Centrifugal inline fans

Similar documents
USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

CENTRIFUGAL CEILING EXTRACT FAN

Air handling unit. BlauAir RH USER S MANUAL

CENTRIFUGAL CEILING EXTRACT FAN

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

USER S MANUAL DN-2. Drain pump

USER S MANUAL. VKP Series INLINE FAN

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

AXIAL FANS USER S MANUAL

HEAT RECOVERY VENTILATOR

Axial intelligent fan USER S MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

AIR HANDLING UNIT WITH HEAT RECOVERY

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

CENTRIFUGAL FANS user's manual. model VENTS VK.

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

HEAT RECOVERY AIR HANDLING UNIT

Installation manual Mini Comfort 50 S/L 07/ V EN

AXIAL FANS user's manual. model Quiet

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

Turbo. Service Instructions

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

INTELLIGENT AXIAL FAN user's manual

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Wind. Service instruction

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

USER'S MANUAL PS

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Calm. Service Instructions

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

USER S MANUAL UET CONTROL UNIT FOR THE AIR HEATING UNIT WITH ELECTRIC HEATER AOE SERIES

Aero. Service Instructions

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

Homeowner s Installation Instructions & Operating Manual

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

AH-600 Baseboard Heater

HEAT RECOVERY AIR HANDLING UNITS

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

ELECTRIC STOVE HEATER Models: FS2213B

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Electric Garage Heater

Homeowner s Installation Instructions & Operating Manual

Gallery Electric Fireplaces

23-IN Electric Logset

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

Low Profile. Baseboard Heater

Owner s Manual Window Air Conditioner

NO VENTING REQUIRED 120V AC;

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

IMPORTANT INSTRUCTIONS READ & SAVE

PANEL HEATERS OPERATING INSTRUCTIONS

Sensor Control Panel

The Family Ceramic Heater

40 Built-in Electric Fireplace Operating and Installation Instructions

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

ELECTRIC FIREPLACE OWNER S MANUAL

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Turbo Inline Fan, White - Non Illuminated Art no.33500

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

COMBINATION ELECTRIC FIREPLACE/HEATER Model #FP23-1A-AKM

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

MILLA ELECTRIC FIREPLACE

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

PROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

FLCH4R Garage and Utility Electric Heater

Up to 60 Pint Commercial Grade DEHUMIDIFIER

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

BLAUAIR AUTOMATIC CONTROL SYSTEM

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

White - Non Illuminated Art no White - Cool White LED Art no.32600

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

General Care and Safety Guide

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Gallery Electric Fireplaces

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

2000 WATT CYCLONIC BAGLESS VACUUM CLEANER

Wall Hanging Mode. Pedestal Mode

Transcription:

USER S MANUAL VKM 100 Q VKM 100 VKM 125 Q VKM 125 VKM 150 E VKM 150 VKMS 150 VKM 160 VKMS 160 VKM 200 VKMS 200 VKM 250 E VKM 250 VKM 315 VKMS 315 VKM 355 Q VKM 400 VKM 450 Centrifugal inline fans

VKM CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design and operating principle... 6 Installation and set-up... 6 Connection to power mains... 7 Control... 8 Technical maintenance... 8 Possible malfunctions and troubleshooting... 9 Storage and transportation regulations... 9 Manufacturer s warranty... 10 Certificate of acceptance... 11 Seller information... 11 Installation certificate... 11 Warranty card... 11 This user s manual is the primary operating document intended for technical, maintenance and operations staff. The user s manual contains information regarding the field of application, delivery package, operating principle, and design of the VKM fan and all its modifications. Technical and maintenance staff must have proper theoretical knowledge and practical training specific to ventilation systems as well as the necessary skills to carry out the work in accordance with labour safety and construction regulations and standards applicable in the respective territory. The information provided in the present document is true as at the document preparation. Due to the continuous product development the company reserves the right to update the technical specifications, design or delivery package of its products. No part of the present publication may be reproduced, uploaded or saved in reference-providing information systems or translated into other languages in any form whatsoever without the company s prior written consent. SAFETY REQUIREMENTS Please read the user s manual carefully prior to installing and operating the unit. All user s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical norms and standards must be observed when installing and operating the unit. The warnings contained in the user s manual must be considered most seriously since they contain vital personal safety information. Failure to follow the rules and safety precautions noted in this user s manual may result in an injury or unit damage. After a careful reading of the manual, keep it for the entire service life of the unit. While transferring the unit control, the user s manual must be turned over to the receiving operator. UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any installation operations. Unpack the unit with care. The unit must be grounded! While installing the unit, follow the safety regulations specific to the use of electric tools. 2

