LS Series Solvent Recovery Systems

Similar documents
LS-JRE OPERATION & INSTRUCTION MANUAL

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Hazardous Waste Self Audit

Water treatment made easy! Evaporators for the treatment of industrial wastewater.

PARTS CLEANING AND DEGREASING

LS Series Little Still Instruction Manual

Vacuum and Compressor Systems for the Chemical Process Industry

A Complete Package That Includes:

ECONOMY MODELS. URS500, High Performance URS500EP2

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

Flammable and Combustible Liquids: Storage and Handling

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Flammable and Combustible Liquids Checklist

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

Temptek Auxiliary Equipment

This series is utilized for waste streams which are not prone to hardening in the presence of liquid solvent, and provides ease of residue removal.

Solvent Saver Recycler Systems. Operation and Maintenance Manual Gallon Recycler

BE-55C Instruction Manual

Design Benefits and Advantages:

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

RTS SERIES RIVEER TREATMENT SYSTEMS. The Solution is Clear with Riveer SM. Engineered Wash Water Recovery Systems

Flammable and Combustible Liquids

Industrial Applications

Solutex Vacuum Evaporator Systems

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

INSTRUCTION MANUAL SOLVENT RECYCLER MODEL PART # SR 20

Concrete Applications

Solvent Saver Recycler & Vacuum Assist Systems Installation, Instruction & Maintenance Manual

Section K CHLORINATION EQUIPMENT

Heater Inspection Guidelines

Working safely with flammable liquids

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

CENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs)

Airless Vacuum Cleaning Systems

OPERATING INSTRUCTIONS

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

BLAST-IT-ALL BUMPER BLASTER

EXAIR's compressed air operated Reversible Drum Vac System attaches

Tepid Water Delivery System

Sioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers

GIRTON CABINET WASHER MODEL 794A

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

VAC-U-DRY VACUUM DEHYDRATOR

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

Models Goldfisch Fat Extraction Apparatus

LQ AQ SQ. Air-cooled and water-cooled portable chillers

High Capacity Instantaneous Steam Fired Water Heater

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

ASME Packaged Electric Water Heater

ZERO Economy Blast Cabinets

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications

Solvent Saver Systems Operation and Maintenance Manual. 55-Gallon Recycler

Airblast Tech Tips Grit Recycling Systems - common questions and answers

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Owner s Manual Phoenix Aquadry TX 200

INSTRUCTION MANUAL SOLVENT SAVER RECYCLER. STANDARD CAPACITY (SC) 3 GAL MODELS (1100 or 9711) & HIGH CAPACITY (HC) 6 GAL MODELS (25000 or 9725)

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

WINDFERN ROAD HOUSTON, TEXAS D-500 Dry Polymer Make Up System

Increasing Energy Efficiency in the Web Coating Process

The Experts in Vacuum Solutions

Electron Microscopy Sciences

BETACURE 100 CO-REACTANT

Economy Models. Cleans 1 Spray Gun and Pot using Wash Timer 9 Swirl Action Jets Tank Size 12.5 x 12 x 13.5 (WDH )

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

GEYSER Heat Pump Water Heater

Vacuum Booster for Distillation Process

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

KOCH Curtain Coaters

Quest PowerHeat HFC 100 Pro

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

D-1000 Dry Polymer Make Up System WINDFERN ROAD HOUSTON, TEXAS

NQ Series Portable Chillers

VENTLESS DOOR-TYPE DISHWASHER

Owners Manual MINI-CLASSIC II. Pure Water. Water Distiller

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

OWNER S MANUAL (English)

USER MANUAL. COMBO605/606 and COMBO655/656 UNI-RAM CORPORATION ONTARIO CANADA COMBO605. Revision

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Capture Waste Heat with Ultra-High Efficiency

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Explosion-proof Duct Heaters

Premium Laboratory Equipment HBX EVAPORATION GUIDE

Indirect-Fired Water Heaters

SIOUX HYBRID WATER HEATER

FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

Transcription:

Why Recycle? LS Series Solvent Recovery Systems Profitability is measured in many ways. Looking toward the future of your business is as important as having an environment in which to do business. Finish Thompson saw this many years ago when we produced our first solvent recovery system, reducing environmental risks while increasing profitability. Reduce hazardous waste... Solvents are a leading source of hazardous waste and major contributors to air and water pollution. Federal regulations, such as the Resource Conservation and Recovery Act, and state and local regulations mandate treatment and disposal of hazardous solvent waste. LS Series on-site solvent recyclers reduce the accumulation of this hazardous waste and the associated environmental and liability risks. and increase profit! In addition to reducing environmental risks, the LS Series has a high return on investment. Recycling used solvents recoups the expense of new solvents and eliminates costly outside transportation and disposal services. Don t let someone haul your money away! Clean solvent for as low as 10-15 cents/gallon. Benefits LS Series recyclers... Return a 99 + % pure, reusable solvent Are used in applications such as: Commonly recycle: Reduce solvent-based waste Wash-up paint lines and guns MEK (methyl ethyl ketone) Require minimal labor Inks from printing machines Acetone Provide a fast ROI Inks from decorating machines Lacquer thinner (solvent blend) Are safe and reliable Degreasing of machined parts Mineral spirits Clean up easily with non-stick lining and Wash-up fiberglass from molds Naphtha Stilbags Have a proven track record And many, many more... Toluene Provide consistent quality Are made in the U.S.A. Xylene Esters (primarily ethyl and butyl acetate) MIBK (methyl isobutyl ketone) Alcohols Replacement solvents and many, many more... www.finishthompson.com

The Process Sequence of operation: 1. The operator inserts a standard Stilbag into the boiling chamber, which is lined with a non-stick coating. Solvent is poured or pumped into the chamber. (A Stilpan may be used instead of the Stilbag.) 2. The boiling chamber lid is secured and power to the unit is activated. Heat is transferred from the encapsulated heater through the conductive walls and bottom of the chamber and into the solvent. 3. As the solvent boils, vapors form and pass through the vapor tube into a water-cooled condenser. LSJRE boiling chamber filled with solvent. 4. The vapors are cooled and return to a liquid state. This clean, clear liquid gravity flows into a receiving drum (5-gallon pail on LSJRE). The contaminating substances remain behind in the boiling chamber. 5. A visual check confirms that the distillate flow has ended and the unit is shut off for cooling. After cooling, the residue contained in the boiling chamber is removed via Stilbag or Stilpan and disposed of according to local regulations. Results Residue is removed from the boiling chamber at process completion and disposed of according to local regulations. www.finishthompson.com LS Series solvent recycling equipment can provide many years of safe, simple and efficient daily operation with little operator attendance. When properly installed, LS equipment satisfies the most stringent safety standards for on-site solvent recycling. LS equipment returns a nearly pure, completely reusable product, provides a high recovery yield, and allows the user to control the distillation schedule. Utilizing thermal distillation, LS Series solvent recyclers return waste industrial solvents to a 99+% pure, reusable condition. Finish Thompson s solvent recyclers are batch type in 5, 15 or 55 gallon capacities. All units distill solvents, are explosion proof, and are vacuum capable. With vacuum assistance, recyclers can process solvents with boiling points up to 500 o F. LS Series equipment requires minimal operator involvement. Once set up and started, the units can operate virtually unattended until the process is complete. A full line of accessories is offered to enable process automation from fill to finish. A patented heater design eliminates the need for heat transfer fluids and utilizes electricity more efficiently. The Little Cooler provides a convenient cooling water source for electrically heated LS Series solvent distillation systems, eliminating the need for a tap water source. Self-contained and weatherproof, the Little Cooler is designed for use with solvents with boiling points above 150 F (65.5 C). Depending upon solvent volume, an LS Recycler can pay for itself in a matter of months. Contact FTI Sales for the payback formula.

