Ventilation Solutions Laundries. fantech

Similar documents
Fresh and clean... even when it isn't laundry time.

Ventilation Solutions Radon Mitigation

Air in Motion. Fan Guide Book. January 2001 FB-0101

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

DBF 4XL Dryer Booster Fans

Air in Motion. Fan Guide Book February 2004 FB-0204

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

5 year fan housing and motor warranty

Makeup Air Systems What goes out, must come in

Exhaust Makeup Air System What goes out, must come in

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

SECTION AIR DUCT ACCESSORIES

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Product Catalog Commercial Solutions US Edition

Outside Air Requirements... SOLVED!

Residential Heat & Energy Recovery

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Product Catalog Commercial Solutions US Edition

Chilled Water DOAS Fan Powered Terminal Units

SAFETY AND INSTALLATION MANUAL MODEL 8100

SECTION (15820) - AIR DUCT ACCESSORIES

READ AND SAVE THESE INSTRUCTIONS

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

SUBMITTAL SCHEDULE & DATA

Ventilation Solutions IAQ Canada

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

MODEL CDB8 INSTALLATION INSTRUCTIONS

Dear Concessionaire,

Residential Fans & Air Purifiers

HS Series Installation & Operating Instructions RadonAway

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ASX7-5-IOM-3 J

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

HS Series Installation & Operating Instructions RadonAway

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Please Read and Save These Instructions.

INSTALLATION AND SERVICE MANUAL

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

ASX7-4-IOM-6 J

Get it Right the First Time Avoid These Commonly Cited Errors

SECTION AIR HANDLING UNIT

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

INSTALLATION AND SERVICE MANUAL

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

Ventilation Solutions Kitchens

CVS Model Inline Multi-Port Ventilators

Light commercial models

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

CLe-series Dishwashers

ENERVEX RSV CHIMNEY FAN

Installation Instructions

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Ventilation Solutions IAQ Canada

BEST PRACTICE RECOMMENDATIONS

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

Indirect Gas-Fired Make-Up Air

Featuring Vent Lights and Premium Grilles

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

ENERVEX GSV GREASE FAN

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

CERV Fan and Duct Sizing Information

Inspection Checklist Residential Mechanical Rough In July 2016

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

UNDERSTANDING SAFETY CABINETS

Smart Choice Electric Dryer Installation Kit

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION MANUAL CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) MODEL CERV-001-PARTA, CERV-001-PARTB

Ventilation Solutions. Bathrooms

Sizes. Colors. Features

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Indoor Air Quality Product Brochure.

Installation Instructions Exhaust Fan With Light

Residential Fans & Air Purifiers

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Transcription:

Ventilation Solutions Laundries

2 Laundries A New Day - and a New Name for Dryer Exhaust Fans Remember the good old days when laundry spaces were designed so that clothes dryers could be vented directly through an exterior wall with just a few feet of straight duct? Those days are over. Influenced by the latest laundry room trends (including proximity to bedrooms, multi-function capability, elaborate storage and fixtures, etc.) builders and contractors are faced with a challenging task to provide proper and effective dryer ventilation. FC 4 Mounting clamps Indicator panel

Laundries 3 Dryer Exhaust Duct Power Ventilator DEDPV-705 Dryer location preferences often result in longer dryer exhaust duct runs with multiple bends that reduce dryer efficiency, extend drying time and interfere with a builder s ability to comply with the building code. A properly applied dryer exhaust fan, preferably one that is UL Listed, may be the only solution that makes everyone happy including the home inspector and the local fire chief. The 202 International Residential Code (IRC) is pretty specific when it comes to dryer exhaust venting. A dryer exhaust duct system cannot exceed 35 feet from the dryer location to the wall or roof termination. Each 90-degree elbow reduces this maximum allowable length by 5 feet. Additionally, each dryer has its own specifications for exhaust duct length (often considerably shorter than 35 feet). Contractors should refer to the dryer manufacturer s instructions to make sure the dryer exhaust duct length does not exceed a particular model s capability. Given these restrictions, it is likely that dryers located in interior spaces will exceed either the IRC s or the dryer manufacturer s limits on duct length. For years, dryer exhaust fans have been successfully used in homes and multi-family buildings with long dryer exhaust duct runs. Many homeowners, previously burdened with long drying times and perpetually damp clothes, have been delighted with the results. Underwriters Laboratories (UL) has developed a supplement to UL705 specifically for fans used for dryer exhaust and has given these fans a new name: Dryer Exhaust Duct Power Ventilator (DEDPV).

