Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Similar documents
Zenith Chill Tap. Affix Model Number Label Here 89520NZ. Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Domestic Chill Tap

Zip Domestic ChillTap

Zip Chilltap Extra. Affix Model Number Label Here UK. Installation and Operating Instructions

Affix Model Number Label Here

Zenith ChillTap Sparkling

Zip Chilled Water Systems

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zip HydroTap Miniboil

Zip Chillmaster Floor Mounted Chiller

Miniboil Boiling Only

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

HydroTap Taps Installation

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Installation Instructions Zip HydroTap G4 CS Residential Affix Model Number Label Here

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Installation Instructions. Filtered Boiling and Boiling Ambient drinking water for commercial kitchens and tea rooms.

Zip HydroTap G4 Celsius

Installation & Operating Instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

ZIP HydroTap G4 Celsius User Guide

Zip HydroTap. B & BA Residential. Affix Model Number Label Here Installation Instructions

Installation Instructions Zip HydroTap G4 BCS Residential Affix Model Number Label Here

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip Autoboil Installation and Operating Instructions

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Affix Model Number Label Here 89944

Zenith HydroTap. Filtered Chilled drinking water for residential kitchens and tea rooms. Affix Model Number Label Here NZ

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Installation guide Sahara & Sahara Plus

Zenith HydroTap. CS Residential. Filtered Boiling, Chilled and Sparkling drinking water for Residential kitchens and tea rooms.

Zip Autoboil. Installation and Operating Instructions

OP40R 40cm Remote Control Pedestal Fan

SCHWAN INSTALLATION GUIDE

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Install Guide Billi Quadra & Quadra Plus (Gooseneck)

OT600E Tower Fan with Remote Control

Installation guide Billi Quadra & Quadra Plus XL, XT, XR tap options

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zip ChillTap Sparkling (CS) Models

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Pear Kitchen Sink Tap

User guide Billi B-4000 Tap options XL, XT, XR

OT750RI 360 O Tower Fan with Remote Control

User guide Billi Eco Sparkling Tap option XL

ZIP HydroTap. User Manual

User guide Billi Sahara & Sahara Plus Tap options XL, XT, XR

Target Monobloc Kitchen Mixer Chrome

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

Work-Shed Vac 1100 Watt

SCHWAN INSTALLATION GUIDE

Installation guide Billi Quadra Sparkling & Quadra Sparkling Plus Tap option XL

Model pictured: ST6001

User guide Billi Eco Tap options XL, XT, XR

Installation & Operating Instructions

Blueberry Kitchen Sink Tap

Cinnamon Kitchen Sink Tap

HW3 Handwash Installation and Operating Instructions

Zip HydroTap G4 Filtered Boiling, Chilled and Sparkling drinking water for commercial kitchens and tea rooms.

INSTALLATION MANUAL CT-200

Beeline Monobloc Kitchen Mixer Tap

Monza Easyfit Kitchen Sink Mixer

ZIP HydroTap G4 User Manual Affix model number label here UK

Installation and Operating Instructions

DRINKING WATERCOOLER MANUAL. Website:

Brita. Water Filter & Chiller. Instruction Booklet WF6000. Please read these instructions carefully and retain for future reference.

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

OPAL MINI. Instruction Manual

The Arden Oscillating Floor Fan

Autofill Wall Mount Boilers

User guide Billi B-6000 Tap options XL, XT, XR

Do not leave the appliance unattended whilst connected to the mains supply. Always use this appliance on a solid, level, non-flammable surface.

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

Installation and Operating Instructions. ZIP UK Domestic - DOMBC2 - Filtered boiling and chilled drinking water for kitchens.

AE2400 Elite Series Ceramic Tower. Instruction Manual

Installation & Operating Instructions

Installation & Operating Guide

User Guide Reverse Osmosis Undersink Water Filter Systems RO SERIES

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Service Manual Zip HydroTap Miniboil Boiling and ambient drinking water for kitchens and the home.

