Turbo. Service Instructions

Similar documents
Wind. Service instruction

Aero. Service Instructions

Calm. Service Instructions

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

CENTRIFUGAL FANS user's manual. model VENTS VK.

AXIAL FANS USER S MANUAL

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

INTELLIGENT AXIAL FAN user's manual

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

HEAT RECOVERY AIR HANDLING UNIT

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

AXIAL FANS user's manual. model Quiet

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

Turbo Inline Fan, White - Non Illuminated Art no.33500

Axial intelligent fan USER S MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

White - Non Illuminated Art no White - Cool White LED Art no.32600

USER S MANUAL. VKP Series INLINE FAN

Centrifugal inline fans

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

USER'S MANUAL PS

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

HEAT RECOVERY VENTILATOR

AIR HANDLING UNIT WITH HEAT RECOVERY

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

HEAT RECOVERY AIR HANDLING UNITS

Air handling unit. BlauAir RH USER S MANUAL

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

USER S MANUAL DN-2. Drain pump

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Installation manual Mini Comfort 50 S/L 07/ V EN

PH1000T PH1500T PH2000T

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Centrif Duo & Centrif Duo Plus

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

VH60SS 60CM VISOR HOOD STAINLESS STEEL

DRI-ECO-HEAT-HCS Whole House Ventilation Unit with Hall Control

Hotte décorative Decorative Hood Campana extractora decorativa Exaustor decorativo Dekor-Dunstabzugshaube

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Lo-Carbon Quadra Centrifugal Fan

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Silhouette Installation and Wiring Instructions

G Installation manual Solitude - dmev unit

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Lo-Carbon SELV Tempra

K-Star International Group Inc. K-Star Electronic Appliance Inc. Toll Free:(800)

General safety precautions English

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Lo-Carbon Quadra SELV

Cooker Hood LA-72-CAN.

ISCG90SS _03 ISCG90SS

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

EVG Extractors. Manual for Installation, Use and Maintenance

IMPORTANT INSTRUCTIONS READ & SAVE

Range Hoods. General Manual. For Models: IVN900X, IVN900N, IVCC900X, IVCG900, IVSG900

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Transcription:

Turbo Service Instructions E

BAUBERG Company is happy to offer your attention a new highquality inline mixed-flow Blauberg Turbo fan. The solid team of highqualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class. The fan Turbo is a symbiosis of perfect quality, high performance and silent operation. ITRODUCTIO The present service instruction contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan BAUBERG Turbo. USE The fan Turbo is designed for exhaust or supply ventilation of living spaces, kitchens, bathrooms, offices, shops, garages and other residential and public premises heated during winter time. The fan may be integrated into the air ductworks. The fan is available for round Ø 100, 125, 150,160, 200, 250 and 315 mm air ducts. COMPETE SET fan - 1 item; screws and dowels - 4 items; plastic screwdriver (for the models with timer) - 1 item; service instruction; packing box. The fan design is regularly improved, so some models can slightly differ from those ones described in this service instruction. BASIC CHARACTERISTICS The fan designations, parameters, outer view, overall and connecting dimensions are shown in tables 1-2 and in fig. 1 and 2. 2

Fig. 1 4 8 5 3 1 7 2 10 9 6 1 - casing, 2 - impeller, 3 - electronic module, 4 - electronic module cover, 5 - capacitor, 6 - spigot, 7 - motor, 8 - clamp, 9 - collector, 10 - diffuser. 3

170 Max. air flow [m3/h] IP rating Max. transported air temperature [ C] oise level, 3 m [dba] 25 220 230 0.11 0.11 25 max min 42 50 42 345 430 560 430 0.13 0.19 0.22 0.19 29 min 560 0.22 50 108 125 177 227 min 315 max Turbo 315 805 1080 1070 1360 1420 1750 0.34 0.48 0.54 0.79 0.99 1.42 76 max Turbo 250 max min Turbo 200 1 230 max Turbo 160 max min Turbo 150 max min Turbo 125 27 32 29 34 37 46 IP 4 60 37 46 45 52 47 55 47 56 1980 2545 1535 2265 1940 2620 1940 2620 1915 2380 1955 2440 2115 2505 0.10 Current [A] RPM [min-1] 23 min Turbo 100 Power [W] Voltage, 50/60 Hz [V] Speed Parameters Table 1 4

