EXICALL EN70MR EXICALL EN70-ATEX (upright version EXICALL EN70MR) (horizontal version EXICALL EN70MR)

Similar documents
EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

EasyAlarm ELEVATOR LEITRONIC AG

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems

User instructions EasyAlarm CONTROL

LEITRONIC AG Swiss Security Systems EasyAlarm ELEVATOR

Memcom Emergency Telephone

ADE Gen4. Speech Dialler Engineering Information. Description. Features

HELPY QUICK-TL GSM INTL

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

MOBILE CALL GSM Alarm System User s Manual

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

l 02-April-2010 For INSTANT CARE

Security GSM Alarm System

Memcom + Emergency Telephone

ALARM SYSTEM USER S MANUAL Rev

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

HELPY CONTROLLER QUICK GUIDE

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

DYGIZONE GJD910 Lighting Controller & Enunciator

Intelligent Wireless GSM Alarm System

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

1. User features of the GSM dialer

DESCRIPTION INSTALLATION

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

User Manual (LS-GSM-006)

IRIS Touch Firmware Enhancements and Additions from Version to Version

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

AT60 AUTO DIALLER User Guide

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS.

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

NESS 5000 SERIES DIALLER

GSM RFID VOICE Alarm System

Contents. Glossary

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

CONTENTS. (User s Manual)

SC-F3G User Manual 1.0

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Basic Installation Manual

HRX Technical Manual. Version 1.2

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

EVO192 v3.0 Fire and Burglary What s New

Version 1.03 January-2002 USER S MANUAL

USER & INSTALLATION GUIDE

RVRC Training Manual Fast Trace Installer Menu

Universal fault annunciator for panel mounting

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

AES IntelliTAP. Model 7068 Digital Dialer Interface A Supplemental Alarm Reporting Device. Version Installation Guide CONTENTS

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

User guide Fire brigade communication system EN 81-72

D169 2-Way Voice Verification Module. Installation and Operating Manual Radionics 34105B 3/97

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

EC-P Zone Intruder Alarm System

Comfort, the Intelligent Home System. Comfort Evaluation Kit

AD1000EN-1R configured to operate as a DG1000

Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Section 9 System Operation

2G & 3G GSM Door Contact Alarm

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

Auto Dialer. Manual E-921APQ E-921GPQ

Installation Manual Premier 412/816/832. Issue 10

Agri-Alert 800EZe. Alarm System. Alarm. System in Standby. Burglary Armed. Online (phone) Green = zone activated Amber = zone bypassed.

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Radio fire warning panel SRC 3000

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Agri-Alert 800 EZe Alarm System Owner s manual

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Destiny Destiny Owners Manual

BURGLAR ALARM PANEL BS-468

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

2000 Series. Program Entry Guide. Control Panels

AVCOM System Installation Instructions

System. For a better understanding of this product, please read this user manual thoroughly before using it.

ProCom The App for Alarm Systems in the Protect Series Operating Manual

1. Introduction. 2. Product overview

JA-63 PROFI Alarm System MGK55402

DigiPlus INSTRUCTION MANUAL

CC408. Quick Reference Guide Solution 880


Installation & Operation Manual March 2017 Rev. 4.1

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

L900 series USER MANUAL

User Manual. with LED Keypad. Alarm Control Panel CA10 plus (software version 4.7) GDAŃSK. ca10pldu_e 07/03

Section 8 System Operation

Transcription:

Use Instruction EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX Order-No. Order-No. Order-No. Order-No. 121.5102 (upright version EXICALL EN70) 121.5103 (horizontal version EXICALL EN70) 121.5104 (upright version EXICALL EN70MR) 121.5105 (horizontal version EXICALL EN70MR) Order-No. 121.5350 (upright version EXICALL EN70-ATEX) Issue 10.2013 Version 8-48

Table of contents Safety instructions..................................... 3 EXICALL EN70....................................... 4 Installation.......................................... 5 Specification sheet..................................... 6 Programming......................................... 8 Installation.......................................... 11 Commissioning...................................... 14 Operation.......................................... 15 Functional description: Elevator alarm........................ 18 Functional description: Door phone.......................... 20 Other Features....................................... 21 Advanced programming................................. 23 Accessories......................................... 29 Specifications........................................ 39 Declaration of conformity................................ 40 2

Safety instructions Telephone connection EXICALL EN70 is designed to connect to an analogue telephone line. This connection must remain in service for at least one hour after a mains power loss according to EN81-28. These are: analogue PSTN analogue port of an ISDN terminal (ISDN-NT has to be reprogrammed for emergency operation at the ab-port) analogue port of a private exchange using UPS (Uninterruptible power supply 1h buffering) GSM Interface with TÜV approval, i.e. EA-GSM-Interface P.37 Multiple EXICALL EN70 sharing one line: Ensure that the first alarm number is always available, because if multiple alarms triggered at the same time it is possible that only first number can be reached A maximum of three units can share one line In case of star cable routing (max. 15 Ω difference per connection = Calc 2 x conductor resistance!) up to 4 diallers can be connected. Example: AWG 24 (U72) = 2 x 90 Ω / km => difference in length max. 15 Ω / (2 x 90 Ω / km) = 0.083km In case of a two-step-dialling-in the number of diallers is doubled P.26 Not suitable: VoIP or cable modem, as in case of power loss it is not functional! The voltage of the telephone network is defined in EN 41003. It is higher than 40 V and therefore please beware for electrical hazard and disconnect the phone line during wiring. Lightning protection interface for landline. P.37 Supply Safety precautions In case of a power loss EXICALL EN70 can still dial calling number 1 using power from the telephone line. The components of the sub-unit EA-LMK and EA-LMK70B are connected to the telephone line potential. Therefore, the connections must be transferred free of soil and net (safety standard EN60950), and may not be touchable (isolation 3.75kV). Check functionality after each changing of parameter or wiring P.14 Please note an alarm by telephone is only successful if the subscriber takes care of the following points: Alarm must not be answered by an answering machine or equal equipment Sometimes connection a mobile phone can be redirected to a Combox (Mailbox) directly or after some ringing-cycles! Do not open housing. Do not bring the device into contact with a liquid (water). 3

