DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

Similar documents
ADVANCE EASYLIFE PROJECT

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

After Sales Service Guide

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

GTU C 220 FUEL OIL CONDENSING BOILERS

isense Pro DIN - AD280

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

C 230 ECO. Control panel. DIEMATIC-m3 (GV6) Installation and Service Manual E

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

PRODUCT CATALOGUE

4FLOOR-STANDING GAS CONDENSING BOILERS

Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

PROGRAMMABLE 7-DAY RF THERMOSTAT

FLOOR STANDING GAS CONDENSING BOILERS HOMOLOGATION C 630- ECO: B 23 - B 23P - C 33 - C 53 - C 63 - C 83 - C 93

Modulating clock thermostat

HPI EVOLUTION ADVANCE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

PROGRAMMABLE 7-DAY THERMOSTAT

G a

Oil-fired condensing boiler GTU C 330. User Guide B

Type summary Albatros 2

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

INSTRUCTION FOR THE USER THC V E OIL BLU

C ECO FLOOR STANDING GAS CONDENSING BOILER CONDITIONS OF USE HOMOLOGATION GAS CATEGORY

PMC-M WALL-HUNG GAS CONDENSING BOILERS

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

TR 0603mc U Solar Controller

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

WHE 2.24 / WHE 2.24 FF

Operating instructions

Condensing Boiler RS100 Controller Training Program

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

BSC...E - BSP...E - BESC...E

REMOTE CONTROL FOR CHILLER MYCHILLER

Modulens G >> >> >> Condensing in excellence mode

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products

RVL47. Heating Controller. Installations Instructions. Installation

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

8FUEL OIL CONDENSING BOILERS

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

P5253 JS F Mertzwiller N IT /02/2013

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Daikin Altherma Hybrid User Guide

Range GT GTU C GT 220

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Gas-fired boilers DTG 230. User Guide D

<< >> Condensing technology at the service of oil. Controlling energy to save money

Logamatic 4000 Modular Control System Control Units and Extended Functions

Safety & Installation Instructions

ST 53.1 User s manual

System Installation. multi-zone heating

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

HT V2 HT Split

RVL481. Heating Controller. including d.h.w. heating

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Installation and user manual

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

english Steca Solar Thermal hot water from the sun. Solar Thermal

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

User Manual for model

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

SOLO User Guide. Description. Installation. Programmable Dual Voltage Thermostat 240 V (120 V)

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

120+ Get your job done swiftly Easy selection of your application is the key. applications.

Across-the-Line SERIES MP300 Combined Manual and Automatic

Soft Start Series MP700 Solid State, Reduced Voltage

User Guide. itec.

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

Intellicomfort CH140GSM

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Vokèra OpenTherm 711 without external sensor connected

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

Installation and servicing instructions

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

- Data Brochure Steam Control 279

Transcription:

DIEMATIC WALL-MOUNTED CONTROL SYSTEM Electronic control system capable of controlling 2 heating circuits, a DHW circuit and an auxiliary circuit EC identification No.: 0085CM0178 Electronic microprocessor control system in the form of a wall-mounted box. It can manage and control 2 hydraulic circuits, a DHW circuit and an auxiliary circuit and can operate according to 3 configurations: - Alone; - As part of a network with other DIEMATIC control systems; - With or without primary loop control. It can also communicate with a boiler via the OpenTherm or Modbus protocols. The very advanced control panel with new ergonomics allows problemfree programming and consultation of all installation parameters, using menu-driven navigation. Numerous options such as temperature sensors (outside sensor, DHW sensor, sensor downstream of the valve, storage tank sensor), interactive remote controls with room temperature sensor, (wire- or wireless-controlled), a vocal remote monitoring module, are also available. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm POWER SUPPLY 230 V, 50 Hz, 6 A PROTECTION RATING IP 21 EQUIPMENTS