Do not change the power cable length at your own discretion. Do not bend the power cable. Avoid damaging the power cable. Do not put any foreign objects on the power cable. Do not use damaged equipment or cables when connecting the unit to power mains. Do not lay the power cable of the unit in close proximity to heating equipment. Do not operate the unit outside the temperature range stated in the user s manual. Do not operate the unit in aggressive or explosive environments. Do not touch the unit controls with wet hands. Do not carry out the installation and maintenance operations with wet hands. Do not wash the unit with water. Protect the electric parts of the unit against ingress of water. Do not allow children to operate the unit. Disconnect the unit from power mains prior to any technical maintenance. Do not store any explosive or highly flammable substances in close proximity to the unit. When the unit generates unusual sounds, odour, or emits smoke, disconnect it from power supply and contact the Seller. Do not open the unit during operation. Do not direct the air flow produced by the unit towards open flame or ignition sources. Do not block the air duct when the unit is switched on. In case of continuous operation of the unit, periodically check the security of mounting. Do not sit on the unit and avoid placing foreign objects on it. Use the unit only for its intended purpose. THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE. DO NOT DISPOSE THE UNIT AS UNSORTED MUNICIPAL WASTE. 3

VKM PURPOSE The VENTS VKM centrifugal fans are designed for ventilation of domestic, public and manufacturing premises heated during winter. The transported air temperature must be within the limits stated in the «Technical data» section. THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT THE APPROPRIATE TRAINING. THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING. THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN. THE UNIT MUST NOT BE OPERATED IN KITCHEN PREMISES. The fan is designed for horizontal or vertical mounting in an air duct and is used both for supply and exhaust ventilation. Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, pathogenic germs). DELIVERY SET NAME Fan Outer mounting bracket for VKM fans Outer mounting bracket for VKM E fans User's manual Packing box NUMBER 1 pc. 2 pcs. 1 pc. 1 pc. 1 pc. DESIGNATION KEY VKM S X X Additional options Q equipped with a low-watt motor E equipped with an energy-saving motor Un speed controller and temperature controller P speed controller R power cord with an electric plug Exhaust spigot diameter Increased capacity Fan series VKM centrifugal inline fan 4

