GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Similar documents
GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Ruud Acheiver Series Upflow Gas Furnaces

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES. Visit taxcredit for complete details.

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Multi-Position Gas Furnaces

Rheem Classic Plus Series Multi position Gas Furnaces

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Ruud Achiever Plus Series Multi-position Gas Furnaces

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE

Rheem Classic Series Multi-position Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Multi-Position Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

OIL FURNACES PREMIUM CLASS UPFLOW OIL FURNACES. ROBF- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to kw]

INTEGRATED HVAC & WATER HEATING

TECHNICAL SPECIFICATIONS

Ruud Ultra Series EcoNet Enabled Two-Stage Variable Speed Multi- Position Gas Furances

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

Hydronic Air Handler Powered by Tankless Technology

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

RG7D 1-Stage Heat Series

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Hydronic Air Handler Powered by Tankless Technology

Rheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor

Hydronic Air Handler Powered by Tankless Technology

Comfort, Quality and Efficiency.

Wt. Lbs Model Number (BTUH) Hz

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

MERIT SERIES Downflow

Energy Saving. Space Saving.

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Cooling Capacity CFM in. w.c. (125 Pa)

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Cooling Capacity CFM in. w.c. (125 Pa)

G34M Bulletin #69/ August 2003

395CAV Sizes 045 thru 155 Series H and J

AIR HANDLERS AIR HANDLERS

ELITE SERIES Downflow - High Efficiency Blower Motor

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

8+* Bulletin No November 1997

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

Cooling Capacity CFM range

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

Transcription:

FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1 GAS FURNACES RGLT- SERIES Models with Input Rates from 75,000 to 125,000 BTU/HR [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency - AFUE THIS MODEL 80.0% ENER UIDE MID HIGH 78% 82% 88% 97% ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR The Ruud Achiever Series Super Quiet 80 line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by CSA International. Features Innovative design results in reliable, efficient operation at sound levels which provide distinct competitive advantage. Patented heat exchanger, constructed of both stainless and aluminized steel for the maximum in corrosion resistance. Low profile 34 inch [864 mm] design is lighter and easier to handle, and leaves room for optional equipment. Left or right side gas and electric inlet connections with quick, simple change. Direct Spark ignition. Integrated board with humidifier and electronic air cleaner hookups. Insulated blower compartment helps to reduce jacket loss and noise. Pre-paint galvanized steel cabinet. Molded permanent filter. Grab-holes in doors to aid in easy door removal and replacement. ECM X-13 Blower Motor. A variety of cooling coils and plenums designed to use with Ruud Achiever Series Super Quiet 80 gas furnaces are available as optional accessories. A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