PRESENTATION OF THE DIEMATIC VM i. System CONTROL SYSTEM The DIEMATIC control system comes in the form of a compact wall-mounted box (L 320 mm, H 260 mm, D 130 mm) with low voltage (230 V) and very low voltage (< 24 V) electrical connection zones. The waterproof ABS box (IP 21) is fitted with a transparent polycarbonate flap, which can be locked (using a screwdriver), that allows the readout of various parameters on the display unit. This box can be mounted on the wall (drilling template attached), on the front of a control cabinet or integrated inside the cabinet. The electrical connections are made from underneath (the holes for the wires are pushed out and the cable glands are provided). The DIEMATIC control system is delivered without sensors and must therefore be completed with the appropriate accessories for the type of installation concerned (see page 11). As standard, the DIEMATIC control system can be used to control two hydraulic circuits, a DHW circuit and an auxiliary circuit. Depending on the user s preferences, each of the 2 hydraulic circuits can be used as: - A heating circuit fitted with a motorised 3-way valve; - A direct heating circuit; - A swimming pool circuit. Hinged readout flap DIEMATIC control system module Main On/Off switch 6 AT fuse 2-position Auto/Manual switch (forced operation) VM_Q0005 Electrical connection zone SCENARIOS IN WHICH DIEMATIC CAN BE USED VM The DIEMATIC control system can operate: - Fully autonomously (see page 3) - By communicating with other generators (cascade) via the Modbus or OpenTherm protocols (see page 5) The DIEMATIC control system can be used alone (autonomous) or as part of a network (several control systems interconnected by a bus). It is compatible with DIEMATIC 3, m3 and isystem control systems and can also be used with any kind of generator equipped with an OpenTherm interface or an ON/OFF (0/1) control. Each DIEMATIC control system has to be configured according to: - The type of installation to be created (number and type of generators, number and type of circuits to be managed); - The type of existing installation as part of an extension (number and type of generators and control systems, number and type of circuits to be added). The choice of configuration mode is made in the «installer» navigation menu before commissioning the installation. Each DIEMATIC control system can manage up to 2 circuits with 3-way valve, a DHW circuit and can be fitted with 2 remote controls. It also has an AUX outlet that can be used to: - Control the load pump on a second DHW circuit; - Control the DHW loop pump; - Control a primary pump (connected to the VM); - Be used as an alarm transfer; - Be used as an ON/OFF control. 2

bar PRESENTATION OF THE DIEMATIC VM i. System CONTROL SYSTEM DIEMATIC NOMOUS CONTROL SYSTEM(S) The DIEMATIC control system can be used for the autonomous control: - Of additional secondary circuits as part of an installation extension; - Of a boiler with the AUX outlet for ON/OFF (0/1) control; - Of secondary circuits as part of a sub-station. In all cases, it should be fitted with an outside sensor (package FM 46). It is possible to interconnect up to 20 DIEMATIC VM isystem control systems by means of a BUS cable. Each of the control systems can be equipped with 2 remote controls. Application scenario No management of the primary circuit Management of a boiler with the AUX outlet for 0/1 control possible Management of 2 circuits: direct or with mixing valve (circuits B and C) and 1 DHW circuit Requires an outside sensor Up to 2 remote controls per control system Principle or VM_F0008 Operating principle The DIEMATIC control system manages 1 underfloor heating circuit according to the outside temperature, a low temperature circuit and DHW production. 230V 230V VM_F0003A Operating principle The DIEMATIC control system manages the boiler, via the 0/1 control, according to demand. It also manages the 2 heating circuits and the DHW circuit. VM_F0010B 3

bar PRESENTATION OF THE DIEMATIC VM i. System CONTROL SYSTEM DIEMATIC NOMOUS CONTROL SYSTEM(S) (CONTD) Operating principle The DIEMATIC control system is used as part of a sub-station. It manages the 2 circuits connected according to the outside temperature in a totally independent manner. VM_F0001B DIEMATIC CONTROL SYSTEMS COMMUNICATING WITH GENERATORS The DIEMATIC control system can communicate with: - A boiler or a cascade of boilers equipped with a DIEMATIC 3, m3 or isystem control system via the Modbus protocol. Communication with boilers equipped with DIEMATIC 3, m3, isystem control system (see page 5) The DIEMATIC control system can be linked to a boiler equipped with a DIEMATIC 3, m3 or isystem control panel via a BUS cable. In a cascade of generators equipped with DIEMATIC 3, m3 or isystem, the DIEMATIC control system is under the Communication with boilers equipped with an OpenTherm connection (see page 6) The DIEMATIC control system can be connected to a generator equipped with the OT (OpenTherm) interface to manage it according to needs and the outside temperature. - A generator or a cascade of generators equipped with an OpenTherm (OT) interface. control of the master generator. Depending on the configuration of the installation, it is possible to interconnect up to 20 DIEMATIC control systems by means of a BUS cable. When it is used as part of a cascade, each of the boilers should be equipped with an interface (package AD 286 or AD 287) available as an option. 4

