Code Compliance. Selected Exit Check models are available to comply with one or more codes listed below. See Operation on page 3.

Similar documents
Exit Check Integrated Delayed Egress Locks

EXIT CHECK DELAYED EGRESS LOCKS

Exit Check Integrated Delayed Egress Locks

Exit Check Integrated Delayed Egress Locks

Delayed Egress Locks 38 SECURITY DOOR CONTROLS

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Delayed Egress System DORMA EMDE

Accessories. Desk Top Controls

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

White Papers: Delayed Egress Hardware

ACCESS & EGRESS LOCKING DEVICES SOLUTIONS. 1.2 Delayed Egress Locks. The lock behind the system. SDCSecurity.com

INSTALLATION INSTRUCTIONS EXIT CHECK DELAYED EGRESS EMLOCK 1511S / 1511T

Egress Devices for Code Compliant Access-Controlled Egress Doors

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

Optional cable and connectors SELECTRIC TM PRO

Multi-Mode Annunciators

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

Is the Key! Premium Grade Access Control Hardware

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

631RF Amp Power Supply

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

ACCESS & EGRESS REMOTE CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Security Professional Mobile Showroom. Product Training

PoE SOLUTIONS Power over Ethernet Capable Locking Hardware SOLUTIONS

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

Remote Chexit Module (RCM) System. General Information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

LR100 24V Latch Retraction / Dogging Kit

Pilfergard Door Alarms

ABLOY EFEND. New name for security

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

LR100 24V Latch Retraction / Dogging Kit

PRODUCT INTRODUCTION

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

SECTION DOOR HARDWARE

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

QUIET DUO LR100 SERIES

about HES is ISO 9001:2000 certified.

DE5300 Delayed Egress System. General Information

Alarmed Exit Hardware

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

2408/2900. Fire Guard

ALARMED EXIT HARDWARE

5900 SERIES Low Energy Power Operator

2409/2900. Fire Guard

Innovative Access & Egress Solutions. Security Door Controls Condensed Catalog. Copyright 2014, Security Door Controls. US Made

STANDARD FEATURES SPECIFICATIONS

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

EHT/EHTD. Electromechanical Closer-Holder Release Devices

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ED4000. Narrow Stile Pushpad Exit Devices

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

EPlex 5000 Series MONACO LOCK COMPANY, INC. TEL (800) FAX (800)

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

5900 Series X-in Low Energy Power Operator

Touchpad Exit Controller User Guide

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

HES and Securiton have united as ASSA ABLOY Electronic Security Hardware. Electronic Security

Electromagnetic Locks

APPENDIX F: LOCKSETS AND ACCESS CONTROL

MODEL B2 INSTALLATION MANUAL

EM 3000-EW AH INSTALLATION EARLY WARNING ELECTROMAGNETIC LOCK A. INTRODUCTION B. DELAY EGRESS FUNCTIONS

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

SARGENT Beacon TM. A Technical and Informational Newsletter From Dugmore & Duncan. Summer 2009 Vol. VIII - Issue II L

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

SECURITRON MODEL EXD EXIT DELAY SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS 1. DESCRIPTION

STANLEY PATIENT SAFETY LEVER (SPSL) STANLEY SECLUSION ROOM LOCK (SSRL) STANLEY EMERGENCY DOOR ALARM (SEDA)

Mechanical to Electrical Making the Jump

Single Door 39.5 Right Hand Push AL. Double Door (Twin) 75.5 Push AL Simultaneous 92 Push 11 + reveal BZ Independent Max reveal on a pull 2.

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

SECTION HARDWARE

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

RELEASE DEVICE CONTROLS

Series. Access Power Controllers. Installation Guide

ACDx10xE5000 Access Controlled Doors

PRICELIST Access. Value. Today.

Integrated Door Systems

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

5600 series. Low Energy Power Operator

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Series Electric Hinges/Pivots Hager Ives McKinney Stanley PBB Bommer Rixson ABH and more

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Transcription:

Exit Check Integrated Delayed Egress Locks Stop Commercial and Industrial Theft Stop Retail Shoplifting Restrict Concourse Pedestrians Restrict Wandering Patients VOICE Models 101S/D/T & 1511S/D/T Application When unauthorized egress is initiated, SDC Exit Check delays egress through the door for 15 seconds. Meanwhile, the person exiting must wait while personnel or security respond. The door unlocks after 15 seconds have elapsed, permitting egress. A signal from the fire/life safety system will release the lock for uninhibited egress in an emergency. Exit Check applications include: Theft protection for technology, merchandise and other valuables, such as museum artifacts. The control of pedestrian traffic in airports and other public facilities for security and public safety. Restricting the egress of patients for their own safety. Facility Applications Airports Convention Halls Wholesale Stores Long Term Care Drug Rehab Psychiatric Care Infant Nurseries Museums Art Galleries Warehouses Technology Facility Protected by one or more of the following U.S. Patents: 5,429,399 4,609,910 Code Compliance Selected Exit Check models are available to comply with one or more codes listed below. See Operation on page 3. IBC, International Building Code 1003.3.1.8.2 Delayed Egress Locks IFC, International Fire Code 1003.3.1.8.2 Delayed Egress Locks NFPA 101, Life Safety Code 7-2.1.6.1 Delayed Egress Lock NFPA 1, UFC - Uniform Fire Code 14.5.3.1 Delayed Egress Locks UBC, Uniform Building Code 1003.3.1.10 Special Egress Control Devices CBC, California Building Code 1003.3.1.10 Special Egress Control Devices SBC, Standard Building Code 1012.6 Special Locking Arrangements BOCA, National Building Code 1017.4.1.2 Special Locking Arrangements Chicago Building Code 10 (13-160-269) Electro-Magnetic Locking Devices. Certificate of approval available Wandering Patient Systems The SDC Exit Check is compatible with wandering patient systems, like those used for protection against infant abduction from hospital nurseries, and in long term care facilities for the protection of patients who may be endangered if they are able to leave their care facility without supervision. Access Control Access controls may be utilized for authorized egress or access. Access from the exterior of latching doors requires an additional means of mechanical lock release, such as a mechanical key or electric strike. Local Approval All installations must be approved by the Authority Having Jurisdiction (AHJ). ANSI/BHMA A156.24 American National Standard for Delayed Egress Locks MADE IN THE USA FWAX Special Locking Arrangements GWXT Auxiliary Locks SECURITY DOOR CONTROLS BHMA C E R T I F I E D California State Fire Marshal Listed www.sdcsecurity.com E-mail: service@sdcsecurity.com

Single Model 101S Annunciation For use with single doors equipped with surface vertical rod, concealed vertical rod, mortise and rim mount exit devices, mortise locksets and cylindrical locksets. 101S 1511S The Exit Check 101 series incorporates an alternating 85 db tone and verbal message with a digital countdown display and sign that provides clear and comprehensive instructions for persons without prior knowledge of door operation. This is especially significant for those who are blind and/or hearing impaired. 1511S / T & 1512D Annunciation Double Model For use with pairs of doors equipped with mortise, rim and concealed vertical rod exit device with concealed strikes and triggers, mortise locksets and cylindrical locksets. Activating either door unlocks both doors. 101D 1512D The Exit Check 1511S/T and 1512D incorporate an 85 db alarm with three distinct tones and a tri-color LED visual indicator to provide mode status. A sign per NFPA requirements is included. Standard Features Choice of Activation Trigger Built-in Door Movement sensor External trigger device input Exit Device Switch Latch Monitoring Strike Exit Sense Bar Fire Life Safety Release Input A signal from the fire alarm unlocks the door immediately Field select *manual or auto reset *UBC, California Compliant Slave Lock Output When utilizing Tandem and Double units, activating either door unlocks both doors in 15 seconds. Tandem Model For use with pairs of doors equipped with surface mounted vertical rod exit devices and concealed vertical rod exit devices with surface mounted triggers and strikes. Activating either door unlocks both doors. 101T 1511T Multiple Monitoring Outputs Door Secure / Unlocked Output Activation Alarm Output Door Position Status (optional) Magnetic Bond Status (optional) Access Control / REX Input Timed Bypass (Adj. 1,15,20,30 sec.) Built-in 3 Function Key Control Alarm Reset (NFPA function only) Sustained Bypass Timed Bypass (Adj. 1,15,20,30 sec.) Code Compliant Door Sign Compatible with Existing Locks and Exit Devices 2 BHMA Certified Holding Force 1650 lbs.

