SPECTRA 1728, 1738 CHEAT SHEET: ZONE MAPPING: Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE 4 & 9 INPUT 5= ZONE 5 ZONE 5 & 10 INPUT 6= N/A N/A INPUT 7= N/A N/A KEYPAD ZONE 1= ZONE 6 ZONE 11 ZONE 2= ZONE 7 ZONE 12 ATZ = Zone Doubling The Zone doubling feature allows you to install two devices per hardwired input terminal. Each detection device will have its own zone, display its own zone status on the keypad and send separate alarm codes for each zone. Each zone is differentiated by a different resistor value. EXPANSION INPUT 1= ZONE 8 ZONE 13 INPUT 2= ZONE 9 ZONE 14 INPUT 3= ZONE 10 ZONE 15 INPUT 4= ZONE 11 ZONE 16 INPUT 5= ZONE 12 N/A INPUT 6= ZONE 13 N/A INPUT 7= ZONE 14 N/A INPUT 8= ZONE 15 N/A *A location is referred to as a section. *Value or data is referred to as an option. 1
HOW ENTER PROGRAM MODE: PRESS THE ENTER KEY ENTER THE INSTALLER CODE (DEFAULT: 0000). ENTER LIGHT WILL FLASH (PROMPTING A SECTION NUMBER BE ENTERED) ENTER 3 DIGIT SECTION. ENTER LIGHT WILL TURN ON SOLID (INDICATING THAT YOU ARE AT A SECTION NUMBER) ENTER DATA AS REQUIRED * PRESS CLEAR ONCE STEP BACK ENTER LIGHT FLASHING HOW PROGRAM ZONES: GET IN PROG. MODE: ENTER SECTION NUMBER (e.g : 001 = Zone 1) STEP 5: STEP 6: ENTER ONE DIGIT FROM THE ZONE DEFINITION TABLE (i.e. instant, follow {handover}, entry) ENTER ONE DIGIT FROM THE PARTITION ASSIGNMENT TABLE (you are assigning that zone to an area/partition) SELECT ONE OR MORE OPTIONS FROM THE ZONE OPTIONS TABLE (This table is a toggle ON/OFF feature.) I.e. if key 2 is on = Bypassable zone, this means it is enabled. If you want to disable it, press key 2, and the led will turn off. This disables that option. PRESS ENTER SAVE *PANEL AUMATICALLY JUMPS NEXT ZONE ADDRESS IN ZONE PROGRAMMING SYSTEM TIMERS: SECTION: [069] ENTRY DELAY 1 *45 SECS SECTION: [071] EXIT DELAY 1 *30 SECS SECTION: [078] NUMBER OF RINGS *DISABLED SECTION: [087] AU TEST REPORT DAYS *DISABLED SECTION: [110] AU TEST REPORT TIME *DISABLED *Bold is default setting HOW PROGRAM ACCESS CODES: PRESS ENTER KEY IN MASTER CODE KEY IN 3 DIGIT USER SECTION SECTION: [302] MASTER CODE 1 SECTION: [303] MASTER CODE 2 SECTION: [304] USER CODE 4 SECTION: [348] USER CODE 48 (Refer to page 18 of programming guide) STEP 5: KEY IN NEW CODE, ENTER LIGHT WILL FLASH, PROMPTING A NEW USER LOCATION END, PRESS CLEAR. PROGRAM IN USER CODE OPTIONS SECTION 281: INSTALLER CODE 2
LEARNING IN WIRELESS DEVICES: PIR s & TRANSMITTERS (Omnia or 1759EX protocol) GET IN PROGRAMMING MODE KEY IN 3 DIGIT SECTION NUMBER (Refer to page 24 of programming Guide) ENTER IN SERIAL NUMBER OF PIR OR TRANSMITTER SECTION: [601] SERIAL NUMBER = EXPANSION INPUT 1 SECTION: [602] SERIAL NUMBER = EXPANSION INPUT 2 SECTION: [608] SERIAL NUMBER = EXPANSION INPUT 8 (The serial number is found on the PCB of the device.) ENABLE ZONE THAT