ALTOR16BV ALARM PANEL

Similar documents
Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

Two-Channel Gas Controller

Door Release Power Supply

Operation and Maintenance Manual

Technical Manual. Level Alarm Unit CARLA & WIDS

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Specification/ Data Sheet

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Conventional Fire Alarm System 2014 V1.2

FEC403EN Installation Manual

Installation, Operating and Maintenance Manual

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

ESP TECHNOLOGIES LIMITED

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

20 Light Remote Annunciator

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Oxygen (O2) Single-Point Gas Detection System

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Danfoss gas detection units

PolyGard 2-channel Gas Controller MGC-03

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

3M Oldham MX 43 Controller

Multi-Gas-Controller MGC2

OPERATION AND INSTALLATION MANUAL

Dräger REGARD -1 Control System

FEC400 Series. Installation Manual

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Series. Access Power Controllers. Installation Guide

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

CONTROL DEVICE SLIDETRONIC HD

AIS750 Series Alarm Annunciator

VSN PLUS VSN 4 PLUS ; VSN 8 PLUS ; VSN 12 PLUS

Detection, Protection, Innovation

FX FIRE DETECTION SYSTEM

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

SINGLE MONITORED INPUT UNIT BN-303

DIGITAL ALARM UNIT Model ALU-AP

MCR9705 Smoke and Heat Exhaust Control Unit

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Beacon 410A Gas Monitor Operator s Manual

SCAN200E USER S MANUAL

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

SELECTRONIC TATTLETALE Remote Alarm Annunciators ST Series

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

Conventional Fire Detection

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Electronic Emergency Telegraph. TG-1 and TG-1A

Dräger REGARD -1 Control System

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

ALARM DEVICES FOR MAN OVER BOARD AND RESCUE ACTIONS (DAHMAS)

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

SIGA-CC1 Single Input Signal Module Installation Sheet

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

PURGE/PRESSURIZATION SYSTEM

Interface and EOL Modules 8

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

M2500 Engine Controller Installation Manual

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Conventional Leaflets

Alarm system For oil-water separator

30.45 Electric Release PDRP-2001

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

CONVENTIONAL FIRE ALARM CONTROL PANEL

SIL725 Safety Annunciator

OilMatic Pro / 230 V AC

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Danfoss gas detection units

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

Selectronic Tattletale Remote Alarm Annunciators

Commercial and Light Industrial Fire Alarm Control Panel

Beacon 800 Gas Monitor Operator s Manual

Accessible Toilet Alarm

Transcription:

ALTOR16BV ALARM PANEL The ALTOR16BV is a 16-channel configurable alarm panel. Each alarm line is monitored. Its quick and easy installation makes it a complete, Bureau Veritas approved product. PG07 PRODUCT DATA SHEET Outputs Horn output (up to 0.5Amp/24VDC) 4 x NO/NC grouped outputs 1 RS485 output (VDR) 1 RS232 output Application DESCRIPTION Provides indicator light display and audible signal functions for all the types of faults that may be encountered on a vessel. 16 configurable alarm channels. Functional characteristics Display By wide viewing angle Led. Functions Immediate or delayed (3, 6 or 10 seconds) detection when the fault occurs by turning on the corresponding red Led NO/NC selection by switch in each channel Test pushbutton for Indicator light and buzzer Fault acknowledgement pushbutton Alarm resetting pushbutton Configuration By switch on the circuit board Mechanical features Dimensions (LxWxH) and Weight: ALTOR16BV : 144 x 144 x 147 mm 1.0Kg Ingress Protection: o IP44 Electrical characteristics Main power supply: 24VDC (0.3 A max) Supply protection: Current overload by a resettable fuse. Supply polarity reversal by diode Standards and Approvals Bureau Veritas certificate No 16553/A0 BV FP ALTOR16BV GB REV 1