EXICALL EN70 View ➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑ Functional elements 1. Speaker 2. Microphone 3. Yellow LED indicates Call is activated S.14 4. Green LED indicates Please speak P.14 5. Call button P.14 incl. backlight P.18 6. Red LED for K2, green LED for K3, yellow LED for K2&K3 P.12 7. Green Mode LED P.8 8. Connections P.12 Meaning of LED indicators Yellow LED Call is activated Green LED Please speak idicates that remote party is listening LED-Mode Green flash: standby Green Ready for program. Red -connection active LED-Output (Relais) Red K2 active Green K3 active Yellow K2 & K3 4

Installation Procedure Proceed systematically. This will ensure that EXICALL EN70 is installs correct and the function is ensured. 1. Complete specification sheet P.6 2. Is EXICALL EN70 pre-programmed or do you program yourself? Self programming P.8 Pre-programmed P.11 3. Montage P.11 4. Commissioning P.14 5. Operation P.15 5

Specification sheet General Information Company: Name: Location: Elevator no.: Profile Please see profile table below.. Dial-in number Telephone line where EXICALL EN70 is connected................ PIN-Code. (Factory setting: 0000) User language German French English Italian Dialling-in procedure with PIN-Code without PIN-Code Serial-No. EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX................ Calling number(s) Periodical test call number Dialling sequence 1:................ 2:................ 3:................ 4:................ 5:................ 6:................ 7:................ 8:......................................... Individual announcement (12 seconds at max) User announcement type...(please see announcement table below) Advanced programming..=.....=... 6

Profile table Profile Type of use Dialing in / Remote access Individual announcement 0 Speed dailing P.20 without PIN-Code None 1 No speed dailing P.20 without PIN-Code None 7 without PIN-Code None No misuse protection P.18 8 without PIN-Code One time No misuse protection P.18 9 without PIN-Code One time Misuse protection P.18 10 with PIN-Code One time Misuse protection P.18 11 with PIN-Code Repeated Mit Missbrauch P.18 Factory default: Profile 10 Programming P.23 = Door phone = Elevator alarm User announcement type Value ANNOUNCEMENT after pressing call button ANNOUNCEMENT during phone connection 0 One time 1..200 201..250 252 253 254 Emergency call activated, you are about to be connected bearbeitet 255 - Activated Repeated every 1..200 seconds Repeated every 201..250 sec. One time Individual announcement + cause of alarm + to stop press 0 to speak press 1 - Individual announcement Factory default for elevator alarm: 0 Programming P.23 Factory default for door phone: 254 7

Programming Preparation 1. EXICALL EN70 will be programmed locally over the microphone using a DTMF-dialler (Touch-Tone-Dialler). Therefore, ambient noise can affect the programming. 2. Connect supply voltage P.12 3. Place Dialler over the microphone. Enable programming 4. Press call button briefly. The mode LED Mode changes from flashing to permanently green. 5. Press key *. on the dialler. The mode LED changes to off. 6. A. You hear one beep followed by the announcement "Programming disabled, PIN". Enter the PIN code (factory setting: 0000) followed by key #.. You will hear two beep sounds and the programming is enabled. Wait for any announcements and continue with step 4.. 6. B. You hear one beep only. EXICALL EN70 is now in programming mode. Start programming sequence by entering first key within 5 seconds, otherwise programming mode is exited (go back to step 4, if you want to proceed with programming). Information on programming Programming will be PIN-code protected automatically after first call started from the EXICALL EN70 to ensure that EXICALL EN70 is protected against unauthorized changes after the installation. The programming mode is left automatically when there will be no DTMF received within 5 seconds (=timeout). As long as the yellow LED is on, you are not able to do any programming. Wait until the yellow LED is off. Programming remains stored even after power-loss. 8

How to program calling numbers *. *. 1. ANNOUNCEMENT *. Calling number according to specification sheet Wait for 5 sec. *. *. 2. ANNOUNCEMENT *. Calling number according to specification sheet Wait for 5 sec. *. *. 3. ANNOUNCEMENT *. Calling number according to specification sheet Wait for 5 sec............... *. *. 8. ANNOUNCEMENT *. Calling number according to specification sheet Wait for 5 sec. You can program up to 8 or 9 calling numbers. If you want to alarm more than the first three calling numbers you have to adapt calling number sequence. P.9 Calling number 9 is used for periodical test call according EN81-28. Digit #. as part to the calling number results in a 5 seconds dialling delay. This may be necessary in combination with a private exchange, when a pause is required after taking an external line. Program calling number as following: Office Number + #. + Phone number If you require Hotline-mode (= private exchange dials telephone number after EXICALL EN70 seizes line) you program calling number 1 with #. only. If the private exchange needs flash-pulse to dial internal numbers you have to program calling number as following: 2. #. + internal number. Calling number 1 cannot be deleted and is the only calling number to be dialled in case of a supply power loss. Digit *. as part of the calling number will result into a Point-IDconnection. P.21 How to program periodical test number According to EN81-28 EXICALL EN70 has to call his service facility at least every 72 hours => periodical test call. Therefore you have to program calling number 9. S.8 *. *. 9. ANNOUNCEMENT *. Calling number according to specification sheet Wait for 5 sec. If the periodical test call is activated EXICALL EN70 calls this number in the programmed interval. P.25 The periodical test can be activated / de-activated i.e. during a remote access (dialling in) using DTMF commands. P.16 How to check calling numbers Check calling numbers i.e. calling number 1 by entering: *. *. 1. ANNOUNCEMENT Wait for 20 sec. 9