User guide Billi Quadra & Quadra Plus Tap options XL, XT, XR

B900/ BME900/ SKOPE Gen2: Two Door Chiller

Oil Panel Heater Instructions for Use

ZIP HydroTap G4 User Guide Affix model number label here UK

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

ZIP HydroTap G4 User Guide Affix model number label here UK

Manual / Handbuch Spare parts list / Ersatzteilliste

Zip Product Guide The latest from the world leader in instant boiling and chilled filtered water

Unvented Electric Water Heater 10/15 litre Undersink

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Instant Hot Water Dispenser Owner s Manual

Hot-1 Hot Water Dispenser

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45

Installation & Operating Guide

Instructions for the Use and Care and Installation of ORU52X ORU70X. Undermount Rangehoods CONTENTS

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A

Transcription:

Installation and Operating Instructions Zip Chilltap Extra Filtered Ambient and Chilled drinking water Affix Model Number Label Here 89520 Chilltap Extra - Installation & Operating Instructions - 89520 - April 2012 v1.01 Page 1 of 8

# Read Section These Heading Warnings First Please read all installation requirements, installation procedures and precautions before installing any Zip Chill Tap. Never attempt to install any Zip Chill Tap without reading all of the applicable instructions. All electrical connections must comply with current wiring rules. This appliance is not designed for use by young children or infirm people without supervision. Young children should be prevented from having access to ensure they are not able to use or play with the chiller. This appliance must be earthed. If the power supply cord is damaged it must be replaced by a Zip Service Provider or a qualified electrician. The Power cord and general power outlet must be in a safe and accessible position after installation. Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply. This unit is designed for indoor use and must not be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet. This unit is fitted with a chilled water expansion relief valve. It is normal operation to experience a small discharge from the carafe spout as the water will expand when the unit is chilling down. This is a protection device to prevent internal damage. Precautions The plumbing installation must be done in accordance with local Water Authority regulations and these Installation Instructions. As the installer, it is your responsibility to supply (if necessary) and install all valves as required by local regulations and relevant standards. Page 2 of 8 Chilltap Extra - Installation & Operating Instructions - 89520 - April 2012 v1.01

# Installation Section Heading requirements Power supply 220-240V AC 50Hz for connection via a 10amp G.P.O. Operating temperatures 5º C - 35º C. Water pressure 70 kpa - 700 kpa (0.07 MPa -0.7 MPa) NOTE: For best results we recommend a minimum static pressure of 200 kpa (0.2 MPa) # Installation Instructions Installing the Chiller Sit the chiller unit into the cupboard as close to the proposed outlet tap position as is possible, to minimise the length of tubing exposed between the chiller unit and the outlet tap. Allow at least 50 mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must remain accessible for servicing purposes. Installing the Tap Position and install the carafe filler at the back of the sink or on the Font, where there is a minimum 52 mm wide flat area within the draining area of the sink. Make sure the selected position allows the carafe filler spout to overhang the sink bowl. Use a 35 mm sheet metal punch to create a neat hole without burrs. Remove the large nut with the brass and rubber washers from the base of the carafe filler, leaving the rubber-sealing ring (o-ring) in place. Fit the carafe filler and seal to the sink, oriented so both the operating levers are easily accessible. Slide first, the rubber washer and then the brass washer, followed by the nut, over the plastic tubes from under the sink, and tighten the nut to secure the carafe filler firmly into place. John Guest connections Chilltap Extra - Installation & Operating Instructions - 89520 - April 2012 v1.01 Page 3 of 8

# Installation Instructions continued Connecting: Inlet and outlet connections for Expansion Valve Ferrule NOTE: You must separately supply and install an isolating valve in the supply line before the connection to the product. If the pressure exceeds 700kPa, you must also supply and install a 350kPa pressure-limiting valve. Minimum supply pressure must be 70kPa. For best results we recommend a minimum static pressure of 200 kpa (0.2 MPa). Ambient Connection (with chiller inlet branch line): Nut & Olive With 1/4 white tubing, Connect the outlet of the Pressure Reduction valve to the inlet of the filter. From the outlet of the filter, connect the 1/4 white tubing from the vented carafe filler, via the Tee piece supplied. The branch line from this Tee piece must connect to the JG fitting marked INLET on the top right rear of the chiller. Cut excess off to ensure a neat job. Make sure all connections to John Guest fittings are pushed in past the O ring to full depth, at least 15-16mm. Clear Blue Chiller connection (with expansion control valve): Similarly, use the Blue tube, to connect via a Tee piece, to the JG fitting marked OUTLET on the top left rear of the chiller unit. Insulate the 1/4 BLUE tube with the loose length of the pipe insulation, cut both pieces to correct length. Now connect the branch line from the (Blue tube) Tee piece, with a length of 1/4 Clear tube to the inlet of the relief valve. Locate the 1/4 Clear (vent) tube from the carafe filler and connect this to the outlet of the relief valve. NOTE: The inlet and outlet connections on the brass relief valve require the use of a small internal brass ferrule. This ferrule is used to stop the LLDPE tube from collapsing when the brass nut and olive are tightened. White Flow Clear Pressure reduction valve Isolation Valve NOT SUPPLIED Expansion control valve Filter Under Bench Chiller Page 4 of 8 Chilltap Extra - Installation & Operating Instructions - 89520 - April 2012 v1.01

