INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

Similar documents
INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Air-cooled modular Chiller. Nick Technical Engineer

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Air Conditioning System


Conditioning your ambient, maximising your comfort.

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Do you want a versatile solution

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

1

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Product Line Introduction. Karl Zhang Technical support engineer

Increase your flexibility.

H4T R410A. refrigerant

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Air Cooled Scroll Chiller

The ultimate fresh air solution.

MODULAR CHILLER. R410a R22

VZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology

Water-cooled chillers with High Speed Centrifugal Compressors

DAIKIN Air Handling Unit Modular

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

recooler HP EQKR HEAT PUMP

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Air Conditioning. Technical Data EEDEN AZQS-BV1

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

ERACS.C-N Higher efficiency air-cooled screw pump

water-cooled CHILLERS

LG Electronics AE Company, Commercial Air Conditioning

Galletti Water chillers and heat pumps catalogue

ARV.

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

LG Electronics AE Company, Commercial Air Conditioning

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Modular Air Cooled Scroll Chillers

DAIKIN Modular Inverter Air Cooled Chiller

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

LG VRF Systems. Air Conditioning Technologies

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Modular Air-cooled Chillers

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Prices and technical information for Applied Systems. Pricelist Applied Systems

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

Integrated VarIable refrigerant flow ahu/pau (r410a)

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Advance Split

HEATING HEA TING

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

DC Inverter Smart VRF Products(R410A)

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

2018 I LG HVAC SOLUTION. LG Electronics Magyar Kft. Distributed by

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

30RB /30RQ

LZT High efficiency air to water heat pumps with E.V.I. compressors

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

ULTRATEMP HIGH PERFORMANCE HEAT PUMP

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

Advantages of R290 (Propane) and other hydrocarbons

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Transcription:

4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by

FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 / ESEER 4.79 / SCOP 3.2 All Inverter Scroll Water Outlet Control Without Hunting Enhanced Heating Performance by Vapor Injection Cycle Reliability & Stability CONTENTS Continuous Heating Operation Back Up Operation In Case Emergency Quick Maintenance Using Black Box Function Corrosion Resistance Ocean Black Fin Convenience 06 HIGH EFFICIENT INVERTER TECHNOLOGIES All Inverter Scroll Smaller Footprint Due to Compact Size Low Noise Level Silent Operation Function 5 Inch HMI Touch Controller with Various Functions Lower Load Operation Vapor Injection 08 RELIABILITY & STABILITY Continuous Heating Operation Back Up Operation Corrosion Resistance (Ocean Black Fin) Black Box Function 10 CONVENIENCE Compact Size Low Noise Level Silent Operation Function (Cooling Mode) HMI Touch Controller Centralized Control of LG CHILLER (Option) Easy BMS Interface 14 APPENDIX Specification Heat Pump Model Specification Cooling Only Model

WHY LG CHILLER? By applying world class EHP technology of MULTI V, high efficient and reliable operation has achieved. LINE-UP The capacities of base models are 60 / 123 / 185 kw and Max. 10 CHILLERS can be controlled by 1 central controller up to 1,850kW. Capacity (kw ) 60 123 185 Heat Pump Model (ACHH *** LBAA) Cooling Only Model (ACAH *** LBAA) 2 Lower Load Operation Wide Range of Frequency Down to 15Hz Minimum Operation 10% Operation range (Hz) Up to 1,850 kw (10 CHILLERS) by ACP (Advanced Control Platform) 125 120 Range of Unit Control 20 15 Other Company s SCROLL CHILLER LG SCROLL CHILLER Up to 925 kw (5 CHILLERS) by AC Smart Controller HMI Up to 925 kw (5 CHILLERS) by HMI Touch controller Central controller ACP, AC Smart controller are option. 3 Continuous Heating Operation 5 Heating 4 1 Continue Heating When Defrosting Defrost 3 2 OUR CHILLER HISTORY Equipped with a comprehensive, full line-up of HVAC solutions, LG offers optimized solutions tailored to meet customer requirements. 2015 Making a Leap Forward as a Global Company 2012 2012 Total 92,288RT Centrifugal CHILLERS Provided in Saudi Arabia (Qurayyah IPP) 2008 Expanding Our Capability Thru Innovation AHRI Certification Acquired 2007 1997 1 Inverter Technologies of LG EHP* 4 Pressure Control Vapor Injection and HiPORTM** More Precise and Reliable Operation / Applied to MULTI V Control Logic Vapor Injection HiPORTM Technology Sensor High Pressure Gas EHP : Electric Heat Pump HiPORTM : High Pressure Oil Return Pressure Sensor Building Our Base 1968 5 R-410A Refrigerant ODP* = 0, Eco-Friendly Refrigerant ODP : Ozone Depletion Potential 2 Stage Centrifugal CHILLER Developed First Shipment of Centrifugal CHILLER for Nuclear Power Plant LG CHILLER Business Launched Direct Oil Return CHILLER Business in Middle East Started (Motor City, 80,000RT, 32Units) China Factory Established 1970 Water Cooled Centrifugal CHILLER (R11) Produced Low Pressure Gas Medium Pressure Gas 1983 World s First Air-Bearing Oil-Free Centrifugal CHILLER Developed