TS N L TS N L 0 l AUX L L TS N 30 C C C bar C C C bar bar C 4 AT C C C PRESENTATION OF THE DIEMATIC VM i. System CONTROL SYSTEM DIEMATIC CONTROL SYSTEMS COMMUNICATING WITH GENERATORS (CONTD) DIEMATIC alone or as part of a network in a cascade of boilers with DIEMATIC 3, m3 or isystem control system Application scenario Management of 2 circuits: direct or with mixing valve (circuits B and C) and 1 DHW circuit Optional outside sensor Networking of 1 to 20 DIEMATIC control systems with 1 to 10 generators equipped with a DIEMATIC AUX outlet Up to 2 remote controls per control system Diematic m3 / isystem Principle no. 1 BUS BUS BUS no. 20 VM_F0008 Operating principle The DIEMATIC isystem control system on the master boiler manages the DIEMATIC control system(s) via the BUS connection. The DIEMATIC control systems used in the installation are linked to each other by a BUS cable and each of them can manage 2 heating circuits with 3-way valve and a DHW circuit (in the second part of the example, the control system manages a swimming pool and a DHW tank). BUS BUS BUS 230 V BUS 230 V VM_F0004B Operating principle The DIEMATIC m3 control panel on the master boiler manages the DIEMATIC control system via a BUS cable. The latter manages 2 heating circuits with 3-way valve. 21 230V 51 AD 199 + FM 48 + 3 3 BUS 230 V AD 220 230 V 50 Hz 18 50 9 7 8 35 7 9 9 26 24 33 25 9 32 9 30 9 29 28 64 23 9 9 11b 4 10 65 44 23 9 9 11b 4 10 65 44 23 9 9 4 10 65 9 9 11b 10 AD254 44 23 AD254 4 4 44 65 9 9 11b 10 23 17 M 36 39 M 36 39 68 16 13 C 230 Eco DIEMATIC-m3 C 230 Eco K3 BP/BL VM_F0009A 5

bar bar PRESENTATION OF THE DIEMATIC VM i. System CONTROL SYSTEM DIEMATIC CONTROL SYSTEMS COMMUNICATING WITH GENERATORS (CONTD) DIEMATIC alone or as part of a network with a single boiler or a cascade of boilers equipped with an OpenTherm (OT) interface Application scenario Management of the boiler on ON/OFF or OT according to the outside temperature Management of 2 circuits: direct or with mixing valve (circuits B and C) and 1 DHW circuit Outside sensor required Networking of 1 to 20 OpenTherm control systems with 1 to 10 generators equipped with OpenTherm AUX outlet Up to 2 remote controls per control system no. 1 no. 1 Principle interface BUS BUS BUS no. 2 interface no. 10 VM_F0008 Operating principle A network with 2 DIEMATIC control systems is managed in a cascade of boilers, each equipped with an OpenTherm (OT) interface. The first DIEMATIC control system manages the first boiler, a DHW circuit and 2 heating circuits with a 3-way valve. The second control system manages the other boilers through the AD 286 connection interface and 2 heating circuits with 3-way valve. no. 2 no. 1 BUS BUS BUS 230 V 230 V 230 V 230 V VM_F0007A 6

TECHNICAL SPECIFICATIONS INFORMATION EXCHANGED BETWEEN DIEMATIC CONTROL SYSTEMS Between interconnected DIEMATIC The information exchanged between interconnected DIEMATIC control systems is: - The outside temperature: a single sensor may be sufficient for all of the control systems; - The date and time data. Between DIEMATIC and DIEMATIC, DIEMATIC isystem control panels In addition to the parameters above, the actual thermal needs are communicated at all times to the control system on the primary loop (DIEMATIC control panel). Network A network can include up to 20 DIEMATIC control systems and, in this case, command up to 40 hydraulic circuits (heating circuits by motorised 3-way valve, direct circuits, primary circuits for DHW preparation, auxiliary circuits). INSTALLATION OF DIEMATIC CONTROL SYSTEMS All interconnected control systems must be installed in the same building. Should this not be the case, the following special provisions must be made: Length of the BUS The length of the BUS must not exceed 1200 m. Type of cable The connection of DIEMATIC control systems must be made with AD 123, AD 124 and DB 119 connecting cables available as options. Fitting the cable If the connecting cable is installed in a pipe or cable way without electrical continuity, it will be necessary to affix the connecting cable to a copper cable with a minimum cross-section of 16 mm 2 connected to the earth at both ends. Equipotentiality of the earth terminals The earth terminals in the building must be interconnected for reasons of electrical safety and compliance with regulations. Surge suppressor It will be necessary to equip the connecting cable with an RS 485 line lightning conductor at each point of exit from the building. It will be necessary to equip the electrical power supply on each control system with a mains lightning conductor. If a telephone transmitter is used, it will be necessary to equip it with a mains lightning conductor and a lightning conductor for the telephone line. 7

