Home Performance Energy Audit Report

Similar documents
Home Performance Energy Audit Report

Home Performance Energy Audit Report

Home Energy Audit. 170 Security Circle Suite 104 Athens, GA

WHY IS BUILDING SCIENCE IMPORTANT?

HOME PERFORMANCE ENERGY ANALYSIS

FirstEnergy Program Overview

Supplement A- Improving Forced Air Heating Systems

Pro Eco-Energy. Home Assessment

TASKS REGARDING COMBUSTION AIR

New Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011

Prepared by Advanced Energy Efficiency & Environmental Quality (AE3Q) Kirsten Shaw 1743 S Horne, Ste 100 Mesa, AZ

Home Cooling Fact Sheet. Stay Cool, Comfortable, and Cut Costs.

BPI ANALYST ENVELOPE AUDIT FIELD EXAM CHECKLIST

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Energy Saver 101: Home Energy Audits

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

The Unplanned Impacts On Houses By Powered Attic Ventilators

HOME ENERGY SAVINGS GUIDE

MBPA Home Performance FIELD DATA COLLECTION FORM

SnuggPro DATA COLLECTION FORM

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

2017 Home Rebates Guidelines

ENERGY PERFORMANCE SCORE

Indoor Environmental Quality

Energy Upgrade California Home Upgrade Offered by The Energy Network

The Heating System and Ventilation and Combustion Air

Home Performance Science

GreenJet Transfer Fans

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

Start today and start saving!

Inspection Summary. Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (480)

Basic Building Science insights for Spray Foam, HVAC and Moisture

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

4. A 2 X4 knee wall, if insulated, should be to what R value? 5. The clearance between insulation and a furnace vent should be:

Home Energy Savings Guide

HOME ENERGY SAVINGS GUIDE

Audit. What do you envision when you hear the term energy

USER S INFORMATION MANUAL

EnergyMeasure HOME DATA COLLECTION FORM

Choosing Heating and Cooling Systems

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Evaluate your insulation. Look for a tag in the attic that shows the R-Values of insulation in the floors, walls and ceiling.

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

A Necessity for Preventing Unsafe Backdrafts and Unhealthy Air

ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention

Consumer Features & Benefits of Energy Efficient Products

EL195DFE SERIES GAS FURNACE WARNING

ENERGY STAR Qualified Homes

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

Home Energy Assessment Report

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

Building and Remodeling to Save Energy 1

EL195UH SERIES GAS FURNACE WARNING

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

2015 MECHANICAL CODE REQUIREMENTS

EARTH ADVANTAGE HVAC REQUIREMENTS

2013 REPOWER INCENTIVE GUIDE

UPGRADES. [Energy Efficiency] Base Points

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Spray Polyurethane Foam and Open-Combustion Appliances

RESNET HERS Rater Sample Test Questions 2

Ventilation Techniques. Topic 5 - Audio 53

WHAT S UNDER YOUR ROOF?

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

Building Science Basics

The evil that men do lives after them; the good is oft interred with their bones.

USER S INFORMATION MANUAL

G61MPV SERIES GAS FURNACE WARNING

WHOLE-HOUSE VENTILATION SYSTEMS

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

Heat Transfer and Your Electric Bill

BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS

The Art of Building Science

FAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017

Getting in the Zone with Zonal Pressure Diagnostics

Tech to Tech May 07 HRV s & ERV s

HVAC Equipment Access Equipment Location

Monty Anderson Construction Group Home Address: 3251 Great Oaks Boulevard Kissimmee, FL Certified: Score: 164

Equipment Specifications and Required Information Quantity Rebate

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Ventilation in Humid Climates: Data from Field Experiments

WAP Pressure Diagnostics Procedure. Page 1

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

Customized Energy Audit Report

Designed with the environment in mind.