How to program calling number sequence The factory default for calling number sequence is 1. 2. 3.. EXICALL EN70 calls the numbers of the sequence consecutively until the call is acknowledged or the end of the sequence is reached. You can adapt the sequence in case you want to call a certain number repeatedly. Examples: Calling number sequence factory setting 1. 2. 3.: Call number 1, then number 2 followed by number 3. Calling number sequence 1. 1. 3. 3. 2. 2. 2. 2.: Call number 1 two times, followed by two attempts on number 2, followed by four attempts on number 3. Calling number sequence 2. 3. 1.: First call to number 2, than number three and number 1 in the end. In case of a power loss only calling number 1 can be dialled. S.8 *. *. 0. ANNOUNCEMENT *. Calling cumber sequence accordign to spec. sheet Wiat for 5 sec. The calling number sequence can contain up to 9 digits. The calling number sequence may be altered using day/night-input (S4). If so, enter calling number other sequence while input signal S4 is active. During operation the calling number sequence follows the input signal on S4. P.21 If a calling number is not programmed or erased, this number will be skipped when still programmed in calling number sequence. In case of a power loss EXICALL EN70 can alarm calling number 1 only. Please make sure that at least on calling number is available in any case at any time, i.e. calling number sequence= 231: Unit powered Calling number sequence 231 In case of power loss Calling numbe 1 only 2: 0#044 1: 0#043 3: 0#079-1: 0#043 - How to program individual announcement / Select language You can record an individual announcement to identify your EXICALL EN70. The optional input <n> allows altering the user language: Press 1. for German, 2 for French, 3. for English, 4. for Italian. *. *. #. ANNOUNCEMENT <n> *. Announcement according to specification sheet #. Wait for 5 sec. The maximum recording time is 12 seconds Depending on the selected profile this announcement will be played once at the beginning of each alarm connection, or repeated every <x> seconds during the connection or even without any announcement (i.e. as door phone) P.7 How to program the PIN-Code The PIN code protects the EXICALL EN70 against unauthorized remote dial-up or programming. It also can be used to identify the unit during phone connection (i.e. commission number of elevator) S.8 #. PIN code accroding to specification sheet #. Repeat PIN code #. The PIN code must be between four and seven digits. The factory setting for the PIN code is 0000. Program a different code for security reasons. 10

Montage Mechanical Assembly Front panel Mounting accessories Flash-mounting front panel: Alum or stainless steel P.29 MDF housing (wall insert) for front panel P.31 Die-cast aluminium box for surface mounting P.32 ABS-enclosure with transparent door for surface mounting P.33 Front panel (Alum) suitable for ABS-enclosure P.34 Flash-mounting front panel (Exitel upgrade cover): stainless steel P.35 11

Wiring The electrical wiring is split into supply, telephone line and the periphery. Proceed as follows: Connect the two-wire shielded phone line. Connect supply voltage. EXICALL EN70 performs a self test. P.14 Start test call. Press call button for one second. P.14 Connect accessory and or input/output. Supply voltage (X12:3 poles) 10 35V DC or 8 25 V AC If you power by mains, us 230V AC power adapter. Line (X1:RJ12) EXICALL EN70: two wire (red/green) MR-type: fore wire (red/green,black/yellow) Twisted and shieled and free from connection to other wires. Call button backlight - Shunt PIN 1 and 2 Input-/Output (X13:12 pole) - Misuse protection signal (S1): Connect signal according to the elevators door state. - External call signal (S2): not ready in case of power loss! - Alarm signal (S3) - Day-/Night switching signal (S4) If you want an individual calling number sequence. - Parallel contact (K1) Potential free contact of call button. - Systeme contact (K2): Connection to a building control system (filtered alarm) or connection of video, light or display "help omes." - Door opener contact (K3): Connect door opening system in case of intercom use. Accessory (X2:RJ45) - Sub-unit EA-LMK: - Sub-unit EA-LMK70B - Potential free external call button 12

Terminals 12 11 10 9 8 7 6 5 4 3 2 1 3 2 1 X13 X12 X2 X1 Supply voltage X12 X12 Description Function PIN 1 GND Earth PIN 2 PIN 3 SP SP Supply voltage 10-35 V DC or 8-25 V AC max. 4 W, arbitrary polarity Telephone line X1 X1 Color Function PIN 2 Black to machine rrom Telefone or remote-unit LMK72B PIN 3 Red to PSTN (connection a) PIN 4 Green to PSTN (connection b) PIN 5 Yellow to machine rrom Telefone or remote-unit LMK72B Leitronic-Accessories X2 X2 Terminal for Leitronic accessories Input/Output X13 X13 Descreption Function PIN 1 BEL White backlight PIN 2 BEL White backlight PIN 3 K3 Relay (Normaly open) i.e. door opener PIN 4 K3 Relay (Normaly open) i.e. door opener PIN 5 KCOM Common pole for relay K1 and K2 PIN 6 K1 Call button parallel contact (Normally open) PIN 7 K2 Filtered alarm contact (Normally closed) PIN 8 SCOM Common pole for signal inputs S1-S4 PIN 9 S4 Day/Night input signal PIN 10 S3 PIN 11 S2 PIN 12 S1 Technical alarm signal External alarm contact Misuse protection signal (i.e. door state) Signal inputs (S1 - S4) Output contact (K1/K3) Normally open Output contact (K2) Normally closed active: 10 V - 40 V AC/DC max. 4 A/50 V AC/DC max. 100 ma/50 V AC/DC 13

