Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Similar documents
Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Owners Manual Refrigerated Air Dryer MHT SERIES

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact:

DRYMAX DRYMAX DRYMAX DRYMAX

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

NEWGATE TECHNOLOGIES, INC.

RNP SERIES 33 F 39 F 1 C 4 C OFF OPERATOR MANUAL

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

InstructIon Manual KrEs EQuIPMEnt stands

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Horizontal Bottle Cooler Installation and Operation Manual

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

MODEL MW200 MODEL MW600 AIR DRYER

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

CHILLER. Model CH3000. Operator s & Installation Manual

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Refrigerated Air Dryers

VSA Series Air Dryer. User s Guide

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

R100 Oil-Less Refrigerant Recovery Unit

OPERATING INSTRUCTIONS

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

CH250 AND CH251 CHILLERS

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

PORTABLE AFTERCOOLER MODEL CA-350 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Superdryer Dehumidifiers

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

PDF Created with deskpdf PDF Writer - Trial ::

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CHILLER. Operator s & Installation Manual

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

MDH Series Air Dryer. User s Guide

FAN-FORCED UTILITY HEATER

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Installation & Operation Manual Ice Cream Freezers

RPI Industries, Inc.

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

R Series Cooling Modules

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

PNLDII-28 Condensate Drain Instruction Manual

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

CH750, CH751 & CH951 CHILLERS

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Surna 25-Ton Chiller Operating & Maintenance Manual

DRYAIRE DESICCANT SYSTEM MODEL 6760

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Model H1011.8/H1011.8HPS Water Cooler

A2Z Ozone, Inc. PRODUCT MANUAL

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

MIGHTY PRO 1/4 HP CHILLER

Desiccant Air Drying System

TORRID MARINE YACHT QUALITY Since Owner s Manual

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Corrosion Dry Air Pak

T-Series Air Conditioner T15 Model

BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.

RPI Industries, Inc.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Desiccant Air Drying System

Condensing Unit Installation and Operating Instructions

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

SECTION 50 - CAB CLIMATE CONTROL

Air Dryers & After Coolers Dry Land

Transcription:

Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference. WARNING: Air treated by this equipment is not suitable for breathing without further purifi cation. Refer to O.S.H.A. standards for the requirements for breathing quality air. Figure 1 - F-100 ARROW DRYERS 745 CLARK AVE. BRISTOL, CT 06010 TOLL FREE (877) 640-8300 Form F-0040A Revised 11/04

9 6 2 5 4 8 7 1 3 10 1) Separator 2) Compressor 3) Expansion/Control Valve 4) Refrigerant Filter 5) Hot Gas Valve 6) Fan Motor 7) Power On Light/Switch 8) Dew Point Indicator 9) Power Cord 10) Drain Line 1

Receiving and inspection Arrow Dryers are carefully prepared for shipment at the factory to protect them from damage in transit. Dryers are shipped F.O.B. factory. Immediately upon arrival, check the dryer for possible damage. If damage is found, report it to the carrier and file a damage claim. Check the suction pressure gauge. If the suction pressure gauge reads zero, it indicates a possible refrigerant leak. Notify your dealer immediately. Be sure you have the right dryer. Check the nameplate for voltage and amperage How the Air Dryer Works Compressed air enters the inlet and passes through the air-to-air heat exchanger where the air is partially cooled by the exiting cold air. Next, the air passes through a refrigerant-to-air heat exchanger where it is cooled to near the freezing point of water. As the air is cooled, it loses the capacity to hold water vapor. The water vapor condenses into water droplets and drains to the separator. Passing through the separator, air flow slows down and causes more water to condense and collect in the bottom of the separator bowl. The water is exhausted by the electronic timer drain (see figure 4). The compressed air, now at a pressure dew point of 35ºF, leaves the dryer through the air-to-air heat exchanger where it is heated by the incoming air. Location and Installation Locate the dryer indoors in a protected area where ambient temperature will range between 45ºF and 100ºF. Dryers are usually located near the compressor. Do not cycle the dryer with the compressor. If an aftercooler is used after the compressor, install the dryer downstream of the aftercooler and receiver (see figure 2). Install the dryer so that there is sufficient room around it to permit circulation of air through the refrigeration condensing unit. Allow for easy access into the dryer through the cover panel. Check the nameplate for voltage and amperage. The dryer is furnished with a 6 foot electrical cord for connection to a grounded outlet. Be sure that the compressor air passes through the dryer in the proper direction. Connect the compressed air lines to the inlet and outlet connection as marked on the cabinet. Connect the air lines with standard pipe fittings. The mechanical separator has a isolation valve and strainer to prevent debris from blocking the eletronic timer drain. The electronic timer drain is hard mounted and wired inside the dryer, but is accessible from the left side of the dryer. It is recommended that a bypass line is piped around the dryer. Shutoff valves should be installed at both inlet and outlet, with another valve in the bypass line. This complies with O.S.H.A. lockout regulations and permits the dryer to be removed from the system or serviced without turning off the air supply. Typical Compressed Air Systems 3 Valve Dryer By-Pass Air Receiver Aftercooler Compressor Figure 2 Air Flow Separator w/ Auto Drain Air Dryer Condensate Drain 2

