The house has 4 inches of exterior foam board (in two layers) and 2 inches closed cell spray foam with cellulose in the wall cavities.

Similar documents
The owner has future plans to install a photovoltaic array on the house.

The Lara. Site Contact. Summary. 113 Nassau Site Information. 113 Nassau Street New York, NY 10038

MEASURED PERFORMANCE DATA FOR

Heat Pump Water Heaters: Laboratory and Field Evaluation of New Residential Products

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

Appendix A Equipment Used to Monitor Hotels

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Building America Special Research Project: Space Conditioning Systems for High Performance Homes

SOLAR THERMAL HEATING: ALIVE AND WELL

BOILERS. Air Vent. Supply. Drain Valve

Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

DRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Southern California Gas Company Customer Programs Department

Sensor Selection Guide. Sensing for Building Applications

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Energy Options for Residential Heating. Juergen Korn, P.Eng.

EL-OEM-3 OEM Packaged Voltage Data Logger

SECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN

EL-USB-TC Thermocouple Data Logger with USB Interface

Zehnder Rittling Corporate Headquarters and Manufacturing Facility

Contacting Onset Mailing Address: Phone: Fax: Hours of Operation: E mail: Main Onset Web site: Copyrights and Trademarks

Evaluating Domestic Water Heater Performance for NY Homes NYSERDA Agreement 15606


Accessories, interfaces, sensors and complete solutions.

OG-300 Internal Coil Solar Hot Water Systems Schematics and Parts Lists

Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

Single Dwelling Unit Hot Water System Distribution Project Name: Enforcement Agency: Permit Number:

Thermostatic Radiator Valves (Caleffi)

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

EL-USB-1-LCD Temperature Data Logger with LCD

Reference Guide REFRIGERATION INFORMATION

Geothermal Case Study

EL-USB-1-LCD Temperature Data Logger with LCD

Energy Consumption and User Comfort In Cold Climate NZEHs

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

Riverdale NetZero Project Summary of Costs and Expected Performance

Food Service Technology Center

Food Service Technology Center

Zero Energy Home Design Project

Split Type System. Air to Water Heat Pump

Hot Food Holding Cabinets Test for FWE HLC

Hot Water. The Efficiency Challenge!

Tepid Water Delivery System

Trade Product List 2013 BIOMASS ACCESSORIES

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

ELMTEC. Kattreppeln Königslutter / /

Food Service Technology Center

LOW COST FOOD STORAGE TECHNOLOGY: ENERGY SAVINGS AND PRODUCE STORAGE QUALITY. Ben Weil Luke Doody University of Massachusetts Amherst

Hydronic & HVAC Control Systems

Technical Criteria for District Energy Ready Buildings Master Requirement ENG 108 Building Department: ,

7. MECHANICAL SYSTEM DESIGN

Electronic timeswitch

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

Heat Transfer Packages

Specifications Minimum Typical Maximum Unit

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

Energy Efficiency Demonstration Residential Ductless Heat Pumps (DHP) Overview. Ammi Amarnath Chris Trueblood

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

IT WON T JUST MEET YOUR HOT WATER NEEDS.

PROGRESSIVTUBE PASSIVE SOLAR WATER HEATING SYSTEM

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings

Raptor 320HB & 399HB Submittal Sheet

SBB 300, 400 S & Sbb 300, 400, 600 Plus

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Utica H 2 O. There Are Some Things You Can Always Depend On...

HOBOlink. Printable Help

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

BrHEAThe motivation, history, and evaluation

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Model CS Hour Fuel Temperature Stick Revision: 5/08

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION

Better Buildings By Design What are the best HVAC solutions for low-load, high performance homes? February 6-7, 2013

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Monitoring Field Performance of Residential Geothermal Heat Pumps

Thermal Shock Chamber TSE 11

HOBO U30 Remote Monitoring Systems

Mul$family Buildings: Real World Monitored Data on Hot Water Energy and Water Use

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

MBPA Home Performance FIELD DATA COLLECTION FORM

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Better Design, Better Control, Better Systems.

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

Home Energy Assessment Report

Sanden SANCO₂ Heat Pump Water Heater. Technical Information

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Instantaneous Water Heaters

Transcription:

Monitoring Plan for TED House The 1200 sq ft TED House has radiant floor heating with a 96.5% gas-fired Rinnai E75CN water heater. The Rinnai unit has a separate water circuit to provide space heating. A Fantech HRV will provide balanced ventilation for the house. The house does not have a cooling system installed. The house has 4 inches of exterior foam board (in two layers) and 2 inches closed cell spray foam with cellulose in the wall cavities. Monitoring Approach A data acquisition system will be installed to monitor the energy performance of the house and its mechanical systems. The system will be mounted in a 16 in x 18 in enclosure mounted on the wall near the boiler (on the plywood). The system will be based around a Campbell Scientific CR1000 data logger. Data will be collected at 15-minute intervals. Our first choice for communications would be to plug into the home owners Ethernet router in order to go out to internet. Alternatively we could use a phone line. CDH Energy Corp. 1 November 2010