4 Laundries MORE THAN JUST A DRYER EXHAUST FAN.. Model DEDPV-705 allows for 4" dryer exhaust duct runs up to 30 feet and is UL listed per the DEDPV Supplement to UL Standard 705. Model DEDPV-705 is equipped with an advanced pressure sensing circuit, LED indicator display panel, temperature limit device and fast clamps for easy installation and maintenance.

Laundries 5 IT'S A UL LISTED DEDPV

6 Laundries Distinguishing features between DEDPVs and other dryer exhaust fans While fans of another name may be installed in dryer exhaust applications (at least for now) UL has announced that all Dryer Exhaust Duct Power Ventilators DEDPV products manufactured after July 3, 202 must comply with the supplementary DEDPV requirements of UL705. The UL testing standards for DEDPV s help to ensure that dryer exhaust fans can safely and effectively assist the ventilation of a residential capacity dryer. The standard s tests prove functionality of required safety features, provisions for maintenance, proper air velocities for lint management, etc. UL s DEDPV standard has established a baseline for dryer exhaust fans. Authorities Having Jurisdiction can now require UL Listed DEDPVs for installations in their communities. As well, architects and engineers can specify UL Listed DEDPVs for their projects, knowing that the safety of these installations is backed by a globally-recognized, independent testing and standards company. DEDPVs are most notably differentiated from other dryer exhaust fans by these features: DEDPV fan housings must be metal, never plastic. A DEDPV must also shut down in the event of a dryer fire, so as not to facilitate the spread of fire in the home. A DEDPV must automatically energize when the dryer is operated. An integral pressure switch may be used to sense dryer operation and energize the fan. A DEDPV must indicate proper fan operation to the dryer operator as well as notify the dryer operator in the event of a fan failure.

DEDPV-705 Dryer Exhaust Duct Power Ventilator Laundries 7 UL Listed as a DEDPV under UL705 Indicator panel for fan operation is included Temperature limit device shuts down the fan in case of a dryer fire Airtight, galvanized steel housing ensures no leakage into the building Integral pressure switch for automatic operation Maintains,200 FPM air velocity: lint is entrained in the air flow The Fantech dryer exhaust duct power ventilator has been specially designed to solve the problems caused by long duct runs on clothes dryers. When the dryer is on, Fantech's patented pressure sensing switch automatically turns the DEDPV on. The DEDPV will turn itself off after the dryer stops. The wall-mounted indicator panel with a low voltage LED display lets the dryer operator know that the DEDPV is operating properly. The panel will also alert the dryer operator of problems such as no power, blocked duct, locked motor rotor and low speed conditions. A 50 foot control cable is included to connect the indicator panel to the DEDPV. The system can be used to effectively exhaust a 4 inch dryer duct run up to 30 feet in length. Specification data Model Duct size Rated power Voltage / phase Max. amps 0.0 P s 0.2 P s 0.4 P s 0.6 P s 0.8 P s.0 P s Shipping weight inch W V / ~ A cfm lbs DEDPV-705 4 83 20 / 0.73 70 50 34 9 03 86 0 46005 Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG. Item # Dimensions 3 7/ 8 2 6 5/ 6 Cleaning the dryer exhaust fan is now easier and quicker. Removable duct sleeves provide for easy access to the duct and fan impeller. 3 7/ 8 Dimensional information is in inches.

8 Laundries DBF Series Dryer Exhaust Fans DBF 4XLT DBF 4XL and DBF 4XLT Airtight, galvanized steel housing ensures no leakage into the building Maintains,200 FPM air velocity to entrain lint in the flowing duct Pressure switch to activate the fan when the dryer is on 5 / 2 -foot electrical cord with plug and mounting bracket DBF 4XL Both models DBF 4XL and DBF 4XLT are dryer exhaust fans with backward inclined impeller fan blades, which allow lint to pass through the fan. These models can be used to provide dryer exhaust in duct runs up to 30 feet in length. The DBF 4XLT model also includes a quick connect / disconnect fast clamp, and wall-mount indicator panel. The LED light on the panel lets the dryer operator know the fan is working properly. DBF 0 Maintains,200 FPM air velocity to entrain lint in the flowing air Pressure switch to activate the fan when the dryer is on DBF 0 The DBF 0 dryer exhaust fan is engineered of thermoplastic resin. It can be used on dryer duct runs up to 08 feet in length. The fan s backward inclined impeller blades allow lint to pass through the fan. The fan can be mounted in any orientiation at any point along the duct run and its straight-through air flow design allows for easy installation. Specification data Model Duct size Rated power Voltage / phase Max. amps 0.0 P s 0.2 P s 0.4 P s 0.6 P s 0.8 P s.0 P s Shipping weight inch W V / ~ A cfm lbs DBF 4XLT 4 83 20 / 0.73 70 50 34 9 03 86 0 40275 DBF 4XL 4 83 20 / 0.73 70 50 34 9 03 86 0 590 DBF 0 4 80 20 / 0.72 67 50 33 3 88 63 9 95900 Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG. Dimensions Item # DBF 4XLT DBF 4XL DBF 0 37/8 3 7/ 8 6 5/ 6 3 7/ 8 6 5/ 6 9/2 /4 2 2 3 7/ 8 Dimensional information is in inches. 3 7/ 8 2/2 9/2

