MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES

Similar documents
SOLAR SYSTEM. We follow the sun.

Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007

CONDANSATE TRANSFER PUMP

FLEXIBLE CORRUGATED TUBE

STEAM EQUIPMENT 4

Cater Hoses. Manufactured to BS669 PT2: /2 & 3/4 Braided Cater Hose with Lanyard - Quick Release

LIQUID ELIMINATORS/ FLOAT TYPE LIQUID DRAINERS

All our certificates could be downloaded from our web site:

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Flexible Gas Tubing. Semi-Rigid Corrugated Stainless Steel Tube System PRODUCT GUIDE.

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

STEAM TRAPS

Settlement Agreement. Schedule 1: Covered Products

Problem-solvers The Radiator Solution Range

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Dynaflex Hot melt hoses

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

10.85 VicFlex Sprinkler Fittings

Systems for central heating

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

GASTEC QA. Approval Requirements 69-1

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

General System Layout Sketch

VAILLANT SPARE PART CATALOGUE

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs


ADDITIONAL PRODUCTS 65

HERZ Differential Pressure Control Valve 4002

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

NEPTUNE 1. Model: NEPTUNE Part List English

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

The Safest Connections...

Cold water HD 9/18-4 ST

Mounting and Operating Instructions EB 2231 EN

WASHER & DRYER REPAIR

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

HERZ Regulating valve 4002

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F

C 9000 Polymer Quick-Acting Safety Coupler Range

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

INSTRUCTION & MAINTENANCE MANUAL

HD 7/11-4 Classic. Durable and robust. Improved cleaning performance. Especially easy to maintain. Excellent mobility

HP310-C EXTRACTOR 120V

INTELLI-VAC 14 INTELLI-VAC 18

Spare parts list ( ) Spare parts list Priza

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

TERMINATOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

Brazed heat exchanger XB

Safety Quik (formerly Cimfast) Name: CF Model Numbers: CF 50, CF 75, CF100

Hydrotherapy Jets (Remote Water Quality System)

Stocking Dealer Catalog

FOOD - PHARMACEUTICAL Industrial Vacuum Accessories

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

BDM Direct Vent systems are for use with direct vent gas fired appliances.

ELECTRIC ASH CAN Model: CVACASH500 Part No:

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Series 1140 and 1141 Temperature Regulators

T-29. Heating Systems HOT WATER 2017 PRODUCT CATALOG CENTRAL HEATING SYSTEM WITH SOLID FUEL. Depth (mm) Width (mm) Height (mm)

L J BATH - KITCHEN & MEDI LAB 1 24"

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

R7521SS COLORS/FINISHES. Stainless Steel 21 15/16" 1 3/16" 8 5/64" 1 25/32" 2 1/8" 23 5/8" Max. 1 3/8" G1/2" Female

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

LINDOFLAMM thermal engineering.

Installation instructions

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Safety vacuum drying oven for flammable solvents

Flow Measurement SITRANS F C

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Half Inch Round LED Rope Light

MAXUM 5 5 Gallon Box Extractor

R7520SS COLORS/FINISHES. Stainless Steel 16 9/16" 7 15/16"

Quick closing oil drain valve QDV

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Flat Line Spray Systems Kits

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

SuperKlean Washdown Products

Installation Instructions

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

SYSTEM MANUAL Description

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

The sealless FLUX F 424

Transcription:

A MEMBER OF EURO-QUALIFLEX MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES MIG-GAS MIG-SU Scan this QR Code www.ayvaz.com

MIG-GAS (NATURAL GAS CONNECTIONS) Application Areas Natural gas applications Kitchen appliances Combi boilers and water heaters Cookers and grills Design With their closed pitch corrugated structure, Mig-gas hoses provide a highly flexible and extensible connection for all kitchen appliances. It can be manufactured with or without polyolefin based cover. Mig-flex hoses are exposed to special heat treatment. Heat Treatment eliminates the stresses caused by the tubing, mechanic forming and fitting welding processes and increases the flexibility as well as the corrosion resistance of hoses while reducing the spring rate accordingly. Heat treatment helps hose to save the form and the shape given. Advantages of Ayvaz s MIG-GAS Natural Gas Connection Hoses: Connection: Extensible structure provides the best connection features for non-classified distances. Offers great connection features for all indoor natural gas applications as a household gas hose to cookers, gas stoves and fireplaces, gas-operated grills, barbecues, combi boilers and heaters. Can be installed in tightest bending radius with no reduction in cross sectional area. Safety: Mig-gas hoses are produced with the highest degree of safety and guaranty the highest level of health and safety for the users. (acc. UNI 11353 and UNE 60713/1) Non-flammable, polyolefin shrink protects the hose against the corrosive effects of the chemicals such as cleaning materials, fire and mechanical damages. Service Life: Production process (heat treatment) homogenizes the hose material and provides a relieved structure from occurred stresses that increases the service life of the hose accordingly. Ayvaz Ball Valve (For natural gas) Mig-Gas Economic Installation: Reduces the cost and time for installation with its highly flexible and extensible structure. Provides the best connection features possible, at various installation distances and can be manufactured in all lengths from 90mm up to 00mm.