Safety & Design Features Installation Guidelines: Recycler must be located in an area with only explosion proof electrical devices present and with electrically interlocked floor ventilation. All containers must be grounded. LS55E with JetVac The LS55E processes up to twenty 55-gallon drums of contaminated solvent a week at an average rate of 55 gallons per 6-8 hours. FTI s exclusive vacuum attachment allows recovery of solvents with boiling points up to 500 o F. The JetVac option is available for all models. JetVac Operation - FTI s exclusive JetVac technology is the most reliable way to create high levels of vacuum with virtually no maintenance and very low operating costs. Vacuum levels as high as -28 hg can be reached enabling high boiling point solvents to be safely recovered. How does the JetVac work? A stainless steel reservoir is initially filled with a small amount of clean solvent during the set up process. A small stainless steel vertical pump is immersed in the clean solvent and is powered by an explosion-proof electric motor. Clean solvent is drawn into the pump and forced through the vacuum generator tube. Air from the distillation tank and piping is removed, lowering the pressure in the system, and allowing the solvent in the distillation tank to boil at a lower temperature. When the solvent begins to boil, clean, distilled solvent flows into the JetVac reservoir and is gravity fed into a collection drum. The installation must be approved by an accredited inspector prior to operation. A detailed manual and safety instructions accompany each recycler. Vapor Stilbag Toggle Clamp Pressure Relief Valve Hinged Lid Vapor Outlet Condenser Water Flow Switch/Interlock Water Cooled Condenser Indicator Light Stilbag Retainer Ring Outer Shell Non-stick Boiling Chamber Ceramic Fiber Insulation Contaminated Solvent Heating Element Lid Lift Pedal www.finishthompson.com Quick Cool Coil Encapsulated Heater Stilbag Rack Stilbag Vent Tube Electrical Connection Box Quick Cool Water Connectors

Heater Element Patented encapsulated heating element in chamber bottom ensures even distribution of heat through out the chamber. NO inefficient hot oil immersion heating is needed. Residue Removal Residue is contained inside a disposable Stilbag liner for quick removal from the boiling chamber. An optional Stilpan is available. The distillation chamber has a nonstick coating for cleaning ease. Quick Cooling Coil Enables fast cool-down of distillation chamber between operations. Push/Pull Light Indicator A lighted indicator displays on-off mode. Solid State Design - Insures reliability and accuracy. Construction - Finish Thompson Solvent Recyclers are built to Class 1, Division 1, Group D (NEMA 7) standards of the National Electrical Code. Explosion-proof components carry independent testing laboratory approval. All LS units are CSA approved (except LSJRE JetVac). Insulation - Lid and distillation tank are fully insulated with ceramic fiber for heat retention and efficient distillation. Vacuum All LS Series units can accept an FTI JetVac attachment to allow processing solvents with boiling points up to 500 o F. Flow Switch/Interlock The distillation unit operates ONLY when sufficient volume of cooling water is present. Interruption of water terminates power to heater. Dual Thermostat Two thermostat controls are provided so the unit temperature does not exceed the recommendation for heater temperature in a Class I, Division I, Group D environment. Adjustable Temperature Controller Allows setting variable temperatures. Ground Terminal Block Terminal #1 - Receiving Drum Terminal #2 - Filling Container Terminal #3 - Earth Ground Removable Cover Vacuum Gauge Hinged Cover JetVac Pump Motor On-Off Switch All Finish Thompson manufacturing processes strictly adhere to ISO 9001 guidelines to ensure consistent quality and delivery commitments. Each system is thoroughly tested prior to shipment. Vacuum Discharge Hose Distillate Sight Glass Cooling Coils Stainless Steel Reservoir Tank FTI s heater design eliminates the need for heat transfer fluids and utilizes electricity more efficiently resulting in a lower cost per recovered gallon of solvent. Discharge Hose JetVac Pump Vacuum Actuator Multiple coats of industrial grade, nonstick coating are applied to the interior of the distillation tank to ensure easy cleaning. When combined with our Stilbag liners, they are the easiest to clean systems on the market! All LS units are CSA approved.* LS Series distillation systems carry a full 3-year warranty on the heater. Finish Thompson solvent recyclers are used by thousands of customers worldwide FTI has a toll-free technical support hot line to answer any questions for the life of the equipment. * LSJRE JetVacs are not CSA approved.