Table 2 Type Turbo 100 Turbo 125 Turbo 150 Turbo 160 Turbo 200 Turbo 250 Turbo 315 Weight Dimensions [mm] B H [kg] 164 196 241 303 1,55 123 148 164 187 196 241 251 258 1,5 220 289 2,1 158 187 220 251 289 2,2 199 209 239 261 295.5 6,4 247 257 287 323 383 8,3 310 323 362 408 445 11,4 D D1 97 Fig. 2 5

MODIFICATIOS AD OPTIOS T - adjustable run-out timer regulated from 2 to 30 minutes. US three-position speed switch integrated in the fan (Min speed - off Max speed) FR - built-in smooth speed controller from 0 to 100%. The fan is supplied with a pre-wired power cable with IEC C14 plug as a standard. The cable modification with a standard electric plug is also available (FR1). G/GT - smooth speed controller with an electronic thermostat and an external temperature sensor that is fixed on 4 m power cable. The fan is supplied with a pre-wired power cable with IEC C14 plug as a standard. The cable modification with a standard electric plug is also available (G1). GI/GTI - smooth speed controller with an electronic thermostat and a temperature sensor integrated into the air duct. The fan is supplied with a pre-wired power cable with IEC C14 plug as a standard. The cable modification with a standard electric plug is also available (GI1). W - pre-wired power cable and IEC C14 plug as a standard. Modification with a standard electric plug is available (W1). COTRO OGIC The model Turbo T switches on when the voltage is supplied to the terminal T by the external switch (i.e., light switch). After the control voltage is disconnected the fan continues operating during the time T, which is regulated from 2 till 30 minutes. To regulate the turn-off delay time turn the potentiometer T clockwise to increase it to max. 30 min or anticlockwise to decrease it to min. 2 min (Fig. 27) Warning! The timer circuit is under mains voltage! Disconnect the fan from power mains prior to any adjustment operations. The fan delivery set includes a specially designed plastic screwdriver for the timer setting adjustments. Do not use a metal screwdriver, knife, etc. for adjustment operations not to damage the circuit board. The model Turbo FR (fig. 26) is equipped with a speed controller to turn the fan on/off and smooth control of the fan speed over the range from minimum to maximum speed. 6

The model Turbo G/Gl (fig. 25) is equipped with a temperature and speed controller with external temperature sensor for automatic speed (air flow) regulation depending on ambient temperature. The electronic module has two control knobs: to set the motor speed; to set the electronic thermostat setpoint. The thermostat ED pilot light on the fan casing glows red when the transported air temperature exceeds the set point. To set the thermostat setpoint rotate the thermostat control knob clockwise to increase it and anticlockwise to decrease the value. To set the speed (air flow) control setpoint rotate the speed control knob in the same way. The fan has two operating logics: based on temperature and timer: temperature-based logic (G/Gl): to keep air temperature within 2 C. In this case the speed switches are rare. When air temperature rises up to the thermostat set point, the fan switches to maximum speed. When air temperature drops down 2 C below the set point or when the initial temperature is below the set point, the fan runs with the speed set by the speed controller. timer-based logic (GT/GTl): to keep air temperature exactly. The fan switches more frequently as compared to the previous pattern but the minimum time intervals in any case are not less than 5 minutes. When the air temperature rises up to the thermostat set point, the fan switches to maximum speed. Synchronously the speed switch delay timer is activated for 5 minutes. When the air temperature drops down below the set point, the fan keeps running on maximum speed for additional 5 minutes and then switches back to set speed. If the initial temperature is below the set point, the fan runs from beginning with the set speed by the speed controller. 7

