NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Similar documents
Effective Biomass Moisture Control

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

ω = (1) Kirby S. Chapman Ph.D.

2. HEAT EXCHANGERS MESA

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Computer Modelling and Simulation of a Smart Water Heater

MODEL AND SIMULATION OF DEEP-BED CLOVE DRYING: EFFECT OF FERMENTED TREATMENT

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

compressed air or left to consume air even when the associated production machine has been turned off.

SOME PROBLEMS IN DEVELOPING MECHANICAL GRAIN DRYER AND RESEARCH IMPROVEMENT

Mathematical Simulation of Longan Fruit Drying

Project Report 6 REFRIGERATION ENERGY USE IN THE FOOD CHAIN PROJECT REFERENCE (TBA) CONTRACT REFERENCE (TBA)

2 A e ( I ( ω t k r)

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

State-of-the-art Developments to Save Energy in Coating Drying

Drying principles and general considerations

Recent BRANZFIRE enhancements and validation

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

INDUSTRIAL DEHUMIDIFICATION DRYING OF SOFTWOODS

Fluidised-Bed Paddy Drying

Understanding total measurement uncertainty in power meters and detectors

Effect of the Use Pattern on Performance of Heat Pump Water Heater

THE A.A.B. COMPANY 615 McCallie Avenue Chattanooga, TN

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Numerical study of heat pipe application in heat recovery systems

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

Experimental Investigation of Tube Configuration for a Surface Condenser

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

(Refer Slide Time: 00:00:40 min)

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

MODELING OF THE SINGLE COIL, TWIN FAN AIR-CONDITIONING SYSTEM IN ENERGYPLUS

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Reducing energy use, airstream heat gain, and condensate production

Dedicated Closed Circuit Hydrostatic Fan Drive Control

Conventional Electric Space Heating Systems

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Reducing energy use, airstream heat gain, and condensate production

Experience in relocating a fluidized-bed steam drier

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Performance Study of Triple Concentric Pipe Heat Exchanger

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

PAPER MACHINE ENERGY FINGER- PRINT. Carl-Fredrik Lindberg 1, Kevin Starr 2, Robert Horton 2, Naveen Bhuthani 3

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

System Design & Diagnostic Analysis of Group 2 Systems

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Shortcut Model for Predicting Refrigeration Cycle Performance

International Journal of Food and Biosystem Engineering. May 2015 Vol. 1, No. 1. Optimisation of industrial Food Drying Operation. Henry T.

Adding More Fan Power Can Be a Good Thing

Steam humidification: Reducing energy use, airstream heat gain, and condensate production

The Digital Scroll Dryer

14 Drying. I Basic relations and definitions. Oldřich Holeček, Martin Kohout

Brine Generation Study

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

Mango Sheet Drying by the Solar Dryer Combine with Electric Coil

State-Of-The-Art Developments to Save Energy in Coating Drying. Bob Bates, P.Eng Metso Paper

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Figure 1. Structure Used For the Simulations.

A GRAPI-IIC MEUCCI or ESTIMATING VENEER!DRYING RATES

1.1. SCOPE OF THE WORK:

An experimental study of the impact of tunnel suppression on tunnel ventilation

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

J. LINES, Graham Corp., Batavia, New York

by Richard W. Bukowski Center for Fire Research Program for Fire Detection and Control Systems National Bureau of Standards Washington,

Heat Transfer in Evacuated Tubular Solar Collectors

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

Small Scale Pilot Plant Thermal Dryer for Sewage Sludge Dewatering System A Preliminary Study

Carwin COMPRESSOR SELECTION PROGRAM

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Transcription:

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY USING A NEW CONCEPT IN MOISTURE SENSING AND CONTROL BY DRYING TECHNOLOGY, INC

A New CD Warp Control System For the Corrugating Industry Introduction: Brief history of Drying Technology, Inc Drying Technology, Inc., (DTI) was introduced to the corrugated board CD warp problem in the late 1980 s as a result of a request for a proposal and quote for a warp control system. Later, the research department of a large paper manufacturing company requested a similar proposal. We complied with each by proposing a system that included use of our basic, patented Delta T sensing technology 1 that requires two temperature sensors and a mathematical model derived from first principles to sense and control linerboard moisture content (MC). The first company soon dropped their project, and the paper company informed us that they would develop their own system; however, they never did. Later, we modified our basic moisture sensing technology to provide a more practical and effective method for sensing linerboard (liner) MC exiting a preheater. This new liner MC sensing method was incorporated into our earlier warp control system concepts which now offer an excellent chance for solving the industry s CD warp control problem. All that remains is to test it on a corrugator. The Warp Control Problem: It is well known that linerboard (liner) expands when wet and shrinks as it dries. Further, when two liners are joined in a corrugated board, the difference in the top and bottom liner MCs must be below about 1% to prevent warp. Therefore, a control system that is capable of maintaining this no warp MC difference under conditions of differing corrugator speed, liner basis weights, and incoming MCs, should be successful in virtually eliminating CD warp in corrugated board. Controlling moistures for the purpose of reducing or eliminating warp is not a new concept; however, in practice its effectiveness has been limited by the lack of a reliable and rugged moisture sensor. Some warp control systems were designed with conventional IR moisture sensors traveling back and forth across the liner width to scan the liner MC. However, the harsh environment of a corrugator, the relatively high cost of conventional IR sensors, equipment for moving the IR sensor across the web, and the unreliability of conventional IR moisture sensors appears to have forced the use of liner surface temperature as substitute for liner MC. It will be shown below that prediction of MC using temperature is quite poor and significantly reduces the effectiveness of control systems using this approach. 2