Activation Triggers How to Specify Specify Finish The Exit Check is equipped with a built-in activation trigger and a remote trigger device input. Built-In Activation Trigger The built-in activation trigger may only be used with doors equipped with a latch assembly (i.e. mechanical lockset or exit device). The mechanical latch mechanism must be locked on the exterior and unlocked on the interior. From the inside, retracting the door latch and applying pressure causes limited door movement. The built-in activation trigger senses the door movement and initiates delayed egress operation. Remote Activation Trigger Input Activation Trigger For Non-Latching Doors The remote trigger activation input must be used with doors without latch assemblies (i.e. latchless glass and herculite doors). Activation may be triggered by the SDC MSB550 Switch Bar or the SDC Sure Exit, request-to-exit push bar. A power transfer device is required. Pushing on the request-to exit push bar immediately activates the delayed egress operation. Activation Trigger For Latching Doors Where preferred, activation may be accomplished by a latch monitoring strike, or a switch installed in a standard latching exit device or lockset. A power transfer device is required for exit devices equipped with a trigger switch. See SDC datasheets for detailed information on SDC MS Series Latch Monitoring Strikes, Exit Device Switch Kits and Transfer Devices. 101S 101S ND K V Tone, Verbal and Digital Tone and LED Annunciation Annunciation 101S Single 1511S Single 101D Double 1512D Double 101T Tandem 1511T Tandem Specify Operation Mode 101S ND NFPA, UFC, SBC, IBC, IFC Compliant NA Adj. 15 or 30 Second Exit Delay Adj. 0, 1, 2, 3 sec. nuisance delay Manual reset, built-in or remote UBC, California Building Code NFPA, UFC, SBC, IBC, IFC Compliant ND 15 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote NFPA, UFC, SBC, IBC, IFC Compliant NH 30 Second Exit Delay (Fixed) Adj. 0, 1, 2 sec. nuisance delay Manual reset, built-in or remote BOCA Compliant BD 15 Second Exit Delay (Fixed) 1-second nuisance delay *Auto reset 30 seconds after door closure BH 30 Second Exit Delay (Fixed) 1-second nuisance delay *Auto reset 30 seconds after door closure *45 sec. when AHJ approved Chicago Building Code Compliant Contains no moving parts CD 15 Second Exit Delay (Fixed) 1-second nuisance delay Auto reset 30 seconds after door closure Specify Built-In Reset and Control 101S ND K Standard K Built-in Key Switch. Provides 1-45 second timed bypass, sustained bypass and alarm reset. Manual reset not available with BOCA and Chicago operation. Anodized Finishes V 628 Clear Aluminum (standard) X 313 Dark Bronze Y 335 Black Plated Finishes C 605 Bright Brass D 606 Dull Brass F 611 Bright Bronze G 612 Dull Bronze P 625 Bright Chrome Q 626 Dull Chrome Specify Options 101S ND K V DPS BA DPS Door Position Status The concealed DPS provides remote monitoring of the door open or closed status. This output is commonly used to alert personnel at a remote location if the door has actually been opened for egress after alarm activation. BA Magnetic Bond Alert Sensor The BA magnetic Bond Alert Sensor provides remote monitoring of proper and improper armature contact, due to reduced holding power, tampering, dirt or foreign material between the electromagnet and armature. ATS Anti - Tamper Switch The anti-tamper switch detects and provides remote monitoring of any attempt to remove the access cover. VI Custom Verbal Instruction A special verbal message may be specified for the 101S/D/T to meet specific application needs. Specify a specific message. Specify two alternating languages. Example Specifications Standard Specification Examples 101S NA K V 1511S NA K V Optional Specification Examples 101S BD K C 1511S CD L C Optional (in lieu of K) P Built-in Reset Push Switch Not available with BOCA and Chicago compliant models L Less Key or Push switch 3