Electrical connection COMMUN 19 VOIE 1 20 VOIE 2 21 VOIE 3 22 VOIE 4 23 VOIE 5 24 VOIE 6 25 VOIE 7 26 VOIE 8 27 COMMUN 28 VOIE 9 29 VOIE 10 30 VOIE 11 31 VOIE 12 32 VOIE 13 33 VOIE 14 34 VOIE 15 35 VOIE 16 36 B 1 +24VDC ALIMENTATION 0VDC ALIMENTATION 2 3 4 5 6 RS485 A+ RS485 B- COMMUN EN 0VDC 7 BP ACQUIT EXTERIEUR DU SIGNAL SONORE 8 9 SORTIE BUZZER EXTERIEUR 10 RELAIS GROUPE 1 RG1 11 12 13 RELAIS GROUPE 2 14 RG2 15 RELAIS GROUPE 3 16 RG3 17 RELAIS GROUPE 4 18 RG4 A Mechanical drawing: VUE ARRIERE VUE DE COTE VUE DE FACE 138.00 136.00 reprise de blindage des cables 144.00 138.00 découpe d'encastrement: 138x138mm. 136.00 111.00 137.00 147.00 144.00 Associated products SIRENE24VDC107DBBP FLASHROUGE+SIRENE FP ALTOR16BV GB REV 1

ALTOR8 ALARM PANEL Flooding detection and miscellaneous alarms safety equipment PG 07 PRODUCT DATA SHEET DISPLAY BOX ACQUISITION AND TERMINAL BOX To avoid false alarms, a time delay can be programmed on all channels. To ensure maximum system reliability, the product continuously monitors the state of the electrical cable connecting the box to the sensor. This informs the user, through an audible and indicator light alarm, of any short-circuit or open-circuit preventing the monitoring of the sensor status. An audible signal output is designed to transfer the audible signals generated by the ALTOR8: it is enabled at the same time as the internal buzzer An indicator light signal output is designed to transfer the audible signals generated by the ALTOR8 to an external device (flashing light or other): it is enabled at the same time as the internal buzzer. French regulation Application DESCRIPTION The ALTOR8 is a product designed to monitor the state of 8 dry contact sensors with MARINELEC line monitoring, and generate an audible and light alarm when the sensor changes state. It is powered from a nominal voltage source of 24VDC Note: for vessels less than 12 meters long, a single power supply is required. The installation must be performed with "flame retarding" type approved cables. Field of application: "Fishing vessels of less than 12 meters long" "Fishing vessels not less than 12 meters long and less than 24 meters long". These provisions are applicable to all vessels built after 1 st January 2007. Vessels existing before 1 st January 2007 must comply with the provisions of this article before 1 st June 2009. (Official Journal of 13 June 2006). FP ALTOR8 GB REV 1 OJ of 4/08/2009 - fishing vessel less than 12 meters long. IV. - In article 227-2.09 "Prevention of water ingress (decked and semi-decked vessels), the text of

paragraph 1.2 is replaced by the following: "1.2. Decked or semi-decked vessels existing before 1st January 2007, including vessels build before 1st September 1990, must achieve compliance with the provisions of this article: before 1st June 2010 for vessels built between 1st September 1990 and 1st January 2007; before 1st June 2011 for vessels built before 1st September 1990." FRENCH MERCHANT NAVY approved (certificate No. 19930/A0 MMF) Complying with the amended rules concerning water level alarms on vessels less than 24 meters long. CCS 790/REG.06 report of 5 April 2006. DIVISION 227 fishing vessels less than 12 meters long. Article 227-2.09 DIVISION 226 fishing vessels not less than 12 meters long and less than 24 meters long. Article 226-3.13-1 DIVISION 361 Water ingress alarm and detection devices Articles 361.01 to 361.05 Functional characteristics Capacity Display 8 dry contact sensors Line monitoring Indicator lights Functions Presence of one or two power supplies. Loss of the main supply. Loss of the backup power supply. Line monitoring. Loss of communication between the display sreen and the terminal box Active sensors and/or if line faults identified. Stop audible signal and indicator light, buzzer and output test External outputs 1 external horn output 1 external flash output 1 RS485 output for transfer to another item of equipment Channels Configurable as NO or NC Time delays from 0 to 10 seconds for each group of 2 channels Mechanical features Display box dimensions (LxWxH): 96 x 96 x 52 mm Weight: 0.5 kg Terminal box dimensions (LxWxH): 200 x 130 x 80 mm Weight: Mounting: 2 kg Flush-fitted or surface Electrical characteristics Consumption: 0.3 A in standby mode, 1 A max in alarm mode (with horn and flash light) Main and backup supply: 18 to 32 VDC Connection: Removable connector with a max capacity of 1mm² PG9 cable gland Protection: Protected against polarity reversals and through resettable fuses Standards and Approvals FRENCH MERCHANT NAVY approved (certificate No. 19930/A0 MMF) Complying with the amended rules concerning water level alarms on vessels less than 24 meters long. CCS 790/REG.06 report of 5 April 2006. DIVISION 227 fishing vessels less than 12 meters long. Article 227-2.09 DIVISION 226 fishing vessels not less than 12 meters long and less than 24 meters long. Article 226-3.13-1 DIVISION 361 Water ingress alarm and detection devices Articles 361.01 to 361.05 FP ALTOR8 GB REV 1

