CERV Fan and Duct Sizing Information

Similar documents
SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Why ventilate? Dilute contaminants Control or aggravate humidity Comfort or lack of cooling Odors Provide oxygen

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

BEST PRACTICE RECOMMENDATIONS

The 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Glass Canopy Wall-Mount Hood

Ventilation for New Low-Rise Residential Buildings July 20, 2015

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

SAFETY AND INSTALLATION MANUAL MODEL 8100

INSTALLATION MANUAL CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) MODEL CERV-001-PARTA, CERV-001-PARTB

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

Duct Design and Installation

Fresh and clean... even when it isn't laundry time.

CHAPTER IV AIR DISTRIBUTION AND BALANCE

Low Profile Layout Guidelines

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

Series V Layout Guidelines

Laundry. Models Shown: ALW880QAW And ALE866SBW

Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings

IT S ABOUT TIME FOR FRESH AIR.

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Light commercial models

Zoning System Design Manual

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

IAQ VENTILATION SOLUTIONS

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

VHR SERIES VHR 704. Installation Manual. Heat Recovery Ventilator INSTALLATION, OPERATION AND MAINTENANCE MANUAL

IAQ VENTILATION SOLUTIONS

Residential HVAC System Design

10-year industry best core warranty. 5-year warranty on balance of unit.

1 Ventilation Checklist 1 Forced Air Systems SENTENCE (6)

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Working With DHPS and Other Variable Capacity Heat Pumps. October 05, 2017

1 Ventilation Checklist 1 Forced Air Systems SENTENCE (2)

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

PDH & Professional Training

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

Model 1750A/ 1770A Dehumidifier Installation Instructions

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Desiccant Dehumidifier

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

Heat or Energy Recovery Ventilation System

Outside Air Requirements... SOLVED!

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Ventilation Strategies in Weatherization

Mechanical Ventilation Checklists

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/Dehumidification Devices on the US Market

MECHANICAL VENTILATION

In accordance with the Department of Labor and Industry s statute , Subd. 11,

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

Limited Lifetime core warranty. 5-year warranty on balance of unit.

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Energy Recovery Ventilators

Professional Ventilators

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/ Dehumidification Devices on the US Market

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

Practical and Effective Approaches to Residential Ventilation for Production Builders

Ventilation Solutions IAQ Canada

Time-Based Scheduling of Residential Ventilation

INSTALLATION AND OPERATION MANUAL MODEL TR70\TR130\TR200\TR300 TOTAL RECOVERY FOR ALL CLIMATES (TR)

Model 8120 and 8126 Safety & Installation Instructions

Exhaust Makeup Air System What goes out, must come in

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Put the V back in HVAC

KHP 6000 KHP MODEL FOR LIGHT COMMERCIAL

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

HEPA Filtration. HEPA Series. Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

SMART DUCT SYSTEM. Caution: Do not tamper with the unit or its controls. Call a qualified service technician.

INSTALLATION AND OPERATION MANUAL 90-Series

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

INSTALLATION AND OPERATION INSTRUCTIONS

Unico Training. Class for R E Michel Salesmen

Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

DESCRIPTION OF TECHNOLOGY

Dwelling Ventilation Strategies, Including ASHRAE 62.2 ASHRAE Ventilation for Acceptable Indoor Air Quality

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

Are you Getting Your Fan Flows Right?

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Ventilation Solutions IAQ Canada

PW 150 / PW 100. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

INSTALLATION DO S AND DON TS

DIRECT DRIVE BLOWER COILS

EXHAUST FAN FLOW METER AND TRUEFLOW AIR HANDLER FLOW METER

Installation Instructions

Transcription:

CERV Fan and Duct Sizing Information Scope Duct design for distributing fresh air and exhausting house air requires two considerations: 1) Sufficiently large ducts for available fan static pressure 2) Sufficiently low air velocities to minimize noise The CERV is a balanced ventilation system designed to operate with airflow in the 100cfm to 200cfm range. Two external inline fans pull air through the CERV as shown in Figure 1 below. The supply blower pulls air through the CERV and blows into the house supply duct network. The exhaust blower pulls air through the CERV and exhausts air to the outside. Two high efficiency, variable speed, ecm fan models (Fantech model prioair 6 EC and model prioair 8 EC ) can be used with the CERV. Small homes with minimal ductwork may choose the smaller prioair 6 fan, while larger homes with more extensive ductwork and larger airflow demands would use the prioair 8 fan. The following guide can be used for determining the air flow needed for a home, planning the supply and exhaust register locations, and selecting the proper fan size. Careful consideration must be given for local building codes, which may differ from these recommendations. Build Equinox is not liable for ventilation system design. Figure 1. CERV system and fan configuration. House Air Flow Rate and Supply/Exhaust Layout Recommendations Indoor air supply and indoor return exhaust locations should be such that exhaust air is pulled from areas where moisture and odors are generated while fresh air is supplied to sleeping and living areas. This is the most favorable manner for purging polluted air from the house while replenishing fresh air. Table 1 provides guidelines for planning supply and exhaust air flows for a home. For areas listed with a range of air flows consideration should be given to the size of the room and expected utilization/occupancy. This same consideration should be used to estimate air flow for other areas not listed. Some air flow should be planned for all areas of a home within the conditioned envelope even if unutilized or storage space. For example a conditioned, but unfinished basement should have a minimal amount (5-10cfm) of both supply and exhaust air planned.