HIGH EFFICIENT INVERTER TECHNOLOGIES ALL INVERTER SCROLL COMPRESSOR All inverter scroll compressor with HiPOR TM (Patent) is applied to improve full load and part load energy efficiency. All Inverter System Wide operation frequency range 15 ~ 125 Hz LOWER LOAD OPERATION 10% Part load operation and minimizing water outlet temperature haunting with Inverter scroll compressors. LG Inverter Scroll Minimum 10% Operation Target 7 C Inverter 15Hz Inverter 20Hz Normal On/Off Multi System Minimum 50% Operation Oil Separator Target 7 C HiPOR TM On/Off 0% On/Off 100% HIGH ENERGY EFFICIENCY Inverter125Hz Inverter120Hz HiPOR TM (Patent) Maximizing reliability and efficiency of the compressor through recovering oil in compressor directly All inverter SCROLL compressors with MULTI V technologies improve energy efficiency. Cooling Performance 2.44 A Co. EER 9% 2.65 LG 3.64 A Co. 3.75 B Co. ESEER* 4.1 C Co. 32% 4.79 LG Heating Performance 2.97 A Co. COP 8% 3.2 LG 3.09 A Co. 3.15 B Co. SCOP** 4% 3.2 LG VAPOR INJECTION Vapor injection technology (2 stage compression effect) improves heating performance by 27% for cold region. Vapor Injection 2 Stage Compression Effect Heating Performance Energy Efficiency High Pressure Gas Discharge Mid Pressure Gas Suction Low Pressure Gas Suction EEV SC HEX Mid Suction 2 nd STAGE Low Suction 1 nd STAGE High Discharge Improved Heating Performance Thanks to Vapor Injection and HIPOR TM Technology, Heating Performance Improved by 27% Heating Capacity 160% 140% 120% 100% 80% 60% HiPOR TM + VI 27% Increase HiPOR TM Normal Outdoor C -20-15 -10-5 0 185 kw Heat pump model comparison * ESEER : European seasonal energy efficiency ratio ** SCOP : Seasonal coefficient of performance Evaporator 06 / 07

RELIABILITY & STABILITY CONTINUOUS HEATING OPERATION Continuous heating minimizes the decrease of water outlet temperature during defrosting for multi circuit model. 123kW (40 RT) and 185kW (60 RT) model with multi cycle can defrost each cycle individually to supply hot water continuously CORROSION RESISTANCE Ocean Black Fin heat exchanger is highly corrosion resistant, designed to perform in corrosive environments such as contaminated and humid condition. (OCEAN BLACK FIN) Longer Lifespan, Lower Operational Costs Strengthened Corrosion Resistant Coating Hydrophilic Coating Heating Operation Heating Operation Defrost Evaporator Evaporator Evaporator Water Outlet BACK UP OPERATION Corrosion Resistant Black Coating EEV EEV EEV The hydrophilic coating minimizes moisture buildup on the fin. The black coating provides strong protection from corrosion. Water Inlet If one compressor or one cycle has a trouble or be repaired, backup operation helps whole cycle to operate continuously. Between Two s Backup Break Down OFF ON OFF Automatic Emergency Backup Break Down ON ON OFF Aluminum Fin BLACK BOX FUNCTION Quick service can be done because operation data can be saved for 180 seconds before system failure. Without Black Box Function With Black Box Function Check many failure causes and error codes in person Search for the failure cause conveniently using recoded data Take much service time and undergo trial and error Save service time and diagnose it more accurately Record operation data for 180 seconds before system failur! Among The Cycles Operating Operating Repairing 08 / 09

