New CGAF New Air-Cooled Scroll Chiller CGAF
New CGAF CGAF Air cooled Scroll Chiller 170 700 kw Cooling Only CXAF 150 700 kw Heat pump Coming soon 2
New addition to the Sintesis Family: Multiple technologies, exceptional performances, proven reliability! RTAF:Screw compressors High speed centrifugal compressors Scroll compressors Most versatile Chiller Portfolio in the Industry! 3
Benefits Market leader Sintesis platform, multiple technologies available Fast lead time, easy maintenance and service Remarkable performance, optimized for part loads 3 efficiency levels and 3 acoustic packages Wide capacity range, cost-effective solutions, small footprints No compromise, flexible offer to better meet customer needs 4
Wide offer in terms of capacity, efficiency and acoustic Cooling capacity 170 700 kw 3 Efficiency level Standard efficiency 3 Acoustic level Standard noise Energy saving solutions EC fans 14 sizes High efficiency Low noise Free cooling Extra high efficiency Extra low noise Total heat recovery EER up to 3.34 Night noise set back for extra silent operation Partial heat recovery ESEER up to 4.55 5
Main Features AC Fans EC Fans EC + AC Fans Redesigned fan diffuser Refrigerant R410A Brazed plate heat exchanger Free Cooling Standard Optional Micro-channel condenser coil Scroll Compressors And more! Total and partial Heat recovery Buffer Tank Soft Starter Freeze Protection Hydraulic module UC800 TD7 6
Compact design and layout 22% smaller compared to Trane legacy products V shaped coils 6 Frames layout: from 2V to 6V Integrated Hydraulic module Single or dual pump kit 7
Micro-channel condenser coils Excellent heat transfer and a greater corrosion resistance versus conventional tubes in fins coils 100% aluminum Longer life expectancy Increased efficiency with less refrigerant Slit fins and brazed contact for improved heat transfert and strength Air condenser inlet Reduced carbon footprint 10% overall unit weight reduction Micro channels for R410a Air condenser outlet 8
Electronically Commuted (EC) Fans EC fans are the perfect option to reduce power consumption at part load, allowing also a significant reduction of sound level Improved capacity modulation Reduced power consumption and energy costs Better operation at low ambient conditions
Premium efficiencies: remarkable performances Standard efficiency EER up to 3.04 ESEER up to 4.15 High efficiency EER up to 3.34 ESEER up to 4.16 Extra high efficiency EER up to 3.34 ESEER up to 4.55 Energy saving EC fan motors (optional) Optimized fan diffusor Free cooling solutions All units will be compliant with Ecodesign regulation 2018 10
Top class part load efficiencies 8% more efficient at part load compared to the benchmark 11
Soundproof operation: extra low noise emission Standard noise: SN Sound power level from 87 to 98 db(a) Low noise: LN Sound power level from 84 to 95 db(a) Compressor jacket Extra low noise: XLN Sound power level from 83 to 92 db(a) Piping insulation Compressor sound box Night noise setback available 12
For even greater acoustic comfort Silent mode with the Night Noise Set Back Thanks to the Night Noise Set Back it is possible to set an extra silenced operation profile The sound level of the chiller is reduced by decreasing the speed of EC fans, controlled with an external on/off contact This option is designed for night operation, allowing perfect acoustic comfort at night time without compromising the efficiency during times of greater load Industry-leading fan diffusor EC fans can be equipped with a special diffuser to provide a quieter operation and air flow optimization Efficiency is boosted by converting dynamic airflow into static pressure allowing a fan speed reduction, with the effect of lower acoustic pressure and energy consumption with unchanged airflow 13
Energy saving solution Reduce energy costs by taking advantage of low ambient conditions or converting the energy produced the during cooling cycle Free Cooling Designed for applications that requires cooling all year round with simultaneous heating demands Heat Recovery Heat recovery system re-uses the waste heat generated during the cooling cycle, instead of exhausting it to the atmosphere It is possible to choose between two different level of heat recovery Total Heat Recovery (THR) When THR mode is ON, the chiller can produce heating up to 130% of the cooling capacity Partial Heat Recovery (PHR) When PHR mode is ON, the chiller can produce heating up to 25% of the cooling capacity 14
Extended operating limits for process and comfort application Trane Sintesis Avdantage chillers are designed for all year-round operation over a wide range of ambient temperatures Standard ambient: -10 C to +46 C Low ambient: -20 C to +46 C High ambient: -10 C to +52 C Wide ambient: -20 C to +52 C 15
Flexible and versatile product configuration and selection EC Axitop Multiple bundles to choose from: always the right product for every application! 16
Simple and intuitive user interface Controller Trane Tracer UC800 Advanced algorithms to manage the most challenging conditions Ease of maintenance and service Modular bus architecture to cover product range User interface with front panel TD7 Large touch screen Full-color interface for simple, intuitive operation Main processor in the control panel Settings Reports Data trends & graphs Alarms 17