Maintaining 100-200cfm of total air flow is required for proper CERV operation. For homes with forced air systems, the CERV can be integrated into the central system ducting. Table 1. Air flow recommendations for different areas. Area Supply [cfm] Area Exhaust [cfm] Master Bedroom 40 Kitchen 30-50 Guest Bedroom 20 Master Bathroom 25-35 Office 10-20 Full Bathroom 25 Living Area 20-40 Half Bathroom 15 Dining Room 20-40 Laundry Room 10 Walk-In Closet 10 Pantry 10 Mud Room 10-15 Mechanical Room 10 Add the air flows needed for the supply side areas and separately add the air flow for the areas for the exhaust regions. The larger of the two air flow totals will be the total design air flow rate used for the house. Increase the lower air flow total (either the supply or exhaust) until it is equivalent to the larger total air flow. The prio Air 6 and prio Air 8 fan examples below illustrate fan performance at different fan speed settings. Example: A house with a Master Bedroom (40), two guest bedrooms (20+20), an office (20), a living room (30), and a dining room (20) would have a total supply air flow of 150cfm. This house has a kitchen (50), a Master Bathroom (30), one full bathroom (25), one half bathroom (15), a laundry room (10), a walk-in closet (10), a mud room (15), and a mechanical room (10) for a total exhaust air flow of 165cfm. The total design air flow rate for this house is 165cfm. The difference between 165-150=15cfm is distributed among the supply flows, so that the totaled equals 165cfm. The minimum recommended total air flow rate for a home is 100cfm. The maximum design air flow rate is 200cfm. Very large or complex homes with extended or segmented indoor area configurations should consider a second CERV system. Once the desired air flow rate is established, the distribution ducts can be designed. Good duct design practice should be used in laying out the ducting. Some important considerations: Both supply and exhaust registers should be on the ceiling or high on walls Avoid placing any registers in the floor Rigid duct is preferred to flex duct. Some flex can be used to mitigate fan noise Exhaust registers should not be placed directly over cooktops without a range hood Ducts should be in the conditioned envelope as much as possible

Fan Air Flow Rates and Available External Static Pressure Figures 2a and 2b show the available external static pressures (ESP) for the prioair 6 and prioair 8 fans. Figures 2a and 2b can be used in designing a duct layout to achieve the desired air flow rates calculated above. For each of the three fan operation conditions (6, 8 and 10 Volt for the prioair 6 EC and prioair 8 EC fan settings) there are two ESP curves. The solid line is the ESP available for the CERV including a 1 thick, 10 x20. Fresh air from outside must be filtered before entering the CERV. Locating the fresh air filter as close to the outdoor inlet in a manner that is convenient for checking and changing is strongly recommended. Any length of duct with unfiltered outdoor air will become extremely filthy. An optional (and recommended) second filter can be placed in the return duct to filter the air inside the house. The dashed line curve for each fan is the CERV with the and with the ground loop option. Example (prioair 6): A CERV application with a MERV 13 filter requiring 100cfm of air flow can use the 6 Volt speed setting with 0.2 wg ESP available for duct losses. Using an 8 Volt speed setting, the prioair 6 fan would supply 140cfm with 0.22 wg available ESP. At a 10 Volt fan speed setting, the fan can supply 180cfm at 0.23 wg of available ESP. If a heat exchanger is included, the available duct static pressure levels are decreased as shown in the figure. An application requiring 150 cfm of ventilation air flow cannot use the 6 Volt fan speed setting, but can use fan speed settings between 8 Volts and 10 Volts, depending on the static pressure of the duct design. Ventilation air flow rates above 175cfm require the maximum 10 Volt speed setting. Example (prioair 8): A CERV application with a MERV 13 filter requiring 150cfm of air flow can use the 6 Volt speed setting with 0.2 wg ESP available for duct losses. Using an 8 Volt speed setting, the prioair 8 fan would supply 185cfm with 0.20 wg available ESP. At a 10 Volt fan speed setting, the fan can supply 240cfm at 0.18 wg of available ESP. If a heat exchanger is included, the available duct static pressure levels are decreased as shown in the figure. Tables 3a/b, 4a/b, and 5a/b provide tabular values of the air flow and available ESP included in Figures 2a (prioair 6) and 2b (prioair 8). Tables 5a/5b provide duct pressure drop and air velocity for common duct sizes over the ventilation air flow ranges of most interest. The tables are based on 100 feet of equivalent straight duct length. For example, a duct run with 50 feet of straight duct and 6 elbows may be equivalent to 100 feet of straight duct. These tables are for reference only. Duct pressure drop design methods (eg, Manual D) should be used for detailed duct design. The Appendix includes two figures showing full prio Air 6 EC and prio Air 8 EC fan performance maps (static pressure versus air flow and airflow/power versus airflow) at different controller speeds.

