. Evaporator water inlet 6. Evaporator water outlet 7. Hydronic module water inlet 8. Hydronic module water outlet
Heat Exchanger Water Pressure Drop 00 90 80 70 60 0 40 0 Water pressure drop, kpa 0 0 9 8 7 6 4 0RB8C/0C/C/6C 0RBC/4C/40C 0RB46C/C 4 6 7 8 9 0 0 0 40 0 60 70 80 90 00 Water flow rate,l/s Available Static Pressure High pressure pump hydronic module 400 External water pressure, kpa 0 00 0 00 6 0 4 00 0 0 0 0 0 0 Water flow rate, l/s 0RB8C/0C 0RBC/6C 0RBC/4C 4 0RB40C 0RB46C 6 0RBC Low pressure pump hydronic module 0 External water pressure, kpa 00 0 00 0 4 0 0 0 0 0 4 0RB8C/0C 0RBC/6C 0RBC 0RB4C/40C 0RB46C/C Water flow rate, l/s Super high pressure pump hydronic module External water pressure, kpa 400 0 00 0 00 0 00 0 0 0 0 0 0 4 4 0RB8C/0C/C 0RB6C 0RB/C/4C/40C 0RB46C 0RBC Water flow rate, l/s 4
Minimum Water Loop Volume For better control of leaving water temperature, the water loop minimum capacity is given by the formula: Capacity = CAP (kw) N Liters Application Normal air conditioning Process cooling Model 0RB 0RB N. 6. Where Cap is the nominal system cooling capacity (kw) at the nominal operating conditions of the installation. This volume is necessary for stable operation and accurate temperature control. It is often necessary to add a buffer water tank to the circuit in order to achieve the required volume. The tank must be internally baffled in order to ensure proper mixing of the liquid (water or brine).refer to the examples below. Bad Good Bad Good Field Control Wiring (with hydronic module).mm²max 4VAC 0mA Remote ON/OFF swith Set point switch Demand limit switch (Jumped as default) 6 66 6 64 DI0 +C DI0 +C DI0 +C DI04 +C A.mm²MAX A MAX 4VAC 48VDC MAX 80mA MIN 0V MIN Alarm Running 80mA MIN A MAX 80mA MIN A MAX 0 7 8 J J DO0 DO06.mm²MAX 4VAC 0mA User interlock switch (Jumped as default) 4 J DI0 +C A.mm²MAX CCN connector Ethernet connector GND + CCN Port 0 X Ethernet X A
The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_0RB_E70_04 CAT_0RB_E0_0 Jan, 07