Cast Iron Commercial Hot Water Or Steam Boiler

Similar documents
USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

User s Information Manual Models: 45, ,000 Btu/hr

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

User s Information Manual

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

User s Information Manual

User manual. Logano GC 124 II. Gas boiler

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

WHAT TO DO IF YOU SMELL GAS

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

MC Series Gas-Fired Heating Appliance

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL

User s Information Manual

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

USER S INFORMATION MANUAL

TO DO IF YOU SMELL GAS

Elite. User s Information Manual. Elite and Elite VWH* All Models

User s Information Manual

USER'S INFORMATION MANUAL

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

User s Information Manual

User s Information Manual

User s Information Manual Models:

User s Information Manual

HWX GAS BOILERS USER S INFORMATION MANUAL

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

/2010 US/CA

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

Residential Gas Hybrid Water Heater

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

G61MPV SERIES GAS FURNACE WARNING

DT/DTH/DR/DRH MERIT SERIES

WHAT TO DO IF YOU SMELL GAS

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

USER S INFORMATION MANUAL

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL

Tankless Water Heater

USER S INFORMATION MANUAL

Universal Fire Tube Boiler Wall Mount Models

Operating instructions

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

User s Information Manual Models:

Installation & Operation Manual Models:

User s Information Manual

Operating instructions

User s Information Manual

DT-2 & DR-2 MERIT SERIES

User s Information Manual

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

User s Information Manual

Fig. 1 - Unit PGD4, PGS4, WPG4

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

PROBLEM CAUSE SOLUTION

USER S INFORMATION MANUAL (2,4)SG13B

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

USER'S INFORMATION MANUAL

Owner s Information Manual

EL195DFE SERIES GAS FURNACE WARNING

G95V NATURAL AND PROPANE GAS TWO STAGE HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE USER S INFORMATION MANUAL

WHAT TO DO IF YOU SMELL GAS

User s Information Manual

GOLD. User s Information Manual. Water Boiler Series 4

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

EL195UH SERIES GAS FURNACE WARNING

FOR FORCED HOT WATER MODEL NUMBERS: 15045, 15070, 15096, 15120, 15145, 15175, 15195, 15245, 15295

User's Infomation Manual

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

USER'S MANUAL PGE Single Package Rooftop

WARNING FIRE OR EXPLOSION HAZARD.

User Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown

GAS FURNACE. User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas Furnace

Operating instructions

GAS BOILERS USER'S INFORMATION MANUAL SG-135-E TO SG-495-E AAA-480 TO AAA-3000

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

WARNING FIRE OR EXPLOSION HAZARD.

95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

ML180UH SERIES GAS FURNACE WARNING WARNING

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

LGB Gas fired boiler

Using it in an enclosed space can kill you.

This document was created with FrameMaker 4.0.4

User's Information Manual Customer Property: Contains wiring and service information.

NOTE TO INSTALLER: This manual must be left with the equipment user. Model 480BAV Upflow and 481BAV Downflow/Horizontal

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

Transcription:

Cast Iron Commercial Hot Water Or Steam Boiler Users Information Manual UTICA BOILERS PO Box 4729 Utica, NY 13504-4729 www.uticaboilers.com An ISO 9001-2000 Certified Company P/N# 240006925U, Rev. 1.0 [09/07]

Users information Manual Cast Iron Hot Water or Steam Boiler SAFETY SYMBOLS & Warnings The following defined symbols are used throughout this manual to notify the reader of potential hazards of varying risk levels.! DANGER! Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.! CAUTION! Indicates a potential hazardous situation which, if not avoided, MAY result in minor or moderate injury. It may also be used to alert against unsafe practices. IMPORTANT: Read the following instructions COMPLETELY before installing!! INSTALLATION AND SERVICE MUST BE PER- FORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. The manufacturer recommends that all boiler maintenance be performed by a trained heating technician. IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. Before any procedures are attempted on this appliance, it is necessary to determine if the ignition system is a electric or standing pilot system. If you are uncertain, contact the manufacturer before proceeding. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switches; do not use any phones in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. KEEP THIS MANUAL NEAR BOILER. RETAIN FOR FUTURE REFERENCE. 3

