MacroAir AirSpan HVLS Fans

Similar documents
MacroAir AirVolution HVLS Fans

MacroAir AirElite HVLS Fans

MacroAir by Blue Giant AirVolution HVLS Fans

SECTION HVAC Fans

Make Your Employees Your Biggest Fans

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

SECTION Overhead Coiling Doors

STR-Series Indirect-Fired Air Turnover Units

SECTION HVAC Fans

SECTION OVERHEAD COILING FIRE DOORS

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION HVAC Fans

SECTION HVAC Fans

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

INSTALLATION GUIDE DO NOT DISCARD THIS DOCUMENT: SAVE FOR FUTURE USE

Industrial Fans & Blowers

SECTION AIR DOORS

SECTION ROTARY-SCREW WATER CHILLERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Operating Instructions & Parts Manual Models 99533, 99532

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Brasch Hazardous Location Unit Heaters

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

24 & 30 Quiet Design Oscillating Wall Mount Fan

CL & CLG Clamp Mount Mixers

Linear Heat Detection Engineering Specifications

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

ARCHITECTURAL SPECIFICATIONS

BL41 Extra-long Barrier

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

Vacuum Systems. A complete line of vacuum pumps and accessories for every dairy

SECTION AIR DUCT ACCESSORIES

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

It's simple... we move more air for less! The Kelley FUSION fan circulates the greatest volume of air while consuming the least amount of energy.

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION FIRE PUMP AND CONTROLS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

CR1 Series Triton Corrosion Resistant Washdown Heaters

Today's Topics & Sustainability Themes

"ESDDR" Series Electric Humidifier

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

SECTION FAN COIL UNITS

A. Codes and Standards that are Standard at the University:

Product Specifications Linear Accelerator Relay Junction Box

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

OWNER S MANUAL. General Ventilation Fans Electric Driven. PAL Series (Incl. 24 & 30) HD Series (Incl. -T & -S) 0316_01A

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

ADVANCING HVLS technology through controls and energy efficiency

GP-6 Cabmaker Owner s Manual and Operating Instructions

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION (15767) - UNIT HEATERS

Eldex Column Heater. Operator s Manual

CREWMAN 20 ORB CREWMAN 28 ORB

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Engineering Specifications

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

National Reach. Local Service.

FM-17DS & FM-20DS FLOOR MACHINES

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

Direct Fired Heater Model AD Specification

Installation Manual PLEASE READ AND SAVE THESE INSTRUCTIONS. Build September MacroAir Technologies 2005, Installation Manual, Page: 1

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Clean. Easy. COMPLIANT.

RITE-HITE FANS HVLS FANS A REVOLUTION. IN COST, COMFORT AND DESIGN.

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

IMPORTANT SAFETY INFORMATION

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Custom Duct Heaters. Special Applications

SECTION PACKAGED HEAT TRANSFER SYSTEM

PT9420 (Extended Range)

Comfort. Description. Applications

.2 Section Waste Management and Disposal.

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

DIVISION FINNED WATER-TUBE BOILERS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Chilled Water DOAS Fan Powered Terminal Units

A. Section Masonry Assemblies: Anchor placement in masonry.

Installation and Maintenance Manual Please retain this manual for future reference.

Quality Enclosures. Service Excellence.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

Transcription:

Manufacturer: MacroAir Technologies, Inc. 794 South Allen Street San Bernardino, CA 92408-2210 macroairfans.com SECTION 15830 INDUSTRIAL/COMMERCIAL CEILING FANS PART 1 GENERAL MacroAir AirSpan HVLS Fans 1.1 SUMMARY Featuring patented 6ixBlade technology, the AirSpan HVLS fan is MacroAir s largest, highest output fan and the ideal solution for industrial, warehouse, and commercial spaces that are over 10,000 sq. ft. The AirSpan generates a huge column of air that flows down to the ground and outward 360 degrees. The large, gently moving air mass moves through the space effectively mixing and circulating the air to create a more pleasant environment. 1.2 REFERENCES A. American National Standards Institute/Air Movement and Control Association (ANSI/AMCA) Standard 230-07 - Laboratory Methods of Testing Air Circulating Fans for Rating. 1.3 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer s data sheets on each product to be used shall include: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Power and mounting requirements. C. Application Drawings: Submit plan, section, elevation and isometric views as necessary to convey the information required to detail all installation conditions for each unit specified. 1.4 QUALITY ASSURANCE A. Manufacturer Qualifications: MacroAir shall provide sole source for design, engineering, manufacturing and warranty claims handling.

