Level gauges Series LS Level indicator, switch and transmitter for liquids

Similar documents
Dräger Polytron 7000 Fixed gas detector

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Dräger Polytron 8000 Stationary gas detector (EC)

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Direct reading flowmeters type RM

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Enraf Servo Gauge 854 XTG

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3051CFC Compact Flowmeter

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Rotameter series 250 metal tube variable area flowmeter

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Mobrey MCU900 Series Universal Control Unit

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Enraf Servo Gauge 854 ATG

Rosemount 3490 Series

Rosemount 3051CFP Integral Orifice Flowmeter

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8000 Stationary gas detector (EC)

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Instrumentation Products and Applications

Process Alarm Module RTA 421

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Level Measurement Continuous level measurement Ultrasonic transmitters

Nuclear Density Gauges

Sitron s CF Line of Flow Switch Monitors

Analog Transmitter AT1000 AT1

High Pressure Conductivity Monitor

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Certificate of Compliance

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Rosemount 3051L Level Transmitter

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Dräger Polytron 8200 Stationary gas detector (CatEx)

Rosemount 2051T In-Line Pressure Transmitter

HTC-915-CONT. Heat-Trace Control system

OPTIBAR DP 7060 Supplementary Instructions

Process & TeMPerATUre UniversAl input DigiTAl MeTers

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Indoor/outdoor resistance thermometer Model TR60

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Electronic Pressure Digest. Pressure and Temperature Transmitters

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Continuous level measurement - Radar transmitters

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Dust Alert 75. *shown with optional external keypad and display

industrial electronics electronic level measurement system

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Rosemount 2051T In-line Pressure Transmitter

Danfoss gas detection unit Type GD Heavy Duty

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Dissolved Oxygen Measurement liquisys M COM 223 / 253

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Rosemount 3100 Series Ultrasonic Level Transmitters

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Temperature Measurement

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

ULTIMA X5000. MSAX5000.com

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Engineering Guideline. pac- Carriers Type Universal

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Dräger PIR 7200 Toxic Gas Detection Transmitter

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Labkotec automatic warning devices for separators protecting the environment

Ar-Mite TM Low Flow Armored Flowmeter

Flow Measurement SITRANS F C

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

Druck DPI 705/DPI 705 IS Series

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Dissolved Oxygen Analyzers

Rosemount 3100 Series Ultrasonic Level Transmitters

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Model D12-IR. Digital Gas Transmitter...

SECTION Fluorescent Dissolved Oxygen Measuring System

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Instrumentation and Controls Group

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Danfoss gas detection Controller unit

Introduction to Flow Switch

Transcription:

Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm to 15 m Accuracy: ±4 mm measured value Connections: - EN 1092-1 or ANSI flanges. Other flange standards on request (JIS,...) - BSP or NPT threaded connections Materials: EN 1.4404 (AISI 316L). Others on request Local indication: - By means of external float in a glass tube - By means of magnetic strips Options: - Switches - Electronic transmitter with 4-20 ma analog output for safe or hazardous area (Ex ia IIC T6 protection, ATEX certified). HART, PROFIBUS, FIELDBUS protocols available on request, also in Ex ia versions

Working principle A float connected to a guide tube with an internal magnet assembly on its side moves along a chamber, changing its height according to the level of a liquid inside a tank. The float is designed for the specific working liquid density. The internal magnet assembly couples with an external float or with a magnetic strips rail mounted externally and isolated of the level gauge chamber, providing an indirect tank level indication. It can also activate the electronic accessories that are optionally supplied together with the level gauge. LS20 LSL20 LS21 LSL21 glass tube indication, flanged connection magnetic strips indication, flanged connection glass tube indication, threaded connection magnetic strips indication, threaded connection 2 Applications Chemical and petrochemical industries Process industry Thermal plants and cryogenic installations Storage installations Models LS.../ : indication by means of external float in a borosilicate glass tube. Graduated scale in cm included. Maximum liquid temperature for AISI 316L versions: 400ºC LSL.../ : indication by means of bi-color magnetic strips (red-white) mounted in an anodized aluminium rail with polycarbonate cover. Optional graduated scale in cm. Maximum liquid temperature for AISI 316L versions: 250ºC Technical data Accuracy: ±4 mm measured value Scale in cm for LS models. For LSL models, scale in cm available on request Liquid density: 0.55... 2 kg/l (others on request) Measuring range: 150 mm... 15 m Liquid temperature: - LSL20 21: -20ºC... 250ºC - LS20 21: -20ºC... 400ºC, depending on config. Working pressure: PN16 for AISI 316L models Connections: - EN 1092-1 or ANSI flanges. Other flange standards on request (JIS,...) - BSP or NPT threaded connections Mounting: on top of the tank Special design with guided float for rod longer than 2000 mm and mechanical protection in case of waves inside the tank Limit switches and transmitters LT... LTL-APR: adjustable reed switches LT... LTL-AAR: adjustable reed switches (high temperature version) LT... LTL-AMM: adjustable micro-switches LT... LTL-AMD: adjustable inductive switches (+ relays on request) LTE: Resistive sensor transmitter. 4-20 ma output: - TR3420: 24 VDC 2-wire system with compact converter, for safe area or ATEX Ex ia IIC T4 or T6 certified - TR2420: 24 VDC 2-wire system with compact converter and HART, PROFIBUS, FIELDBUS,... protocols and also ATEX Ex ia IIC T6 certification on request