SAFETY RUES All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. The single-phase power grid must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic switch that is used for connection of the fan to power mains with gap on all poles at least 3 mm. The circuit breaker trip current must be in compliance with the fan current consumption, refer Table 1. Make sure the impeller and the casing are not damaged before connecting the fan to power mains. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the product or any unauthorized modification are not allowed. Disconnect the fan from power mains prior to any servicing and repair operations. Misuse of the product or any unauthorized modification are not allowed. The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the product. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. The maximum permitted pressure difference per living units is 4 Pa. Transported medium must not contain any dust or other solid impurities, sticky substances or fibrous materials. The fan is not rated for operation in a media that contains hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or exhaust vent not to disturb the natural air passage. Do not sit on the fan and do not put objects on the fan. Follow the guidelines of this service instructions to ensure durable operation of the product. 8

FA MOUTIG The fan is designed for vertical or horizontal mounting to the wall, ceiling or installation on the floor, fig. 3-6. The air motion direction in the system must match the pointer on the fan casing. The fan is suitable for individual installation of one unit (fig. 3-6) or two or more units mounted in parallel (TD) or in series (T), fig. 7-8. The parts for the connecting kits are ordered and delivered separately. While mounting protect the fan against water ingress in the following way: 1. In case of the vertical mounting position: install a protecting hood on the top, fig. 6. 2. In case of any mounting position: connect air duct at least 1 m long on both sides of the fan, fig. 4. Fig. 3 Fig. 4 1m Fig. 5 Fig. 6 Fig. 7 Fig. 8 9

Mounting sequence: - cut power supply off, fig. 9; - remove the clamps that retain the fan casing, fig. 10-11; - release the fan casing, fig. 13; - mark the fastening holes on the mounting surface through the respective holes in the spigots, drill the holes and fix the spigots with screws, fig. 13-15; - connect air ducts to the fan casing, fix the casing with the clamps, rotate the fan casing in such way as to place the terminal compartment Fig. 9 Fig. 10 Fig. 11 Fig. 12 10

Fig. 13 Fig. 14 Fig. 15 Fig. 16 11

COECTIO TO POWER MAIS Turbo 100/125 2 fan runs at MA speed Wiring diagram 1 1 fan runs at MI speed Wiring diagram 2 fan runs at MI speed 1 S 2 Speed switch is activated fan runs at MA speed Speed switch is activated Wiring diagram 3 1 2 Wiring diagram 4 12

Turbo 150/160/200/250/315 2 fan runs at MA speed Wiring diagram 5 1 fan runs at MI speed Wiring diagram 6 fan runs at MI speed 1 S 2 Speed switch is activated fan runs at MA speed Speed switch is activated Wiring diagram 7 1 2 Wiring diagram 8 13

Turbo 100 T/125 T/150 T/160 T/200 T/250 T Fan does not run ST Switch ST is closed T fan runs at MA speed Switch ST is open Turn-off delay timer starts (2 to 30 min) Wiring diagram 9 Fan does not run ST T Switch ST is closed 1 fan runs at MI speed Switch ST is open Wiring diagram 10 Turn-off delay timer starts (2 to 30 min) 14

Turbo 100 T/125 T/150 T/160 T/200 T/250 T ST T S 1 Fan does not run Switch ST is closed no Switch S is closed fan runs at MA speed Switch ST is open Turn-off delay timer starts (2 to 30 min) Wiring diagram 11 15 yes fan runs at MI speed

Turbo 315 T Fan does not run ST Switch ST is closed T 2 fan runs at MA speed Switch ST is open Turn-off delay timer starts (2 to 30 min) Wiring diagram 12 Fan does not run ST T Switch ST is closed 1 fan runs at MI speed Switch ST is open Wiring diagram 13 Turn-off delay timer starts (2 to 30 min) 16

Turbo 315 T ST T S 2 1 Fan does not run Switch ST is closed 2 Switch S is closed in position fan runs at MI speed fan runs at MA speed Switch ST is open Turn-off delay timer starts (2 to 30 min) Wiring diagram 14 Wiring diagram 15 17 1 2 1

Turbo 100/125 US Wiring diagram 16 Turbo 150/160/200/250/315 US Wiring diagram 17 II Built-in speed switch in position I 0 fan runs at MI speed fan runs at MA speed Fan does not run 18

