Installation & Operation Instructions

Similar documents
Installation & Operation Instructions

Safety & Installation Instructions

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Safety & Installation Instructions

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Installer Guide. WARNING Important Safety Information. 1 Specifications

Safety & Installation Instructions

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Installer Guide. WARNING Important Safety Information. 1 Specifications

WHITE-RODGERS COMFORT-SET 90 SERIES

LZP-2 ZONE CONTROL PANEL

TZ-4 TotalZone Zone Control Panel

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

CommStat 4 Controller

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Emerson Blue Easy Set 1H/1C

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

T-32-TS Touchscreen Thermostat. Installation Manual

Operator: Save these instructions for future use!

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Heat Pump Defrost Board Replacement Kit

Detailed Installer Guide

Safety & Installation Instructions

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Safety & Installation Instructions

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

T8411R Electronic Heat Pump Thermostat

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Model number is located on back of thermostat.

Safety & Installation Instructions

Safety & Installation Instructions

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Operator: Save these instructions for future use!

WARNING Important Safety Information

1F98EZ-1421, Easy Install

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation and Setup Guide

Operator: Save these instructions for future use!

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

Commercial Touchscreen Thermostat

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Operator: Save these instructions for future use!

Installation, Operation, and Troubleshooting Instructions

Comfort System T-21-P Touchscreen Thermostat Installation Manual

WARNING Important Safety Information

QUICK INSTALLATION GUIDE

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

TCONT602AF22MA. Programmable Comfort Control. Installation Instructions 18-HD37D1-1

VisionPRO 8000 with Wi-Fi

DXM2 Digital Heat Pump Controller

SC Installation, Operation & Application Guide

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

SC Installation, Operation & Application Guide

T8401C Electronic Thermostats

EL-TSTAT-8820 Safety & Installation Instructions

Operator: Save these instructions for future use!

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Installation Instructions

T8611M Deluxe Programmable Heat Pump Thermostats

PRO Installation. Touch Wi-Fi Thermostat

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Installation Instructions

Operator: Save these instructions for future use!

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

T7200D,E Series 2000 Commercial Microelectronic Thermostats

50A Integrated Furnace Control

INSTALLATION & OPERATION MANUAL

Operator: Save these instructions for future use!

tcu.z Commercial Programmable Thermostat Installation Instructions

For Quick Set-Up go to Page 14

WARNING Important Safety Information

SmartZone TM System Manual

1F95EZ-0671 Non-Programmable 7 Day. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

THERMOSTATS 126. MECHANICAL THERMOSTATS 1C20 / 1C21 / 1C26 / 1E30 / 1E56 / 1F56... Wiring Diagrams / Configuration

FP EZ4F 4 Zone Controller

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

50A Integrated Furnace Control

B SERIES ELECTRIC FURNACE

Verasys System Operation Overview Technical Bulletin

PRO Installation. Thermostat Wi-Fi

Smart Temp. Model

Installation Instructions

PECO. WavePRO Wireless System INSTALLATION GUIDE: T2500 THERMOSTAT AND R2500 RECEIVER. The Peco WavePRO Wireless System

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

H32 Uni- Zone Model H32

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

Detailed Installer Guide

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat

SC Installation, Operation & Application Guide

Transcription:

Installation & Operation Instructions 200 MPS Series Arzel Zoning Technology, Inc. 4801 Commerce Pkwy. Cleveland, OH 44128 Ph: (216) 831-6068 or Toll-Free (800) 611-8312 Fax: (216) 831-6074 www.arzelzoning.com