Non-Conventional Moisture Sensing: Work commenced on the Delta T moisture/dryer model conceptualization in 1975 followed by completion of the derivation of the model (equation 1) in 1979. A moisture sensing and control system was successfully applied to eight veneer dryers during the period 1982 to 1984 using this non-conventional method for sensing and controlling MC using two temperature sensors and a mathematical model derived from first principles. A paper describing its derivation was presented in November 27 28 at the North American Wood Symposium, MS. State, MS., followed by two patent 2 applications filed in 1984 and 1985. Patents were granted in 1987 and 1988. The model for continuous drying is: MC = K 1 ( T) p K 2 /S q (1) The product moisture content (MC) is related to the temperature drop ( T) of hot air after contact with the wet product; and (S) is the production rate or dryer speed; Ks are constants, and p & q are exponents. The use of proprietary methods developed over the past 23 years eliminates the need to determine exponents and constants. It should be noted that raw delta T renders the model inoperative. Proprietary methods must be applied to make it work. The Delta T model initially was used to predict product MC exiting dryers, ovens, kilns, and the like with a high degree of accuracy and reliability. It does not require costly and time-consuming calibration as do conventional moisture sensors. The controlled variable, ( T), the difference in two temperatures, is easily determined which enables MC sensing in very harsh environments. The Delta T been validated by over 350 successful installations on such dryer-types as flash, spray, fluidized-bed, rotary, and conveyor during the drying of a variety of products. 3 Modification of the Delta T: Later, it was found that the Delta T principle not only could predict the MC from a drying operation, but also from webs such as textiles and liner that are cooling after exiting a preheater. Two successive surface temperature sensors are placed immediately after the preheater such as in figure (1) for the purpose of sensing the top or bottom liner MC. The basic Delta T model remained the same with the exception that the ( T) term is determined in a slightly different manner. If the evaporation rate from the liner is a function of the MC and the cooling rate (T 1 -T 2 ) is a function of the evaporation rate, if follows that MC is proportional to the cooling rate. 3

Figure (1) Location of Temperature Sensors For MC Measurement of Liner Figure (2) shows the relationship between the delta t measurement on the cooling curve and the corresponding liner moistures. The liner temperature (red) is shown as it enters the preheater from the left and heats up. Upon exiting the preheater, the liner temperature follows a cooling curve. Temperatures T 1 and T 2 are used to predict moisture (M 2 ) shown on the (blue) moisture curve.. Figure (2) Liner Temperature & MC To and From a Preheater 4

Development of Simulation Model Data: A simulation program was written using the information from this article. The simulation uses a finite time-element approach for solving heat and mass transfer balances from the time the paper comes in contact with the preheater to a distance after the preheater. The paper temperature and moisture content were tracked in small increments over this distance. The results from the simulation were compared to the data and charts found in the literature to verify the correctness of the calculations. Such operating parameters as speed, preheater wrap, basis weight, and incoming paper MC were varied over a wide range of operating conditions. The next step was to include the Delta T moisture sensor technology in the simulation. Data was recorded for each basis weight by running a matrix of operating conditions at various speeds, preheater wrap percentage, and incoming moisture. Approximately 200 different conditions were run and recorded based on the following, Speed Preheater Wrap 150 m/s to 225 m/s in 25 m/s increments 30% to 90% in 10% increments Incoming Liner MC 6.0% to 9.0% in 0.5% increments The data was analyzed and the Delta T principle applied to determine the correlation between the delta t value and moisture of the liner at a distance beyond the preheater. Excellent correlation exists for all four basis weights used. These results are proof that the Delta T principal could be applied to the cooling of the paper after the preheater to determine the moisture of the paper. It was also noted that the paper temperature alone did not correlate well with paper moisture as shown in figure (3) below. MC Vs Liner Temperature Shows Poor Correlation: Although numerous attempts have been made over the years to use temperature to predict liner MC, correlation between MC and temperature is quite poor as seen in figure (3). Therefore, temperature of the liner should not be used as a surrogate for liner MC in a warp control system, which is in agreement with comments found in the literature 5. 5