B. Installer Qualifications: Any and all work outside the scope of the installation guide shall be outsourced. Factory trained installers are recommended and available upon request. 1.5 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products in environmental conditions outside MacroAir's absolute limits. 1.6 COORDINATION A. The fan shall be capable of receiving a stop command from the fire panel, an ASD (Aspirating Smoke Detection) device, or any number of smoke, flame or heat detectors. B. The fans shall be as follows: 1. The fan shall meet the air velocity requirements of FM Global s 2.0 data sheet for ESFR sprinklers. 2. If required by the local fire prevention authority or desired by the purchaser, the fan shall be wired into the building s fire suppression system so that the fan will automatically shut off within a maximum of 90 seconds after sprinklers are activated. To facilitate this automatic shut-down, the fan shall include a Variable Frequency Drive (VFD) within the control panel. The low voltage wire and relay needed to accomplish this must be supplied by the Fire Alarm installer. 3. Upon fire detection as described above, the fans shall coast to stop as required by NFPA guidelines. 1.7 WARRANTY A. MacroAir shall repair or replace warranted defective parts as follows: 1. Lifetime warranty on airfoils, hub, frame and mounting. 2. Twelve-year service life prorated limited warranty on all other components which include but are not limited to: a. Motor b. Gear reducer c. VFD B. At project closeout, provide to Owner or Owner's Representative an executed copy of MacroAir's standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.

PART 2 PRODUCTS 2.1 APROVED MANUFACTURERS A. Acceptable Manufacturer: MacroAir Technologies, Inc., which is located at: 794 South Allen Street, San Bernardino, CA 92408-2210 Toll Free Tel: 866-668-3247; Tel: 909-890-2270; Web: macroairfans.com B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 MACROAIR COMMERCIAL / INDUSTRIAL HVLS FANS A. Performance Diameter Power Usage (kw) CFM per Watt Max. Effective Area (Sq. Ft.) FWD REV Typical Fan Model CFM CFM RPM Spacing db MA20XL1506 20ft 237,231 166,062 70 1.032 307 18,000 100ft 61 MA24XL2006 24ft 376,804 263,763 65 1.651 310 20,000 110ft 61 B. Airfoils The fan shall be equipped with six (6) NASA developed XL airfoils. The airfoils shall consist of anodized 6061 T4 precision extruded aluminum and be of the MacroAir XL design, with 20 and 24 foot fan diameters available. The airfoils shall be connected to 6 individual aluminum 6005 T6 struts by means of two (2) 5/16-24 x 2-inch grade 5 hex bolts, two (2) 5/16-inch flat washers and two (2) 5/16-inch nylon lock nuts per airfoil. 1. Number of Airfoils: 6. 2. Airfoil Material: 6061 T4 Extruded Aluminum. 3. Airfoil Finish: Anodized. 4. Optional Airfoil Finish: Custom powder coated colors per Drylac RAL color chart. C. Motor (20 foot model) The fan shall be equipped with a Baldor 1.5 Hp, 3-phase motor (explosion proof and stainless steel wash down configurations available). The motor shall be ventilated capable of continuous operation up to 104 F (40/50 C) ambient conditions.

1. HP: 1.5 2. 3-Phase. 3. RPM: 1725. 4. Service Factor: 1.25. 5. Full Load Amp draw: 4.7 4.4/2.2. 6. Insulation Class: B. 7. Motor Finish and Color: Painted grey. 8. Enclosure: TEFC. 9. Frame: 56C. 10. Duty: Continuous. D. Motor (24 foot model) The fan shall be equipped with a Baldor 2.0 Hp, 3-phase motor (explosion proof and stainless steel wash down configurations available). The motor shall operate on voltage ranging from 208-230/460 three (3) phase and 50/60 Hz. The motor shall be of the insulation class F. The motor shall be ventilated capable of continuous operation up to 104 F (40/50 C) ambient conditions. 1. HP: 2.0. 2. 3 Phase. 3. RPM: 1750. 4. Service Factor: 1.15. 5. Full Load Amp draw: 6.3 5.8/2.9 A. 6. Insulation Class: F. 7. Motor Finish and Color: Painted green. 8. Enclosure: TEFC. 9. Frame: 56. 10. Duty: Continuous. E. Motor Control Panel (MCP) and Remote Each Motor Control Panel is built pursuant to UL Standards as Industrial Control Panels and pursuant to construction guidelines set forth by UL article 508A and the National Electrical Code. The controls shall be housed in a NEMA 1 (optional NEMA 4X) enclosure to prevent unwanted exposure and to exclude entry of unwanted contaminant. The MCP shall include a Yaskawa J1000/V1000 Variable Frequency Drive (VFD). VFD shall operate on carrier frequency of no less than 8 khz in order to minimize sound. The VFD shall have a UL, CE and RoHS rating. Motor cable shall be a Belden foil-shielded cable with no more than 25 feet in