Associated products SIRENE24VDC107DBBP FLASHROUGE24VDC DVES01 BV1 MSL FLASHROUGE+SIRENEM DVES01SBV1 FP ALTOR8 GB REV 1

ALTOR4 ALARM PANEL SAFETY EQUIPEMENT : WATER INGRESS DETECTION MISCELLANEOUS ALARMS PG07 PRODUCT DATA SHEET Stop audible signal and indicator light, buzzer and output test. External outputs: 1 external horn output. Configuration Application DESCRIPTION The ALTOR4 is a product designed to monitor the state of four dry contact sensors compatible with the MARINELEC line monitoring, and generate an audio and light alarm when the sensor changes state. To avoid false alarms, a time delay can be programmed in all channels. To ensure maximum system reliability, the product continuously monitors the state of the electrical cable connecting the box to the sensor. This informs the user, through an audible and indicator light alarm, of any short-circuit or open-circuit preventing the monitoring of the sensor status. An audible signal output is designed to transfer the audible signals generated by the ALTOR4: it is enabled at the same time as the internal buzzer. The installation must be performed with approved shielded cables. Functional characteristics Capacity: 4 dry contact sensors, Line monitoring incorporated. Display: indicator lights Functions: general-purpose power supply source 9 to 32 VDC, Line fault monitored, Water ingress alarm, Active sensors and/or if line fault identified, Channels: configurable as NO or NC, Time delays from 0 to 10 seconds for each group of 2. Power supply: 9 to 32 VDC Protection: against polarity thanks to resettable fuses Max. consumption: 0.3A in standby mode, 0.5A in alarm mode (horn and flash light) Breaking capacity: 0.5 A/24 VDC of outputs Electrical connection: removable connector, Max capacity 1mm². Cable gland PG09. Cables used: BV approved 1-pair cables, (Detector connection) with shielding (at least 0.75 mm²) Box dimensions: 200x130x80 mm (LxWxH) Weight: 2 kg Protection factor: IP44 Storage conditions: -30 C to 70 C Operating conditions: -10 C to 55 C Maximum humidity: 95% RH Not condensable at 40 C FP ALTOR4 GB REV 1

Mechanical characteristics Dimensions (LxlxH) : Mounting: surface FLASHROUGE+SIRENEM DVES01SBV1 Electrical characteristics FRENCH MERCHANT NAVY approved (certificate number: 22084/A0 MMF) Complying with the amended rules concerning water level alarms on vessels less than 12 meters long. CCS 790/REG.06 report of 5 April 2006. DIVISION 227 fishing vessels less than 12 meters long. Article 227-2.09 DIVISION 361 Water ingress alarm and detection devices Articles 361.01 to 361.05 Field of application: "Fishing vessels of less than 12 meters long." These provisions are applicable to all vessels built after 1 st January 2007. Vessels existing before 1 st January 2007 must comply with the provisions of this article before 1 st June 2009. (Official Journal of 13 June 2006). DVES01 BV1 MSL OJ of 4/08/2009 - fishing vessel less than 12 meters long. V. - In article 227-2.09 "Prevention of water ingress (decked and semi-decked vessels), the text of paragraph 1.2 is replaced by the following: «1.2. Decked or semi-decked vessels existing before 1st January 2007, including vessels build before 1st September 1990, must achieve compliance with the provisions of this article: before 1st June 2010 for vessels built between 1 st September 1990 and 1st January 2007; before 1st June 2011 for vessels built before 1st September 1990.» MARINELEC associated products SIRENE24VDC107DBBP FLASHROUGE24VDC