Permitted deviation of mains voltage: ±10 % of the rated voltage. The fan must be grounded. Ingress protection rating against access to hazardous parts and water ingress is IPX4. TECHNICAL DATA Air capacity [m Power [W] Current [A] /h], RPM[min Fan model Voltage [V] max. Noise level at 3 m Transported air ] [dba] temperature [ C] 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz VKM 100 Q 45 50 0.24 0.23 233 267 2780 3300 38 39 VKM 100 60 82 0.28 0.36 279 278 2840 3320 40 41 VKM 125 Q 47 54 0.25 0.24 326 370 2760 3240 37 38 VKM 125 64 85 0.29 0.37 360 357 2840 3300 40 42 VKM 150 E 63 81 0.26 0.28 435 455 2830 2840 40 40 VKM 150 91 134 0.42 0.60 540 560 2770 3125 45 46 VKMS 150 119 165 0.52 0.73 650 680 2820 3250 48 49 VKM 160 99 137 0.44 0.61 567 575 2770 3160 45 47 VKMS 160 1~230 121 170 0.53 0.75 690 730 2800 3210 48 49-25 +45 VKM 200 135 182 0.59 0.79 1070 1220 2710 3120 48 50 VKMS 200 193 240 0.59 1.05 1150 1200 2780 2850 49 49 VKM 250 E 95-0.47-900 - 2050-47 - VKM 250 194 240 0.85 1.05 1420 1520 2790 2860 50 51 VKM 315 171 241 0.77 1.05 1440 1550 2600 2850 52 53 VKMS 315 295 413 1.34 1.8 1920 1980 2720 2780 54 55 VKM 355 Q 233 297 1.06 1.30 2250 2350 1375 1620 58 59 VKM 400 460 673 2.23 3.05 3090 3500 1370 1585 61 64-40 +80-40 +70 VKM 450 665 1250 2.89 5.40 5300 6280 1265 1560 65 73-40 +55-25 +60 The unit design is constantly being improved, thus some models, their wiring diagrams and terminal symbols may be slightly different from those described in this manual. OVERALL AND CONNECTING DIMENSIONS VKM 100-315 VKM 355-450 Model Dimensions [mm] D D1 B B1 L L1 L2 L3 Weight [kg] VKM 100 Q 98 255 310 270 205 20 25 30 2.9 VKM 100 98 255 310 270 205 20 25 30 3.2 VKM 125 Q 123 255 310 270 205 20 25 30 2.9 VKM 125 123 255 310 270 205 20 25 30 3.2 VKM 150 E 148 305 360 320 200 20 25 30 4.25 VKM 150 149 305 360 320 220 25 25 30 5.0 VKMS 150 148 340 390 350 245 20 20 40 6.4 VKM 160 159 305 360 320 220 25 25 30 5.0 VKMS 160 158 340 390 350 245 25 25 40 6.4 VKM 200 198 345 395 355 255 25 30 40 6.6 VKMS 200 198 345 395 355 255 25 30 40 8.3 VKM 250 E 248 345 395 355 250 25 30 40 6.2 VKM 250 248 345 395 355 250 25 30 40 8.4 VKM 315 314 405 455 415 260 30 30 40 8.0 VKMS 315 314 405 455 415 290 30 30 40 8.8 VKM 355 Q 353 460 522 522 506 60 60 70 18.8 VKM 400 398 570 663 634 570 60 60 70 25.1 VKM 450 448 608 700 670 644 60 60 80 27.26 5

VKM DESIGN AND OPERATING PRINCIPLE The fan consists of the casing 1, the electric motor attached to the inner fixing bracket 4, the cover 2 that is fixed to the casing with screws 3 (the casing spigot diameter and the cover diameter are equal to the connected air duct diameter), the terminal box 5 that incorporates a terminal block and a capacitor and enables connection of the fan to single-phase power mains. The fan models with a temperature and speed controller are equipped with a speed control knob 9, a thermostat control knob 10, a fan on/off LED light indicator 11 and a thermostat LED light indicator 12 that are located on the terminal box cover. The fan models with the speed controller are equipped with a speed control knob 9 which is located on the terminal box 5 cover. The fan models with a speed controller or with a speed and temperature controller are connected to power mains through a power cable with a plug. VKM Un 11 12 9 5 1 3 2 10 VKM P 9 8 7 6 4 Fig. 1 6 outer fixing bracket 7 screws 8 bolt 9 control knob of fan impeller rotation speed 10 thermostat control knob 11 fan on/off LED light indicator 12 thermostat LED light indicator INSTALLATION AND SET-UP READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT The fans are designed for vertical or horizontal mounting. Air motion in the system must be in compliance with the direction of the arrow on the fan casing. Install a hood on outlet (discharge) spigot side in case of the vertical fan installation. Provide a straight air duct section at least 1 m long on the intake spigot side in case of horizontal fan installation with maximum allowable humidity. Mounting sequence: Remove the bolt from the casing 1 and install the fixing brackets in such a way so that the holes on the fixing brackets are aligned with the heads of the screws 3. Fix the fixing brackets on the casing with bolts. Drill the holes in the mounting surface to match the fitment holes of the fixing brackets. Fix the fan with the screws. m 6