Commissioning Connecting supply After power up EXICALL EN70 starts a self-test, checking for.. Telephone line: If no dial tone is detected, you will hear the announcement "phone line failure". Please check phone line. Alarm input S3: If the input is active, you will hear the announcement "Sensor-3 activated. Call Setup connection Hands-free connection Terminate connection Press the call button at least one second to start call. During two minutes EXICALL EN70 tries to establish connection. Adjusting timer P.25. During this time-out the LED Telephone is activated. During connection setup the user announcement will be played once, repeated or ignored depending on selected profile. Adjust user announcement type P.7 If there is not connection please check calling number. P.9 Called party can listen to the user announcement or skip announcement by sending DTMF command 1. or 3. P.15. Doing so activates LED Speak. Check if hands-free communication is fine. Beware of the hands-free connection timeout of 2 minutes P.25. 10 seconds before disconnecting EXICALL EN70 plays announcement Abort. The connection timer can be re-started using DTMF command 1. or 3.. Called party can terminate call by sending DTMF command 0.. Other commands P.15 14

Operation Answer call During connection the called party can initiate remote instructions by sending the following DTMF commands: Play announcements: Individual message / Cause of alarm Status information Switch to hands-free connection 1 2 3 Stop announcements and reload connection timer Deactivated output K2 4 5 6 Activated output K2 Disarm system 7 8 9 Arm system Additional remote commands Table below * 0 # Read out PIN code (Identification) Acknowledge alarm and disconnect Pass on Alarm to next alarm number If more than one alarm number is programmed P.9, the call must be acknowledged /answered by sending DTMF command 0.. Otherwise EXICALL EN70 starts to dial the next alarm number. If you want to pass on the alarm to the next alarm number immediately, you can do so by sending DTMF command 8.. 15

Other remote controls / Elevator alarm and Door phone mode DTMF commands Do not delay more than two seconds between two digits. *. *. 0. Read-out/ Modify calling number sequence (1->-2->3) *. *. 1. Read-out / Modify calling number1.... *. *. 8. Read-out / Modify calling number 8 *. *. 9. Read-out / Modify periodical test number *. *. #. 0. Deactivate periodical test to calling number 9 *. *. #. 1. <n> Activate periodical test to calling number 9 (first time in 72 h or after <n> hours) *. *. #. 2. Start communication test to calling number 9 in two minutes (once only) *. *. #. #. Modify individual message Other remote controls / Door phone Do not delay more than two seconds between two digits. DTMF commands EXICALL EN70 disconnets *. 2. Close contact K3 for 2 seconds Yes *. 3. Close contact K3 for 4 seconds Yes *. 4. Close contact K3 for 8 seconds Yes *. 5. Contact K3 on 3s, off 1s, on 3s Yes *. 6. Close contact K3 for 2 seconds No *. 7. Close contact K3 for 4 seconds No *. 8. Close contact K3 for 8 seconds No *. 9. Close contact K3 until disconnection No *. 0. Disconnect if S1 (door contact) is active If input S1 is active *. 1. EXICALL EN70 disconnects Yes 16

Dialling in/remote access There are two ways of remote access: <with PIN-Code protection> or <without PIN-Code> according to selected profile. P.7 Dialling in/remote access without PIN-Code Dialling in/remote access using PIN-Code 0000 Dial phone number of EXICALL EN70. After selected ringing-cycles P.26 EXICALL EN70 answers call and changes to hands-free connection. This change will be signalled by three gongs and the green Speak -Symbol (EN81-70). So a person inside the cabin will be informed about the established hands-free connection. Dial number of EXICALL EN70. After selected ringing-cycles P.26 EXICALL EN70 answers call and asks for PIN (Default = 0000). If the correct PIN-Code is entered, EXICALL EN70 changes to service-mode where the microphone and speaker remain inactive followed by the announcement to stop press 0, to speak press 1. With key 1. you can change to hands-free-connection. This change will be signalled by three gongs and the green Speak -Symbol (EN81-70). So a person inside the cabin will be informed about the established hands-free connection. Dialling in/remote access: Special mode: Two step dialling in Dial phone number of EXICALL EN70. Let it ring two times and hang-up. Wait for 20 seconds and re-dial phone number. After selected ringing-cycles P.26 EXICALL EN70 answers call! Dialling in/remote access: Special mode in case of power loss In case of a power loss on supply terminal EXICALL EN70 answers call immediately! 17

Functional description: Elevator alarm Elevator emergency call If the emergency call is triggered by pressing the emergency button for at least one second P.24 the yellow indicator is activated. EXICALL EN70 dials the programmed number(s) and established a hands-free connection. When the called party sends DTMF command 1. the LED Speak is activated. ANNOUNCEMENT Emergency call activated. You are about to be connected Call button backlight To activate the push-button backlight short the two BEL terminals. Misuse-Protection (S1) The misuse protection signal is used to separate real emergency calls. During the maximum duration of cabin travel P.24 you will hear the announcement: ANNOUNCEMENT Emergency call activated. You are about to be connected. If the door state changes during this timeout you will hear: ANNOUNCEMENT acknowledged Door is open. Emergency call deactivated. Alarm If the door state does not alter during this timeout EXICALL EN70 starts to dial the calling number(s) playing ANNOUNCEMENT Emergency call activated Factory setting for misuse timeout: 30 seconds. P.24 Misuse-protection is only available when supply voltage is applied. Connection to building control system. P.19 There are two ways to connect misuse-protection signal: 1. Connect voltage following the 2. Use supply voltage SP and connect door state between S1 and SCOM. door contact. SCOM S1 SCOM S1 active: 10 V - 40 V AC/DC SP SP Door contact 18