The proposed data points are shown in Table 1 and Figure 2. The monitoring points were selected to: Measure total house electric use (WTI) to quantify internal house loads and submeter other selected electrical loads (WA1) Measure boiler fuel use (FG) to fuel use patterns as well as boiler system (unit and pump) power (WB), Measure the thermal output of the boiler to the floor (FR, TFS, TFR) to determine boiler efficiency and heating loads as a function of loading and supply temperature, Measure domestic hot water (DHW) water use and thermal output (FHW, THWO, THWI) to quantify loading patterns and hot water use, Measure the operating status the heating zone pumps (SP1, SP2) in order to understand and quantify the operating patterns of the system. Measure the inlet and outlet conditions from the ventilation system (e.g., HRV) (TAI, RHI, TAO, TAS) to confirm operation, detect defrost patterns (IFV), quantify heat recovery performance. SP1,2 Natural Gas FG FR Rinnai THWI FHW THWO Cold Water Hot Water Main Breaker Box WTI, WTE, WB Radiant Floor Circuits TFS TFR Indoor Air Supply Air TAI RHI TAS HRV IFV Ceiling Outlet Exh Air TAO Outdoor Air Figure 1. Schematic of Heating and Ventilation System with Data Points Shown CDH Energy Corp. 2 November 2010

Table 1. List of Measured Data Points Channel Data Point Description Eng Units Instrument / Transducer Range SE1 TFS Floor HW Supply Temperature F Type-T Thermocouple n/a SE2 TFR Floor HW Return Temperature F Type-T Thermocouple n/a SE3 (empty) TBS Boiler Supply Temperature F Type-T Thermocouple n/a SE4 TAS HRV Supply Temperature F Type-T Thermocouple n/a SE5 TAO Outdoor Temperature (in HRV) F Type-T Thermocouple n/a SE6 TAI Space Temp (in HRV) F Type-T Thermocouple n/a SE7 THWO DHW Outlet Temperature F Type-T Thermocouple n/a SE8 THWI DHW Inlet Temperature F Type-T Thermocouple n/a SE9 IFV HRV Fan Current (dmpr pos) amps Veris 921 Current Sensor 0-30 A SE10 RHI Space RH (in HRV) % Vaisala RH Transducer 0-100% RH SE13 SP1 Floor Pump 1 min Veris 300 Current Switch n/a SE14 SP2 Floor Pump 2 min Veris 300 Current Switch n/a P1 FR Flow Rate to Radiant Floor gpm Onicon F1300, 3/4 in n/a P2 FHW Hot Water Flow Rate gal Omega FTB 4607 n/a C1 FG Boiler System Gas Consumption CF AM250 Gas Meter with Pulse n/a C2 WTI Total House Power (import) kwh Wattnote WNB-208 (P1) n/a C3 WTE Total House Power (export) kwh Wattnote WNB-208 (P2) n/a C4 WB Boiler Power (and pumps) kwh Wattnote WNB-208 Option 3 (P1) n/a C5 (empty) WA1 Additional Power Monitor 1 kwh Wattnote WNB-208 Option 3 (P2) n/a CDH Energy Corp. 3 November 2010

Figure 2. Rinnai Boiler/Water Heater During Construction TAO CDH Energy Corp. 4 November 2010

WTI WTE WB Extension breaker panel located on the wall by the boiler, wattnode panel located beneath. SP SP CDH Energy Corp. 5 November 2010

CT measuring HRV power located above the main breaker box. CR 1000 located below the TACO panel and to the lower left of the extension breaker box. Verification: Total house power (WTI) Fluke 39 reading 222W Pulse count per 2 min 3 CDH Energy Corp. 6 November 2010

Power used 225 Notes: 2.5Wh/pulse (from manual) Boiler Power (WB) Fluke 39 reading 270W Pulse count per min 37 Power used 277.5 Notes: 0.25 Wh/pulse (from manual) Wire looped through CT twice Sensor R(ohms) output Range (ma) Sensor Range Mult Offset IFV 120 4 20 0 30 0.015625-7.5 RHI 120 4 20 0 100 0.0520833-25 HRV Fan Current (IFV) measurements: Off On Difference Veris (amps) -0.0514 1.71 1.7614 Fluke 39 (amps) 0.07 1.84 1.77 Flow Rate to Radiant Floor (FR): 2x pumps 6.0029 gal/min 1x pump 3.165 gal/min 0x pumps 0 gal/min Notes: from counting FR acc in data monitor window from multiplying instantaneous g/s by 60s CDH Energy Corp. 7 November 2010