HOMEPUMP ECLIPSE* Ambulatory Infusion System PATIENT INFORMATION

Similar documents
Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

Administration of AMBISOME Using the GemStar Pump

PREASSEMBLED SURGICAL WASH SET FOR DIDECO COMPACT ADVANCED Instructions for Use Product Designations: WS-55C, WS-125C, WS-175C, WS-225C DESCRIPTION:

Ambulatory infusion pump for continuous, intermittent, TPN or PCA delivery.

Thoracic drainage. Helping improve patient outcomes

PREASSEMBLED SURGICAL WASH SET FOR DIDECO ELECTA

v.a.c.simplicity TM Quick Reference Guide Power Connection Canister Battery Charging Light Control Panel

Hemovac Wound Drainage Family. The Time-Tested System for Reliable Wound Drainage and Auto-Transfusion

Original Perfusor & Infusomat

Tube Feeding by Pump UHN. Information for patients and families. Read this book to learn:

bibag System User s Guide

Vernay-QM Series Disposable Pumps

Rocket Quick Guide. Rocket PSU Portable Suction Unit

Speed switch moves up or down to adjust speed. Fast. Medium

ALLERGEN MIXING ASSISTANT

SINGLE SPEED SYRINGE PUMP

VARIABLE RATE INFUSION PUMP

Clinician Information

Home Choice cycler for Peritoneal Dialysis: Set up, Disconnect, & Disposal Updated 2015

*smith&nephew VERSAJET HYDROSURGERY SYSTEM

VPAP COPD. H5i. Welcome Guide. Making quality of care easy. Respiratory Care Solutions. English NONINVASIVE VENTILATOR HEATED HUMIDIFIER

Description of the CADD-Prizm VIP Pump

CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

Syringe Pump. User Manual

Thopaz+ Quick Reference Guide. Precious life Progressive care

EXTERNAL CARDIAC AMBULATORY TELEMETRY

Proven Quality Made in Germany

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

The list is not exhaustive and where there is any doubt about the VAT status of items not included here please contact the UCL Tax Team.

Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual

System One Heated Humidifier USER MANUAL

1 Intended Use of the Breas HA 01 Humidifier

Sapphire TM. Bring Home The Future Of Infusion Care. Ambulatory Infusion System. > Intuitive, easy-to-use touch screen design

Portable 30 lb. Clear Ice Maker Item #512786

AIR. Low-Air Loss Combined with. Advanced Wound Therapy & Fall Prevention in a Non-Powered Mattress. Non-Powered Therapy

CBC II Blood Collection & Reinfusion System. Installation and use in Operating Room

SERRES SUCTION BAG SYSTEM MANUAL

VPAP Adapt. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

Cool Flow & CoolOR PERSONAL COOLING SYSTEMS POLAR PRODUCTS polarproducts.com

Troubleshooting/Access/Alarms Simulation. Wendy McCay, MPH, BSN, OCN Brenda Stofan, RN

Thoracic drainage upgrade:

User guide User guide English

Caring for your Drain Tube at Home

Alaris Syringe module FAQs

Oxygen Concentrator Instruction Booklet

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

S9 Escape. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE

EkoSonic Control Unit Instructions for Use

BARD WOUND DRAINAGE. Products to meet your different procedural needs CLOSED WOUND SUCTION GRAVITY DRAINS SUMP DRAINS

H4i. User Guide HEATED HUMIDIFIER. English

AutoSet AutoSet for Her Elite Escape Auto Escape. H5i H5i for Her. Welcome Guide. English. POSITIVE AIRWAY PRESSURE DEVICEs HEATED HUMIDIFIER

Physician s order will specify the level of underwater seal, typically -10 to 20 centimetres (cm) and will identify if suction is to be applied.