CONNECTION TO POWER MAINS DISCONNECT THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT. CONNECTION OF THE UNIT TO POWER MAINS IS ALLOWED BY A QUALIFIED ELECTRICIAN WITH A WORK PERMIT FOR THE ELECTRIC UNITS UP TO 1000 V AFTER CAREFUL READING OF THE PRESENT USER S MANUAL. THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE GIVEN ON THE MANUFACTURER S LABEL. ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED AND WILL VOID THE WARRANTY. The fan is designed for 230 V/50 (60) Hz single-phase alternating current mains. The fan shall be connected to power supply by means of insulated, durable and thermal-resistant cords (cables, wires) through the external circuit breaker with a thermal-magnetic trip built into the stationary wiring to disconnect all the power mains phases. The rated current must be not below the rated current consumption (refer to the «Technical data» section). The QF external switch location must ensure free access for quick shutdown of the fan. The recommended rated current of the circuit breaker: 2 A for the VKM 355 Q fans 3.15 A for the VKM 400, VKM 450 fans 1 A for all other fans The recommended wire cross section is minimum 0.75 mm 2. The actual conductor cross-section selection must be based on its type, maximum permissible heating, insulation, length and installation method (in the air, pipes or inside walls). Connect the cables to the terminal block incorporated inside the terminal box located on the fan casing in compliance with the fan wiring diagram and the terminal designation. The terminal designations are shown on the sticker inside the fan casing. The wiring diagram for the VKM 400, VKM 450 fans is shown in Fig. 2. The wiring diagram for the other fans is shown in Fig. 3. The fans with a speed controller and temperature and speed controller (VKM Un) are designed for connection to single-phase AC power mains 230 V/50 (60) Hz and are equipped with a power cord and a plug (supplied connected to the terminal block). ~ 230 V 50 Hz ~ 230 V 50 Hz Fig. 2 Fig. 3 The TW1, TW2 terminals are the electrical leads of the normally closed contact of the motor overheating protection. Connect the contact in series to power circuit of the magnetic starter coil KM1 that starts the motor after pressing the S1 button. In case of pressing the S2 button or motor overheating, the contact gets broken and switches the starter coil off to cut power off and stop the motor. The QF circuit breaker, the magnetic starter KM1, the control knobs S1 and S2 are not included in the delivery and must be installed by the user. The motor connection example with thermal protecting contacts leaded outside are shown in Fig. 4. 7

VKM ~ 230 V 50 Hz Fig. 4 CONTROL The VKM P fans with a built-in electronic module The electronic module is designed for smooth control of fan impeller rotation speed (air flow). The speed is controlled with the speed control knob 9 (Fig. 1). The VKM Un fans with a temperature and speed controller (see Fig. 1). The controller is designed for air temperature control and fan speed control depending on ambient air temperature 10. The speed is controlled with the speed control knob 9 and the temperature control knob 10. The VKM Un fans are equipped with an external temperature sensor fixed on a 4 m cable. The cover of the terminal box incorporates the following controls: fan speed control knob 9 thermostat control knob 10 to set the thermostat temperature threshold on/off LED light indicator 11 thermostat LED light indicator 12 Operation algorithm of VKM Un fans Set the thermostat temperature threshold with a thermostat control knob 10. Switch on the fan, then set the fan speed with the speed control knob 9. The fan on/off light indicator 11 lights up. The controller switches the fan to the maximum speed (maximum air flow) as the temperature rises and crosses the thermostat setpoint. The thermostat light indicator 12 glows if the temperature is above the thermostat setpoint. If the temperature falls 2 C below the thermostat setpoint, the fan reverts to the preset lower speed. This prevents frequent speed changeovers during operation with the temperature close to the threshold value. This control logic enables tracking temperature fluctuations and respond to the temperature change with accuracy up to 2 C. The rate of the speed switching depends exclusively on the air temperature fluctuations. TECHNICAL MAINTENANCE DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! The technical maintenance includes periodic cleaning of the surfaces from accumulated dust and dirt. Use a soft dry brush or a vacuum cleaner to remove dust. The impeller blades require thorough cleaning once in 6 months. To do this, unscrew the self-tapping screws 3 and remove the cover 2 (Fig. 1). Clean the impeller blades with a soft cloth wetted in mild water detergent solution. Avoid liquid dripping on the motor. 8