Control Panel This Zoning System must be installed by a qualified HVAC Contractor! Caution - Electrical Hazard Can cause personal injury or equipment damage. Disconnect power to all systems before beginning installation. WHEN INSTALLING THIS PRODUCT... 1. Read these instructions carefully. Failure to follow them could damage the Arzel Zoning System and/or cause a hazardous condition. 2. Disconnect power supply to the HVAC system and the Arzel system before making any wiring connections to prevent danger, electrical shock, and equipment damage. 3. The Arzel System is designed for indoor use only. 4. You must touch a grounded metal object before handling the Arzel Control Panel to avoid potential loss of internal programs, due to electrostatic discharge. 5. Install in ambient temperature between 40 and 150 F, in a non-condensing area. 6. Complete the Commissioning Checks (p. 8) after installation is complete. 7. The Arzel Zoning System controls the HVAC equipment via a set of dry-contact relays. Be sure that this is compatible with the equipment operating specifications. 8. All wiring must comply with all applicable electrical codes, ordinances, and regulations. 9. Use properly grounded tools. Wear safety glasses and gloves when drilling or cutting sheet metal ducts, fiber glass, or any hard objects. 10. Panel contains both AC and DC. See Equipment Notes (pp. 6 and 7) for more details. 11. Leave these instructions with installed system for future use. Package Contents 1 pc 200 Series Zone Contol Panel (2 or 3 Zone) 1 pc 24VAC self-resetting transformer 1 pc Installation Instructions FEATURES 1. The Arzel Zoning System uses a self-contained, low-pressure air pump to actuate dampers. 2. All zones have full-function, single-stage, heating, cooling, and fan capability from all thermostats. 3. All 200 series systems are both furnace and heat pump compatible. 4. Use any standard 24VAC thermostat, Programmable / Non-programmable, auto/manual changeover/wireless. 5. Built-in heating, cooling, fan priority system. 6. Emergency heat changeover (manual switch or remote outdoor thermostat) for heat pump balance point changeover from heat pump to backup heat functions. 7. Compressor timed off control (delay on break). When the compressor is turned off, it cannot restart for four (4) minutes. This feature allows the refrigerant pressure to balance before restarting. 8. FAN ON HEAT switch generates fan call anytime there is a call for heat: typically used with hydronic coils or electric heat. 9. Manual Pump Switch (MPS ) is provided to start the pump manually and open all the zone dampers. 10. Dampers remain open in the last zone that called for service to take advantage of additional energy savings from blower timed-off cycles that exist on all heating and some cooling equipment. 11. LEDs indicate all system operations. 12. A 40VA, 24VAC, self-resetting, plug-in type transformer is provided to power this 200 series equipment and thermostats. SmartSlave Zones Available Accessories The SmartSlave Zone opens its dampers only when the equipment operation is compatible with the slave thermostat request.

General Operation Information The mini-pump, 1 located in the bottom of the enclosure, runs anytime there is a call from any thermostat. It creates both pressure and vacuum. On a call from any thermostat, the logic board will energize the 2 solenoid valve(s) for non-calling zone(s) and make the appropriate 3 dry contact relays to start the HVAC equipment. Dampers open with vacuum. Dampers close with pressure. The logic board is designed for heating to have priority over cooling and cooling to have priority over fan operation. 2 When all thermostats are satisfied, the air pumps, the HVAC equipment, and the solenoid air valves are de-energized. Dampers will remain in whatever position they were in when the last thermostat call was finished. Leaving the dampers open in the last zone served allows the HVAC system to utilize the residual energy in the system at the end of both the heating and cooling cycles. 3 The Manual Pump Switch (MPS ) is provided to run the pump continuously. Turning the MPS switch to ON manually makes the pump relay and the pump starts, driving all dampers open. This creates a failsafe. If the board fails the dampers can be easily opened and the system run from one thermostat. 1 Equipment Notes THERMOSTATS The 200 Series Arzel Zone Control is compatible with any standard 24VAC thermostat: Wireless, Auto/Manual changeover, Programmable/Non-programmable, Heat/Cool or Fan/Auto/On sub-base switching. If the thermostat has an adjustable heating anticipator (mechanical thermostats), set it to the shortest or lowest setting. Heat pump thermostats are required for heat pump operation. Set up the thermostat to call Y,G in heating: Y,G,O in cooling. LEAVING AIR TEMPERATURE CONTROLS The 200 Series does not monitor the temperature of the air in the ductwork. If positive control is desired, additional temperature controls must be installed. (The Arzel AirBoss series panels do feature a built-in Leaving Air Temperature sensor.) SMARTSLAVE ZONES (Optional) The SmartSlave thermostat does not control the HVAC equipment. It will only open its zone dampers if the HVAC Output call is compatible with the thermostat call. Do not use HP (heat pump) thermostats for a SmartSlave Zone. A SmartSlave Zone thermostat must have a heating-cooling sub-base switch for Fan On (G) to be utilized. Connect R, W, Y, G thermostat terminals to the corresponding terminals on the SmartSlave Zone PC board. Connect SmartSlave Zone damper tubing to the SmartSlave Zone solenoid fitting on top of the panel. Connect the C wire from the SmartSlave thermostat to any zone thermostat C terminal. The HVAC Output C terminal MUST be connected to the common terminal of the equipment transformer for proper SmartSlave operation. BYPASS Closing sections of ductwork will increase static pressure in the system. This will allow the system to heat and cool more effectively. Excessive static can create air noise. A bypass damper will relieve execess static pressure and eliminate objectionable air noise. Please refer to the Arzel Bypass Sizing Chart for guidance on choosing and sizing a bypass system. 3