External alarm signal (S2) SCOM S2 SP SP Alarmcontact Note: This optocoupler input cannot be used in case of a supply power loss. Alternative: Potential free call button (normally open) connected to the subunit EA-LMK/EA-LMK70B or connected using suitable connection cord between PIN 3 and 6 (EXT-terminal). System contact (K2) The normally closed contact (K2) is used in the emergency lift profiles as a filtered alarm (for connection to a building management system) or activate display "Help is coming" display. While K2 is active the LED K2/3 is red or yellow. When K2 is used as in mode "filtered alarm" the contact is activated after the abuses of misuse timeout P.24 and deactivated when the door state changes. When used in mode "help is coming" K2 contact is activated after receiving DTMF command 6. and deactivated when the door state changes or if the alarm remains unacknowledged. Setting the K2 mode P.26. KCOM K2 Periodical test call (WinMOS 300) to management system or "help is coming" lamp 100 ma/50 V AC/DC According to EN81-28 a dialler has to indicate its state at least every 72 hours. EXICALL EN70 can perform this test call towards calling number 9 automatically P.9 The periodical test can be activated during remote access P.17 using DTMF command sequence *. *. #. 1.. P.16 ANNOUNCEMENT Periodical test activated Adjust periodical test timer P.25 Machine room communication (EXICALL EN70MR only) Connect PIN 3/4 of the machine room phone MR- with PIN 2/5 of -LINE terminal X1 of the EXICALL EN70MR. Lifting up the machine room handset starts a hands-free connection with the cabins EXICALL EN70MR indicated by the green LED Speak. Hanging up the handset terminates hands-free connection. By dialling the prefix 0. the handset/modem is connected to the external line. An existing external connection will be disconnected if EXICALL EN70MR has to dial out due to an alarm. In case of dialling-in EXICALL EN70MR can be adjusted to work together with the machine room phone or modem P.17. This functionality mentioned above is only available with applied power. In case of power loss, the machine room handset/modem and EXICALL EN70MR are connected in parallel to the PSTN. Fire brigade solution according to EN81-72 (EXICALL EN70MR only) P.38 19

Functional description: Door phone Door phone (Intercom) A call is triggered by pressing the button for at least one second P.24 indicated by the yellow LED. EXICALL EN70 dials the programmed number(s) and established a hands-free connection. When the called party sends DTMF command 1. the LED Speak is activated. ANNOUNCEMENT Activated Call button backlight To activate button backlight connect the two BEL terminals. Intercom with speed dialling EXICALL EN70 can be used to call individual numbers according to the activated buttons => i.e. call several apartments of a house (intercom). Button T1 to T6 dials corresponding calling numbers 1 to 6. The internal call button of the EXICALL EN70 is equal to button T1. To activate speed dialling select profile 0 P.23 VOC- SP SCOM S4 S3 S2 S1 VOC+ SP min. 10 V T6 T4 T5 T3 T1 T2 System contact (K2) The normally closed contact (K2) is used in all door phone profiles as switching output for video / lighting. If K2 is active LED K2/3 is red or yellow. K2 opens when a call is activated and closes 2 minutes after terminating the connection. Supply KCOM K2 Video/Light Door opener contact (K3) You can use contact K3 to open a door or barrier. If K3 is active the LED K2/3 is green or yellow. There are several DTMF commends to activate/deactivate K3 P.16 K3 K3 to door opener max. 4 A/50 V AC/DC 20

Other Features Service mode connection The service connection is used in case of a silent alarm or remote access. In service mode microphone and speakers remain inactive. This connection mode is used i.e. in case of a technical alarm (S3 P.21) or periodical test ( P.9) and depending on the settings at dialling-in P.27. During service mode DTMF command 1. switches to the hands-free connection indicated by three gong signals. Alarming using alarm protocols EXICALL EN70 supports protocols Point-Contact ID or Contact-ID. Thus, the alarm can be routed to most emergency operations centre. When an alarm is triggered EXICALL EN70 first transmits protocol to first calling number followed by a second call using hands-free connection. Enable Point-ID transmission P.28 Parallel contact (K1) Contact (K1) is the potential free parallel contact of the call button. K1 can be used for the connection to a building control system or a doorbell. KCOM K1 Technical alarm input (S3) to building control system / door bell max. 4 A/50 V AC/DC The response on the alarm input (S3) can be selected according to P.24 If a signal is applied: If a contact is connected: SCOM S3 SCOM S3 active: 10 V - 40 V AC/DC SP SP Day/Night input signal (S4) Two different calling number sequences can be determined depending on the signal at input S4. Program individual calling number sequence, once when S4 is active and once when S4 is inactive. During operation EXICALL EN70 dials calling numbers according to calling number sequence depending on the state of S4 (day/night). If a signal is applied: If a contact is connected: SCOM S4 SCOM S4 active: 10 V - 40 V AC/DC SP SP Alarmcontact Day/Nightcontact 21