Single, Double and Tandem Models are available to accommodate single and pairs of doors. See page 2 for proper application. S (Single) 101S Annunciation The Exit Check 101 series incorporates an alternating 85 db tone and verbal message with a digital countdown display and sign that provides clear and comprehensive instructions for persons without prior knowledge of door operation. This is especially significant for those who are blind and/or hearing impaired. NFPA 101 Models 101S ND K V Single 101D ND K V Double 101T ND K V Tandem BOCA Compliant Models 101S BD K V Single 101D BD K V Double 101T BD K V Tandem 101S 4 D (Double) T (Tandem) Code & Standard Compliance NFPA, UFC, UBC, SBC, IBC, IFC, and California Building Code ANSI/BHMA A156.24 American National Standard for Delayed Egress Locks Annunciation Alternating verbal exit instruction and alarm tone with digital countdown display. ND - Operation 1) When the door is closed, latched, and the lock is energized, 15 is displayed indicating the door is secure. 2) Applying less than 15 lbs of pressure and releasing the door latch activates the nuisance timer, intermittent alarm tone and the digital display count down. If the door is released before the nuisance time setting (0, 1, 2 sec.) has elapsed, the door stays locked, the alarm tone stops and the digital display resets to 15. 3) When activation exceeds the nuisance time (1, 2 sec.) or the nuisance timer is set at 0, an irreversible process begins that will unlock the door in 15 seconds. The digital display continues to countdown and the alarm tone and verbal instructions alternate. Tone...Security has been alerted. Exit in 10 seconds. Tone...Exit in 5 seconds. 4) The door unlocks when 15 seconds has elapsed and the digital display indicates 00. The alarm tone and verbal instructions continue to alternate. Tone...exit now. Tone...exit now. 5) The lock must be manually reset K - A built-in keyswitch provides alarm reset, sustained bypass and timed bypass. V - Clear anodized aluminum. City of Chicago Compliant Models 101S CD K V Single 101D CD K V Double 101T CD K V Tandem Activation by solid state electronics only. No moving parts. Annunciation Alternating verbal exit instructions and alarm tone with digital countdown display. BD / CD Operation 1) When the door is closed, latched, and the lock is energized, 15 is displayed indicating the door is secure. 2) Applying less than 15 lbs. of pressure and retracting the door latch sounds an activation warning tone. If the door is released in less than 1 second, the warning tone stops and the door stays locked. 3) When activation exceeds 1 second, an irreversible process begins that will unlock the door in 14 seconds. The digital display counts down and the alarm tone and verbal instructions alternate, alerting personnel. Tone...Security has been alerted. Exit in 10 seconds. Tone...Exit in 5 seconds. 4) The door unlocks when 15 seconds (1 + 14) has elapsed and the digital display indicates 00. The alarm tone and verbal instructions continue to alternate. Tone...exit now. Tone...exit now. 5) The door must be opened and then closed for 30 seconds before it automatically relocks and annunciation stops. Any reopening of the door before the end of the 30 second relocking cycle will restart the 30 second relocking cycle. K - Built-in key switch provides sustained and timed bypass. Reset is automatic. Manual reset not available. V - Clear anodized aluminum finish.

1511S/T & 1512D Annunciation The Exit Check 1511S/T and 1512D incorporate an 85 db alarm with three distinct tones and a tri-color LED visual indicator to provide mode status. A sign per NFPA requirements is included. NFPA 101 Models 1511S ND K V Single 1512D ND K V Double 1511T ND K V Tandem Code & Standard Compliance NFPA, UFC, UBC, SBC, IBC, IFC and California Building Code ANSI/BHMA A156.24 American National Standard for Delayed Egress Locks. Annunciation 3 distinct alarm tones and tri-color LED ND - Operation 1) When the door is closed, latched, and the lock is energized, the Green LED indicates the door is secure. 2) Applying less than 15 lbs of pressure and releasing the door latch activates the nuisance timer, intermittent alarm tone, and the LED becomes Amber. If the door is released before the nuisance time setting (0, 1, 2 seconds) has elapsed, the door stays locked, the alarm tone stops, and the LED changes back to Green. 3) When activation exceeds the nuisance time (1, 2 seconds) or the nuisance timer is set at 0, an irreversible process begins that will unlock the door in 15 seconds (30 seconds optional). The LED is amber and the alarm changes to an alternating tone. 4) The door unlocks when 15 seconds has elapsed, the LED changes to red and the alarm tone becomes continuous. 5) The lock must be manually reset. K - Built-in key switch provides alarm reset, sustained bypass and timed bypass (15-45 seconds). V - Clear anodized aluminum finish. BOCA Compliant Models 1511S BD K V Single 1512D BD K V Double 1511T BD K V Tandem City of Chicago Compliant Models 1511S CD K V Single 1512D CD K V Double 1511T CD K V Tandem Activation by solid state electronics only. No moving parts Annunciation 3 distinct alarm tones and tri-color LED BD / CD Operation 1) When the door is closed, latched, and the lock is energized, the Green LED indicates the door is secure. 2) Applying less than 15 pounds of pressure and retracting the door latch sounds an activation warning tone. If the door is released in less than 1 second, the warning tone stops and the door stays locked. 3) When activation exceeds 1 second, an irreversible process begins that will unlock the door in 14 seconds and annunciation continues, alerting personnel that egress has been initiated. 4) The door unlocks when 15 seconds (1 + 14) has elapsed and annunciation continues. 1511S 5) The door must be opened and then closed for 30 seconds before it automatically relocks and annunciation stops. Any reopening of the door before the end of the 30 second relocking cycle shall restart the 30 second relocking cycle. K - Built-in key switch provides sustained and timed bypass. Reset is automatic. Manual reset not available. V - Clear anodized aluminum finish. Emergency Release Selectable -Up Feature Field select method of lock power-up, automatic or manual, after power loss or emergency release: Auto -Up - When selected, regardless of the means of deactivation, relocking of the Exit Check occurs when power is restored and/or the fire life safety panel is reset. UBC, California Building Code/ OSHPD Compliant Reset Manual -Up - When selected, regardless of the means of deactivation, relocking of the Exit Check is by manual means only at the door. Only after power restoration and/or fire life safety panel reset, the door may be relocked by actuating the standard built-in key reset or optional wall mounted key switch, push switch or digital keypad located adjacent to the door. Optional Keyless Control 928 Entry Check 928 Entry Check Digital Keypad While the Exit Check is equipped with a standard built-in 4 function key switch for reset, manual power up, momentary bypass and sustained bypass functions, the SDC 928 wall mounted keypad provides the convenience of keyless operation for: Alarm Reset Manual -Up (UBC & California required) Momentary or Sustained Bypass 5

