Internal Wall Mounted and Internal Floor Standing Balanced and Conventional Flues clean heat technology Wall Mounted Balanced Flues 12/16 & 16/25 Low Level Left, Rear and Right 125 LLCW-125 VTLC-125 Height 1323 to 2343 223 to 363 0 to 97 1323 to 2343 1323 to 2343 High Level Left, Rear and Right 125 HLC-125 Height 778 to 1338 0 to 97 223 to 363 Vertical Flat Roof Vertical Pitched Roof 778 to 1338 Balanced Flue accessories and extensions EXT 300 300mm EXT 600 600mm Terminal Guard All models EXT 900 High Level Left High Level Rear High Level Right 45 Degree Bends vertical section only Flue Extensions
Floor Standing Balanced Flues 12/24 & 24/30 12/24 Low Level Left, Rear and Right 125 Ø 125mm LLC-125 Ø 125mm VTLC-125 Height 12/24 2070 to 3090 24/30 2179 to 3199 24/30 Low Level Left, Rear and Right 125 Ø 125mm LLCW-125 Vertical Flat Roof Vertical Pitched Roof Conventional Flue Systems High Level Left, Rear and Right 125 HLC-125 Height 12/24 1525 to 2085 24/30 1634 to 2194 98mmØ Liner 85mmØ CFS6/CFS9/CFS12 Extensions EXT 500/1000 Liner Length 6/9/12 metres Liner length available in 6, 9 or 12 metre lengths. 85 EXT 1000 1000mm 245mm to 460mm 98 EXT 500 500mm Flue Extensions 98mmØ High Level Left High Level Rear High Level Right Part L Compliant The thermeco Brand of Boilers comply with Building Regulations Part L and are SEDBUK approved. GAH (Heating Products) Ltd T 01394 421160 F 01394 421170 E mail@gah.co.uk www.gah.co.uk
External Wall Mounted 12/16 & 16/25 clean heat technology External Floor Standing 12/24 & 24/30 Band A SEDBUK Range 90% and above Welcome to the new generation of GAH thermeco High Efficiency il Fired Boilers, that offer the ultimate choice for quality, reliability, efficiency and quietness in operation. The thermeco design utilises clean heat condensing coil technology ensuring optimum high efficiency together with flexibility of siting which is further enhanced by the extensive range of round telescopic balanced flue systems. With responsive after sales support and dedication to customer satisfaction thermeco is the number one choice to meet your needs for oil fired heating. GUARANTEE - PARTS AND LABUR 2 year burner components - excluding nozzle 3 year optional extended warranty 5 year heat exchanger Dimensions Height Width Depth Wall mounted 12/16 16/25 992mm 572mm 340mm Features 992mm 572mm 340mm Floor Standing 12/24 24/30 855mm 555mm 855mm 555mm SEDBUK band A approved Clean Heat Technology Stainless steel condensing heat exchanger Available as standard or system model Full door with internal control panel Front servicing High performance Max burner Integral flue system Frost protection included Suitable for fully pumped systems only
Technical Information External Wall Mounted External Floor Standing 12/16 16/25 12/24 24/30 utput (BTU/hr x 1000) 40 to 55 55 to 85 40 to 80 80 to 100 Standard boiler weight 90Kgs 121Kgs 121Kgs 139Kgs System boiler weight 95Kgs n/a 129Kgs 147Kgs Water content (litres) 17 litres 21 litres 22 litres 28 litres Water connections 3/4 BSP 3/4 BSP 3/4 BSP 3/4 BSP Fit below worktop n/a n/a n/a n/a Front servicing Yes Yes Yes Yes Water cooled base Yes Yes Yes Yes Balanced flue size Integral Integral Integral Integral Conventional flue size n/a n/a n/a n/a Frost protection fitted Yes Yes Yes Yes il system 2 pipe 2 pipe 1 pipe 1 pipe Fuels type 28 Sec 28 Sec 28 Sec 28 Sec Suitable for fully pumped systems only Yes Yes Yes Yes perating temperature Electricity supply Maximum operating pressure 3 Bar 3 Bar 3 Bar 3 Bar Conventional flue chimney draft limit n/a n/a n/a n/a External Wall Mounted Balanced Flues 572 External Floor Standing Balanced Flues 900 Notes & Guarantee The guarantee is only valid if the boiler is installed in accordance with the Technical Installation Manual and commissioned within 10 working days of installation by an approved/competent engineer using the required test equipment. The completed guarantee form must be returned to GAH Heating Products. 992 855 SEDBUK is the average annual efficiency achieved in typical domestic conditions, making reasonable assumptions about pattern of usage, climate, control and other influences. The new boiler Building Regulations that came into effect on 1st April 2007 stipulate that only oil-fired condensing boilers rated in Band A or Band B (A being the highest and most efficient) can be installed. 700 555 340 Part L Compliant The thermeco Brand of Boilers comply with Building Regulations Part L and are SEDBUK approved. GAH (Heating Products) Ltd T 01394 421160 F 01394 421170 E mail@gah.co.uk www.gah.co.uk
Internal Floor Standing 12/24 & 24/30 clean heat technology Band A SEDBUK Range 90% and above Welcome to the new generation of GAH thermeco High Efficiency il Fired Boilers, that offer the ultimate choice for quality, reliability, efficiency and quietness in operation. The thermeco design utilises clean heat condensing coil technology ensuring optimum high efficiency together with flexibility of siting which is further enhanced by the extensive range of round telescopic balanced flue systems. With responsive after sales support and dedication to customer satisfaction thermeco is the number one choice to meet your needs for oil fired heating. GUARANTEE - PARTS AND LABUR 2 year burner components - excluding nozzle 3 year optional extended warranty 5 year heat exchanger Dimensions Height Width Depth Features 12/24 850mm 480mm 585mm 24/30 850mm 480mm 585mm SEDBUK band A approved Clean Heat Technology Stainless steel condensing heat exchanger Available as standard or system model Conventional flue system available Full door with internal control panel Front servicing High performance Max burner Circular telescopic balanced flue system Suitable for fully pumped systems only