Quick Start Instructions The Arzel Zoning 200 Series Zoning Systems are easy to install. Please read these instructions completely to ensure that you understand the system. Pay special attention to the Control Panel Section on Page 2. This QuickStart page has been provided as an installation overveiw with references to more detailed information other places in this manual. 1 Install Dampers/Run Tubing Dampers install directly into existing ductwork. Dampers install with the tubing port pointing toward the equipment. Install one tubing run for each zone. Use a tee for multiple dampers on one zone. Arzel recommends using a different color tube for each zone. 3 Connect s Install a thermostat for each zone. Use 18 gauge, multiconductor, solid thermostat wire to connect the thermostats to the control panel. Touch a mechanical ground to discharge static electricity. Connect R,W,Y,G,O, and C as appropriate to the zone terminal strips along the upper right side of the Zone Control Board. Note which thermostats are connected to which zones on the zone layout label on the side of the panel. 4 Connect Equipment Use 18 gauge, multiconductor, solid thermostat wire to connect the HVAC Outputs along the left side of the Zone Control Board to the HVAC Equipment. Connect R,W,Y,G, O, and C as appropriate to the equipment as if it were a thermostat. 5 Connect Transformer Use 18 gauge - 2 conductor solid wire to connect R and C on the Power Terminal Strip to the mounting screws on the 40VAC self-resetting, plug-in transformer supplied with the Arzel Zoning System. Plug in the transformer to any standard 120VAC receptacle. 6 Test the System 2 Mount Panel Panel must be hung in a non-condensing area where temperatures will not normally exceed 100 o F. DO NOT MOUNT PANEL ON DUCTWORK OR THE HVAC EQUIPMENT. The best method is to attach a piece of 3/4 plywood to the block wall. Hold the panel level to the wall, mark the positions of the upper mounting holes. Drive two screws to the wall leaving the heads at least 1/2 out. Set the panel over the screws. Drive two screws into the lower mounting holes. Tighten the upper screws. 24VAC Transformer Connections 40VA Self-Resetting Transformer Connections R,W,Y,G, O and C as necessary HVAC Equipment Connections Dry Contacts R,W,Y,G, O and C as necessary 4

Wiring Diagrams The following diagrams have been provided for your convenience. They represent the most common installation techniques. If your application does not look like either of these or you need additional help, there are additional diagrams at www.arzelzoning.com or contact technical support at (800) 611-8312. Furnace/AC Zone 1 Zone 2 Zone 3 Furnace/Fan Center 24VAC Transformer 18-5 wire Zone 1 Zone 2 Zone 3 18-4 or 18-5 wire HVAC Outputs 24VAC R W Y G O B C R C ON MPS OFF Pump 1 2 3 + Remote ODT Pump and Solenoid connections (factory installed) Pump Heat Pump with Electric Backup Choose thermostats that energize the O terminal in cooling Zone 1 Zone 2 Zone 3 Heat Pump 18-5 or 18-6 24VAC Transformer wire Reversing Valve Select the HVAC Output O terminal if your reversing valve energizes in cooling, B terminal if it energizes in heating HVAC Outputs 24VAC R W Y G O B C R C ON MPS OFF Zone 1 Zone 2 Zone 3 Pump 1 2 3 + Pump and Solenoid connections (factory installed) Pump 18-5 wire Remote ODT or Outdoor Com N/O SPST Relay Com N/O Load side Coil side E C Connect relay coil to E & C from any single thermostat 5