Announcement overview Announcement depends on selected profile and can be adjusted according to P.7 Announcement overview: ANNOUNCEMENT Cause Individual announcement Abort Alarm due to S1/S3 Alarm acknowledged To change press star, to stop press hash Output activated Surveillance 1 activated Surveillance 2 activated First announcement in case of an alarm Connection will be terminated Alarm due to signal applied to sensor 1 or 3 inputs If DTMF command 0. was sent User guidance during programming Relay K2 is activated No signal on input S4 (Day/Night) Signal on input S4 (Day/Night) Emergency call activated Emergency call activated by pressing call button Emergency call deactivated, alarm acknowledged PIN Programming deactivated: PIN Programming acknowledged Programming, Abort Line failure Door is open. Emergency call deactivated, alarm acknowledged Failure Unacknowledged alarms: n Calling number Emergency call has been acknowledged or cancelled by changing door state during misuse protection timeout Prompt to enter PIN code Prompt to enter PIN codes to enable programming mode Remote programming successful Remote programming not successful No dial tone present during self test after power up Emergency call is cancelled due to change of door state during misuse protection timeout Erroneous entry during programming. The old value retain active Number of unacknowledged alarms Calling number announcement Calling number sequence Calling number sequence S.9 Periodical test A periodical test call is active S.19 22

Advanced programming Profile selection read/change Attention: Changing these parameters below does influence the operating mode. Therefore only necessary parameters should be changed. Please check behaviour before going into operation. Table with all profiles according P.7 *. 9. 7. 1. 3 0 1 #. #. VALUE *. Value #. Programming profile does not change calling numbers, calling number sequence and individual announcement. But all other parameters and registers and the PIN-code will be set to default value. Factory settings Alarm repetition If you want to reset to factory default please re-program profile. P.23 EXICALL EN70 calls calling numbers according to the calling number sequence P.10 for every new alarm event. You can read-out or modify this register as following: *. 9. 7. 1. 3 5 3 #. #. VALUE *. Value #. Value Description 0 EXICALL EN70 calls calling numbers of the sequence once per alarm even (Factory setting) 1-9 EXICALL EN70 repeats calling number sequence 1 9 times or until the alarm is acknowledged. Announcement type Select announcement type according to table P.7 Note: Different factory settings according to profile! You can read-out or modify this register as following: *. 9. 7. 1. 3 2 0 #. #. VALUE *. Value #. 23

Misuse timeout (sensor S1) If the door state changes within the specified timeout an emergency call will be cancelled automatically. Adjust timeout according to maximum duration of cabin travel. You can read-out or modify timer as following: *. 9. 7. 1. 3 4 8 #. #. VALUE *. Value #. Value Description 20-255 Timer in seconds (Factory setting: 30) Change profile if you want to de-activate misuse-protection! Activation time for call button S2 EXICALL EN70 starts call when the call button has been activated longer as certain time is pressed for a specified time. You can read-out or modify timer as following: *. 9. 7. 1. 3 7 9 #. #. VALUE *. Value #. Value Description 25-255 Activation timeout in 20 ms-steps. (Factory setting: 50 * 20 ms, => 1 second) Technical alarm (sensor S3) The activation type for technical alarm signal S3 can be read-out or modified as following: *. 9. 7. 1. 3 6 1 #. #. VALUE *. Value #. Value Description 1 Announcement Alarm due to sensor 3, in case signal is applied (Factory setting) 3 Announcement Alarm due to sensor 3, in case signal there is no signal applied 24

Dial-up connection time-out During this timeout EXICALL EN70 tries to establish connection. You can read-out or modify timer as following: *. 9. 7. 1. 3 5 0 #. #. VALUE *. Value #. Value Description 1-255 Timeout in steps of 10 seconds (Factory setting: 12 * 10, => 120 s=2 minutes) Hands-free connection time-out During this timeout EXICALL EN70 stays in hands-free connection. You can read-out or modify timer as following: *. 9. 7. 1. 3 5 1 #. #. VALUE *. Value #. Value Description 1-255 Timeout in steps of 10 seconds (Factory setting: 12 * 10, => 120 s=2 minutes) Periodical communication test The timeout between two periodical calls can be read-out or modified as following: *. 9. 7. 1. 3 2 8 #. #. VALUE *. Value #. Value Description 1-254 EXICALL EN70 starts call to calling number 9 every 1 254 * 20 minutes. (Factory setting: 216 * 20min=4320min=72h) Green indicator LED Speak The activation type can be read-out or modified as following: *. 9. 7. 1. 3 6 9 #. #. VALUE *. Value #. Value Description 2 LED Speak will be activated manually during connection using DTMF 1. (Factory setting for elevator alarm). 4 LED Speak is activated automatically after connection is established (Factory setting for door phone). 25

Relay K2 (LMK-OUT) The function of this relay can be read-out or modified as following: *. 9. 7. 1. 3 3 7 #. #. VALUE *. Value #. Value Description 0 K2 inactiv (Factory setting for elevator alarm without Misues-protection) 1 Video/Light (Factory setting for door phone) Relay will be activated by activating call button. Relay will be de-activated two minutes after disconnection. 193 Filtered alarm to connect to master control system (Factory setting for elevator alarm): Relay is activated when alarm is activated (after the misuse timeout). Relay is deactivated if door state as changed. 208 Help is coming : Relay is activated using touch-tone 6.. Relay is de-activated if the door state changes or an alarm remains unacknowledged. Program ringing cycles / dialling-in The number of ringing cycles before EXICALL EN70 answers the call can be read-out or modified as following: *. 9. 7. 1. 3 4 7 #. #. VALUE *. Value #. Value Description 0 EXICALL EN70 does not answer incoming call 2..9 EXICALL EN70 answers call after 2-9 ringing cycles (Factory setting: 2) In case of a power loss this setting is not relevant => EXICALL EN70 answers call immediately. Dialling-in sequence Behaviour on dialling-in mode can be read-out or modified as following: *. 9. 7. 1. 3 7 0 #. #. VALUE *. Value #. Value Description 0 Direkte Ferneinwahl (Werkseinstellung) 1 Etappierte Ferneinwahl 26