Mounting sequence for connection to power mains of the basic model with a built-in speed switch with no power cable and of a fan with a timer: - cut power supply off by turning the electric switch to OFF position, fig. 17. - remove the screws to detach the cover from the electric module and remove the cover, fig. 18. - remove the screws of the retaining clamp and remove the retaining clamp, fig. 19. - route the cable into the terminal box through the electric lead-in and fix the cable with the retaining clamp and the screws, fig. 20. - select the fan operation mode - running at maximum speed, running at low speed or speed control with the external speed switch. - connect the power cable to the fan input terminal block in compliance with a selected wiring diagram, fig. 20 and 21. Do not connect and terminals jointly to 1 und 2 terminals, refer wiring diagrams 4, 8 and 15. - install the terminal box cover and fix it with screws, fig. 22. - switch the fan on by turning the automatic switch to O Position, fig. 23. Fig. 18 Fig. 17 19

Fig. 19 Fig. 20 Fig. 21 Fig. 22 Fig. 23 20

The fan models W/W1/FR/G/G1/Gl/Gl1/GT/GT1/GTl/GTl1 are equipped with a power cable with various plug types are do not require any mounting operations for connection to power mains. Fig. 24 II I Built-in speed switch in position 0 fan runs at MI speed fan runs at MA speed Fan does not run 21

Fig. 25 Speed control knob Thermostat control knob G/G1/Gl/Gl1 GT/GT1/GTl/GTl1 The fan runs with set air flow The fan runs with set air flow Temperature rises Temperature rises fan runs at MA speed Temperature falls 2 C below the temperature point fan runs at MA speed Temperature drops to a set point Speed switch delay timer is activated (5 min) 22

Fig. 26 Speed control knob FR/FR1 The fan runs with set air flow Fig. 27 - T 2min 23 + 30min

MAITEACE Any servicing and maintenance operations of the fan are allowed after it is disconnected from power mains only, fig. 28. Maintenance means regular (at least once in 6 months) cleaning of the fan surfaces from dirt and dust. To clean the fan, wipe its surfaces with a cloth wetted in a mild soap solution, then wipe the surfaces dry, fig. 29-32. Avoid water dripping on the motor and circuit board! Fig. 33. Fig. 28 Fig. 29 Fig. 30 Fig. 31 24

Fig. 32 Fig. 33 STORAGE AD TRASPORTATIO RUES Transportation is allowed by any transportation vehicle provided that the product is in the manufacturer's original package. Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the ambient temperature from +5 C up to + 40 C and relative humidity less than 80%. The storage environment must be free of dust, acid or alkali vapours to prevent corrosion. MAUFACTURER'S WARRATY The fan complies with the requirements according to the EU norms and directives, to the relevant EU-ow Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC and ow Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Assessment of compliance of the product with the requirements relating to electromagnetic compatibility was based on the following standards. 25

Protection degree index according to IP rating against access to hazardous parts and water ingress - IP4. The fan does not require grounding. The manufacturer hereby warrants normal operation of the fan over the period of five years from the retail sale date provided observance of the installation and operation regulations. In case of failure due to faulty equipment during the warranty period the consumer has the right to exchange it. If case of no confirmation of the sale date, the warranty term shall be calculated from the manufacturing date. The replacement is offered by the Seller. The MAUFACTURER shall not be liable for any damage resulting from any misuse of or gross mechanic interference with the fan. Please follow the applicable instructions. DISPOSA Do not dispose in domestic waste. The unit contains in part material that can be recycled and in part substances that should not end up as domestic waste. Dispose of the unit once it has reached the end of its working life according to the regulations valid where you are. 26

WARRATY CARD 27

Fan is recognized as serviceable US 100 G 125 GI 150 GT Turbo 1 160 GTI 200 FR 250 W 315 T SAES DATE MAUFACTURED O (DATE) Date of manufacture is provided on product label SOD APPROVA MARK Blauberg Ventilatoren GmbH Aidenbachstr Str. 52. 81379 Munich, VAT ID: DE 287350231 TURBO_E-06