RVF 4XL Exterior-Mount Fan for Dryer Exhausting Laundries 9 RVF 4XL Galvanized steel housing features powder-coat finish Mounts on the exterior side wall of the building Fantech s popular exterior-mount exhaust fan with white, powdercoated metal housing can be used for dryer exhausting when paired with the accessory DB0 pressure switch (purchased separately). The accessory pressure switch automatically energizes the fan when the dryer is operated. Ideal for condos and apartments as well as homes. Effective for duct runs up to 30 feet in length. Specification data Model Duct size Rated power Voltage / phase Max. amps 0.0 P s 0.2 P s 0.4 P s 0.6 P s 0.8 P s.0 P s Shipping weight inch W V / ~ A cfm lbs RVF 4XL 4 92 20 / 0.84 93 72 54 36 8 9 0 4004 Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG. RVF Series performance is shown with ducted inlet. Item # E Dimensions Model A B C D E RVF 4XL 3 7 /8 0 /4 3 6 2 3 /4 Dimensional information is in inches. A Air flow C D B

0 Laundries Accessories for Dryer Exhaust Fans DBLT 4W Lint Trap for Dryer Exhaust Fans Galvanized metal lint trap for dryer exhausting applications. Use when duct length between dryer and exhaust fan is less than 5 feet. Fits 4-inch duct and 2 x 6 construction. Features pull out a white pull-out door with a view window with attached removable lint filter for easy cleaning and /2 flange for flush mount installation. The lint trap complements all Fantech dryer exhaust fans. Specification Data Model Duct Size, inch Accessibility Weight, lbs Item # DBLT 4W 4 Door 4 46000 DB 0 Pressure Switch Provides fully automatic operation of dryer exhaust fan. Fan runs for 0 minutes when positive pressure is sensed in the duct line then shuts off and turns on again as needed. The switch is required for use with fan model RVF 4XL when used in a dryer exhaust application. Specification Data Model Voltage, V Max Current, A Weight, lbs Item # DB 0 20 2 40 FC Fast Clamps Our Fast Clamps facilitate the installation and removal of fans for service and cleaning. Made from galvanized sheet steel and fitted with an / 3 neoprene lining, which suppresses vibration and ensures a tight fit. The mounting clamps are fastened together by two screws, which allow for connecting ducts with a marginal difference in diameter. Sold in pairs. Specification Data Model ød Neoprene lining, inch Weight, lbs Item # FC 4 4 /3 4295 FC 5 5 /3 408 Dimensions / 3 " / 3 " D 2 / 3 " Dimensional information is in inches.

Laundries DID YOU KNOW.. That according to the National Fire Prevention Association (NFPA), the leading cause of home fires is from lint ignition in the dryer or dryer duct? A DEDPV or Dryer Booster from Fantech maintains an airflow that keeps lint suspended while exhausting it to the outside, thereby reducing the risk of fire. Dryer Exhaust Duct Power Ventilator DEDPV-705 That Spontaneous Combustion can occur in the dryer after the dryer stops due to high heat and no airflow? The DEDPV continues to operate for a short period of time after the dryer stops which cools the clothes and lessens the risk of spontaneous combustion. Dryers don't have an indicator to tell if there is a build up of lint in the duct? A safety feature of the DBF4XLT and DEDPV-705 is a visual indicator panel. This provides the user with a visual indication of correct operation or indication of a pressure increase due to a blocked duct. This advanced warning allows the user to take action to clean the dryer exhaust duct. That most dryers are limited to a duct run of 35'? Using a DEDPV or Dryer Exhaust Fans can increase the duct run up to 30 feet, as the fan relieves the pressure in the extended duct allowing the dryer to work efficiently.

Customer Support: Canada 800.565.3548 USA 800.747.762 support@.net Send Orders: Canada 877.747.86 USA 800.487.995 orders@.net Systemair Inc. September, 204 Art. 42038 Fantech reserves the right to modify, at any time and without notice, any or all of its products features, designs, components and specifications to maintain their technological leadership position. The application rendering presented in this brochure is for visual presentation purposes only. Please, contact a building professional for technical guidance.