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

VPAP Auto VPAP ST VPAP S. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss OPERATOR S MANUAL

Syringe Pump. Syringe Pump. Product Model: ZD-50C6 Syringe Pump. ZD-50C6-H Syringe Pump

VPAP Adapt. H5i. Welcome Guide. English. adaptive servo-ventilator

Portable Ice Maker User Guide

H4i HEATED HUMIDIFIER

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

AIR EXPRESS LAL. P1500 LOW AIR LOSS THERAPY SYSTEM REF C1500 Control Unit REF M1500 Mattress. Operator s Manual P/N /03

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

ELITE (110V) (220V)

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Instructions For Use. Hybernite ROC 2300 Rainout Control System

Thorametrix TM Chest Drainage Systems

Ink Degasser for Pro-HP Bulk System Installation and Operation Manual

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

The Professional Choice

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

APH166 Morpheus Air USER MANUAL. Issue 3-24/05/2017. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

S9 AutoSet & S9 Elite

MULTI FLOW HYDROPONIC SYSTEM

MULTI-FUNCTIONAL PORTABLE ROTATION SYSTEM P4000 P4001 C4000 Series Control Unit M4000 Series Mattress. Operator s Manual P/N Rev B 10/10

Duodopa. Important Risk Minimisation Information Patient Pocket Guide EDUCATIONAL MATERIAL FOR RISK MINIMISATION

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Dyna-Form Air. Alternating Pressure Relief Overlay System

Scotsman Technical Training. CU50 Cube Ice Machine

USER MANUAL For Clinicians. Rx Only

Prevas Disposable Dosing System. Department 3/5/2008 Interphex Robert Bosch LLC and affiliates. All rights reserved.

The Professional Choice

TP500 / TP500C Heat Therapy System STANDARD (NORME) C22.2 NO 125 RISK CLASS (CATEGORIE DE RISQUES) NO 2G OPERATOR'S MANUAL PIN /98

Wagner Product Training

THORAMETRIX. Chest Drainage Program

5000 Series Bottled Water System by.

Portable Air Conditioner USER MANUAL

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

FACSCalibur Startup Procedures

INSTRUCTION MANUAL OF WATER DISPENSER ΜΟDEL: CLWD-19PW

User s Manual. Alternating Air Mattress Model No.: MA-6100

Introduction. Table of Contents

Owner's Manual. WS Series. Water Softener

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

OPERATING MANUAL COOLING MODEL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST9ASJCW AST12ASJCW

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

Portable Air Conditioner User Manual

USER INSTRUCTION MANUAL SAPPHIRE SERIES 800

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

CT-930CH, CT-930LPCH and CT-940CH TABLE OF CONTENTS

Transcription:

HOMEPUMP ECLIPSE* Ambulatory Infusion System PATIENT INFORMATION

IMPORTANT PATIENT INFORMATION Patient name Medication (name and dose) Emergency contact phone numbers Health care provider contact Information Start your medication infusions at these times Length of infusion (approximate) Pump tubing: Primed (filled with medication) Not Primed (not filled with medication) Close tubing clamp to stop infusion and immediately contact your health care provider, if you have any of the following side effects: Store your pump in: Room temperature Refrigerator Freezer Remove the Homepump Eclipse * System from storage hours before use. CAUTION: Never put the pump in the microwave, direct sunlight or in water to warm your pump. Catheter/access device instructions:

WHAT IS THE HOMEPUMP ECLIPSE * SYSTEM? The Homepump * System is a disposable infusion system that delivers your prescribed medication through a catheter (tube). The pump is compact, lightweight and portable. Fill port cap Fill port Soft shell design Color coded labels for easy identification End cap Inner membrane is compatible with multiple medications HOMEPUMP ECLIPSE * Luer lock connector Clamp Tubing 200 ml hr Integrated particulate and air-eliminating filter 1

HOW DOES IT WORK? The system consists of a balloon type membrane (pump) which holds the medication. The pump provides the pressure to automatically infuse the medication at a preset flow rate. Depending on the size of the pump, infusions will last from 15 minutes to 5 hours. Your nurse will give you detailed instructions about your care. STORAGE Your nurse/home health provider will tell you how your medication should be stored. Make sure the pump is at room temperature during use, or the cold fluid will slow the infusion. The chart below shows the amount of time it takes for your pump to reach room temperature. The size ml of your pump is printed on the label around the fill port. Size (ml) Remove from Refrigerator (hours) Remove from Freezer (hours) 50 7 12 100 8 16 250 12 25 400 15 29 500 18 30 If you use multiple Eclipse* pumps each day while you re receiving a dose of medicine, take the pump with the next dose of medicine out of the refrigerator. This will allow each dose enough time to reach room temperature prior to use. CAUTION: Never put the pump in the microwave, direct sunlight or in water to warm your pump. 2