TECHNICAL SPECIFICATIONS The DIEMATIC control system module is particularly easy to use. Particularly owing to its large conversational display unit, backlight, it establishes a dialogue with the user by means of drop-down menus to guide him in the choice of readouts or settings that he wishes to make. Navigation between the dropdown menus is quite straightforward thanks to a rotary button. The display unit converses in plain text and, at all times, provides information on the time, the day, the various temperatures in the installation, the outside air temperature and the status of the various components in the installation (valves, pumps, etc.). For the sake of simplification, the display unit is able to recognise which circuits are actually connected and ignore those not in use. The display unit enables 3 levels of navigation: - A user level: accessible to the end user who can modify certain parameters regarding the temperatures in the various operating modes and the programming for the various comfort periods - An installer level: accessible only to the installer. The latter can use this to set the configuration of the various parameters of the installation. - An After Sales Service level: accessible only to the installer. Pre-programmed and set (date, day, time) in the factory, DIEMATIC comes ready to operate. Four different weekly programmes are memorised. Each programme can be selected directly from a drop-down menu. If, out of these 4 options, none is suitable, 4. programme can be very easily customised according to the user s wishes. PRESENTATION OF THE DIEMATIC isystem CONTROL PANEL Display unit backlit in comfort mode Graphic bar indicating the current programme for the circuit displayed - Black: comfort mode - Light: reduced mode Temperature setting key (heating, DHW, swimming pool) Operating mode selection key for heating and DHW. Summer, winter, Auto according to programming, day, night, holidays, manual Mode display (comfort, reduced, holidays, manual, Auto) Forced load key for DHW production Day/time display Display of the programme selected Access installer and After Sales Service level Keys: - To access the various menus or parameters - For programming, reset, which vary as selections are made VM_Q0006 Rotary and push setting button: - By turning it, you can scroll down the menu or modify a value - By pressing it, you can confirm a selection or value modification 8

TECHNICAL SPECIFICATIONS OPERATING PRINCIPLE The DIEMATIC control system manages up to 2 hydraulic circuits (circuit with motorised 3-way valve, direct circuit) and an auxiliary circuit by activating the pumps and, where applicable, the mixing valve(s). Connection of a room temperature sensor enables the auto-adaptability of the heating curve and correction of the room temperature on each circuit. The control system includes: - Automatic summer/winter switching (setting balance point with anti-clogging function on the pumps; optional forced summer mode with this function. - An «installation antifreeze» function activated regardless of the operating mode. - «Anti-legionella» protection for the domestic hot water circuit(s). HEATING PROGRAMMING The DIEMATIC control system comes with 4 memorised programmes. For each circuit connected to the control system, one of these programmes can be applied. Programme selection is easily done with a menu. Programme P1 is activated on start-up. Programme P2 to P4 can be customised differently for each of the circuits connected. Programming can be done day by day or in blocks of 7 days, and in 30-minute intervals, i.e. up to 48 periods per day per circuit. It is possible to go back to the standard programmes present on first start-up at any time. Below are the programming details for heating «comfort» mode in the various programmes: P1: 6 h to 22 h every day P2: 4 h to 21 h every day (e.g.: underfloor heating) P3: 5 h to 8 h and 16 h to 22 h from Monday to Friday, 7 h to 23 h on Saturday and Sunday P4: 6 h to 8 h then 11 h to 13.30 h then 16 h to 2 h from Monday to Friday, 6 h to 23 h on Saturday and 7 h to 23 h on Sunday CLOCK POWER RESERVE The clock power reserve is 2 years. After 2 years without current, only the time on the clock has to be corrected. All other values, including the programming, are saved in the memory. DISPLAY OF MEASUREMENTS Depending on the various options, circuits and corresponding sensors actually connected, the values measured by the control system can be displayed in the «MEASUREMENTS» menu: - Outside temperature - Room temperature on circuits B and C - Water temperature in the DHW tank - Water temperature in the storage tank - Water temperature in the swimming pool on circuits B and C - Water flow temperature on circuits B and C - Water temperature system flow if multi-generator - Temperature of the hot water produced by solar power TROUBLESHOOTING The DIEMATIC control system has a test programme that can be used: - To check the correct operation of all components in the installation (remote control, valve(s), pump(s), etc.); - To read the set point values calculated by the system and factored into operation of the installation; - To display the status of the logic inputs (other than the sensors); - To test the interconnections and configurations. ALARMS In the event of malfunction, the module flashes and displays an error message and a corresponding code. They are recorded in a historic. 9

