November This product has been reconfigured Please read these instructions

Similar documents
Thank you for choosing EnviroVent

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Watch the heatsava video

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

HOTLINE:

Thank you for choosing EnviroVent

Wiring the fan correctly...

Wiring the fan correctly...

HOTLINE:

Thank you for choosing EnviroVent

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

ECo 2 Wall USER GUIDE FOR RESIDENT

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Introducing the RetroVent

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Lo-Carbon SELV Tempra

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

KUDOS. Instruction leaflet

Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen

CLASSIC-100. Instruction leaflet. Instruction leaflet

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

GUH90 90 cm Canopy Hood

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Stainless Steel Chimney Extractor

Xpelair Simply Silent TM Contour Fan

Stainless Steel Chimney Extractor

GUH52SD 52 cm GUH75 75 cm Canopy Hood

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

Xpelair Simply Silent DX150

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Centrif Duo & Centrif Duo Plus

Xpelair Simply Silent TM DX100 Fan

60cm Chimney Extractor

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

ECO dmev Decentralised MEV

Stainless Steel T-Box Extractor

60cm Integrated Turbo Extractor

Lo-Carbon Quadra Centrifugal Fan

Filterless Extract Fan. WC, Bathroom + Kitchen

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Xpelair Simply Silent DX100B

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

WHHR Midi & Midi Lite

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Xpelair Simply Silent DX100

Installation and Maintenance

Cyclone 7 Designed to Perform. Built to Last. WC. Bathroom & Kitchen

Purge Ventilation Unit. Product Manual. ventilation systems TP625

BFR6 / BFR9 Rangehood

INSTRUCTIONS FOR USE

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

BT16.4SS-HK BT19.4SS-HK Cooker Hood

INSTRUCTIONS AND WARRANTY

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Lo-Carbon Quadra SELV

UBGHFF60W 60cm Gas on Glass Gas Hob

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

90cm Chimney Extractor

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Autofill Wall Mount Boilers

condensation mould high humidity

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

22.2V Turbo Lite Ultra Cordless Handheld Vacuum

EZT90BL Extractor. Installation, Use and Maintenance.

Installation & Operating Instructions

BLOW DRY & GO HAIR KIT

Noirot Spot Plus Digital Timer

User s Operation Instructions & Important Warranty Information

Installation and Maintenance

Warnings, Safety Information and Guidance

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Installation and Maintenance

Turbo Cyclonic Pro Bagless Cylinder Vacuum Cleaner

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

User Manual for your GEH6017 & GEH9017 Cooker Hood

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

60cm Canopy Extractor

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

Lo-Carbon Quadra Centrifugal Fan

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Compact Cyclonic Bagless Cylinder Vacuum Cleaner

Compact Cyclonic Bagless Upright Vacuum Cleaner

Turbo Vac Pro 18V 2 in 1 Cordless Cleaner

Installation and Maintenance

Transcription:

November 2013 This product has been reconfigured Please read these instructions

Contents Page 01 Introduction 2 02 Box Contents 3-4 03 Tools Checklist 5 03A Pre-Installation Checklist 6 04 Controls 6 05 Technical Specifications 7-8 06 Safety 9 07 Pre-Installation 10-11 08 Installation 12-24 Installation with wall seal 15-16 Installation with wall sleeve 17 09 Cleaning & Maintenance 25-27 10 Guarantee 28 11 Warranty 28 12 Wiring Diagrams 29-30 01 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK Ensure that this product is treated with care, installed and maintained correctly i.e. for the life of the building. Remember, if you have any problems please call our dedicated Technical Team. Gold Standard After Sales Service In the unlikely event of any on-site installation problems or queries regarding the EnviroVent heatsava, just call our hotline number. We will take your details and appoint a regional installation manager to call you back to discuss the problem. In the majority of cases, the problem can be resolved over the phone. However, in cases where the problem cannot be resolved over the phone, we will arrange a visit from our Gold Standard Engineer. They will meet with your contractor/direct labour on-site to discuss and resolve the problem, will provide training and also give advice on the installation of the unit. INSTALLER HOTLINE: 07540 050 147 AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 02

02 Box Contents 1 heatsava Unit 2 Heat Cell 3 Instructions Guide 5 Halo 6 Wall Seal 7 Fixing Kit 4 SELV (optional) 03 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

02 Box Contents Description Quantity Item heatsava Unit 1x Heat Cell 1x Instructions Guide 1x SELV (optional) 1x Halo (Wall Kit Contents) 1x Wall Seal 1x Fixing Kit 1x 8G X 2.0 - (Fixing Kit Contents) 6x Red Wall Plugs - (Fixing Kit Contents) 6x Terminal Block (Spare) 1x AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 04

03 Tools Checklist (Not supplied) Description Item Core Drill Electric Screwdriver Long & Short Screwdriver Small Terminal Screwdriver Spirit Level Cutting Pliers Long Nose Pliers Ladder Solvent Cement Silicone 05 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