Figure 2a. CERV air flow rates versus available external static pressure for Fantech prioair 6 EC fan at 6 volts, 8 volts and 10 volts settings. Figure 2b. CERV air flow rates versus available external static pressure for Fantech prioair 8 EC fan at 6 volts, 8 volts and 10 volts settings.

Table 2a. Fantech prioair 6 EC at 6 Volt setting airflow and available external static pressure. prio 6 6Volts prio 6 6Volts 100 0.20 0.17 110 0.14 0.09 125 0.03 Table 2b. Fantech prioair 8 EC at 6 Volt setting airflow and available external static pressure. prio 8 6Volts prio 8 6Volts 100 0.97 0.93 110 0.79 0.74 120 0.61 0.55 130 0.45 0.37 140 0.30 0.20 150 0.15 0.04 160 0.01

Table 3a. Fantech prioair 6 EC at 8 Volt setting airflow and available external static pressure. prio 6 8Volts prio 6 8Volts 100 0.53 0.50 110 0.46 0.41 125 0.35 0.28 150 0.13 0.03 160 0.04 Table 3b. Fantech prioair 8 EC at 8 Volt setting airflow and available external static pressure. prio 8 8Volts prio 8 8Volts 100 1.07 1.03 110 0.97 0.92 120 0.87 0.81 130 0.77 0.70 140 0.67 0.58 150 0.57 0.46 160 0.47 0.34 170 0.36 0.21 180 0.25 0.09 190 0.14 200 0.03

Table 4a. Fantech prioair 6 EC at 10 Volt setting airflow and available external static pressure. prio 6 10Volts prio 6 10Volts 100 0.85 0.82 110 0.79 0.74 125 0.69 0.62 150 0.50 0.39 160 0.42 0.29 180 0.24 0.07 200 0.04 Table 4b. Fantech prioair 8 EC at 10 Volt setting airflow and available external static pressure. prio 8 10Volts prio 8 10Volts 100 1.42 1.38 110 1.37 1.32 120 1.31 1.25 130 1.24 1.17 140 1.17 1.08 150 1.10 0.99 160 1.01 0.89 170 0.93 0.78 180 0.83 0.67 190 0.74 0.55 200 0.63 0.42 210 0.52 0.29 220 0.41 0.15 230 0.29 0.01 240 0.17

Tables 5a and 5b. Duct Pressure Drop and Flow Velocity Tables for 100 feet (equivalent) Duct Length Flow versus Pressure Flow 4 "duct DP 5 "duct DP 6 "duct DP 8 "duct DP 10 "duct DP "wg "wg "wg 25 0.05 0.02 0.01 50 0.18 0.06 0.02 75 0.38 0.12 0.05 100 0.21 0.09 0.02 125 0.13 0.03 150 0.18 0.04 175 0.06 200 0.08 0.02 225 0.09 0.03 250 0.11 0.04 Flow versus Velocity Flow 4 "duct DP 5 "duct DP 6 "duct DP 8 "duct DP 10 "duct DP cfm fpm fpm fpm fpm fpm 25 286 183 127 50 573 367 255 75 859 555 382 100 733 559 286 125 637 358 150 764 430 175 501 200 575 367 225 645 413 250 716 458

Appendix prio Air 6 EC Fan and prio Air 8 EC Fan Performance Maps prio Air 6 Performance Map

prio Air 8 Performance Map