Figure (3) MC Vs Temperature For 42 lb linerboard MC Vs Delta T Value shows excellent Correlation: As mentioned above, the evaporation rate from the liner is proportional to the MC, and the cooling rate is proportional to the evaporation rate. Therefore, delta T is proportional to MC. A plot of MC vs delta T for 42 lb liner at the same simulation conditions as used in figure (3) shows delta T to be an excellent predictor of MC as seen in figure (4) below. Figure (4) MC Vs Delta T For 42 lb linerboard 6

Figure (5) shows excellent correlation between MC and delta T for four basis weights; therefore, liner MC should be easily predicted and controlled based on delta T. This presents proof that use of the Delta T method of MC sensing and control can be used to improved CD warp control in the corrugating industry. Figure (5) MC Vs Delta T At Various Basis Weights Development of the Delta T Warp Control System: Recognizing that warp might be eliminated or significantly reduced by maintaining a difference between the top and bottom liner MCs, simulations were run at various differences in top and bottom liner MCs that were assumed to be at no warp conditions. Both temperature and the delta T method of providing relationships at no warp conditions were compared. The results are shown in figures (6) and (7) below. Figure (6), a plot using the simulation data, shows poor correlation between bottom and top temperature for the no warp conditions. These results reinforce our earlier conclusion that the use of temperature as a surrogate for MC would not provide an adequate basis for a warp control system. 7

Figure (6), Bottom Vs Top Liner Temperatures Figure (7), a plot using the same simulation data, shows that the use of the delta T method for sensing MC produces a no warp relationship with excellent correlation. Figure (7), Bottom Vs Top Delta T Values At No Warp Condition 8

A warp control system can now be designed that maintains the no warp delta T relationship. Similar relationships are generated for various differences in MCs at the no warp condition. This no warp relationship holds even for board made from liners at different basis weights. Warp Control Algorithm Development: The next step in the process was to determine the relationship between the top and bottom delta t values at the conditions of no warp. The application of the Delta T had to be made without knowing the actual moisture of the liners, since liner moisture would be difficult to obtain on a production line. Assumptions were made concerning the moisture relationship between the top and bottom liners that would result in no warp. Four assumptions for no warp differences between top and bottom moisture were tested. These were no warp with: (1) The bottom liner moisture is 0.5% greater than top moisture. (2). The bottom liner moisture is 0.7% greater than top moisture. (3) The bottom liner moisture is 1.0% greater than top moisture. (4) A varying difference based on the bottom moisture. Data was gathered by running the simulation with varying incoming liner moistures and wrap arm positions. The wrap arms were adjusted to satisfy the assumption of a specific difference between the top and bottom liners and then the data was recorded. These data points would represent the no warp conditions. The no warp data was analyzed and the Delta T principal was applied. There was an excellent relationship between the top and bottom delta t values during the no warp conditions. An excellent relationship was found for all four no warp conditions (figure (7)). The initial test was made with the same liner on top and bottom. Additional test were made with two different liners and the results were the same. The control algorithms would be set up to maintain the relationship between the delta t values by adjusting the wrap arms. The control algorithms were programmed into the simulation to test the automatic control of the wrap arms to maintain no warp conditions. The error in the relationship between the top and bottom delta t values was used to initiate a control response. The basic scheme was to control the wrap arms in a way to maintain an equal distance from 50% warp. This would help to eliminate a preheater warp from reaching a minimum or maximum value too quickly. Another constraint is the minimum temperature required for gluing. Moisturizers could also be used to adjust moisture if needed. 9

Figure (8) Simulation Program Screen Display Conclusions and Recommendations: It is commonly known that if the difference in the top and bottom liner MCs could be easily measured and controlled, a warp control system for virtually eliminating warp in the finished board might be a possibility. Based on work described above, we propose a warp control system based on a new, simple, nonconventional MC sensor for use in controlling the moisture of each liner. This new CD warp control method can be supplied in the following listed packages: 1. If allowed, Integrate the Delta T warp system into an existing wet end control system. 2. A stand-alone Delta T warp control system. References: 1. Robinson, John, Improve Moisture Control, Chemical Engineering Progress, vol. 88, no. 12, pp. 28-33, 2, US Patents 4, 701, 857 & 7,777,604 3. Robinson, John & Douglas, Roger, Improve Moisture Control for Profit, The Process Engineer, April 2005, 3 pgs. 4. Taylor, Bruce, The Interaction of Paper Moisture and Temperature and its effect on Corrugated Board Quality, Corrugating International, Vol. 1, No. 3, pp. 39-50. 5. ibid. Rev. 12.5.2010 10