Level gauges Series LS Float types The selection of the float for each application is made according to the specific application conditions, such as liquid density and height to be measured. The diameter of the selected float determines the minimum connection size required for the correct installation of the series LS level gauge as well. Please consult factory. Materials Models LS Models LSL DETAIL A Nº Description Models LS20 21 Models LSL20 21 EN 1.4404 (AISI 316L) EN 1.4404 (AISI 316L) 1 Body EN 1.4404 EN 1.4404 2.1 Guide tube Borosilicate glass 2.2 Mag strips rail Aluminium + Polycarbonate 3 Internal magnet assembly EN 1.4404 EN 1.4404 4.1 External float PP / Aluminium 4.2 Mag strips POM resin 5 Connection EN 1.4404 EN 1.4404 6 Rod EN 1.4404 EN 1.4404 7 Float EN 1.4404 EN 1.4404 3

Dimensions Models LS LSL20 Models LS LSL21 Models LS LSL20 guided Mounting LMT: minimum distance necessary to remove the level gauge Series LS 4

Level gauges Series LS Limit switches Adjustable switch LT... LTL-APR SPDT bi-stable reed switch IP65 polycarbonate housing Contact rating: 0.5 A 220 VAC 60 VA Liquid temperature: -20ºC... 200ºC Ambient temperature: -10ºC... 70ºC Suitable for hazardous area, considered as Simple apparatus LT... LTL-APR Adjustable switch LT... LTL-AAR SPDT bi-stable reed switch Aluminium housing & thermal separator for high temperature Contact rating: 0.5 A 220 VAC 60 VA Liquid temperature: -20ºC... 400ºC Ambient temperature: -10ºC... 70ºC Suitable for hazardous area, considered as Simple apparatus LT... LTL-AAR Adjustable switch LT... LTL-AMM SPDT bi-stable micro-switch IP65 coated aluminium housing Contact rating: 3 A 220 VAC Liquid temperature: -20ºC... 200ºC Ambient temperature: -25ºC... 80ºC Mechanical life: 20 x 10 6 operations Suitable for hazardous area, considered as Simple apparatus LT... LTL-AMM / AMD Adjustable switch LT LTL-AMD NAMUR (EN 60947-5-6) 3.5 mm slot type inductive detector activated by vane, mounted in an aluminium housing. Power supply: 8 VDC Liquid temperature: -20ºC... 200ºC Ambient temperature: -25ºC... +70ºC ATEX certification Ex ia IIC T6 Control relay (on request) NAMUR (EN 60947-5-6) for 1 or 2 inductive detectors. Power supply: 24 253 VAC 50-60 Hz / 24 300 VDC Input: NAMUR Ex ia IIC Output: 1 or 2 relay contacts Output rating: 2 A 250 VAC 100 VA / 1 A 24 VDC Ambient temperature: -25ºC... +70ºC 5

Transmitters Transmitter LTE 4-20 ma Transmitter composed of a resistive sensor based on a reed and resistances chain, mounted on a printed circuit placed inside a guide tube. Not wetted by the process liquid. Variations in level inside the tank move the internal magnet assembly of the LS or LSL indicator, which by means of magnetic coupling changes the value of the resistance of the resistive sensor in correspondence to the measured liquid level. These variations of resistance are processed by an electronic converter in order to obtain a 4-20 ma current output proportional to liquid level. Technical data LTE Connection by means of IP65 connector, IP67 polycarbonate housing or IP67 aluminium housing Distance between reed switches: 10 mm Liquid temperature: -20ºC... 250ºC Ambient temperature: -20ºC... 60ºC TR3420Ex hazardous area version ATEX Ex ia IIC T4 or T6 - Power supply: 8... 30 VDC TR2420H (HART protocol), TR2420P (Profibus protocol) or TR2420F (Fieldbus protocol). Also available in combination with their Ex ia versions Electronic converter Model MT03L Electronic converter for level applications Resistance and current inputs Programmable via USB cable by means of Tecfluid S.A. Winsmeter MT03 software or by means of keyboard and graphic display with intuitive menus Power supply: 90 265 VAC 50 / 60 Hz 18 36 VDC Full diagnosis and optional password Panel mounting Dimensions 96 x 96 mm DIN 43700 Ingress protection: IP50 front, IP30 back (Optional IP65 front with silicone cover) Ambient temperature: -20ºC... +60ºC 5 digits level indication Programmable 4-20 ma analog output 2 x relay outputs programmable as level alarms Converters series TR 2-wire system with 4-20 ma output TR3420 safe area version - Power supply: 12... 36 VDC - Consumption: 0,8 W - Local configuration by means of USB connection and Winsmeter TR software available for download at www.tecfluid.fr R-CT-LS Rev. 0 english version Quality Management System ISO 9001 certified by Pressure Equipment Directive 97/23/CE certified by ATEX European Directive 94/9/CE certified by HART is a registered trademark of HART Communication Foundation The technical data described in this specification sheet is subject to modification without notification if the technical innovations in the manufacturing processes so require.