CONVENIENCE COMPACT SIZE LG SCROLL CHILLER S installation space is much smaller than A company s due to compact size. (43% Reduction) Foot Print Comparison SILENT OPERATION FUNCTION Silent operation function can reduce noise levels at night time by adjusting the fan RPM Fan (COOLING MODE) 4.9m2 RPM Noise Capacity 43% Area Peak Load Load A Co. 8.6m2 B Co. 5.4m2 185kW (60 RT) Comparison Sound Level LOW NOISE LEVEL Reduce Noise Lower noise can remove complains from noise pollution and provide a quieter environment. Noise Comparison 3dB 185kW (60 RT) Comparison (Heat Pump Model) 90 db(a) 8 db(a) 76 db(a) Highest Outdoor 68 db(a) Day 8 hours Mode Start Night 9 hours Time Mode End Day 60 db(a) 50 db(a) Typical Urban Daytime Commercial Area LG SCROLL CHILLER A Company SCROLL CHILLER Truck 10 / 11

CONVENIENCE HMI TOUCH CONTROLLER High level control option is preinstalled such as cycle monitoring, schedule control and demand control with HMI touch controller. User Friendly HMI Touch Controller 5 TFT LCD Touch screen Unit Mounted (Factory Installed) EASY BMS INTERFACE LG provides CHILLER controller system and BMS communication function. BMS : Building Management system * LG ACP BACnet / LONwork Gateway is unconvertable to LG CHILLER. Direct Modbus connection is available. LG HVAC Group BMS Modbus *LG Gateway Checking CHILLER Information (Pump / Flow Status, Pump On / Off, Flow Switch On / Off Etc.) Monitoring CHILLER Operation (Each Cycle Operation Status, Air Etc.) Scheduling Function Anti-Freezing Function / Displaying Error History Etc. RS485 1Port, SD Card (Memory) 500m Remote Controlling MAX 500M HMI Touch Controller Can Be Installed Separately In Operation Room RS485 communication Operation Room CHILLER AHU EHP AWHP LG Central Controller CHILLER Kit (S/W) Ventilation Field devices CENTRALIZED CONTROL OF LG CHILLER (OPTION) LG central CONTROLLER IV series (+CHILLER kit) provide CHILLER remote control and cycle monitoring (ACP IV : Max. 10 CHILLERS, AC SMART IV : Max. 5 CHILLERS). CHILLER Status Overview Security Lighting Sensor Other Company s HVAC Group Actuator Valve Main View Web Access Control and Monitor by Web Access ACP IV + CHILLER kit Various HVAC Units Scroll, Screw, Centrifugal CHILLER Absorption CHILLER & Heater A/C, Ventilation, AHU, AWHP Detail / Cycle view Control /Monitor view Detailed Control and Monitor Control and Monitor on Screen Schedule Operation Automatic Unmanned Operation 12 / 13