Dimensions F-100 Air Dryer 1 NPT INLET 1 NPT OUTLET F-100 Wiring Diagram 115 V CSIR F-100 Wiring Diagram 230 V CSIR Specifications Model Power Capacity Dimensions Air Line Drain Net Max. Full L.R. No. Supply SCFM (Inches) Conn. Line H.P. Refrig Wt. Press. Load AMP @ 100 PSIG Length Height Width FPT Conn. Charge* Lbs. PSI AMP O.D. F-100-1 115/1/60 100 30 27.5 20 1 3/8 1/2 3 Lbs. 166 250 10.2 51 F-100-2 230/1/60 100 30 27.5 20 1 3/8 1/2 3 Lbs. 166 250 5.36 30 CFC-Free R-134A NOTE: The air leaving the dryer is reheated to 25 F below the inlet air temperature 3

Design Conditions The Dryer must not be cycled with the air compressor. The dryer is non-cycle and is designed to run continuously (even under light loads). If the compressed air system remains pressurized and the air compressor cycles off and on to maintain line pressure, the dryer should remain in operation to keep the air lines dry. Air Flow SCFM: The rated air flow (SCFM) of the dryer is designed for 100 PSIG. Above the rated air flow, the dew point will rise and moist air may reappear downstream. The dryer may cycle off and on under excessive load and cause compressor damage. Inlet Air Temperature: The dryer will function normally up to 100ºF. Above this temperature, the dryer capacity will fall off. Inlet air temperature should be controlled so that it does not exceed 100ºF. Line Pressure: The maximum design pressure is 250 PSIG. Ambient Air Temperature: Locate the dryer indoors in a protected area where the ambient temperature will range between 45ºF and 100ºF. Note: Above an ambient temperature of 100ºF the refrigerant will rise until the dryer shuts down. Several off and on cycles under these conditions will damage the compressor. Automatic Expansion Valve: The automatic expansion valve regulates the refrigerant suction pressure. The expansion valve is factory set between 33 and 36 PSIG. Start UP 1) On initial start-up of system check electrical connections to the dryer, as well as the air piping, so inlet and outlet piping are connected to correct ports. 2) Check panel mounted Dew Point Indicator gauge before starting. The indicator must read above the green area and into the high red section. 3) When ready to operate the compressed air system, the dryer should be started before air compressor is started. 4) When closing the start switch the indicator light on the front panel of dryer will show there is power to the refrigeration compressor. The dew point indicator will slowly drop and hold within the green area the gauge. 5) When pressure has dropped to this level the air compressor can be started and air flow can begin. NOTE: All dryer models are designed to operate without compressed air load in order to pre-cool the heat exchanger surface. NOTE: Operation of dryer is automatic and continuous. Refrigerant compressor does not cycle off and on. Discharge of condensate through drain is automatic. To Stop To stop the unit turn start-stop switch to off position. IMPORTANT: IF IT IS NECESSARY TO PROTECT THE AIR SYSTEM DURING NORMAL SHUT-DOWN THE IN- LET SHUT-OFF VALVE TO THE DRYER SHOULD BE CLOSED TO PREVENT WET AIR FROM ENTERING AIR SYSTEM. How to Make Minor Refrigerant Suction Pressure Adjustments 1) Keep the dryer running under no load and turn off or bypass the compressed air. 2) Remove the dryer cover and locate the control valve (See Figure 3). 3) Remove cap. With 5/16 allen wrench a turn clockwise to increase or counterclockwise to decrease the suction pressure (1/4 turn will normally be enough). Wait 3 to 4 minutes for the suction pressure to settle. Repeat if needed. Replace cap when adjustments are completed. Figure 3 Cap Adjustment Screw External Equalizer Port Inlet Outlet Maintenance and Care NOTE: Refrigerant air dryers require relatively little maintenance if they are used accordance with the installation and operating instructions. Cleaning Fin Surface NOTE: These are air cooled refrigeration systems and depend upon cooling air drawn from the area around the dryer for efficient operation. 1. Inspect the fin surface of the condenser regularly and keep it free of dust, lint or paper. NOTE: A vacuum cleaner or low pressure air hose can be used for regular and normal maintenance of the fin surface. 2. Machine shop applications with oil vapor in the room air may require cleaning with fin surface cleaners available from refrigerant supply houses. Cleaning Timer Drain and Filter Element All models (see Figure 5) have a timer operated drain attached to the bottom of separator bowl. 1. Accumulation of compressor oil in the bowl of the separator as well as the sintered bronze element is possible. Both should be cleaned periodically. 2. Remove foam insulator from separator head. 3. Use a strap or chain wrench to remove the water separator bowl. 4. Drop bowl and remove completely. 5. Clean sintered bronze element with kerosene. 6. Reassemble in reverse order. 7. Close strainer ball valve and relieve drain pressure by pressing test button on timer rain. Remove strainer screen from ball valve assembly located below separator. Clean with compressed air or pressurized water. 8. Test drain by depressing the Test button on the timer. If valve fails to open, or does not seal when closed, close the isolation valve (located near the strainer) and clean or replace the valve. Model F-100 Figure 4 4