Circuit Board Layout & Equipment Notes 3 2 1 4 5 6 7 8 LED Display Inset 9 10 11 12 13 11 12 17 16 15 14 10 # Name Description 1 PWR On/ Off w/led 2 24VAC 3 HVAC Output The Arzel System is powered by a 40 VA 24VAC transformer (provided). This switch and the HVAC system equipment power switch must always be in the OFF position when connecting wires to any terminals. (See control panel DANGER SECTION.) The Arzel 40 VA transformer (provided) must be connected to these two terminals. Output to the HVAC equipment is controlled by a set of Dry-Contact Relays. The HVAC R signal is turned around and sent out to start the appropriate equipment when called by the Zone Control. The HVAC Output circuit is therefore completely isolated from the Zone Control and thermostat power supply. R. W. Y. G. O/ B. C. Connect hot or + side of HVAC equipment transformer (24 VAC) to this terminal. Connect to W1 of furnace. (Aux. heat terminal if heat pump is installed.) Connect to compressor contactor. Connect to equipment fan relay. Connect either O or B to heat pump reversing valve, as required by heat pump manufacturer. Use the O signal if the unit reverses in the cooling cycle; the B if it reverses in the heating cycle. Connect common side of HVAC equipment transformer (24 VAC) to this terminal. 4 Connect thermostat wires (R,W,Y,G,O, and C) as required for your application. Note which thermostats are connected to which zones. (24VAC) 5 ODT Emergency Heat Changeover terminals (5VDC) Remote ODT are used for remote switching by outdoor thermostat. This remote switch (or thermostat) will change heat pump operation to backup heat or fossil fuel. If a heat pump is installed with a fossil fuel furnace (without fossil fuel kit) do not connect the (W) wires from the zone thermostats. 6

6 Emer. HT. Switch Emergency Heat Changeover switch, is used to manually bypass the heat pump and energize the auxiliary heat on a call for service (heat pump application only.) 7 Fan-on- Heat Switch This switch in the ON position will provide automatic fan operation on a call for heating, for electric furnaces, hot water coils, steam coils, etc. 8 S1,S2,S3 Solenoid LEDs These LEDs indicate which zones are being served and are opening their dampers. [S1,S2,S3(Red)] 9 Fault Code LEDs F1,F2,F3 The 3 Fault Code LEDs illuminate when a themostat sends an illegal call. A call is illegal if it is improper for the type of HVAC equipment installed. LED will stay lit until the power switch is cycled. F1 = illegal call on zone 1. F2 = illegal call on zone 2. F3 = illegal call on zone 3. Illegal calls are ignored. The system will continue to operate normally, serving any legal calls. Illegal calls may indicate a thermostat or wiring fault in the affected zone. 10 Pump LED LED [PMP (Red)] light is ON anytime the pump is running. 11 Compressor Lock-out LED Any time the zoning system turns the compressor off, it holds it off for four(4) minutes. This prevents short cycling the compressor. 12 TDO Time Delay Override This momentary contact, Time Delay Override switch (TDO), is provided on the PC board to speed the checkout of the zoning system. Before using this TDO switch, you must disconnect the HVAC R wire in order to avoid short cycling the equipment. AComp. Lockout LED light will indicate 4 minute compressor lockout condition. [Comp Lockout(Red)] 13 System Status LEDs The Display Switch controls what information is displayed on the Service LEDs. By default the LEDs indicate the HVAC Output Signal. It will illuminate the Out LED and the appropriate service LEDs to indicate the call to the equipment. 14 Display Button Function Push the button once, and the system illuminates the Zone 1 (Z1) LED and shows what the Zone 1 is calling for. Push it again and The Zone 2 (Z2) LED illuminates and the Display LEDs show what Zone 2 is calling for. Push the button a third time and Zone 3 is displayed. Pushing it a fourth time will return it to the Output display. The system will revert to displaying the Output signal anytime the button is idle for 1 minute. 15 Furnace/ Heat Pump Switch Switch sets the operational mode for the zoning system. that the zoning system is controlling. Set the switch for the type of equipment 16 Solenoid and Pump Factory connection for the Zone Solenoids (24VDC). Solenoids are energized to provide pressure to close the dampers and de-energized to provide vacuum to open the dampers. Factory connections for the pressure/vacuum pump.(24vac) The pump operates only when a thermostat calls for a Heat/Cool or Fan operation or when the MPS switch is in the ON position. 17 MPS Switch MPS switch starts pump and opens all zone dampers when Power Switch is OFF. 7

