RCS MODEL ZC2S 2 ZONE HVAC CONTROL UNIT INSTALLATION AND OPERATION MANUAL DCN /25/03

Similar documents
RCS Residential Control Systems Inc.

T8401C Electronic Thermostats

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

RCS Residential Control Systems Inc.

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

LZP-2 ZONE CONTROL PANEL

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE ***

Owner s Manual. Digital Thermostat

Owner s Manual. Digital Thermostat. Non-Programmable

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

T7100D Microelectronic Conventional Thermostat

Installation Instructions

INSTALLATION & OPERATION MANUAL

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

OWNER'S MANUAL T0140. Contents Page #

Small Digital Thermostat Controller Temperature Control

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

ETN-24-HC21-PROG Econo-Vent

T8602C Chronotherm IV Deluxe Programmable Thermostats

Installation Instructions

T7200D,E Series 2000 Commercial Microelectronic Thermostats

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

H32 Uni- Zone Model H32

1F60-22 INSTALLATION & OPERATING MANUAL SETBACK THERMOSTAT. Homeowner: Save this booklet for future use!

Safety & Installation Instructions

Deluxe Programmable Thermostats

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Safety & Installation Instructions

Thermostats... loaded with features, designed for value!

Table 1. Serie of Digital Room Thermostats.

T8600D Chronotherm IV Deluxe Programmable Thermostats

Safety & Installation Instructions

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

T834C Heating-Cooling Thermostat

Model 1750A/ 1770A Dehumidifier Installation Instructions

OWNER S MANUAL. Part Number P CONTENTS

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

ACONT600AF11MA Programmable Comfort Control

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

SmartZone TM System Manual

Owner s Manual. Part Number 33CS250-RC

Installation & Operation Instructions

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Programmable 5-2 Day Digital Thermostat

7-DAY or 5/2-DAY PROGRAMMABLE, OR NON-PROGRAMMABLE THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

7-Day. Digital Thermostat. residential. & 2-cool

CT2800 Programmable Thermostat

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature

T8611M Deluxe Programmable Heat Pump Thermostats

TZ-4 TotalZone Zone Control Panel

Safety & Installation Instructions

Programmable Load Management Thermostat

Owner's Manual TABLE OF CONTENTS

PRO Installation. Thermostat Wi-Fi

heat (2 heat/1 cool).

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Outdoor Reset IQ Option Card, p/n

OWNER S MANUAL. Part Number P RF

TCONT602AF22MA. Programmable Comfort Control. Installation Instructions 18-HD37D1-1

Safety & Installation Instructions

Commercial Touchscreen Thermostat

Outdoor Reset IQ Option Card, p/n

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

CT500 Electronic Thermostat

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

Elegance. SMT-700 User manual. Ver

FAST-STAT Nordic Electronics Ltd

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

peaksaver PLUS Program

T8112C,DElectronic ProgrammableThermostats

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

PECO. WavePRO Wireless System INSTALLATION GUIDE: T2500 THERMOSTAT AND R2500 RECEIVER. The Peco WavePRO Wireless System

T855S. Caution. Page. Table of Contents Table of Contents Thermostat Operation Thermostat Quick Reference Programming Features Warranty Information

Model 17A00 Expansion Enclosure

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

Model GPT 3 Freeze Protection Thermostat

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

Emerson Blue Easy Set 1H/1C

OPERATING MANUAL. Need Help? This manual covers the following models: T915. Table of Contents

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

Home and Building Control Home and Building Control Helping You Control Your World

Transcription:

RCS MODEL ZC2S 2 ZONE HVAC CONTROL UNIT INSTALLATION AND OPERATION MANUAL DCN 11-0020-02 7/2/0

Introduction The ZC2S two zone HVAC Control Unit allows 2 standard electronic thermostats to connect to a single heating and cooling HVAC mechanical system. It provides two independent zones of temperature control by controlling the mechanical system and motorized dampers in each zone. The ZC2S is for use with any residential style standard gas or electric heating HVAC system up to ton capacity. The control unit supports one stage heating and one stage cooling systems. The two zones are truly independent and can be in either heating or cooling modes. The control unit features auto changeover from heating to cooling modes and gives heating calls priority. The ZC2S operation is fully automatic and transparent to the user. Each zone thermostat provides the complete and independent control for that zone. You can think of each zone as having a separate heating/cooling system with its own thermostat. Each zone Thermostat determines the operation of the heating and cooling system so you should refer to your Thermostat Manual for information on how to operate the system. Thermostats for use with the ZC2S The ZC2S works with most ELECTRONIC thermostats (Honeywell, White Rogers, Lux). Use only thermostats that are either battery operated or that use both sides of the 2VAC power (they have R and C terminals) from the HVAC system DO NOT USE POWER STEALING THERMOSTATS! Typically these thermostats steal power from the W or Heat connection on the HVAC system. THESE WILL NOT WORK WITH THE ZC2S ZONE CONTROL UNIT. It is also recommended that you do not use older style mechanical thermostats that use anticipator circuits as these will not function properly. Thermostats connect to the zone control unit terminals the same as they would connect to the HVAC system. Zone Dampers for use with the ZC2S The ZC2S provides independent control of temperature by regulating the flow of conditioned air to the zones by motorized dampers. The system uses two position, on/off control. The controllers are designed to work with normally open, two position, spring return, 2VAC, 2 wire motorized dampers, such as the RCS RD Series of round motorized dampers. These dampers draw.a each. Normally open dampers are used to provide fail-safe operation, assuring condition air will be available even if a damper motor fails. When zone 1 calls for heating or cooling, the zone 2 damper closes. Maximum rated current for all dampers is 1 Amp. ( typically 2 dampers). HVAC Systems Compatibility The ZC2S is designed to work with most standard gas/electric residential style heating and cooling systems and provide the following outputs to the HVAC system. One stage of heating: W output DCN: 11-0020-02 7/0 2

One stage of cooling: Y output Fan: G output The Fan output is selectable for normal gas heating system operation with no fan output with heat calls or for electric heating systems which require fan output with heat calls. The controllers connect to the HVAC systems at their standard thermostat connections and function just like a thermostat to the system. Consult your HVAC thermostat wiring diagram for verification of compatibility with the zone control units. Thermal Equalizer Feature The ZC2S version of the controllers includes the exclusive patented THERMAL EQUALIZER feature. This is used in two story, forced air applications to reduce the effects of heat stratification. Heat rises naturally and during heating cycles the upstairs zone tends to overheat. This loss of heat to the upstairs keeps the downstairs zone cooler and calling for more heat. This process continues until the upstairs is uncomfortably hot and the downstairs is still calling for more heat. To balance this natural phenomena, the THERMAL EQUALIZER feature will monitor the length of time the heat has been calling downstairs and after a selectable time period, will stop the heat call and recycle the overheated upstairs air back down to the downstairs zone. This equalizer cycle will reduce the heat buildup upstairs and put the heat back downstairs where it is still needed. The net effect is a more comfortable temperature in the upstairs zone and an energy saving reuse of the excess heat in the downstairs zone. The Thermal Equalizer feature monitors Zone 1 for heat run times and this zone must be the downstairs zone. When the Thermal Equalizer cycle is on, the Zone 2 damper will be closed and the high speed fan turned on. Zone 2 must be the upstairs zone when using the Thermal Equalizer feature. Short Cycle Protection Delay The ZC2S control unit provide a minute delay between successive compressor operations for short cycle protection. This delays one zone from calling for compressor operation shortly after another has stopped and prevents potential damage to the compressor due to rapid off-on cycling. Most thermostats also have built-in short cycle protection delays, so remember these compressor cycle delays are normal when trouble shooting the system. For testing purposes, you can reset the controller s min delay by removing power from the controller. Status Led The status LED will flash one time every second for normal operation. During certain other modes of operation the LED will flash differently to indication these modes. See table below. LED Flash Modes One Flash Normal Operation Two Flashes Equalizer Cycle On Three Flashes Short Cycle Protection Delay On. (Compressor output inhibited) DCN: 11-0020-02 7/0

Installation Install the controller near the HVAC mechanical system or in a convenient indoor service location, such as the garage, basement, closet or utility room. Mount the controller to the wall or structural bracing. Mounting the controller onto the HVAC unit is possible but generally not desirable due to the potential for excessive vibration and heat. Wiring Thermostats. Use standard 18GA thermostat wiring to connect the thermostats to the controller and the controller to the mechanical system. Dampers. Zone damper outputs provide 2VAC at 1 Amp maximum to the dampers. Use 18 gauge thermostat wire for the dampers. Power ZC2S Control Units are powered from the HVAC system s 2VAC R and C (common) terminals. No external transformer is required. Total damper draw must be limited to 1 Amp per zone. Fuse The controller is supplied with a 2AG style 2 Amp fuse. Thermostat Wiring Connect the zone thermostats to their respective zone input terminals, J1 & J2. Both the 2VAC Common (C) and 2VAC (R) power is available at these terminals. Only the 2VAC (R) terminal is required for proper input from the thermostats. The 2VAC Common (C) is provided for thermostats that require power from the system. ZONE 1 THERMOSTAT 2VAC COM C 2VAC R OPTIONAL FOR POWER IF REQUIRED ZC2S CONTROL UNIT ZONE 1 INPUT FIG 1. WIRING THERMOSTATS TO THE CONTROLLER DCN: 11-0020-02 7/0