Connection mode after dialling-in Phone connection mode after dialling-in can be read-out or modified as following: *. 9. 7. 1. 3 7 1 #. #. VALUE *. Value #. Value Description 0 After PIN-Code-entry Connection in service-mode Handsfree connection using DTMF 1 1 After PIN-Code-entry Connection directly in hands-free mode, indicated by three rings 2 After PIN-Code-entry or time-out 15s Connection in servicemode Hands-free connection using DTMF 1 3 After PIN-Code-entry or time-out 15s Connection directly in hands-free mode, indicated by three rings 5 Without PIN-Code-query Connection directly in hands-free mode, indicated by three rings Remote programming Remote programming of calling number, calling number sequence and individual announcement can be read-out or modified as following: *. 9. 7. 1. 3 7 6 #. #. VALUE *. Value #. Value Description 0 Remote programming disabled 1 Remote program of calling number/ calling number sequence and individual announcement is allowed (Factory setting) Hands-free volume adjustment The EXICALL EN70 hands-free volume can be read-out or modified as following: *. 9. 7. 1. 3 6 6 #. #. VALUE *. Value #. Value Description 0..15 0 is low volume, 15 is maimum volume (Factory setting: 8) Note: Changing this value influences the behaviour of handsfree switching mode. 27

Back-Ground-Noise In case of a loud background noise in the cabin (i.e. ventilator, train station..) you may activate BGN-function to improve hands-free communication: *. 9. 7. 1. 3 3 5 #. #. VALUE *. Value #. Value Description 0 BGN inactive (Factory setting) 103 BGN filter activted Point-ID communication to alarm centre Calling number <n> consists of the telephone number and user account number. The user account no. is separated from the calling number by.*.. *. *. <n> ANNOUNCEMENT *. Calling number + *. + user ccount number Wait for 5 seconds The 1st calling number must not be programmed with point-id communication, as otherwise in case of a power failure there could no voice connection be established. Instead, program the 2nd calling number with Point ID and change calling number sequence i.e. to 2. 1. P.10 Example: 2. Calling number= 0745678901, User account number=3456 Program calling number as following: *. *. 2. and wait for announcement *. 0. 7. 4. 5. 6. 7. 8. 9. 0. 1. *. 3. 4. 5. 6. wait until timeout (5 s). Alarm code for Point-ID for several alarm causes: Code Cause of alarm Zone 120 Call button 902 140 Alarm due to sensor S3 903 601 Test call 900 602 Periodical call (72h) 900 28

Accessories Flash-mounting front panel: Alum or stainless steel Mounting frame made of aluminium or stainless steel fitted for wooden wall inlay box 121.5011. Order-No. Order-No. 121.5010 (plain anodised aluminium) 121.5018 (stainless steel) 29

Wall recess for wall mounting Wall recess and dowel holes for mounting frame / panel. 30

Wooden wall inlay box Wooden box made of MDF for wall inlay. Fitted for front panel 121.5010 or 121.5018. Order-No. 121.5011 31

Die-cast aluminium box (surface mounting) Die-cast alum housing (colour: white) for surface mounting Order-No. 121.5012 32

ABS-enclosure for on-wall mounting with transparent door Housing made of ABS with transparent door and grip closure for surface mounting. Order-No. 121.5030 33

Front panel (Alum) suitable for ABS-enclosure Fitted for ABS-enclosure 121.5030 Order-No. 121.5031 34

Flash-mounting front panel (Exitel upgrade cover): stainless steel Order-No. 121.5008 35

Programming tool Touch-tone dialler (DTMF pad)) Supply voltage: 2 AAA batteries Order-No. 121.5017 DIN-AC-adapter 10 VA (1TE) for up to three EXICALL EN70 or one USV 100.0117 Supply voltage: 230 V AC / 50 Hz Output voltage: 14.3 V DC Nominal power: 10 VA Order-No. 118.0117 Uninterrupted power supply interace (UPS) (2TE) Supply voltage: 14.3 V DC i.e. from 118.0117 Backup: 12 V plump accumulater i.e. 100.0880 Output: permanent 12 V DC 400 ma or one Exicall EN70 switched 12 V DC 200 ma for emegency light Order-No. 100.0117 Plump accumulator 12 V / 1.2 Ah Order-No. 100.0880 AC-adapter 6VA AC-adapter 18 VA Heating Sub-unit EA-LMK Euro-connector AC-adapter for up to 2 EXICALL EN70 Supply voltage: Output voltage: Nominal power: 100 240 V AC/50 60 Hz 12 V DC 6 VA Order-No. 118.0114 Euro-connector AC-adapter for up to 6 EXICALL EN70 or 1 EXICALL EN70 plus 1 heating Supply voltage: Output voltage: Nominal power: 230 V AC/50 Hz 12 V DC 18 VA Order-No. 121.5015 Heater for outdoor use to be mounted to EXICALL EN70. Dimension: 217 x 72 x 20 mm (L x W x H) Supply voltage: Nominal power: Connectors: 12 V 12 VA open ends Order-No. 121.5033 The sub-unit EA-LMK allows starting an alarm call and get in hands-free communication, i.e. as option in big elevators or on top of the cabin. Housing material: ABS Dimension: 112 x 56 x 21 mm (L x W x H) Width including plug: 74 mm Weight: Plug X2: Order-No. 118.0151 100 g (without cable) Emergency button (on telephone potential) 36

