INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

Temperature Controllers

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Instruction Manual Model A

UDC100 Universal Digital Controller Specifications

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

Instruction Manual August sitrans CU 02

Water Detection Controllers

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

I/A Series 716C 1/16 DIN Temperature Controller

DTM Distributed Transmitter-Monitor

ph COOLING TOWER CONTROLLER

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

INTRODUCTION / TABLE OF CONTENTS

Alarm Modules Section E

Instruction Manual December 2001 ENACOCU02

108A OTP1800. Grid Support. General Description

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

EUROTHERM ONTROLS. Alarm Unit FULLY COMPLIANT. Product data

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

Process Alarm Module RTA 421

DICTATOR Hold-Open Systems for Hazardous Areas

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Series Temperature Controller Instruction Sheet

Pump-Up Controller MODEL 4062

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

7EF/7HF/7EC/7ES Temperature Controllers

Operating Instructions. For. Alarm Control Module. Model SSR 500

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

Pump-Down Controller MODEL 4052

Series DH3 Digihelic Differential Pressure Controller

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series DH3 Digihelic Differential Pressure Controller.

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

UDC 700 Universal Digital Controllers and Indicator Specifications

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Electronic Flow Switches

Series EDA Electronic Pressure Controller. Specifications - Installation and Operating Instructions

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

02/11/2015

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

LOVE. INSTRUCTIONS FOR THE Panel Pro 45, 4 3 /4 DIGIT MICROPROCESSOR BASED TEMPERATURE / PROCESS INDICATOR LOVE CONTROLS

Series EDA Electronic Pressure Controller

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

ANEMOMETER 4403-RF-BAT

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

F4 Process Controller Installation and Operation Guide

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

CU-02 with Senaco Plus

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

INSTALLATION INSTRUCTIONS

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

JENCO ELECTRONICS, LTD.

Model 96VTR ¼ DIN Process Controller

GAS MONITOR Model Model

LC2200 Level Controller Installation and Maintenance Instructions

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

ACL TC 200 TEMPERATURE CONTROLLER

vibration switch

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

T-32-TS Touchscreen Thermostat. Installation Manual

ECO N DATE DESCRIPTION OF CHANGE CHG

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Model 144H. Product Data Sheet , Rev DB February Content

02/11/2015

EOTec 2C32 Installation Guide

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

General Specifications

Model 144H. Product Data Sheet , Rev DB February Content

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Nov 08 PRODUCT SPECIFICATION SHEET

Sierra Series 900 Single & Dual Channel System. Instruction Manual

ESSEX ENGINEERING CORPORATION

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Transcription:

Loop Alarm Model SC1490 and SCL1490 INSTALLATION INSTRUCTIONS LOVE LOVE CONTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX (219) 872-9057 www.love-controls.com December, 2004 Page 1 of 8 949-0531 Rev. 2

Getting Started 1.) Using a small screwdriver, ball point pen, etc. set the Input Switch (SW-1) on the side of the unit for the input range to be used. 2.) Set the Output Switch (SW-2) for the output responses required (see Output Programming on page 4). 3.) Mount unit into panel. (see Mounting on page 5). 4.) Connect unit to input signal, output signal, and power wiring (see Wiring on page 5). 5.) Check calibration (See Calibration on page 6). Operation description is on page 6 Specifications are on page 7. Copyright 2004 Love Controls Division, Dwyer Instruments, Inc. All rights reserved. 949-0531 Rev. 2 Page 2 of 8 December 2004

INPUT PROGRAMMING Switches 1 through 6 on SW1 allow selection for RTD type. Use the chart (Figure 1, below) to select the input type and range for your process. Turn on the appropriate switch(s) (as indicated) on SW1 for the input range desired. Figure 1 December, 2004 Page 3 of 8 949-0531 Rev. 2

OUTPUT PROGRAMMING Since the alarms can be set for reverse or direct action, high or low function, and has normally open and normally closed contacts; the number of combinations of actual output behavior is quite large. First, decide how you want the outputs to behave. Will the relay energize or de-energize at the trip point? Will the relay trip on an increasing or decreasing signal? Is the dead band above or below the trip point? It is important to answer these questions before setting up the module. The following Function Chart illustrates the most likely combinations of settings. Function Chart Figure 2 Using the Figure 3 (next page), set up the switches on SW2 for Alarm A and Alarm B. For dual alarm relays triggered by Alarm A, set switch 5 to DUAL. When switch 5 is set to DUAL (on), switches 6 and 7 have no effect. 949-0531 Rev. 2 Page 4 of 8 December 2004