HVAC System Wiring The ZC2S control units connect to the HVAC mechanical systems at the normal thermostat connections on the HVAC indoor units. WIRING FOR STANDARD HVAC SYSTEMS HVAC SYSTEM R 2VAC RED GREEN WHITE YELLOW C 2VAC COM R 2VAC RESSOR C 2VAC COM ZONE CONTROL UNIT Standard Thermostat Wiring Color Codes INDOOR FURNACE UNIT OUTDOOR UNIT COMPRESSOR FIG 2. WIRING ZONE CONTROL UNIT TO STANDARD HVAC SYSTEM Control Unit Setup: Dipswitch Settings The control unit has a configuration dipswitch,. Set the dipswitch as follows. Position 1: Test Mode (For service technician use only, do not run in test mode) Select OFF for Normal operation. All delays normal. Select ON for Test mode to reduce delays to 10 seconds and shorten run times to one minute to facilitate system checkout and troubleshooting. Position 2: Fan Mode Select Select OFF for Standard Gas systems (no fan with heat calls) Select ON for Electric Heating systems (fan with heat calls) Position & : Thermal Equalizer Mode Select These two dipswitch positions determine the length of time the equalizer cycle will run after it has been tripped on by the Heat Run Time timeout. ERT1 ERT2 Off: Equalizer feature Off. Off FIG. DIPSWITCH EQUALIZER RUN TIME SETTINGS On Equalizer run time Min Off Off Equalizer run time 8 Min On On Equalizer run time 10 Min On OFF ON DCN: 11-0020-02 7/0

Positions & : Thermal Equalizer Heat Run Time Mode Select These two dipswitch positions determine the length of time that a Zone 1 Heat Call can be on before it times out and is interrupted by an equalizer cycle. FIG. DIPSWITCH EQUALIZER HEAT RUN TIME SETTINGS HRT1 HRT2 Off Heat Run Time 8 Min Off On Heat Run Time 12 Min Off Off Heat Run Time 1 Min On On Heat Run Time 20 Min On OFF ON DCN: 11-0020-02 7/0

RCS WIRING DIAGRAM For Standard Thermostats For Standard HVAC Systems One Stage Heat, One Stage Cool Thermal Equalizer Feature 2 ZONE HVAC CONTROLLER MODEL: ZC2S PN: 001-0020 REV E FUSE Standard Thermostats 7 OPTIONAL POWER TO STATS NORMAL1 STD FAN 2 EQ OFF ZONE 1 OFF - ON TEST MODE F/HEAT ERT1 ERT2 HRT1 HRT2 RESET STATUS LED 1 FLASH = OK 2 FLASH = EQ ON FLASH = SCP ON FAN HEAT 2AG 2A HVAC SYSTEM OM R 2V Standard HVAC System C OM R 2V Outdoor Compressor C Y ZONE2 COMP DAMPERS 7 ZONE1 ZONE2 Zone 1 Com Zone 2 Com ZC2S REV E Motorized Dampers Normally Open 2VAC Two Position Spring Return STATUS LED: The status LED shows normal operation by flashing slowly. If the Status LED is not flashing, check power/fuse. Two flashes indicate that the Equalizer run cycle is on. Three flashes indicate that the Short cycle protection is on. SHORT CYCLE PROTECTION (SCP) DELAY. The control unit protects the compressor from short cycling by a minute delay at the end DIP of SWITCH every compressor SETTINGS run cycle. The Status LED will flash rapidly three times to indicate SCP delay is active. Dipswitch Settings: -1 TEST MODE -2 FAN MODE SELECT 1 OFF = NORMAL OPERATION 2 OFF = Gas Systems. NO fan w/heat 1 ON = TEST MODE- ALL DELAYS CANCELED 2 ON = Electric Systems. Fan w/heat - & EQUALIZER MODE SELECTION - & HEAT RUN TIME SELECTION Equalizer OFF Equalizer Run Time = Min Equalizer Run Time = 8 Min Equalizer Run Time = 10 Min Heat Run Time = 8 Min Heat Run Time = 12 Min Heat Run Time = 1 Min Heat Run Time = 20 Min Note: There is a 2 Min Minimum Heat Run Time (MHRT). If the Heat Call is terminated during this period, no Equalizer cycle will be started at the end of the call. If the Heat Call last longer than the MHRT, but less than 8 Min, then an Equalizer cycle will be started at the end of the call. DCN: 11-0020-02 7/0 7