length and provided by MacroAir. No motor cable substitutions are allowed. The fan shall include a NEMA 4X Remote Switchbox for wall mounting and 100 feet of remote cable (up to 600 feet in length optional). Remote Switchbox shall include a forward, off, reverse and a speed control knob. 1. Electrical Requirements a. 208-240VAC single (1) phase 50/60 Hz. b. 208-240VAC three (3) phase 50/60 Hz. c. 380-415VAC three (3) phase 50 Hz. d. 460-480VAC three (3) phase 50/60 Hz. e. Lockable disconnect switch. 2. Pre-programmed VFD with dynamic acceleration and deceleration. 3. MODBUS option available. 4. BacNet option available. 5. Fire panel integration contacts. 6. Network touch-screen option available with: a. Live energy consumption monitor. b. Live fault code monitor. c. Live fan speed monitor. d. Impact and solvent resistant. e. NEMA 4X rated. f. IP65 rated. F. Gear Reducer The fan shall be equipped with a Dodge Quantis sealed gear reducer with pressure relief valve. The Gear reducer shall be an inline 2-stage helical gear reducer, precision finished for low noise and high performance. 1. Reducer Type: 2-Stage Helical. 2. Lubrication: Mobil SHC 630. 3. Maintenance: Lubed for life. 4. Material: Steel. 5. Bearings: HD deep groove needle. 6. Seals: Double lip high temp. 7. Output Shaft: Stainless steel 1-1/4 diameter. 8. Service Factor: 1.96. 9. Maximum Output Torque: 1,911 IN-LBS. G. Mounting and Frame The fan mounting system shall be equipped with hardware, no less than SAE grade 5 for safe installation. The fan shall be equipped with a

universal mount consisting of an upper yoke, knuckle and lower yoke. The fan shall be properly equipped for multiple mounting options for I- beam, Purlin and Glulam applications (specified upon order). 1. Standard Mount: Universal I-beam clamp with swivel joint and a 7.5 drop. 2. Optional Mounting Hardware: Glulam Mounting Brackets. 3. Optional Mounting Hardware: Extra Wide I-beam Mount. 4. Mounting Drops: Extensions available in one (1) to ten (10) foot lengths in one (1) foot increments and available in custom sizes. 5. Mounting Drop Material: A36 Welded Steel. 6. Frame Finish: Black powder coated. 7. Optional Frame Finish: Custom powder coated colors per Drylac RAL color chart. 8. Mount Finish: Black powder coated. 9. Optional Mount Finish: Custom powder coated colors per Drylac RAL color chart. 10. Frame Material: A36 Welded Steel. 11. Mount Material: A36 Welded Steel. H. Hybrid Hub The fan shall be equipped with a patent-pending, aluminum hybrid hub. The hybrid hub shall have six (6) removable, black anodized, 6005 T6 aluminum H-beam struts. The struts shall be designed with airfoil guides to ensure precision alignment and enable airfoils to be inverted for full CFM output in either reverse or forward operation. 1. Hub Material: 356 T6 Cast Aluminum. 2. Airfoil Strut Material: 6005 T6 Aluminum. 3. Airfoil Strut Finish: Black Anodized. 4. Hardware: Twelve (12) 3/8-24 x 1 ¾ -inch Grade 8 Hex Bolts. 5. Hardware: Twelve (12) 3/8-inch flat washers (SAE). 6. Hardware: Twelve (12) 3/8-inch nylon lock nuts. I. Safety System The fan shall include a patented two-part interlocking hybrid hub safety system. The hybrid hub safety system shall prevent hub separation from gear reducer. The fan shall include four (4) guy wires attached to the building structure at recommended 45 angles to level and secure frame position. The fan shall include one-piece airfoil retainer links to prevent airfoil separation from the hybrid hub. Included in the safety system shall

be fuses and a disconnect to prevent fire or misuse. Each fan shall be E- stop compatible for fire and building automated systems (BAS). 1. Safety Cable Material: 1/4 x 7 x 19 Aircraft Grade Braided Steel. 2. Safety Cable Finish: Galvanized. 3. Guy Wire Material: 1/8 x 7 x 10 Aircraft Grade Braided Steel. 4. Guy Wire Finish: Galvanized. 5. Safety Disc Material: A36 Laser-cut Steel. 6. Safety Disc Finish: Clear zinc. 7. Safety Retainer Plate Material: A36 Laser-cut Steel. 8. Safety Retainer Plate Finish: Black powder coated. 9. Airfoil Retainer Link Material: 10 Gauge A36 Steel. 10. Airfoil Retainer Link Finish: Clear zinc. 11. Hub Retainer Bushing PART 3 EXECUTION 3.1 PREPARATION A. Check accuracy of dimensions indicated for openings to receive fans. B. Check location and availability of utility services to ensure proper voltage and installation preparation. C. Coordinate location and installation of the HVLS Fans. D. Ensure building structural members are sufficient to support the weight and operation of the fan. Consult professional engineer or registered architect as required. 3.2 INSTALLATION A. Install units per manufacturer's written instructions. B. Fan airfoil height to be a minimum of 10 feet from the floor in accordance with OSHA guidelines. C. All safety and support features must be installed. These include any guy wires and safety cables as well as airfoil retainer locking features. D. Adjust unit as required for proper operation in accordance with manufacturer s installation instructions.

E. Securely anchor units. F. Ensure that operating parts turn freely prior to initial startup. G. Repair or replace damaged parts, dents, buckles, abrasions or other damage affecting appearance or serviceability, as acceptable to Architect. 3.3 PROTECTION A. Protect finished Work until date of Substantial Completion. B. Touch-up, repair or replace damaged products before Substantial Completion. 3.4 CLEANING A. Clean Work per Section 01 74 00. B. Clean and inspect fans per manufacturer's instructions. C. Remove temporary protective cover at date of Substantial Completion. END OF SECTION