03A Pre-Installation Checklist Boiler flue exclusion zone heatsava installation instructions have been read and understood Check unit size is suited to wall depth Use the template to position and orientate the unit Drill the core hole and 3 fixing holes as straight as possible Follow the instructions for installing the unit Ensure the unit s trickle and boost modes are working Ensure all electrics are safe The halo is properly fixed to the exterior wall The unit is securely fixed into position with enough space left for servicing Inform building owner/user on how to operate and maintain the system These checks are required to ensure the proper function of this unit. For EnviroVent Technical help call 0845 27 27 810 04 Controls Intelligent Humidity Tracking (Automatic) The heatsava has been engineered with intelligent controls to think for itself, meaning that you don t need to press any buttons or light switches to turn it on. When the heatsava senses a rise in humidity, caused by increased moisture generation such as through cooking or showering, the extract and supply airflows will slowly begin to increase in direct proportion to the increase in humidity. It will then automatically track back down again when humidity falls. This controls condensation quietly and efficiently. Pullcord (Manual) The heatsava comes complete with a pull cord to activate the boost if required. Pull once to activate the boost and once to deactivate. Summer Mode (Automatic) During warmer days, the heatsava prevents warm air from entering the room and switches to provide extract ventilation only. As the temperature falls it automatically returns to heat recovery mode. Frost Protection (Automatic) The heatsava has an automatic built-in frost protection mechanism to prevent any damage to the heat exchange cell in cold conditions. AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 06

05 Technical Specifications Unit Dimensions Rear Assembly (Extract Fan) Centre Assembly (Electronics) Front Assembly (Supply Fan) Fan Adaptor Cowl End Heat Cell 07 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

05 Technical Specifications Heat Cells Options B Ø100 A Wall Depth mm (A) Cell Order Size mm (B) 100-310 310 311-430 430 431-500 500 501-600 600 B Ø150 A AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 08

06 Safety Be sure to have read and understood these instructions before beginning the installation process. Electrical Assembly When wiring the unit in, a suitable disconnect device such as a fused spur should be used, do not use a plug. The means of disconnecting the unit from the mains power supply must be incorporated in the fixed wiring in accordance with the wiring rules. There must be a necessity to allow disconnection of the appliance from the supply after installation, unless the appliance incorporates a switch complying with the wiring regulations The disconnection may be achieved by incorporating a switch in the fixed wiring in accordance with the wiring regulations. The electrical install comprises of a power supply unit (Fig.1) or a low voltage box - SELV (Fig.2). See pages 29-30 for wiring diagrams. Any replacement cords have to be fitted by a competent tradesperson. Connect 2 core & earth cable into existing wiring Fan Board Power Supply IPX4 Rated This unit has been tested to IPX4 and is suitable for installation within Zone 1 of bathrooms. However, we recommend that you must not position the unit above any water devices such as taps, shower heads or jets and ensure water is not aimed directly at the unit. Do not use jets or shower heads etc to clean this unit. MAINS Never modify the fan or electronics Do not store inflammable products in the vicinity of this product This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. For a bathroom application the power supply should be installed outside the bathroom as it is 230V. IMPORTANT: This unit draws air in from atmosphere and you must ensure that any emissions from any other systems such as gas or oil boilers, do not contaminate the air entering the heatsava product. Therefore, before installation, consider where the external cowl will be located in relation to any boiler flues etc. Externally, you must ensure that the unit is positioned a minimum distance away of; 1 metre horizontally, 1 metre below or 3 metres above any boiler flue etc. In kitchens, if the unit has to be fitted above a cooker, it must be installed a minimum distance of 650mm above electric cookers and 750mm above gas cookers, and not have a pullcord fitted. 2 core Fig.1 SELV Connect 2 core cable from SELV box into unit Fig.2 2 core & earth Connect 2 core cable into SELV SELV Box 09 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

07 Pre-Installation Introduction Designed for through the wall installation, the heatsava is ideal for both refurbishment and new build properties. The outside diameter of the heat exchange casing is smaller than a standard wall sleeve and can therefore utilize an existing one already in place. The heatsava also takes into account the complexities of different wall depths to offer 4 different main lengths that the heat exchange casing is manufactured to (see page 8). The unit is installed from the inside out to allow for ease of installation in high-rise applications. Built with intelligent humidity tracking controls means no user intervention is required and heatsava silent-night mode prevents noisy running at night. The heatsava is exceptionally versatile and can be installed horizontally or vertically in 4 different positions through 360 (Fig.3). 12 Heat Cell Orientation When fitting the heat cell into a wall, ensure that the cowl end is correctly orientated with the end always facing down. (Fig 4.) Fig.4 9 Cell Cell 3 Clearance The heatsava has been designed to allow easy installation into an existing wall sleeve which is located near the ceiling. When core drilling into an existing wall, make sure you have enough space to move around and distance between the wall and any objects nearby i.e cupboards (Fig.5). heatsava LEAVE ADEQUATE CLEARANCE Fig.3 Pre-Installation Checklist 6 cupboard Before starting the installation process, ensure that you have all the necessary equipment and the following: Fig.5 Plan layout Check wall depth heatsava Unit Heat Cell Fixing Kit Wall Seal Kit Low Voltage Box (optional) Choose position and orientation Ensure the unit is sited in a suitable position for adequate clearance on all sides for easy access to the unit for maintenance purposes and to ensure that access to the release clips on the front cover is not inhibited. AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 10