Technical Information 12/24 24/30 utput (BTU/hr x 1000) 40 to 80 80 to 100 Standard boiler weight 119Kgs 137Kgs System boiler weight 127Kgs n/a Water content (litres) 22 litres 28 litres Water connections 3/4 BSP 3/4 BSP Fit below worktop Yes No Front servicing Yes Yes Water cooled base Yes Yes Balanced flue size 125mm 125mm Conventional flue size 86mm 86mm Frost protection fitted n/a n/a il system 1 pipe 1 pipe Fuels type 28 Sec 28 Sec Suitable for fully pumped systems only Yes Yes perating temperature Electricity supply Maximum operating pressure 3 Bar 3 Bar Conventional flue chimney draft limit Minimum 1.2mm H20 Minimum 1.2mm H20 Accessories and Flue Extensions Floor Standing Balanced Flues 12/24 Low Level Left, Rear and Right 125 LLC-125 24/30 Low Level Left, Rear and Right 125 LLCW-125 High Level Left, Rear and Right 125 HLC-125 Height 12/24 1525 to 2085 24/30 1634 to 2194 EXT 300 300mm EXT 600 600mm 45 Degree Bends vertical section only Terminal Guard All models Flue Extensions EXT 900 High Level Left High Level Rear High Level Right VTLC-125 Height 12/24 2070 to 3090 24/30 2179 to 3199 Notes & Guarantee The guarantee is only valid if the boiler is installed in accordance with the Technical Installation Manual and commissioned within 10 working days of installation by an approved/competent engineer using the required test equipment. The completed guarantee form must be returned to GAH Heating Products. SEDBUK is the average annual efficiency achieved in typical domestic conditions, making reasonable assumptions about pattern of usage, climate, control and other influences. The new boiler Building Regulations coming into effect on 1st April 2007 stipulate that only oil-fired condensing boilers rated in Band A or Band B (A being the highest and most efficient) can be installed. Part L Compliant The thermeco Brand of Boilers comply to Building Regulations Part L and are SEDBUK approved. Vertical Flat Roof Vertical Pitched Roof GAH (Heating Products) Ltd T 01394 421160 F 01394 421170 E mail@gah.co.uk www.gah.co.uk
Internal Wall Mounted 12/16 & 16/25 clean heat technology Band A SEDBUK Range 90% and above Welcome to the new generation of GAH thermeco High Efficiency il Fired Boilers, that offer the ultimate choice for quality, reliability, efficiency and quietness in operation. The thermeco design utilises clean heat condensing coil technology ensuring optimum high efficiency together with flexibility of siting which is further enhanced by the extensive range of round telescopic balanced flue systems. With responsive after sales support and dedication to customer satisfaction thermeco is the number one choice to meet your needs for oil fired heating. GUARANTEE - PARTS AND LABUR 2 year burner components - excluding nozzle 3 year optional extended warranty 5 year heat exchanger Dimensions Height Width Depth Features 12/16 830mm 580mm 310mm 16/25 830mm 580mm 310mm SEDBUK band A approved Clean Heat Technology Stainless steel condensing heat exchanger Available as standard or system model Conventional flue system available Full door with internal control panel Front servicing High performance Max burner Circular telescopic balanced flue system Suitable for fully pumped systems only
Technical Information 12/16 16/25 utput (BTU/hr x 1000) 40 to 55 55 to 85 Standard boiler weight 89Kgs 120Kgs System boiler weight 94Kgs n/a Water content (litres) 17 litres 21 litres Water connections 3/4 BSP 3/4 BSP Fit below worktop n/a n/a Front servicing Yes Yes Water cooled base Yes Yes Balanced flue size 125mm 125mm Conventional flue size 86mm 86mm Frost protection fitted n/a n/a il system 2 pipe 2 pipe Fuels type 28 Sec 28 Sec Suitable for fully pumped systems only Yes Yes perating temperature Electricity supply Maximum operating pressure 3 Bar 3 Bar Conventional flue chimney draft limit Minimum 1.2mm H20 Minimum 1.2mm H20 Wall Mounted Balanced Flues Low Level Left, Rear and Right 125 LLCW-125 0 to 97 High Level Left, Rear and Right 125 HLC-125 Height 778 to 1338 0 to 97 778 to 1338 223 to 363 223 to 363 Accessories and Flue Extensions EXT 300 300mm EXT 600 600mm High Level Left High Level Rear High Level Right Terminal Guard All models EXT 900 VTLC-125 Height 1323 to 2343 45 Degree Bends vertical section only Flue Extensions Notes & Guarantee The guarantee is only valid if the boiler is installed in accordance with the Technical Installation Manual and commissioned within 10 working days of installation by an approved/competent engineer using the required test equipment. The completed guarantee form must be returned to GAH Heating Products. SEDBUK is the average annual efficiency achieved in typical domestic conditions, making reasonable assumptions about pattern of usage, climate, control and other influences. The new boiler Building Regulations coming into effect on 1st April 2007 stipulate that only oil-fired condensing boilers rated in Band A or Band B (A being the highest and most efficient) can be installed. 1323 to 2343 1323 to 2343 Part L Compliant The thermeco Brand of Boilers comply with Building Regulations Part L and are SEDBUK approved. Vertical Flat Roof Vertical Pitched Roof GAH (Heating Products) Ltd T 01394 421160 F 01394 421170 E mail@gah.co.uk www.gah.co.uk