Pneumatic Heat Press. Revision: 3 Operators Manual

Similar documents
Model PT-05 Model PT-06

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Omega Series 1000 Operators Handbook

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

Studio Mug. Operators Handbook. Rev A - 24/08/ a.adkins and sons limited. all rights reserved

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

O P E R A T O R S M A N U A L

E32M CONVECTION OVEN SERVICE MANUAL. Revision 1/F

OPERATING & SERVICE INSTRUCTION MANUAL FOR

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

Frequently Asked Questions: Maytag (PD) washers, dryers & Stack Units

Operating Instructions

AD-115ES Parts Manual

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

E25 CONVECTION OVEN E25MS CONVECTION OVEN SERVICE MANUAL

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

HT-600D. (either domestic or foreign), please keep a copy of their sales invoice showing the serial

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Portable Refrigerator

NXM2G Installation and Operating Manual

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Popcorn Warmer Cabinet

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Alpha Mk. 6 Industrial Heat press. operators handbook

GEYSERWISE INSTRUCTION MANUAL

Troubleshooting Guide

Quality Endorsed Company ISO 9001 Lic. No. 5403

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

SpeedClave Steam Sterilizers

E32 CONVECTION OVEN SERVICE MANUAL

Door Release Power Supply

Digital Knight 16x20 Automatic Digital Swinger

E32 CONVECTION OVEN SERVICE MANUAL -1- Revision 1/F3508

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Quickheat 30 weather compensated boiler control

HT-2 / 9600 Series Control Contents

INTELLI-VAC 14 INTELLI-VAC 18

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

E35 CONVECTION OVEN SERVICE MANUAL

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

INSTALLATION GUIDE NZ AU GB IE

OWNER S MANUAL WARRANTY CONTENTS. For Models: SwingMan 20D TWIN SwingMan 25D TWIN

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

BX444-Mc Gas Detector

CA5000 Liquid CO 2 Freezer Backup System

Easy-Lam School Budget Roll Laminator

MBCE-110/230UV Flame Sensor Module

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

DISPOSER CONTROL CENTER

To suit Daikin FDY "F" Series. (and other models incorporating BRC1C61 Remote Controller)

Manual P/N M0MG32MS. Revision 6/F3587 February, 2005

STATUS ALARM HISTORY ALARM RESET

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

FLUEBOOST. flueboost 350 gas fire model

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

AD-30V/AD-50V Parts Manual Phase 7/Dual Timer

5. CBS Alarms Responding to a CBS Alarm Understanding the Alarm Condition A-CBS-008 Circuit Breaker Sentinel Page 109 of 156

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Parts and Service Manual

Public Safety DAS Annunciator Panel

Drying Cabinet With Timer

ML-758 Parts Manual. Dual Timer/Phase 7 OPL with FSS Options

FORMATIC Instruction Manual

Non-Programmable Digital Thermostat

RAM 50 Series Operation Manual

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

L A signature series TA T N E RE O, A L L A T S IN

User Instruction Manual

TL-105 COLUMN HEATER

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

P6500W Air Dryer User s Guide

WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM?

ML-758 Parts Manual. Phase 7 / Non-Coin / Dual Timer with F.S.S. Options

Manual Examination Table

Fix Any Problem in Ten Minutes the Maintenance & Programming Manual for the digital EzPress & digital PopUpPress with EzWizard Software version 2.

USER S OPERATING AND INSTRUCTION MANUAL

Pump-Down Controller MODEL 4052

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

DISPOSER CONTROL CENTER

E26 CONVECTION OVEN SERVICE MANUAL. Revision 1/F

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

DEL MAR SULFURELITE Hydrogen Sulfide Analyzer

RadioLINK Alarm Base. Instructions. Model: Ei168RC

Transcription:

Pneumatic Heat Press Revision: 3 Operators Manual Wader Labelling Systems Ltd 2003

Location and Set-up. The press must be located near to a filtered air supply and a 240v singlephase mains supply. Ensure that the machine is fixed on a solid bench / table away from dust and sunlight. Connect the foot switch to the plug on the side of the press. The air fitting on the back of the heat press is a 1/8" female thread coupling; air intake pressure must be no more than 100PSI. Operation Before switching on press ensure that air is connected to the machine. Switch press on using the black button on the side of the machine. When you switch on or reset the press, the control unit will recalculate the current temperature of the heat plate. The controller will disable operation of the sealing cycle until the temperature is correct. When the light on the controller is under the lettering OUT2 is illuminated, this indicates that the pre-programmed temperature that is acceptable to seal down labels has been reached. The second light under OUT1 indicates if power is been applied to the element (i.e. element is heating up). With the air supply set at approx. 80 psi, the temperature ok at about 204'C set the timer unit to the desired dwell time, place the article to be marked on the silicone pad along with the label / transfer, remove your hands away from the sealing pad area at all times and actuate the foot switch and keep pressed down until the heat plate touches the garment / pad the timer will now actuate (operator may let go of the foot switch) and keep the sealing cycle going for the predetermined time. Once the dwell time has elapsed the platen will raise automatically. Controls The temperature controller fitted to this machine is microprocessor based with a large bright 3-digit display. Internal programming parameters are carried out at the factory but the operator may change the pre-set temperature and the temperature disable function if required.