# Installation Section Heading Instructions continued The Tap connection is now complete. Take care, when bending rigid plastic tubing, to prevent it from kinking or crushing around a bend. As it is plastic tubing containing water under mains pressure, be careful not to nick, scratch or damage it during installation. Cut the tube squarely with a sharp knife or tube cutter. Shake out and remove any swarf and debris. Ensure there is adequate ventilation available through the cupboard. If there is inadequate ventilation, and the cupboard temperature rises to above 40 C, the chiller may become damaged and malfunction which will void the product warranty. The air temperature should be no more than 35 C. There must be a minimum 168cm2 of cupboard cross-flow ventilation. Suitable holes or vents will need to be cut into the cupboard and door. For safe operation, thoroughly flush the water through after non-use periods longer than 12 hours. Filter cartridges (if fitted) should be replaced at least every 6-12 months, or sooner if you notice: A. A persistent reduction in water pressure from the product, or; B. An unpleasant taste or odour in the water. Not changing the cartridges when required may cause the water to become biologically unsafe. Commissioning Clip the tubing in the cupboard. After the appliance is installed and connected, turn ON the water supply. Check all connections for leaks. Repair any leaks found. The filter, chiller and tubing will be full of air until purged. Press the operating lever on the appliance outlet tap for a minimum of five minutes until all of the air has been purged from the system. Plug the 3-pin power cord into a standard power point. Do NOT turn ON until after the unit is purged. Wipe clean and dry the area. Dispose of packaging wisely. End of life disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details Chilltap Extra - Installation & Operating Instructions - 89520 - April 2012 v1.01 Page 5 of 8

# Operating Procedures ROTATE Operation: The lever on the right is used for Chilled filtered water and the other, on the left, is used for Ambient filtered water. Chilled water is obtained by rotating the lever on the right, to a horizontal position. The water is chilled by a refrigeration unit fitted within the cabinet stand, under the basin. With the carafe filler, you can obtain chilled water within the rated capacity, for as long as you leave the lever in the open (horizontal) position. When finished, return the lever to the OFF (upright) position. Ambient water is obtained in the same way as the chilled water, by rotating the lever on the left hand side of the carafe. Cleaning Never use strong, corrosive or abrasive cleaning materials on the Zip Chill Tap. Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water. The louvres on the sides of the chiller unit need to be kept free of dust and lint to permit free flow of air through the vents. They should be checked regularly, at least monthly, and dusted or vacuumed. Filter Replacement The Zip Chill Tap Under Counter Chiller may have a separate filtration system connected to the incoming water supply line, and which may be located within the same cupboard as the chiller unit. For safe operation, the filter cartridge should be replaced every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water. WARNING Not changing filtration cartridges when required, may cause the water to become biologically unsafe. Make an entry in your diary to check the water quality of the Chill Tap at least six months after installation and after every subsequent filter change. Use only a Zip Filter to match that used with this Chill Tap (if fitted). Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip. Replacement instructions come with the filter cartridges. Before attempting to disconnect or remove the filter cartridge from the housing, isolate (turn off) the water supply prior to the filter system, and then relieve the system pressure by operating the chilled water outlet tap until the water ceases to flow. Service There are no user serviceable parts but there are dangerous voltages present within the unit. All service work must only be carried out by a suitably qualified and experienced service person. Before calling for service, check that both the water and electricity supplies are turned ON and OK. Call an electrician, a plumber, or Zip for a free call in Australia on 1800-638-633, for assistance, service, spare parts, or enquiries. Page 6 of 8 Chilltap Extra - Installation & Operating Instructions - 89520 - April 2012 v1.01

# Section Heading Notes Chilltap Extra - Installation & Operating Instructions - 89520 - April 2012 v1.01 Page 7 of 8

Contact Details Head Office Zip Heaters (Aust) Pty. Ltd. ABN: 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia Website: www.zipheaters.com Facsimile (02) 9796 3858 Telephone(02) 9796 3100 Free Call 1 800 638 633 As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. Chilltap Extra- Installation & Operating Instructions - 89520 - April 2012 v1.01 Page 8 of 8