RELATES THAT EXPANSION INPUT (Refer to zone mapping table) LEARNING IN WIRELESS DEVICES: REMOTE CONTROLS ASSIGN REMOTE CONTROL 3 DIGIT USER SECTION SECTION: [701] _/_/_ REMOTE CONTROL 1 SECTION: [702] _/_/_ REMOTE CONTROL 2 SECTION: [708] _/_/_ REMOTE CONTROL 8 (Refer to page 26 of programming guide) ASSIGN FEATURE OPTIONS YOUR BUTNS SECTION: [711] 1 / 5 / _ / _ / _ / _ / _ / _ / Button: A B C D A+B C+D A+C B+D FOR REMOTE CONTROL 1 SECTION: [712] REMOTE CONTROL No 2 OPTIONS SECTION: [718] REMOTE CONTROL No 8 OPTIONS Programmed here is : (example only) Button A is to operate as Regular Arm = 1 Button B is to operate as Disarm = 5. Then press enter once you have added the options you require. PROGRAM IN THE REMOTES SECTION: [731] FOR REMOTE CONTROL 1. PRESS BUTN A TWICE (a confirmation beep will be heard). SECTION: [732] FOR REMOTE CONTROL 2 SECTION: [738] FOR REMOTE CONTROL 8 ZONE EXPANSION MODULES: (ZX-4 OR ZX-8) ENTER PROGRAM MODE SECTION: [650] OPTION 1 IS ENABLE END OF LINE SECTION: [651] OPTION 1 IS ENABLE EXPANSION INPUT 1 OPTION 2 IS ENABLE EXPANSION INPUT 2 OPTION 8 IS ENABLE EXPANSION INPUT 8 (Option 650 & 651 is a toggle ON/OFF section) ENABLE EXPANSION INPUT ZONES (Refer to zone mapping table) 3
PERSONAL DIAL PROGRAMMING: SECTION: [081] Select max dialing attempts = 2 SECTION: [135] Option 3and 4 and should be ON SECTION: [136] Option 3 should be OFF SECTION: [137] Option 3+4 should be ON only SECTION: [138] Option 1 to 8 should be OFF SECTION: [140] 6 / 6 REPORTING FORMATS TEL1 TEL2 SECTION: [143] 1 / 2 / 3 / 4 PARTITION ACCOUNT NUMBER 1 SECTION: [144] / / / PARTITION ACCOUNT NUMBER 2 REPORTING CODES: SECTION: [151] 0 / 2 / 5 / 1 / 2 / 3 / 4 / 5 / 6 /TBL/TBL/ 3 / 2 / 1 /TBL/ 3 / 2 / 1 /TBL CENTRAL STATION TELEPHONE NUMBER 1 (if less than 32 press [ENTER] to accept) SECTION: [152] 0 / 2 / 5 / 1 / 2 / 3 / 4 / 5 / 6 /TBL/TBL/ 3 / 2 / 1 /TBL/ 3 / 2 / 1 /TBL CENTRAL STATION TELEPHONE NUMBER 2 (if less than 32 press [ENTER] to accept) (When this dials the phone number, the recipient will hear a series of tones (3 2 1) followed by a pause, then there will be a rapid series of DTMF tones as the panel sends the pager message) SECTION: [187] Alarm Reporting codes (zones 1-4) SECTION: [190] Alarm Reporting codes (zones 13-16) STROBE PROGRAMMING: SECTION: [066] PGM1 Timer 0 / 0 / 0 Seconds Event Group # Sub-Group # Partition # SECTION: [120] 0 / 2 0 / 4 9 / 9 SECTION: [121] 0 / 2 0 / 9 9 / 9 STROBE FLASHES ON ARM/DISARM VIA REMOTES : SECTION: [067] PGM2 Timer 0 / 0 / 5 Seconds Event Group # Sub-Group # Partition # SECTION: [122] 0 / 6 9 / 9 9 / 9 SECTION: [123] must be left empty 4
STROBE CONNECTION FOR PGM s: NOTE: Place a link between PGM1 & PGM2 if the arm/disarm strobe flash function is required. Place Link between PGM 1& PGM 2 across here. PGM 1 (-) PGM 2 (-) AUX + 5