ACHIEVER SERIES SUPER QUIET 80 DOWNFLOW GAS FURNACE Molded Permanent Filter Motor Heat Exchanger Integrated Furnace Control Draft Inducer Motor In-Shot Burners Direct Spark Ignitor Gas Valve STANDARD EQUIPMENT Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multispeed blower with Regal Beloit X-13 Motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; on-board twinning; fused-protection (secondary), 3rd speed option for continuous fan; common heat/cool terminal. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. 2 Ruud Heating, Cooling and Water Heating All models can be converted by a qualified Ruud distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Ruud parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100% lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS MODEL NUMBERS RGLT- SERIES Input in BTU's/Hr [kw] ➁ Heating Capacity in BTU's/Hr [kw] ➀ High Altitude Input in BTU's/Hr [kw]* High Altitude Output Capacity in BTU's/Hr [kw]* Heat Ext. Static Pressure in "wc [kpa] Blower (D x W) in inches [mm] Motor H.P.-Speeds - Type [W] Cooling in CFM [L/s] @ 0.5"wc [0.12 kpa] E.S.P. (nominal) Rated E.S.P. in "wc [kpa] Temperature Rise Range in F [ C] Max Outlet Air in F [ C] Standard Filter Dimensions in inches [mm] Approx. Shipping Weight in Lbs. [kg] Return Air Cabinets (Opt.) RXGR-?? Filter Size in inches [mm] 07EAMKR 07NAMKR 75,000 [22] 60,000 [18] 67,500 [20] 53,500 [16] 0.12 [0.029] 11 x 7 [279 x 178] 1/2hp, 5spd, X-13 [373] 1200 [566] 0.5 [0.12] 30-60 [17-33] 165 [73.8] 12 x 20 [305 x 508] 105 [48] C17B (2) 12 x 16 [305 x 406] 07EBRQR 07NBRQR 75,000 [22] 60,000 [18] 67,500 [20] 53,500 [16] 0.12 [0.029] 1hp, 5spd, X-13 [746] Motor Full Load Amps 6.8 10.9 Heating Speed (factory setting) MED-HIGH MED Cooling Speed (factory setting) HIGH HIGH 2000 [944] 0.5 [0.12] 25-55 [13.9-30.6] 165 [73.8] 14 x 20 [356 x 508] 120 [54] C21B (2) 20 x 16 [508 x 406] 10EBRMR 10NBRMR 100,000 [29] 81,000 [24] 90,000 [26] 72,500 [21] 0.15 [0.037] MED-HIGH HIGH 2000 [944] 0.5 [0.12] 30-60 [17-33] 190 [87.7] 14 x 20 [356 x 508] 120 [54] C21B (2) 20 x 16 [508 x 406] 12EARMR 12NARMR 125,000 [37] 99,000 [29] 112,500 [33] 89,000 [26.1] 0.2 [0.05] 1hp, 5spd, 1hp, 5spd, X-13 [746] X-13 [746] 10.9 10.9 MED-HIGH HIGH 2000 [944] 0.5 [0.12] 35-65 [19.4-36.1] 185 [85.0] 14 x 20 [356 x 508] 140 [63] C24B (2) 24 x 16 [610 x 406] AFUE - Electronic Ignition Modules ➀ 80.0% 80.0% 80.0% 80.0% NOTES: All models are 115VAC, 60HZ, Single Phase. Gas connection size for all models is 1 /2" [12.7 mm] N.P.T. ➀ In accordance with D.O.E. test procedures. ➁ See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions. * Data references Canadian applications only. MODEL IDENTIFICATION DOWNFLOW MODELS R G L T Ruud Gas Downflow Design Furnace Series [ ] Designates Metric Conversions Electric Ignition 07E 10E 12E 07E Heating Input Designation NOx Model 07N 10N 12N Input BTU/HR 75,000 [22 kw] 100,000 [29 kw] 125,000 [37 kw] A M K R Variations Blower Heating & Cooling Fuel Type A = Std. Designation Designation R = Natural Gas, Cabinet M = 11 x 7 K = 600-1200 CFM U.S. and B = Wide [279 x 178 mm] [283 x 566 L/s] Canadian Cabinet R = Q = 1000-1600 CFM Standard [279 x 254 mm] [472 x 755 L/s] Furnace M = 1200-2000 CFM [566 x 944 L/s] Ruud Heating, Cooling and Water Heating 3

DOWNFLOW DIMENSIONS DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm] MODEL RGLT- SERIES A B C D E REDUCED CLEARANCES (IN.) [mm] NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. ➁ May be 0" [0 mm] with type B vent. ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP. WGTS. (LBS.) [kg] 07 (A) 17 1 /2 [445] 16 11 /32 [415] 12 1 /8 [308] ➀ 16 5 /8 [422] 0 3 ➁ 0 1 [25] 3 [76] 6 [152] ➂ 105 [47.6] 07 (B) 21 [533] 19 27 /32 [504] 13 7 /8 [352] ➀ 20 1 /8 [511] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 120 [54.4] 10 21 [533] 19 27 /32 [504] 13 7 /8 [352] ➀ 20 1 /8 [511] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 120 [54.4] 12 24 1 /2 [622] 23 11 /32 [593] 15 5 /8 [397] ➀ 23 5 /8 [600] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 140 [63.5] [ ] Designates Metric Conversions 4 Ruud Heating, Cooling and Water Heating