INFUSION PREPARING THE INFUSION 1. Before infusing your medication ensure that: Your name is correct on the label The medication and dose are correct Expiration or Use By date has not passed The end cap and fill port cap are in place Figure 1 If any of the above are not correct or missing, DO NOT use the pump. Contact your health care provider. 2. Wash your hands thoroughly with soap and warm water. Dry thoroughly. As instructed by your nurse, follow the procedure on how to clean and prepare your catheter/access device before connecting the pump. Figure 2 3. You may receive the Homepump * System with the tubing already primed (filled with medication) or you may need to prime the tubing. Refer to page 2 to see if your pump tubing is primed (filled with medication). Figure 3 If pump is not primed, follow these steps: Remove the end cap on the pump tubing (Figure 1). Open the clamp (Figure 2) and wait until you see a drop of medication at the end of the tubing. Allow the tubing to fill with Figure 4 medication. When you see the drop at the end of the tubing (Figure 3), close the clamp (Figure 4). 4. Following the connection procedure as instructed by your health care provider, attach the luer lock connector on the pump tubing to your access site. 5. Open the clamp to start the infusion (Figure 2). 3

INFUSION (Continued) DURING THE INFUSION Depending on the size of your pump you should notice a change in the look and size of the pump fairly quickly (less than 30 minutes). Do not squeeze the pump. The pump has the force to deliver the medication. WHEN CARRYING THE PUMP: Keep the pump as close as possible to the same level as your catheter/access device. During use, place the pump in a carrying case, your pocket, or on a table/bed next to you. Check with your health care provider regarding availability of clips/carrying cases. SLEEPING: Depending on your therapy, you may be using your pump while sleeping: Make sure the pump is placed on a bedside table or on top of the bed covers. Do not place the pump underneath the bed covers where the pump may become too warm. Do not place the pump on the floor or hang the pump on a bed post. END OF INFUSION All your medication has been delivered when the pump is empty. The outside bag will be flat and a hard tube can be felt in the middle of the pump. Disconnect the pump from your catheter/access device and dispose according to the instructions from your nurse. Empty pump CAUTION: Do not reuse the pump. 4

TROUBLESHOOTING IF THE PUMP DOES NOT SEEM TO BE WORKING, MAKE SURE: The pump is at room temperature. The white clamp on the tubing is open (moves freely on the tubing). All clamps on your catheter are open. There are no kinks in the pump tubing. The filter is not taped or covered. Follow your nurse s instructions to make sure that your catheter/ access device is working. WHAT TO DO IF THE HOMEPUMP * SYSTEM LEAKS: 1. Close the clamp on the tubing. 2. If your medication gets on your skin, immediately wash the area with water. 3. Immediately contact your health care provider. 4. Please save the pump for your health care provider to return to the manufacturer. WHAT TO DO IF THE PUMP TUBING BECOMES DISCONNECTED FROM YOUR CATHETER/ACCESS DEVICE: DO NOT reconnect. Close the tubing clamp and immediately contact your health care provider for instructions. 5

There are inherent risks in all medical devices. Please refer to the product labeling for Indications, Cautions, Warnings and Contraindications. Failure to follow the product labeling could directly impact patient safety. Physician is responsible for prescribing and administering medications per instructions provided by the drug manufacturer. Refer to www.halyardhealth.com for product safety Technical Bulletins. For more information please visit halyardhealth.com 1-800-448-3569 1-844-HALYARD (1-844-425-9273) *Registered Trademark or Trademark of Halyard Health, Inc. or its affiliates. 2015 HYH. All rights reserved. US Patent Nos 5,284,481C1; 5083,741. Foreign Pat. Pending. MK-00286_Rev2 01/2015