Montana Weatherization Program WEATHERIZATION FINAL INSPECTION REPORT (Mobile Homes) Client Name Address Contact phone # Inspector Name and QCI#

BPI 1200 and ASHRAE Standards

Home Performance Analysis

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

SAMPLE. far, and we look forward to providing energy saving. Upgrade Details 8:30AM-5PM PST Mon-Fri

BALTIMORE GAS AND ELECTRIC COMPANY (BGE) Home Performance with ENERGY STAR Program. Rebate and Incentive Instructions

Low-Impact Remodeling

Uneven Heating/Cooling Before selling zones, CONTAIN CONDITIONED AIR Best Practices for Air Barriers

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Transcription:

BPI Certified Auditor: Homeowner: Address: Email: Utility Company: Post Audit Date: Jeff Metzger Richard Wooldridge- Test In 936 S Ocotillo Dr Apache Junction AZ, 85120 (602)321-6749 none SRP Marshall Insulation 1 P age

HVAC SYSTEM ASHP Rheem 3 Ton 1979 Pressure Pan Readings Duct Leakage Results 0.7-1.5 pa 740 No Mastic on ducts Visible leakage Why is this important? As much as 1/3 of your home's expensive conditioned air may be leaking into or being pulled from to the attic or other unwanted areas through cracks or poorly fitting duct connections. In addition, to increasing utility bills, indoor air may be contaminated with pollen, exhaust fumes, or other hazards. Pressure pan readings under negative pressure should be less than 1.0pa.. Recommendations: 1. Seal ducts with Mastic and test for leakage 2. AC unit is over 20 years old, need to replace. Marshall Insulation 2 P age

ROOM PRESSURE TESTING Room Pressure Testing/Total Rooms 2 1. Master bedroom 15.9 2. Spare room 10.7 Why is this important? High room pressures (greater than +/- 3 Pa) do not allow for air to mix and exchange, causing the unit to run longer and increasing occupant discomfort due to uneven air temperatures. Additional Notes: These high or negative room pressures are only a concern if the bedroom doors are kept closed for any period of time. Recommendations: 1. Keep all doors open or install In Door Passive Vents to balance home. If needed Marshall Can provide and or install these items. ATTIC FLOOR INSULATION Marshall Insulation 3 P age

For insulation to be effective, it must be in 100% contact with the air barrier, no gaps, voids, or compressions. A ½ gap in the air barrier reduces the R-value by 75%. Total Attic Square Footage: 1210 Insulation type: Blown in fiberglass Average Depth: 5 inches Overall Installation quality: Effective R-value: Description: Customer has very little insulation in the attic and it needs to be upgraded to R38. Recommendations: Upgrade insulation to R38 CFM50 Blower Door Infiltration Test was 1700 @50 pa negative pressure. Air Changes per hour ACH@50 was 15.0 Marshall Insulation 4 P age

Recommendations 1. Replace front and rear doors/ visible leakage- 2. Replace windows only single pane windows, one window is completely broke. 3. Seal all attic penetrations on the ceiling floor. Why is this important? Your home needs to breathe to be healthy. Too much leakage brings contaminants into the home, and increases CFM50 while too little leakage does not allow healthy air exchange with the outside. SAFETY-COMBUSTABLE APPLIANCES Marshall Insulation 5 P age

Why is it important? A large negative pressure inside the home will pull carbon monoxide and other toxins from combustion appliances and the garage. Unsafe water heater placement can be a potential fire danger and can cause other serious dangers. Recommendations: 1. Keep all Flammable Items away from Water Heater. 2. Water heater is 4 years old, no need to replace. WINDOWS Existing Windows = Single Pane Windows that demonstrate high leakage. Marshall Insulation 6 P age

Marshall Insulation 7 P age

Why is this important? With 300+ days of sunshine a year, homes in Phoenix are exposed with large amounts of radiant energy from the sun. Windows are a large source of air conditioning load along with causing considerable comfort issues. Shade screens can reduce the sun s rays by 80-90%. Recommendations: N/A 1. Customer has new shade screens. 2. Replace windows if possible- Marshall Insulation 8 P age

Abbreviations: CFM50= Cubic Feet per minute air leakage at 50pa negative pressure. ACH@50= Air Changes per hour @ 50pa negative pressure Additional Items to be addressed: 1. Need to paint the addition with fresh paint. Marshall Insulation 9 P age

Thank You for your Business! Marshall Insulation 2328 W Huntington Dr Tempe AZ, 85282 480-678-5040 marshallinsulation.com Lic# AZROC 228694 Licensed-Bonded-Insured Marshall Insulation 10 P age