Models LSJRE Features: - Designed for low solvent volume - Non-stick coating on boiling chamber for cleaning ease - 5-gallon capacity - Requires little space - Clean distillate gravity feeds to a 5-gallon pail - Variable temperature controller - One-switch operation - Easy to install - Little maintenance LSJRE Specifications: 3-5 gals/shift 4 amps 1/8 1/4 gpm Length 29 Depth 24 Height 19 165 lbs. JRE JetVac Features: - Retrofittable to all LSJR units - Allows atmospheric or vacuum distillation - Adjustable to 28 mercury vacuum - Easy to read vacuum gauge - Fully grounded LSJRE JetVac - Vacuum Attachment 3 5 gals/shift 200 500 o F 240V/1PH/60Hz, 1.7 amps Cooling Water 1/4-1/2 gallon Length 12 Depth 20 Height 17 80 lbs. Little Cooler* - a self-contained water/ glycol recirculation system designed to provide a closed loop water supply to the condenser. For use with LSJRE, LS15/55E and LS15II/55IIE models: - Corrosion-resistant water/glycol reservoir - High capacity recirculation pump with motor - Integral radiator with fan and motor - Weatherproof enclosure *Little Cooler is not explosion-proof and must be installed outside the explosion-proof area. Ambient air temperature cannot exceed 100 o F. Little Cooler Specifications: Utility Requirements 240V/1PH/60 Hz, 5.5 amps Dimensions Length 31 Depth 22 Height 22 186 lbs. LS15E Features: - Rugged construction - 15-gallon capacity - Non-stick coating on boiling chamber for cleaning ease - Condensed solvent gravity feeds to a 15-gallon drum - Skid mounted - Easy to install - Simple to operate - Minimal maintenance *Used for 1/2-1 hour to cool distillation tank at cycle completion (optional use). LS15E Specifications: Quick Cool Water* 15 gals/shift 7.5 amps 1/2 gpm 1 3 gpm Length 51 Depth 27 Height 42 425 lbs.

LS15IIE Features: - Automated cycle completion - Automatic water valves control water supply to condenser - Vapor temperature gauge monitors solvent vapor temperatures - Lid view glass to monitor distillation process - Heat on indicator light - Electrical surge protection and low voltage DC controls - Non-stick coating on boiling chamber for cleaning ease LS15IIE Specifications: Quick Cool Water* 15 gals/shift 7.5 amps 1/2 gpm 1 3 gpm Length 51 Depth 27 Height 42 565 lbs. LS55E Features: - Rugged construction - Non-stick coating for cleaning ease - Large 55-gallon capacity boiling chamber - Swing-hinged lid and lid lift foot pedal - Skid mounted - Easy to install - Simple to operate - Minimal maintenance LS55E Specifications: Quick Cool Water* 55 gals/shift 30 amps 1 1/2 gpm 2-5 gpm Length 56 Depth 34 Height 65 961 lbs. LS55IIE Features: - Swing-hinged lid and lid lift foot pedal - Automated cycle completion - Automatic water valves control water supply to condenser - Vapor temperature gauge monitors solvent vapor temperatures - Lid view glass to observe process - Heat on indicator light - Electrical surge protection and low voltage DC controls - Non-stick coating on boiling chamber for cleaning ease LS55IIE Specifications: 55 gals/shift 30 amps 1 1/2 gpm Quick Cool Water* 2-5 gpm Length 56 Depth 34 Height 65 1020 lbs. LS15E/LS55E JetVac Features: - Rugged construction - Allows vacuum or atmospheric distillation - JetVac pump is adjustable to 28 mercury vacuum - Condensed solvent is gravity-fed from the vacuum unit to a 15 or 55 gallon drum - Easy to read vacuum gauge - Fully grounded - Retrofits to existing installations *Used for 1/2-1 hour to cool distillation tank at cycle completion (optional use). LS JetVac - Vacuum Attachments LS15E & 15IIE JV LS55E & 55IIEJV 15 gal/shift 55 gal/shift 200 500 o F 240V/1PH/60Hz; 3 amps Cooling Water 1/4-1/2 gallon Length 22 22 Depth 25 25 Height 48 48 325 lbs. 335 lbs.

SOLVENT RECOVERY APPLICATION QUESTIONNAIRE Company: Contact: Mail Address: Street Address (shipping): Phone: Email: Fax: Web site: 1. What type of solvent or solvent blend? If a blend (mixed) what are the ratios? 2. What is the solvent boiling point? o F o C (circle one) Greater than 300 o F requires vacuum attachment. 3. What is the contaminant? 4. What volume is the waste stream? Gallons/week to be reclaimed What is the present method of disposal? 5. What process generates the waste solvent? 6. What will be the end use of reclaimed solvent? 7. Is the solvent and/or contaminant extremely toxic? If yes, please comment. 8. Is there water mixed in with the material? How much? 9. What is an acceptable recovery rate? 10. Is there any purity required? Key for high priced or specialized solvents! 11. Installation Requirements: Voltage/Phase Access to H 2 O hook up Explosion proof NEC Class 1, Division 1, Group D NFPA Guidelines: #77 Static, #91 Exhaust, #30 Flammable Liquid Indoor / outdoor installation Cut out form and fax or mail to Finish Thompson Inc. FT07-973C -1-19-11