POSSIBLE MALFUNCTIONS AND TROUBLESHOOTING PROBLEM POSSIBLE REASONS TROUBLESHOOTING When switching on the unit the fan does not start. Circuit breaker tripping during the fan start. Low air flow. No power supply. Motor jamming. The automatic circuit breaker is triggered by an abnormally high current consumption due to a short circuit. Clogging of air ducts or other ventilation system elements. Impeller clogging. Damaged air ducts. Air damper closure. Check the electrical connections and the power switch status. Turn off the fan. Troubleshoot the impeller jamming. Restart the fan. Disconnect the fan from power mains and contact the Seller. Do not turn on the fan again! Clean the air ducts and other ventilation system elements as well as the impeller. Check the air ducts for damage. Make sure the air dampers and louvre shutters are open. STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature range from +5 С up to +40 С and relative humidity up to 70 %. Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation, and sealing deformation. Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit. Follow the handling requirements applicable for the particular type of cargo. The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage. The unit must be transported only in the working position. Avoid sharp blows, scratches, or rough handling during loading and unloading. Prior to the initial power-up after transportation at low temperatures allow the unit to warm up at room temperature for at least 3-4 hours. 9

VKM MANUFACTURER S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/ EU and CE-marking Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above. The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component. The warranty repair does not include: routine technical maintenance unit installation/dismantling unit setup To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment paperwork certifying the purchase. The unit model must comply with the one stated in the user s manual. Contact the Seller for warranty service. The manufacturer s warranty does not apply to the following cases: User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user. Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual. User s failure to ensure timely technical maintenance of the unit. External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user. Redesign or engineering changes to the unit. Replacement and use of any assemblies, parts and components not approved by the manufacturer. Unit misuse. Violation of the unit installation regulations by the user. Violation of the unit control regulations by the user. Unit connection to power mains with a voltage different from the one stated in the user's manual. Unit breakdown due to voltage surges in power mains. Discretionary repair of the unit by the user. Unit repair by any persons without the manufacturer s authorization. Expiration of the unit warranty period. Violation of the unit transportation regulations by the user. Violation of the unit storage regulations by the user. Wrongful actions against the unit committed by third parties. Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades). Missing seals if provided by the user s manual. Failure to submit the user s manual with the unit purchase date stamp. Missing payment paperwork certifying the unit purchase. FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE-FREE OPERATION OF THE UNIT. USER S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER S MANUAL WITH THE PURCHASE DATE STAMP. 10

Certificate of acceptance Unit Type Model Serial Number Manufacture Date Centrifugal inline fan VKM Quality Inspector s Stamp Seller Seller information Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user s manual. The warranty terms are acknowledged and accepted. Customer s Signature Seller s Stamp Installation certificate The VKM unit has been connected to power mains pursuant to the requirements stated in the present user s manual. Seller Address Phone Number Installation Technician s Full Name Installation Date: Signature: The unit has been installed in accordance with the provisions of all the applicable local and national construction, electrical and technical codes and standards. The unit operates normally as intended by the manufacturer. Installation Company Stamp Signature: Warranty card Unit Type Model Serial Number Manufacture Date Purchase Date Warranty Period Centrifugal inline fan VKM Seller Seller s Stamp 11

V05EN-08