BLOWER PERFORMANCE DATA DOWNFLOW MODELS MODEL NUMBER RGLT- SERIES 07EAMKR, 07NAMKR 07EBRQR, 07NBRQR 10EBRMR, 10NBRMR 12EARMR, 12NARMR BLOWER SIZE in INCHES [mm] (D x L) 11 x 7 [279 x 178] MOTOR H.P. [W] 1/2 [373] 1 [746] 1 [746] 1 [746] NOTES: * = FACTORY HEATING SPEED = NOT TO BE USED AS HEATING SPEED MOTOR CFM [L/s] AIR DELIVERY BLOWER WIRE OUTPUT EXTERNAL STATIC PRESSURE INCHES [kpa] WATER COLUMN SPEEDS COLOR NUMBER.1 [.02].2 [.05].3 [.07].5 [.12].6 [.15].8 [2.0] LOW RED 1 916 [432] 803 [379] 669 [315] 561 [264] 504 [237] 421 [198] MED-LO YELLOW 2 993 [468] 952 [449] 910 [429] 827 [390] 793 [374] 706 [333] MED PURPLE 3 1205 [568] 1158 [546] 1124 [530] 1056 [498] 1024 [483] 950 [448] MED-HI* BLUE* *4* 1367 [645] 1333 [629] 1300 [613] 1236 [583] 1203 [567] 1140 [538] HIGH BLACK 5 1475 [696] 1444 [681] 1416 [668] 1354 [639] 1329 [627] 1264 [596] LOW RED 1 1198 [565] 1105 [521] 1093 [515] 931 [439] 901 [425] 791 [373] MED-LO YELLOW 2 1411 [665] 1358 [640] 1317 [621] 1227 [579] 1196 [564] 1093 [515] MED* PURPLE* *3* 1608 [758] 1564 [738] 1529 [721] 1451 [684] 1416 [668] 1340 [632] MED-HI BLUE 4 1918 [905] 1877 [885] 1840 [868] 1767 [834] 1706 [805] 1636 [772] HIGH BLACK 5 2122 [1001] 2083 [983] 2054 [969] 1977 [933] 1945 [918] 1874 [884] LOW RED 1 1240 [585] 1120 [528] 1073 [506] 974 [459] 917 [432] 799 [377] MED-LO YELLOW 2 1405 [663] 1364 [643] 1317 [621] 1232 [581] 1181 [557] 1083 [511] MED PURPLE 3 1600 [755] 1561 [736] 1526 [720] 1445 [682] 1403 [662] 1325 [625] MED-HI* BLUE* *4* 1903 [898] 1877 [885] 1833 [865] 1766 [833] 1711 [807] 1631 [769] HIGH BLACK 5 2072 [977] 2028 [957] 2006 [946] 1940 [915] 1908 [900] 1840 [868] LOW RED 1 1225 [578] 1073 [506] 988 [466] 864 [407] 795 [375] 697 [328] MED-LO YELLOW 2 1302 [614] 1240 [585] 1191 [562] 1074 [506] 1027 [484] 932 [439] MED PURPLE 3 1553 [733] 1503 [709] 1455 [686] 1370 [646] 1313 [619] 1237 [583] MED-HI* BLUE* *4* 1902 [897] 1859 [877] 1822 [859] 1722 [812] 1686 [795] 1602 [756] HIGH BLACK 5 2403 [1134] 2369 [1118] 2332 [1100] 2246 [1060] 2190 [1033] 2059 [971] [ ] Designates Metric Conversions Ruud Heating, Cooling and Water Heating 5

ACCESSORIES DOWNFLOW DOWNFLOW WARNING: Unit design is certified for installation on non-combustible floor. A special factory supplied combustible floor sub-base is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage and personal injury. COMBUSTIBLE FLOOR BASE DIMENSIONS COMBUSTIBLE FLOOR BASE USE WITH FURNACE SIZES A IN. [mm] B IN. [mm] C IN. [mm] RXGC-B17 RGLT-07B 18 [457] 16 3 /4 [425] 14 3 /4 [451] RXGC-B21 RGLT-10 & RGLT-07B 21 1 /2 [546] 20 1 /4 [514] 18 1 /4 [464] RXGC-B24 RGLT-12 25 [635] 23 3 /4 [603] 21 3 /4 [552] [ ] Designates Metric Conversions RXPF-F01 and F02 FOSSIL FUEL KITS are for use with Ruud Heat Pumps and Super Quiet 80 warm air furnaces. The RXPF-F02 meets TVA requirements. RXGF-CC* FILTER RACK Downflow top return mount. NOTE: Filter racks are shipped without filters. *Filters available through PROSTOCK. FOR HIGH ALTITUDES: HIGH ALTITUDE OPTION CODE: U.S. & Canada None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: U.S. & Canada None required for high altitudes. 80+ HIGH ALTITUDE INSTRUCTIONS Caution: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. High altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information. NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. GENERAL TERMS OF LIMITED WARRANTY Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Gas Heat Exchanger Limited Warranty...Twenty (20) Years Conditional Parts* (Registration Required)...Ten (10) Years *For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. 6 Ruud Heating, Cooling and Water Heating

NOTES Ruud Heating, Cooling and Water Heating 7

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. Ruud Heating, Cooling and Water Heating P.O. Box 17010, Fort Smith, AR 72917 In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. PRINTED IN U.S.A. 5-10 DC FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1