Figure 3 WIRING Mount on DIN rail and wire per Figure 5 below. LOVE CONTROLS DIV. OF DWYER INSTRUMENTS, INC. MICHIGAN CITY, IN 46361, U.S.A. 290-2888 MADE IN U.S.A. + INPUT RTD T/C,V &I 1 2 4 5 3 6 N.C. COM N.O. ALARM A ALARM B N.C. COM N.O. TM 7 8 9 MODEL: S/N: 10 11 12 POWER For SC1490, power is 85 to 265 Vdc/Vac 50 to 400 Hz. For SCL1490 power is 12 to 24 Vdc/Vac 50 to 400 Hz. ±20%. Figure 4 WARNING: Do not attempt to operate this device with the cover removed. Potentially lethal voltage is present on some of the internal components. Do not open the unit. There are no internal adjustments or user serviceable parts in the unit. December, 2004 Page 5 of 8 949-0531 Rev. 2

ALARM CALIBRATION NOTE: Allow the module and socket to come to stable temperature before proceeding. For best results, allow the module to be powered in the socket for at least 20 minutes. Refer to Figure 5 when using the following procedure: 1. Apply the appropriate input for the desired alarm trip point. 2. Adjust the alarm AL screw for relay trip (LED changes color). 3. Adjust the alarm DB screw to the full clockwise position. Change the input to the desired reset point. Slowly turn the alarm DB screw counter-clockwise until the relay resets (Alarm LED changes back to original color). 4. Move the input back to the desired trip point to confirm correct setting. 5. Move the input to the reset point to confirm correct setting. 6. Repeat as necessary. A AL B RESET DB OPERATION Figure 5 On power up the module will automatically reset the alarms provided that no alarm condition exists. It may be necessary to reset a low alarm after the process has reached normal conditions. When the input is within set limits, both LED indicators will be green and the relay contacts will be in the state programmed for normal operation. If the input reaches either of the trip points, the relay connected to that trip point will change state and the LED connected to that point will indicate red. When the input returns to normal (trip point plus dead band for low alarm settings, trip point less dead band for high alarm settings) and switch 4 of SW 2 is set to NON-LATCHING, the relay and LED will automatically return to the non-alarm condition. If switch 4 of SW 2 is set to latching, the red RESET button on the top of the module must be pressed to return the relay and LED to the non-alarm condition. 949-0531 Rev. 2 Page 6 of 8 December 2004

SPECIFICATIONS Power Supply: SC1090: 85 to 265 Vdc/Vac 50 to 400 Hz. SCL1090: 12 to 24 Vdc/Vac 50 to 400 Hz. ±20% Isolation: 1500 V rms between outputs, input, and power. Set Points: Adjustable 0 to 100% of span. Deadband: Adjustable 0.25% to 100% of span. Drift: ±0.02% / C typical, ±0.05% / C maximum. Ambient Temperature Range: Operating: 0 to 55 C (32 to 131 F) Storage: -40 to +80 C (-40 to +176 F) Humidity Conditions: 0 to 90% up to 40 C non-condensing, 10 to 50% at 55 C non-condensing. Excitation Current: Cu10Ω = 5 ma; Plt 100Ω, Ni 100Ω, Ni 120Ω = 500µA; Plt 500Ω, NiFe 1000Ω = 100 µa; Plt 1000Ω = 50 µa. Lead Compensation Error: 0.02%/Ω. Open Lead Protection: Upscale only. Relay output: SPDT, one per set point, 5A @ 250 VAC, resistive. Latch circuit reset: Automatic at power up. Manual with reset switch on front of module. Indicators: One dual color LED per set point. Red = relay on, green = relay off. DIMENSIONS 22.5 (0.886) DIN EN 50022-35 (not supplied) AL B RESET A DB 75 (2.950) 35.5 (1.40) All dimensions in millimeters (inches) 9 8 7 12 11 10 (3.880) ADAPTER BRACKET FOR SURFACE MOUNTING (OPTIONAL) KIT#: 1007-35DINADPTR December, 2004 Page 7 of 8 949-0531 Rev. 2

NOTES 949-0531 Rev. 2 Page 8 of 8 December 2004