TECHNICAL SPECIFICATIONS ELECTRICAL CONNECTIONS All connections are grouped in the lower section of the box in a zone designed for this purpose. The cables are inserted into the box through various push-out inlets (cable glands provided). The electrical connections are made to clearly marked terminal boxes. Important The maximum current that can be switched per outlet is 2Acos = 0.7 (450 W or 0.5 HP mechanical motor). The inrush current must be lower than 16 A. The sensor wires (very low voltage) and those carrying 230 V must be placed in different cable ways. In all cases, a minimum spacing of 10 cm must be observed. BUS connections VM_Q0007 VM_Q0008 BUS connection, interconnections between modules or DIEMATIC 3, m3, isystem Very low voltage connections, sensors, logic inputs Low voltage connections (230 V), power supply, pumps, 3-way valves, safety contacts The BUS cable(s) (packages AD 134, AD 124 and DB 119) should be connected to one of the 2 bed plates marked BUS. Connection is simply done by plugging in the mini-din connector on the connecting cable. Below, a representation of the connection terminal box: CDI C CDI B/ CDR C B S.SYST BF AF 0V + 0-10V/ E.TEL OT N L C CS N M C N L B CS N M B N L L N AUX N L ALIM 230V/ VM_F0002A Very low voltage connections (sensors, remote controls) Pictogram Description CDI C Remote control circuit C CDI B/C CDR Remote control circuit B Radio remote control - circuits B and C C Flow sensor on circuit C B Flow sensor on circuit B S.SYST System sensor BF DHW sensor AF Outside temperature sensor 0-10 V / E.TEL Remote vocal monitoring module OT OpenTherm * The safety contacts (CS): These have several functions: - A safety contact function, e.g. flow limiters underfloor heating, etc. Low voltage connections: outlet connection (heating pumps, 3-way valves, etc.) Pictogram Description C Heating pump - circuit C CS* Safety contact circuit C M C 3-way valve circuit C B Heating pump - circuit B CS* Safety contact circuit B M B 3-way valve circuit B DHW load pump DHW loop pump, burner, HP, wood-fired boiler AUX (depending on configuration) ALIM 230 V/50 Hz Electrical power supply - A control function: the bridges can be removed and replaced by pump cut-off switches; 10

CONTROL PANEL DIEMATIC VM i. System OPTIONS DIEMATIC isystem CONTROL PANEL OPTIONS 8575Q034 Outside temperature sensor - Package FM 46 Connected to the control panel, it is used to regulate the heating depending on the outside temperature. Domestic hot water sensor - Package AD 212 This is used for regulating the DHW temperature as a priority and programming of domestic hot water production with an independent calorifier. (The TA connector in package is not to be used). 8518Q022 GT220_Q0002 Outlet sensor downstream of the valve - Package AD 199 This sensor is required to connect a circuit with mixing valve. AD 253/254 AD 252 8666Q172A CALENTA_Q0005 CDI D. isystem interactive remote control - Package AD 254 CDR D. isystem interactive radio remote control (without transmitter / receiver radio) - Package AD 253 Radio boiler module DIEMATIC isystem (transmitter / receiver) - Package AD 252 These are used to change heating parameters from the DIEMATIC isystem control panel from the room in which they are installed. In addition, they enable the self-adaptability of the heating regime for the circuit concerned (one CDI D.iSystem or CDR D.iSystem per circuit). In the case of the CDR D.iSystem, the data are transmitted by radio waves from the place where the CDR D.iSystem is installed to the transmitter/ receiver box (package AD 252) placed close to the boiler. 8575Q037 82Q020 Simplified remote control with room sensor - Package FM 52 This is used from the room in which it is installed to change the set point from the DIEMATIC isystem panel: BUS connection cable (length 12 m) - Package AD 134 The BUS cable is used to make the connection between 2 boilers fitted with the DIEMATIC isystem control panel in a cascade installation, as well as - It allows a +2,5/-2,5 deviation of the room T set point. It is also used to enable the self-adaptability of the heating curve for the circuit concerned (1 remote control per circuit). the connection of a DIEMATIC VM control unit or a telemonitoring network transmitter. MCA_Q0012 Sensor for storage tank - Package AD 250 Includes 1 sensor for a storage tank with a boiler fitted with a DIEMATIC isystem control panel. AD 251 AD 252 8666Q172A 8575Q034 Radio outside temperature sensor - Package AD 251 Boiler radio module (radio transmitter) - Package AD 252 The radio outside temperature sensor can be If this sensor is used: delivered as optional equipment for systems in - With a wire connection remote control (AD 254 or which the installation of the external wire connection FM 52), it is necessary to order the Boiler radio sensor delivered with DIEMATIC isystem control module (AD 252). panel would be too complex. - With a radio remote control (AD 253), already combined with a boiler radio module (AD 252), control of a second module is not necessary. 11