Temperature Change. 1) To change the pre-set temperature (temp that the press is constantly running at) press and hold the top left thermometer button. The currently stored temperature will now be displayed. 2) Whilst holding the button press the arrow keys on the right hand side of the controller until required temperature is reached. 3) Release all the buttons and the temperature will be stored. Temp / Operation Disable Function. This function allows the operator to define a temperature that the machine will become inoperative. Example: - if the labels you are applying must be sealed down at a temperature no less than 195C the control unit will disable the foot switch if the temperature is below this figure so that the operator cannot actuate the machine until the correct temp has been reached. 1) Press and hold the L2 button. This will display the current setting. 2) Whilst holding this key press the arrow buttons to set the required temp. Please note that this setting must be lower than the temperature setting or the machine will always be disabled! Air Pressure The air pressure that the machine operates at can be adjusted by turning the large black knob on the left-hand side of the machine. The knob pulls out slightly and can be turned to increase / decrease pressure, once the desired pressure has been reached press the knob back in to lock it into position. If the machine is used on low air pressures tape may not seal correctly. We recommend a setting of 80 PSI.

Problems Press inoperative (will not switch on) - Fuse blown check internal DIN mounted fuse. Platen cover jammed up & not making contact with safety switches. Heat plate not getting hot - Open circuit element. Probe failure the control unit is programmed to shut off power In the case of probe failure. Lack of pressure.- Check air supply and regulator on side of machine. Stop Circuit / Emergency stop To switch the machines off simply press the large emergency stop button on the front. The power supply circuit on this machine runs through an isolating circuit, when the operator depresses the ON button a relay latches and holds power throughout the machine, a split second interrupt in the power supply will cause the relay to de-energise thus completely isolating positive and negative circuits in the machine. To reset the machine or switch it back on simply press the ON button. The platen cover and emergency stop switches are wired into the same circuit. STOP Button

Platen Cover (CHECK OPERATION PERIODICALLY) The platen cover fitted to the press is spring loaded with three independent switches to detect any obstructions when the heat plate comes down. The three switches press against the top of the cover any movement against the cover making it lift more than approx. 2mm will release the switch thus resulting in the power supply circuit to be broken and isolated. THE HEAD OF THE MACHINE WILL RETURN TO THE START POSITION. Press the ON button to restart the machine. The height from the top heat plate to depress the switch roller is 35mm; the switches can be independently adjusted via the slot on the switch mounting plate. Please note that if the switches are not making good contact with the platen cover false readings may occur, therefor all switches must be adjusted correctly. Adjust the switches for platen cover emergency stop. A m3 torx screw located at the side of the switch secures the switch after the desired height has been determined by lifting the cover a suitable amount before power is cut off.

Components Identification Timer Unit & Pressure Regulator Isolating Relay Solenoid Valve Emy. Stop / Cylinder / Temp Control

Parts list For Revision 3 Machines MTW-12 - Microprocessor control unit with digital display. 1752 H - Timer unit. 260-662 - 6 Digit counter with reset 240VAC Norg-rev:3 - Solenoid valve Nug 40 inc. sol A30-norg - Valve cable. Switches A01-1 - Emergency stop (body & contact) A02-1 - Mains Switch BLACK A03-1 - Foot switch (imo type) A05-3 - Safety Guard micro switches V3 3 off Electronics A06 - Transformer for MTW12 Control Unit A08 - Power light A09-1 - Timer connector 8 PIN. A10 - Cable gland nylon A11 x? - DIN rail connectors various. A27 - Power on isolating relay A36 - Foot Switch connector complete Pneumatics A13-norg - Pressure indicator PSI / Bar A14-norg - Pressure Regulator Valve A17 - Air tubing 6MM O/D 3mtr length A31-norg - 63mm X 150mm cylinder Heat Plate GSW 14 - Element 500W @ 240VAC. A18 - Silicone pressure pad. GSW 22 - RTD probe 2 wire. A24 (state size) - PTFE for heat plate. A25-3-norg - Instruction Booklet. A32 - Upper heat plate coupling to cylinder inc. m/switch mounts & Darvic insulators. A33 - Tracking rod. A34 - Tracking rod gland A35 - Microswitch timer actuator bush (on tracking rod) A37 - Flexible conduit 20" inc. internal bushes. A38 - Platen cover springs 4 off A39 - Internal & External platen cover bushes set of 8.

Application details for Wader Products. Your press should have the following settings :- Temperature: 205'C Gauge Pressure: 80 PSI (approx. 5.5-6.3 Bar) Time Dwell: 8 seconds. Guarantee This press is guaranteed to be free from defects in material and workmanship ** for a period of 12 months from the proven date of delivery or installation. Should, in our opinion, any part of this press be defective in materials or workmanship it will be replaced or repaired free of charge (excluding and travelling costs / carriage costs which will be charged at our discretion) provided that the press has been installed and operated in the correct manner and not subjected to misuse. A charge will be made for any costs incurred if a reported fault on the press is found to be due to incorrect installation, operation and/or incorrect materials being used, as it is the responsibility of the press user to ensure the suitability of the materials operating through the press. ** Exclusions- Pressure Pad A18, PTFE A24 This machine was designed for the application of heat seal Tape & Transfers only. It is not intended for use in any other respect. Keep hands clear of heat plate when operating the foot switch Factory Set-up:- Temperature = L2 Disable = Seal & Release Speed =