Stations Controls and Annunciators While the Exit Check is equipped with a standard built-in key switch for reset and bypass functions, wall mounted stations provide for convenient alarm reset, sustained bypass or timed bypass. Remote annunciators provide quick identification of activated openings, enabling security or care personnel to respond rapidly. Annunciators are equipped with an audible alarm and each station is identified by one tri-color LED that identifies specific mode status. Secure - Green, Activation - Amber x Audible Tone, Unlocked - Red x Audible Tone 928 702-6R 707-6R 928 Keypad (see page 5) 702-6R Alarm Reset Key Switch 707-6R Two Function Key Switch Alarm Reset and Sustained Bypass 101-1A The single station annunciator is equipped with a tri-color LED and audible alarm. 101-PAM Visual and audible annunciation, timed access, sustained bypass, and audible mute. 101-AK Visual and audible annunciation and a two function key switch for alarm reset and sustained bypass. 101-4AM Provides visual and audible annunciation with audible mute for two, three or four openings. Control / Annunciator Consoles Desk Top and Rack Mount SDC control and annunciator panels provide remote annunciation of multiple openings. Stations are specified in sets of four. Control switches are also available and capable of providing both sustained bypass and timed unlocking of individual doors. Consult the factory or refer to SDC control console datasheets for additional specifications. TCC Desk Top Stations: 4, 8 & 12 CAB Desk Top Cabinet CAB7: Accommodates 1 RCC CAB12: Accommodates 2 RCC Latch Strikes Trigger RCC Rack Mount Stations: 4-20 MS-16 For mortise latch, reversible Fits 4.875 Strike (provided by others) Gap & alignment adj. SPDT, 5 Amps @ 30VDC Surface Mount Transfer Loops PT-2U Stainless Steel PT-2B Black PT-3V Aluminum termination box Electric Transfer Hinges PTH-2Q Two 20 gauge wires; 3 Amps continuous, 8 Amps inrush 4.5 x 4.5 five knuckle standard weight Dull Chrome Sure Exit Request-to Exit Push Bar The Sure Exit is a non-latching, heavy duty, request-to-exit push bar that will activate the Exit Check when slight pressure is applied to the bar. Model PSB560V Aluminum Anodized PSB560X Dark Bronze Anodized PSB560Y Black Anodized Stainless steel and brass optional 36" is standard. For wider doors specify 42" or 48". May be field cut. Specifications Voltage Input: 12/24VDC Current Input: 20 ma at rest, 115 ma active Output: Two, SPDT Dry, 3 Amp @ 28VDC Operating Temperature: 0-150 F Exit Device Switch Kits Switch kits are field installed in the inactive hinge pad of rim mount exit devices, mortise exit devices, concealed vertical rod exit devices and surface vertical rod exit devices. Make & Model to be Fitted 510 Von Duprin 33, 99 510-2 Von Duprin 33, 99 DPDT 511 Von Duprin 55 512 Von Duprin 88 514 Dor-O-Matic 990, 1090, 1990, 2090 516 Sargent 9600, 9700, 9800, 9900 517 Adams Rite 8300, 8400, 8700, 8800 518 Precision Apex Series 519 Jackson 1095 519-2 Jackson 1095 DPDT 521 Corbin 4000 525 Monarch 18 & 19 527 Sargent 80 527-2 Sargent 80 DYDT 528 Sargent 20/60 531 Yale 7000 (Dogging mechanism required) 535 Kawneer Mid Panel Line Dor-O-Matic 1390 540 Arrow 5300/5400 Series 6