CONTROL PANEL DIEMATIC VM i. System OPTIONS VM_Q0003 Wall-mounted box OpenTherm/Modbus Interface - Package AD 286 Needed to control a boiler cascade equiped with OT controller (1 board per boiler). VM_Q0002 OpenTherm/Modbus Interface - Package AD 287 Needed to manage a cascade of boilers equiped with OT controller. The board should be installed directly in the boiler. Intermodule connecting cable - length 1.5 m - Package AD 124 This is used for the interconnection of two DIEMATIC wall-mounted control systems. Legend 8801Q022 8199Q063 3 Safety valve 3 bar 4 Pressure gauge 6 Air separator 7 Automatic air vent 8 Manual air vent 9 Isolation valve 10 3-way mixing valve 11 Electronic heating pump 11a Electronic heating pump for direct circuit 11b Electronic heating pump for circuit with mixing valve 13 Flush valve 16 Expansion tank (except MCA 35) 17 Draining valve 18 Heat circuit filling 21 Outside sensor 23 Outlet temperature sensor after mixing valve 24 Primary inlet on the DHW tank exchanger BUS connecting cable - long. 40 m - Package DB 119 This is intended to replace either the 12 m or the 1 m BUS cable when these turn out to be too short. 25 Primary outlet on the DHW tank exchanger 26 Domestic water load pump Non-return valve 28 Domestic cold water inlet 29 Pressure reducer 30 Sealed safety device calibrated to 7 bars (1) 32 (Optional) DHW loop pump 33 DHW temperature sensor 35 Disconnecting cylinder (available as an option - see page 8) 36 Motorised isolating valve 39 Injection pump 44 65 C limiter thermostat with manual reset for underfloor heating 46 3 way-directional valve with motor reversing 50 Disconnector 51 Thermostat valve 61 Thermometer 64 Radiator circuit (gentle heat radiators, for example) 65 Low temperature circuit (underfloor heating, for example) 67 Manual valve 68 Condensates neutralisation system 73 Limiter thermostat 75 Pump for sanitary use 79 Primary outlet of the solar exchanger 80 Primary inlet of solar exchanger 84 Stop valve with releasnon return valve 85 Solar circuit pump 87 Safety valve sealed and calibrated to 6 bars 88 Solar expansion tank 89 Recepient for heat transfer fluid 109 Thermostatic mixing valve for domestic hot water 112a Collector sensor 112b Solar tank sensor 114 Solar circuit drainage valve (note: propyleneglycol) 123 Cascade flow sensor (to connect to the slave boiler) 126 Solar regulator 130 Degasser with manual purge (Airstop) 131 Champs de capteurs 132 Station solaire complète avec régulation DIEMASOL 145 Vanne de commande de la batterie de sécurité 146 Module thermostatique de réglage de la température du circuit retour (1) mandatory, in compliance with safety directives 01/2012 300028142 347.555.559 Strasbourg Companies Register Document not contractually binding - Printed in France - OTT Imprimeurs 67310 Wasselonne - 1113899 DE DIETRICH THERMIQUE S.A.S. with corporate capital of 22 487 610 57, rue de la Gare - F - 67580 Mertzwiller Tel. +33 3 88 80 00 - Fax +33 3 88 80 99 www.dedietrich-heating.com