MIG-GAS (NATURAL GAS CONNECTIONS) PRODUCT FEATURES Hose Type : Closed pitch corrugated extensible metal hose Hose Material : AISI 316L Fittings Types : Female-Male/Female-Female Fittings Materials : Nut in AISI 304/303 EN ISO 228/1 Nipple in AISI 304/303 EN ISO 7/1 Cover : Polyolefin Cover in Yellow or coverless Gasket : NBR / Aluminium NOMINAL DIMENSIONS DN Connection Length (mm) x x x x 90x140 130x2 2x4 300x600 500x1000 750x1500 1000x00 Special lengths for specific purposes may be available on request. CONNECTIONS No Type of Connection Material DN inch 1 Male Connection EN ISO 7/1 2 Swivel Female Connection EN ISO 228/1 Inner Part and Nut

MIG-SU (WATER APPLICATIONS) Application Areas Sanitary Radiator connections Combi boilers, water heater connections Washing machine connections Tank and storage connections Expansion tank connections Decorative piping system Design Mig-Su water connection hose is a highly flexible structured, time and cost saving hose assembly which is highly resistant against pressure and temperature. Ayvaz s Mig-Su hose prevents the problems caused by rigid connections. Because of the hose s flexible design, corrugations are able to make expansion and compress movements and this provides a non-calcified structure. Heat Treatment eliminates the stresses caused by the tubing, mechanic forming and fitting welding processes and increases the flexibility as well as the corrosion resistance of hoses while reducing the spring rate accordingly. Heat treatment helps hose to save the form and the shape given. Safety: Mig-su hoses are produced with the highest degree of safety and guaranty the highest level of health and safety for the users. (acc. UNI 79) Non-flammable, polyolefin shrink protects the hose against the corrosive effects of the chemicals such as cleaning materials, fire and mechanical damages. Service Life: Production process (heat treatment) homogenizes the hose material and provides a relieved structure from occurred stresses that increases the service life of the hose accordingly. Advantages of Ayvaz s MIG-Su Water Connection Hoses: Connection: Extensible structure provides the best connection features for non-classified distances. Offers great connection features for all indoor water connections as a flexible water connection hose to sanitary applications, tank and storage connections, combi boilers and heaters. Can be installed in tightest bending radius with no reduction in cross sectional area. Economic Installation: Reduces the cost and time for installation with its highly flexible and firm structure. Provides the best connection features possible at long connections and can be manufactured in all lengths from 90mm up to 00mm. Ayvaz Ball Valve (For natural gas) Mig-Gas Combi Connection Set Ayvaz Strainer Ayvaz Ball Valve (For water)

MIG-SU (WATER APPLICATIONS) PRODUCT FEATURES Hose Type : Closed pitch corrugated extensible metal hose Hose Material : AISI 316L Fittings Types : Female-Female, Female-Male Fittings Materials : Nipple in stainless steel EN ISO 7/1 Nut in Brass EN ISO 228/1 Internal parts in stainless steel Cover : Polyolefin Cover in White or Coverless Norm : UNI 79 NOMINAL DIMENSIONS DN Connection Length (mm) x x x x 90x140 130x2 2x4 300x600 500x1000 750x1500 1000x00 Special lengths for specific purposes may be available on request. CONNECTIONS No Type of Connection Material DN inch 1 Male Connection EN ISO 7/1 2 Swivel Female Connection EN ISO 228/1 Inner Part Nut Nickel Coated Brass

COMBI CONNECTION SET Application Areas Complete hose set includes Mig-Gas and Mig-Su hoses For combi boilers, gas and water connections HOSE DIMENSIONS DN QTY CONNECTION TYPE 2 1/2 x1/2 MF Mig-Su 2 3/4 x3/4 MF Mig-Su 1 3/4 x3/4 MF Mig-Gas LENGTH (mm) 2x4 NSTALLATION The hose line should be installed without exposed to twisting. No torsion stress must occur neither during the assembly, nor the operating. Otherwise, the service life of the hose reduces. Both ends of the hose and the movement must be on the same plate. Only one end of the hose must be tightened first to be assured that no twisting on the hose assembly occurs. Afterwards, the hose must complete its movement for couple time while it is in neutral position under no torsions. Finally the other end of the hose must be connected.

Some Examples For Proper Hose Assemblies The hose must be installed in an arc of 180. The nominal hose length and installation distance are calculated in a relation with bending radius. Connection arcs or elbows made by rigid pipe pieces may prevent the bending stress and torsions. Non-permissible deflections caused by the rigid pipepieces behind the hose connections must be avoided. Minimum bending radius should be detected. Connection arcs or elbows made by rigid pipe pieces may prevent the sinuous bending stress and extreme torsions. Hose bend and the direction of the movement must be on the plate, this way the torsion can be prevented to reach dangerous levels. The direction of the hose movement and hose axis should be on the same plate. This prevents the dangerous torsion stress. Hose must be hanging freely and it should be installed as it does not contact anywhere even at the maximum expansion situation. The hose line should be protected from the deflections and sharp strains caused by the support points behind the connection fittings of the both ends of the hose. In such cases, using a bobbin or guiding chain may be useful. HEAD OFFICE - FACTORY Atatürk Sanayi Bölgesi Hadımköy Mahallesi Mustafa İnan Caddesi No: 44 Arnavutköy - İSTANBUL Tel: +90 2 771 01 45 (pbx) Fax: +90 2 771 47 27 info@ayvaz.com www.ayvaz.com