Commissioning Procedure FAN CHECK-OUT. Set all thermostats to the OFF position and all fan switches to AUTO.. Turn the HVAC system and the Arzel system PWR switches to ON. The LED light next to the switch will illuminate. 3. Turn the Zone 1 thermostat fan switch ON. The S1 indicator, the Fan output (G) and Pump LED lights will illuminate. The fan in the HVAC system will turn on. The pressure and vacuum pump will position all the dampers. Check the air flow at all register outlets to determine that only Zone 1 dampers are open and all other dampers are closed. 4. Follow the above procedure for all other zones HEATING & COOLING CHECK-OUT. Set all thermostats to the OFF position and all fan switches to AUTO before starting heating system check out.. Set Zone 1 thermostat to the HEAT position and turn thermostat up so that the thermostat is calling for heat. The S1 indicator, the W output, and the pump LED lights will illuminate. The pressure/vacuum pump will position all the dampers. Check to see that the heating circuit is energized. If heat pump is installed, check operation of Emergency Back-up heating. Turn the thermostat down until the thermostat is satisfied. The LED lights will go out and the pump will stop. Dampers will remain open in the last zone that called. For heat pump, LED indication will be Y & G. 3. Set thermostat for Zone 1 to the COOL position. Turn thermostat down so that the thermostat is calling for cooling. The S1 indicator, the Y and G output and the pump LED will illuminate. The pressure/vacuum pump will position all the dampers. Check to see that the compressor contactor is energized. For heat pump, LED indication will be Y, G & O. 4. Place Zone 1 thermostat in the OFF position. 5. Follow the above procedure for all other zones. Troubleshooting Matrix Problem Possible Causes Correction No LEDs lit Dampers not opening or closing HVAC system not operating 1- Power Switch OFF 2- No 24VAC from transformer 1- Insufficient Pressure/Vacuum 2- Binding on rectangular duct 1- No equipment control power 2- Output relay failure Turn Power Switch to ON. Check Transformer input/output. Replace if 110V is present w/ no 24vac output. Check for open tube ends or leaky damper actuator. Cut opening to specified dimension per installation manual. Check equipment transformer and/or control wiring Check continuity between R and calling circuit (W,Y,G) at the HVAC Output, if none and the appropriate output LED is lit, replace board. One zone not being served 1- Illegal call at panel 2- Faulty board component Check wiring of thermostat to Panel ( O is energized with cooling call only). If call is legal and no service provided, replace PC board Slave zone not operating No Comon wire from equipment control transformer Connect C from equipment to C of HVAC Output terminals in panel. Low air flow to zones 1- Bypass Damper Open 2- Restriction in system Adjust weight on bypass damper for maximum static to smallest zone. Check filter, DX-coil, or secondary heat exchanger coil for blockage. IF ALL ELSE FAILS... 1. Turn the Arzel power switch to OFF. 2. Disconnect the thermostat wires from any zone and connect them to the HVAC OUTPUT terminals. 3. Turn the MPS switch ON, this will open ALL zone dampers. The HVAC system will work without the benefit of the zoning system. The heating and air conditioning equipment is now controlled by that thermostat. All dampers will stay open. If the HVAC system does not work in this configuration, you probably have a wiring, thermostat or other equipment problem. More tech information is available at: 800-611-8312 and www.arzelzoning.com 8