07 Pre-Installation Clearance First measure the wall depth. If installing into a new build application, we recommend that the unit should be installed in the position below (option 1). If installing into an existing wall sleeve which is located near to the ceiling, the heatsava can be installed horizontally or vertically (options 2-4). Ceiling 20mm min 20mm min Cover release clips Option 1 Option 2 Ceiling 30mm min 30mm min Option 3 Option 4 11 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation 2 4 Cell? 3 1 Read instructions Check orientation OPTION B - For OPTION A, go to page 21. For quick and easy installation use 3 x holes marked B. If the fixing surface is of poor quality and holes B cannot be used, then use holes A. To access holes A the unit needs to be disassembled. X3 heatsava 100 or 150? 107mm, 117mm, 158mm, 162mm? See pages 15-17 for seal or sleeve installation AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 12

08 Installation X4 13 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation Solvent Cement (not supplied) AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 14

08 Installation Rubber Wall Seal - Choose rubber wall seal or wall sleeve installation. 117mm or 162mm Ø =X =X 15 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation Solvent Cement 117mm or 162mm Ø AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 16

08 Installation Wall Sleeve Wall sleeve not supplied A 99mm (100) or 149mm (150) Ø overall B 100mm or 150mm Ø internal (min) Use existing sleeve or insert new sleeve into wall. C X 107mm or 158mm Ø X Cement =X A B Wall sleeve C Apply cement around sleeve and insert through wall. =X 17 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation Pullcord - See page 11 for pullcord options. Option 3 & 4 Option 1 & 2 Fit cover AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 18

08 Installation 19 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation External Silicone (not supplied) AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 20

08 Installation OPTION A Front assembly: Remove badge and screw Fan adaptor: Remove 4 screws 21 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation Cell assembly: Remove 4 screws Electronics lid: Remove 3 screws AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 22

08 Installation Disconnect fan Centre assembly: Remove 6 screws 23 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation Drill holes A. heatsava 100 or 150? 107mm, 117mm, 158mm, 162mm? See pages 15-17 for seal or sleeve installation Use holes A and fix rear assembly to wall. Fix 6 to wall then put assembly back together. Reverse steps 7-24 from page 13 AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 24

09 Cleaning & Maintenance Cleaning General cleaning of the vents and cells should be every 6 months max, or as required, as environments will vary. Service Maintenance Intervals General maintenance should ideally take place every 12 months and should be carried out only by a competent tradesperson adhering to the instructions. 5 Year Service The heat exchange cell and all components and parts should be inspected every 5 years. Remove fan adaptor by using 4 screws 25 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

09 Cleaning & Maintenance AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 26

09 Cleaning & Maintenance Damp cloth Soft brush Vacuum 27 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

10 Guarantee The EnviroVent heatsava is covered by a full 5 year warranty which will benefit the occupier over many years. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your heatsava is not working correctly, you can telephone 0845 27 27 810 (operational from 8:00am to 5:30pm Monday to Friday), and ask for technical assistance. You will either be given guidance over the telephone, or an arrangement will be made for an engineer to visit. In any event, please have the following information ready. This will enable your call to be dealt with quickly and efficiently. Serial number of the unit: 11 Warranty We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. We are confident that you will be delighted with the performance of the system and the resulting improvement in air quality in your home after the installation of the unit. Your warranty covers any defect or break down that arises due to faulty materials or construction. WARRANTY CONDITIONS AND EXCLUSIONS The system must be correctly installed and operated according to the instructions contained in the user guide supplied. The warranty will be rendered invalid if the system has been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by EnviroVent Ltd. The warranty will be rendered invalid if the unit is turned off. Turning the unit off can damage it. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The guarantee will only be honoured from approved suppliers. AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 28

12 Wiring Diagrams Mains - This unit must be earthed Connect 2 core & earth cable into existing wiring 29 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

12 Wiring Diagrams SELV - This unit must be earthed 2 core SELV 2 core & earth Connect 2 core cable from SELV box into unit Connect 2 core & earth cable to exisitng wiring SELV Box GND Power Supply 2 core 2 core & earth V+ SELV Box must be secured using the 4 fixing points GND V+ AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 30

EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA 01423 810 810 info@envirovent.com www.envirovent.com Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.