TROUBLESHOOTING CHART Symptom Possible Causes(s) Corrective Action Unit will not run. 1. No Power. 1. Correct power supply, fuses, circuit breaker. 2. Internal compressor overload. 2. Feel the temperature of the compressor and allow to cool off if hot. Observe the fan motor. Have the motor checked if it does not run. Clean the condenser. Dew Point Indicator Red Area High 1. Internal compressor overload. 1. Check for air overload. Check inlet air temperature. Check operation of fan motor. 2. High ambient temperature. 2. Check room temperature and hold between 45 F and 100 F. Indicator light off No power to the dryer. Check power supply, fuses, circuit breaker. Dew Point Indicator Red Area Low 1. Low refrigerant charge. 1. Have qualified refrigeration service technician check out dryer or call factory. 2. Low ambient temperature. 2. Relocate dryer to heated area between 45 F and 100 F 3. Low hot gas valve setting. 3. Re-adjust hot gas valve to the green area on the dew point indicator gauge. (See minor pressure adjustments) High pressure drop 1. High air flow. 1. Air flow above rated flow of dryer. 2. Drain valve not discharging. 2. Manually blow down drain until water flow stops. Clean drain. 3. Freezing moisture in evaporator. 3. Re-adjust hot gas valve to the green area on the dew point indicator gauge. (See minor pressure adjustments) 4. Plugged separator element or drain. 4. Clean or replace. Water downstream of dryer 1. Compressed air is flowing through 1. Dryer must be operating 5-10 dryer before it is turned on. minutes before compressed air load. 2. Dirty separator element or drain. 2. Disassemble and clean. 3. Overload dryer above air flow 3. Reduce air load to dryer capacity. specifications.* 4. High suction pressure. 4. Inlet air temperature too hot. 5. Low outlet air pressure. 5. Freezing of water, adjust suction pressure.* 6. Low refrigerant charge. 6. Contact service technician to leak check. NOTE: Check or repairs of the refrigeration system must be done by a qualified refrigeration service technician with the required gauges and other equipment. *All adjustments must be made under no compressed air load. 5

If Trouble Starts If the dryer cycles off and on for any reason TURN OFF THE DRYER. Call the factory for instructions, Check or repairs of the refrigeration systems must be made by a qualified refrigeration service technician. Before calling the factory for instructions, have the following data to report. Model No. Serial No. Refrigeration Suction Pressure. REPLACEMENT PARTS Model F-100-1 F100-2 Voltage 115/1/60 230/1/60 Compressor Make Copeland R-134A Copeland R-134A Separator/ Drain Assembly PART NUMBER PART NUMBER Separator FK329-S1 FK329-S1 Separator Bowl 3110-S1-8 3110-S1-8 Repair Kit RFK329 RFK329 Element Kit EKF329 EKF329 Electronic Timer Drain 27901 27902 Refrigeration System Condensing Unit 14582 14575 Compressor 14769 14770 Expansion Valve 14571 14571 Hot Gas Bypass Valve 91233 91233 Refrigerant Filter 14576 14576 Electrical Fan Motor 95933 95936 Fan Blade 95941 95941 Fan Switch 91639 91639 Power On Light/Switch 97846 97846 Power Cord 91698 --------- Gauges Dew Point Indicator 14765 14765 Cabinet Panels Base Panel 14640 14640 Cover Panel 14642 14642 Back Panel 14641 14641 End Panel Right Side Vented 14649 14649 End Panel Left Side Vented 14643 14643 6

ORDER REPLACEMENT PARTS BY CALLING (877) 640-8300 Please provide following information: Model Number Serial Number (if any) Part Description and Number Address parts correspondence to: ARROW DRYERS 745 Clark Ave. Bristol, CT 06010 WARRANTY POLICY When used under the conditions recommended by the manufacturer, Arrow Dryers, this model is warranted to be free from defects in material and workmanship for a period of twenty-four (24) months from date of receipt, not to exceed thirty (30) months from the factory ship date, provided Arrow is furnished the customer s name, address, and date of shipment information These units will utilize either a braze plate or modular type heat exchanger which will be warranted for five (5) years. This warranty is limited to the replacement of the heat exchangers, F.O.B. Factory, and subject to the same restrictions as outlined below concerning misuse, abuse or accident. The automatic drain carries a 90-day warranty. This warranty will apply to equipment installed, operated and maintained in accordance with the procedures and recommendations as outlined in the owner s manual published by Arrow Dryers. During the life of this warranty, Arrow Dryers will repair or replace (at Arrow Dryers option) any defective part or assembly, free of charge, F.O.B. its plant if such defect occurred in normal service and was not due to apparent misuse, abuse or accident. Any warranty service performed in the field must be authorized by Arrow Dryers, Unauthorized service voids the warranty and any resulting charge will not be paid by Arrow Dryers. Arrow Dryers makes no other warranties or guarantees, expressed or implied. The merchantability of the components is expressly excluded. The manufacturer assumes no liability for indirect or consequential damages. 7