SPECIFICATION HEAT PUMP MODEL (LG) participates in the ECP programme for (EUROVENT LCP-HP program). Check ongoing validity of certificate: www.eurovent-certification.com COOLING ONLY MODEL (LG) participates in the ECP programme for (EUROVENT LCP-HP program). Check ongoing validity of certificate: www.eurovent-certification.com Capacity Input Power Efficiency Sound Power Refrigerant Fan motor Dimension Protection Devices Inverter SCROLL CHILLER Model ACHH020LBAA ACHH040LBAA ACHH060LBAA H/P H/P H/P Power Phase, Lines, V 3, 4, 380 ~ 415 3, 4, 380 ~ 415 3, 4, 380 ~ 415 Cooling Heating kw 60.0 123.0 185.0 RT 17 35 53 kw 70.3 141.0 211.0 RT 20 40 60 Cooling kw 22.8 46.4 69.8 Heating kw 22.0 43.9 65.9 Max Operating Current A 52 104 156 Cooling W/W 2.63 2.65 2.65 Heating W/W 3.20 3.20 3.20 ESEER W/W 4.79 4.79 4.79 SCOP W/W 3.20 3.20 3.20 Sound Pressure dba 67 68 68 Cooling 84 91 92 dba Heating 85 92 93 Type - Scroll Scroll Scroll No. of EA 2 4 6 Oil Type - PVE PVE PVE Oil Charge cc 1,400 * 2 1,400 * 4 1,400 * 6 Sump Heater W 60 * 2 60 * 4 60 * 6 Type - R410A R410A R410A Amout of Charged Kg 14 14 * 2 14 * 3 Type - plate plate plate Pressure Drop kpa 58.2 34 34 Operating Maxium Pressure (Refrigrant / Water) kg /cm 2 42 /10 42 /10 42 /10 Standard Flow (Cooling / Heating) LPM 172 / 202 353 / 404 531 / 604 Inlet / Outlet Diameter (Water Pipe) mm 40A / 40A 65A / 65A 65A / 65A Type - BLDC BLDC BLDC No. of Fan EA 2 4 6 No. of Vanes EA 4 4 4 Air Flow Rate CMM 210 * 2 @1,000rpm 210 * 4 @1,000rpm 210 * 6 @1,000rpm Motor Power W 900 * 2 900 * 4 900 * 6 Expension Unit - EEV EEV EEV Weight kg 540 1,030 1,530 W mm 765 1,528 2,291 H mm 2,351 2,351 2,351 D mm 2,154 2,154 2,154 Footprint m 2 / RT 0.097 0.094 0.094 High / Low Pressure - Anti Frost - Reversed Phase Sensor - Flow Switch - Remote Control - Modbus Modbus Modbus Power Power Line mm 2 25.0mm 2 5C 50.0mm 2 5C 95.0mm 2 5C Outlet Ambient Cooling 5 ~ 15 5 ~ 15 5 ~ 15 Heating 35 ~ 55 35 ~ 55 35 ~ 55 Cooling -10 ~ 48-10 ~ 48-10 ~ 48 Heating -15 ~ 35-15 ~ 35-15 ~ 35 Earth Leakage Breaker A 75 125 200 Capacity Input Power Inverter SCROLL CHILLER Model ACAH020LBAA ACAH040LBAA ACAH060LBAA C/O C/O C/O Power Phase, Lines, V 3, 4, 380 ~ 415 3, 4, 380 ~ 415 3, 4, 380 ~ 415 Cooling kw 60.0 123.0 185.0 RT 17 35 53 Cooling kw 22.8 46.4 69.8 Max Operating Current A 52 104 156 Efficiency Cooling W 2.63 2.65 2.65 ESEER W/W 4.79 4.79 4.79 Sound Pressure dba 67 68 68 Sound power Cooling dba 84 91 92 Refrigerant Fan Motor Dimension Protection Devices Type - Scroll Scroll Scroll No. of EA 2 4 6 Oil Type - PVE PVE PVE Oil Charge cc 1,400 * 2 1,400 * 4 1,400 * 6 Sump Heater W 60 * 2 60 * 4 60 * 6 Type - R410A R410A R410A Amout of Charged Kg 15 15 * 2 15 * 3 Type - Plate Plate Plate Pressure Drop kpa 58.2 34 34 Operating Maxium Pressure (Refrigrant / Water) kg /cm 2 42 / 10 42 / 10 42 / 10 Standard Flow (Cooling) LPM 172 353 531 Inlet / Outlet diameter (Water pipe) mm 40A / 40A 65A / 65A 65A / 65A Type - BLDC BLDC BLDC No. of Fan EA 2 4 6 No. of Vanes EA 4 4 4 Air Flow Rate CMM 210 * 2 @1,000rpm 210 * 4 @1,000rpm 210 * 6 @1,000rpm Motor Power W 900 * 2 900 * 4 900 * 6 Expension Unit - EEV EEV EEV Weight kg 525 1,000 1,470 W mm 765 1,528 2,291 H mm 2,351 2,351 2,351 D mm 2,154 2,154 2,154 Footprint m 2 / RT 0.097 0.094 0.094 High / Low Pressure - Reversed Phase Sensor - Flow Switch - Remote Control - Modbus Modbus Modbus Power Power Line mm 2 25.0mm 2 5C 50.0mm 2 5C 95.0mm 2 5C Outlet Ambient Cooling 5 ~ 15 5 ~ 15 5 ~ 15 Cooling -10 ~ 48-10 ~ 48-10 ~ 48 Earth Leakage Breaker A 75 125 200 14 / 15