LIGHTING INSTRUCTIONS Water Systems: Before lighting any type of pilot burner (standing or intermittent), make certain the hot water boiler and system are full of water to minimum pressure of 12 lbs. per square inch in the system, and also make certain that the system is vented of air. Refer to the following appropriate lighting instruction. STEAM SYSTEMS: Before turning on a steam boiler make certain the boiler is filled to the water line as indicated in Figure# 3. The gauge cocks should be open. To flush out the glass, to remove dirt, the petcock may be opened. LIGHTING PROCEDURE FOR BOILER WITH INTERMITTENT PILOT SYSTEM For Your Safety, Read Before Operating!! A. Read warnings at the beginning of this manual. B. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the appliance by hand. C. Before operating, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. Read "What To Do If You Smell Gas" on page 2 of this manual. OPERATING INSTRUCTIONS FOR INTERMITTENT PILOT SYSTEM 1. STOP! Before continuing, read For Your Safety, Read Before Operating!! safety information. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. 5. Turn gas control knob clockwise to OFF. 6. Wait (5) minutes to clear out any gas. If you then smell gas, STOP! Follow What To Do If You Smell Gas in the safety information on page 3. If you don t smell gas, go on to the next step. 7. Turn gas control knob counterclockwise to ON. (Figure #1 & #2) gas control knob Figure #1 Robert Shaw 7000 DERHC Series Gas Valve (500 Base) D. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don t try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion. E. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 8. Turn on all electric power to the appliance. 9. Set thermostat to desired setting. 4

LIGHTING INSTRUCTIONS Figure #2 Honeywell VR8300 Series Gas Valve (300 & 400 Bases) To Turn gas off to Appliance 1. At the end of the heating season, or if the boiler fails to operate, set the thermostat to the lowest setting. 2. Turn off all electric power to the appliance before servicing.! DANGER! Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. gas control knob 10. If the appliance will not operate, follow instructions 1-5 above and call a qualified service technician or your gas supplier. 3. Push in gas control knob slightly and turn clockwise to OFF. DO NOT FORCE. 4. Call a qualified service technician if experiencing a problem. General Maintenance INSTRUCTIONS Before the beginning of each heating season have a professional service agency check and clean the boiler if necessary. Check for the following: 1. Flue ways for dirt and scale. 2. Venting flue connectors for plugging, sagging, rust through and solid joints. 3. Burners and pilot for proper flame and operation. 4. Gas piping and flex hoses for leaks. 5. Operation of electronics and wiring condition. 6. Functionality of low water cutoff (steam). 7. Functionality of Pressure Control. 8. Water pump oiling (See vendors manual). 9. Pop or pressure safety valve. 10. Blow down. 11. Air vents on steam heaters. 12. Operations of other custom system components. 13. Purge air from water systems. 14. Clean and Flush steam systems, if required, and fill to proper level. (See Figure #3 next page) DISCHARGE OF WATER, VAPOR AND STEAM MAY SCALD. 5

General INSTRUCTIONS WATER AND STEAM ARE UNDER PRESSURE, OPEN ALL VALVES SLOWLY. DISCHARGE OF WATER, VAPOR AND STEAM MAY SCALD. The owner should be aware of weekly and monthly maintenance. Since some equipment is non-factory installed, please refer to manufactures literature. Weekly, do the following. All steam and water boilers are equipped with pop or pressure safety relief valves. The lever of the safety relief valve should be operated periodically to ensure proper operation. If the safety relief valve leaks steam when the boiler is operating at the normal pressure it must be replaced. On steam boilers with manual low water cut-off valves, open the purge valve until the water flows clear. (Figure# 3) Steam Boilers: During the heating season the owner should blow down the boiler at least once each month. Before blowing down the boiler, fill it to the water line. Light the burners and allow steam pressure to build up. Run a temporary connection from one of the drain valves. If possible, connect a hose to the drain valve on the opposite side of the boiler from the make up water. Shut off the gas burners, open the drain valve and blow down the entire contents of the boiler. Allow the boiler to thoroughly cool and slowly refill to the water line. Repeat the process as many times as required until the blow-off water is clear. Figure #3 Steam Boiler Optimum water level! Caution, water is HOT. Maintain proper water level Flush manual low water Cutoff once a week. 6

NOTES 7

UTICA BOILERS PO Box 4729 Utica, NY 13504-4729 www.uticaboilers.com