Component Considerations Emergency Release Modes Integrated Emergency Release Field Select Lock Auto Reset or Lock Manual Key Reset SDC Supply 926 702R-6U 707R-6U 708R-6U 101-1AK 12/24VDC 115VAC Fire Command Center Door Movement Trigger Latching Exit Device Rim Mount, Mortise, or Vertical Rod Optional Wall Mount Key Reset (Built-In Key Reset Standard) Exit Check 600 Series Supply Emergency Release *Field Select Supply Output Auto Reset or Manual Reset MS-16 101-1AU 101-4AM 101-PAM SDC Supply 115VAC Fire Command Center Latch Monitoring Strike Trigger For Mortise Exit Devices Remote Wall Mount Annuciator 12/24VDC Exit Check PT-2 PT-3 TCC RCC Dual Emergency Release 600 Series Supply Integrated Lock Emergency Release Field Select Lock Auto Reset or Lock Manual Key Reset Emergency Release *Field Select Supply Output Auto Reset or Manual Reset Sense Bar Trigger Non-Latching PSB560, MSB550 Remote Desktop Annuciator and Control Panel SDC Supply 115VAC Fire Command Center PT-2 PT-3 12/24VDC Local Smoke Detector Switch Kit PT-2 PT-3 or PTH-2 Exit Check Switch Kit Latching Exit Device with Built-in Switch Kit Trigger Latching Exit Device with Built-in Switch Kit Trigger *Emergency Release Manual Reset Not Available with 631RF Supply 7

www.sdcsecurity.com E-mail: service@sdcsecurity.com Mounting Detail Fig.1A Standard Mounting Fig. 1B With Filler Plate Refer to Filler Plates and Angle Bracket datasheet for proper filler plate specification. Fig. 1C With Angle Bracket Refer to Filler Plates and Angle Bracket datasheet for proper angle bracket specification. SW1 1 234 5678 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 DPS Door Position Status (optional) BAS Magnetic Bond Sensor (optional) 12 or 24VDC voltage sensing power input BLK GRN RED Slave lock activation trigger input (jumper when not used) Closed emergency release contact at fire panel. N/C RMB x L3 Local or remote timed access input. Remote annunciator with tri-color LED and audible tone. Local, wall mount reset key or push switch. Electrical Specifications Input Voltage: Dual Voltage 12 VDC ± 10% 24 VDC ± 10% Consumption: 101S 890 ma @12VDC 570 ma @ 24VDC 101T 1.56 Amp @ 12 VDC 920 ma @ 24 VDC 101D 1.56 Amp @12VDC 920 ma @ 24VDC 1511S 820 ma @ 12VDC 500 ma @ 24VDC 1511T 1.5 Amp @ 12VDC 850 ma @ 24VDC 1512D 1.5 Amp @ 12VDC 850 ma @ 24VDC Inputs Request to Exit: Normally open, dry Fire Alarm Release: Alarm panel closed dry contact. Opening of contact releases lock. Monitoring Outputs Alarm Output: SPDT Dry, 1 Amp @ 30VDC Lock Secure Unlocked Output: SPDT Dry, 1 Amp @ 30VDC DPS Door Position Status: (option) SPDT Dry, 250 ma @ 30VDC BAS Magnetic Bond Status: (option) SPDT Dry, 250 ma @ 30VDC ATS Anti Tamper Sensor: (option) SPDT Dry, 1 Amp @ 30VDC Mechanical Specifications Dimensions: Single: 11" L x 2.75" H x 2.625" D (279 L x 70 H x 67 D mm) Double: Tandem: 22" L x 2.75" H x 2.625" D (558 L x 70 H x 67 D mm) Master: 11" L x 2.75" H x 2.625" D (279 L x 70 H x 67 D) Slave: 11" L x 2.75" H x 1.5" D (279 L x 70 H x x 38 D mm) Armature: 7.375" L x 2.375" H x.5625" D (187 L x 60 H x 14 D mm) Sign: 13" L x 4.5" H (330 L x 114 H mm) 8 SECURITY DOOR CONTROLS P.O. Box 6219, Westlake Village, CA 91359-6219 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 (800) 413-8783 Fax: (805) 494-8861 2004 Security Door Controls Printed in the U.S.A. LIT-101S.1515S_0104 2.5 BA