Sub-unit EA-LMK70B Same as EA-LMK but with integrated external powered amplifier plus integrated LED or external indicators (yellow/green) according to EN81-70. Supply voltage: Plug X7: Plug X2: 8 35 V DC Order-No. 118.0160 Primary connections Emergency button (on telephone potential) Lightning protection interface (3TE) protects the telephone input of EXICALL EN70(MR) from voltages higher than 150 V and filters ADSL signals. Dimension: 90 x 52 x 30 mm (L x W x H) Weight: 53 g Order-No. 100.0328 Intercom-unit EA-ICOM DECT-Interface GSM-Modules Supply voltage: Nominal power: 230 V AC / 50 Hz 4 W (Standby)/8 W (Operation) Dimension: 165 x 85 x 29 mm (L x W x H) Connectors: Emergency mode: Weight: Order-No. 121.5051 1xPSTN, 4xInternal (Screw terminal) Internal 1 is connected to PSTN over relay in case of power loss 600 g (incl. AC-adapter) The DECT interface establishes a connection between the machine room and an EXICALL EN70 in the cabin. Application: Technology: Supply voltage: Connectors: Diagonal elevators DECT/GAP 230 V AC / 50 Hz Telephone RJ11 The GSM-Modules simulates the analogue telephone line Application: Backup: Connectors: Indicators: PSTN replacement 12 V battery Phone, Supply, Ready: Pluggable screw-terminal GSM-field intensity as LED Protection-housing (IP56) / Supply voltage 230 V AC / 50Hz Order-No. 100.0800 Order-No. 100.0802 incl. modem-interface DB9/USB DIN-housing / Supply voltage 230 V AC / 50Hz or 16 35 V DC Order-No. Order-No. Machine room phone: Machine room solution 1AC.0812 with modem-interface (Accessory) 1DC.0812 with modem-interface (Accessory) Wall mount phone in machine room to get in connection with EXICALL EN70MR in the cabinet. Order-No. 118.0120 37

Remote-unit EA-LMK72B-WG: Fire brigade solution according to EN81-72 with EXICALL EN70MR The remote-unit gives immediate access to the main-units EXICALL EN70MR over a two wire connection (max. wire resistance 15 Ohm). Up to two remote-units can be connected to a main-unit EXICALL EN70MR. Supply voltage: 8 35 V DC Order-No. Order-No. 118.0202B (EA-FWS-Set) 118.0212B (EA-FWS-IP-Box-Set) mounted in protective housing (IP54) with Talk -button and display Special manual available for this application 2 Modem Maschinenraum 2 2 Telefonleitung / Amt Kabine Schacht Externe Notruftaste Missbrauchsunterdrückung Stromversorgung 10..35V DC notstromgepuffert! Optionale zweite Sprechstelle: EA-LMK System-Kontakt Anbindung an ein Gebäudeleitsystem (gefilterter Alarm) Anschluss Hilfe kommt Anzeige Feuerwehrmodus: Speisung: 8-35V DC Feuerwehr Functional description: Key switch activates fire brigade mode. Standby: Microphone in the cabin is active (Speak); Machine room and fire brigade entry are in listening mode. If Speak -Button is pressed the microphone of this location is active (Speak) and the other locations are in listening mode. ATEX-Application Special manual available for this application Main-Unit EXICALL EN70-ATEX Order-No.121.5350 Sub-unit LMK-ATEX Order-No.121.0330 Remote-unit LMK72B-ATEX Order-No.121.0340 II 3G Ex na nl IIC T6 II 3D Ex td A22 IP64 T45 C Ta: 0 C... +40 C Supply voltage: 10-27 V DC 2 or 4W SEV 09 ATEX 0141 X 38

Specifications Supply voltage Voltage range Maximum power 10 35 V DC / 8 25 V AC EXICALL EN70MR: max. 4 W EXICALL EN70-ATEX: max. 4 W EXICALL EN70: max. 3 W Safety regulations Standard EN 60950/EN 41003 Input-/ Output Inputs (S1-S4) NO contacts (K1/K3) NC contact (K2) active: 10 V - 40 V AC/DC in-active: < 3V max. 4 A/50 V AC/DC max. 100 ma/50 V AC/DC Environmental conditions Temperature 0 to 40 C Humidity 20 % - 70 % relative humidity, noncondensing Housing Dimension 80 x 275 x 41 mm (W x H x T) Weight ca. 500 g Approvals European R&TTE Directive 1999/5/EC of 09.March 1999 Telephone line Type Equivalent circuit a,b (analogue) a 820 Ohm 220 Ohm b Dialling mode DTMF 115 nf 39

Declaration of Conformity Declaration of Conformity According to the R&TTE Directive 1999/5/EC of 09.March 1999 Manufacturer s Name: Leitronic AG Manufacturer s Address: Engeloostrasse 16 CH-5621 Zufikon, Switzerland declares that the product Product Name: EXICALL EN70 Model Number: EXI-EN70 EXI-EN70MR EXI-EN70-ATEX conforms to the following product specifications: Safety (R&TTE, Article 3.1a): EN 60950: 1992+A1+A2+A3+A4 EMC (R&TTE, Article 3.1b): EN 50081-1, 1992 EN 50082-1, 1997 Class B Telephone: CTR21 as specified in Council Decision 98/482/EC Supplementary Information The product herewith complies with the requirements of the following Directives and carries the CE marking accordingly: the EMC directive 89/336/EWG the Low Voltage Directive 93/68/EEC Zufikon, 1. Juli 2009 Silvan Tognella 40