Installation Instruction Venturi-Air Duct Kit. (Part No. S )

Similar documents
Interface Modules for SENTRI

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

D2E Duct Smoke Detector

Installation Smoke Detector ELQZ , GOLD

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

Instructions. Duct Mount Accessory Q Rev: 11/

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

SK-Duct Air Duct Smoke Detector

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

DUCT SMOKE DETECTORS IQ8

DNRHS Intelligent Air Duct Smoke Detector

DNRECL Eclipse Duct Smoke Detector

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

DNR-AUS Duct Smoke Detector

DNR Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

7251DH Intelligent Air Duct Smoke Detector

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

FDCW241 Radio gateway Mounting

DH100ACDCI Ionization Air Duct Smoke Detector

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

Outside Humidity and Temperature Sensor

Installation Instructions

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

INSTALLATION AM ; AMC

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

DH400 Air Duct Smoke Detector

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

Installation and Operating Instruction

INSTALLATION AND MAINTENANCE

DH500 Intelligent Air Duct Smoke Detector Housing

Installation and user manual for the BiWire / Conventional Repeater Panel

LASER ASPIRATED SMOKE DETECTOR

DNR Duct Smoke Detector

FDBZ290 Air sampling smoke detection kit

DH500ACDC Intelligent Air Duct Smoke Detector Housing

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

TrueAlarm Analog Sensing

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

FDBZ290 Air sampling smoke detection kit

Conventional Audible Visual Range

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

E-PDD Duct Smoke Detector Installation Sheet

LASER ASPIRATED SMOKE DETECTOR

Indirect gas-fired air heater

Snifter. User Manual. Distributor

Window Kit Installation Instructions

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Suits all KPF849 models

Operation and Installation Instruction

Quick Touch Pendant User Guide

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Adsorption dryer PDAD. (en) Operating instructions g [ ]

FDCL221 Line separator

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

INSTALLATION AM

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Duct and Rough Service Carbon Monoxide Sensor

FDA241, FDA221 Siemens ASD

Instructions for the BASIC BCRW Fan, Sizes General

FirePro control MANUAL

Xenex Conventional Fire Detection & Alarm System

360º Surface Mount Ceiling PIR Light Controller

Fire detection and alarm system Operating instructions

Snifter ATEX22 VERSION. User Manual. Distributor

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Application Data ! WARNING FACTORY INSTALLED SMOKE DETECTORS FOR SMALL AND MEDIUM ROOFTOP UNITS 2TO25TONS TABLE OF CONTENTS PART NUMBERS

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

Installation and Maintenance

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

DUCTSD Duct Smoke Detector

XgardIQ Duct Mounting Kit

Installation, Operating and Servicing Instructions

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

HE220, HE260 Humidifier Installation Kit

FX-PDD Duct Smoke Detector Installation Sheet

Installation and Maintenance

Installation Instructions

FDBZ290 Air sampling smoke detection kit Technical Manual

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

EDD61 & EDD91 Extractors

Quick Touch Pendant. Quick Touch Pendant. Battery

SILENT KNIGHT. IntelliKnight Smoke Detector Cleaning and Testing Instruction. Equipment Needed. Testing Equipment. Cleaning Equipment

Aspirating Smoke Detection for Duct Monitoring

Lo-Carbon Quadra SELV

Transcription:

Installation Instruction Venturi-Air Duct Kit (Part No. S4-34760)

Intended purpose This product is designed for installation on a loop circuit of a Vigilon system. Warning In order to ensure correct and safe operation of the product, all guidelines must be observed. Safety-relevant user information This manual includes all information required for the proper use of the products described. The term 'qualified personnel' in the context of the safety information included in this manual or on the product itself designates: project engineers who are familiar with the safety guidelines concerning fire alarm and extinguishing systems. trained service engineers who are familiar with the components of fire alarm and extinguishing systems and the information on their operation as included in this manual. trained installation or service personnel with the necessary qualification for carrying out repairs on fire alarm and extinguishing systems or who are authorised to operate, ground and label electrical circuits and/or safety equipment/systems. Safety warnings The following information is given in the interest of your personal safety and to prevent damage to the product described in this manual and all equipment connected to it. Safety information and warnings for the prevention of dangers putting at risk the life and health of user and maintenance personnel as well as causing damage to the equipment itself are marked by the following pictograms. Within the context of this manual, these pictograms have the following meanings: Warning sign Designates risks for man and/or machine. Non-compliance will create risks to man and/or machine. The level of risk is indicated by the word of warning: Important information on a topic or a procedure and other important information! 2 4188-971_issue 1_07/09_duct sensor kit

Table of contents 1 General...4 2 Mounting...4 2.1 Mounting the air duct kit...5 2.2 Calculation of upstream and downstream distances...6 2.3 Mounting Venturi tubes up to 600 mm...8 2.4 Mounting Venturi tubes between 600 mm and 2800 mm...9 2.5 Adapt the Venturi tube length... 10 2.6 Mounting the Venturi tube... 10 2.7 Mounting kit for circular and insulated air ducts... 11 3 Opening the enclosure... 12 3.1 Detector base wiring... 12 3.2 Install fire detector... 13 4 Final check... 14 5 Maintenance... 15 6 Specifications... 16 7 Accessories... 16 8 Loop Wiring... 17 Additional and updated Information The described features, specifications and product related information in this manual correspond to the date of issue (refer to date on the back page. 4188-971_issue 1_07/09_duct sensor kit 3

1 General The air duct kit (Part No. S4-34760) is used in combination with different Venturi tubes and special S-Quad fire detector for the surveillance of air ducts in buildings. Suitable S-Quad fire detector: Part No. Description S4-715 Optical Sensor The kit is fastened to the outside of the air duct. The Venturi tube is lead into the duct through a hole drilled for this purpose. The air streaming through the air duct is picked up by the Venturi tube and led via the deflecting unit inside the housing directly to the detector for subsequent evaluation. The inserted S-Quad fire detector is directly connected to the analog loop of the Fire Alarm System. The operation and indication of alarm and fault messages is given at the connected fire alarm panel. Subpackage 1 x Short screw to fix the Venturi tube in the enclosure 3 x Long screws to fix the air duct kits enclosure on the air duct 1x Rubber gasket (opening of enclosure Venturi tube) 1x End cap for venturi tube (inside the air duct) 2 Mounting The required mounting position is indicated by the arrow on the top of the enclosure. The alignment of the air duct kit is correct if the arrow points into the same direction as the air flow inside the duct. The arrow shaped bottom of the enclosure provides a quick info for the correct positional arrangement of the air duct kit. To avoid any damage to the devices, the supplied material in the subpackage must be used for mounting the air duct kit. If the minimum dimensions of the entry and exit paths can not be provided, care must be taken to ensure a homogenous air stream at the Venturi tube when installing the air duct detector. The direction of the air flow is not comparable with the upstream/downstream distances. This way denotes the close area of the Venturi pipe. Observe the appropriate rated pipe diameter! It may be necessary to have the air duct cross-section adapted by the company - installing the air duct - to the local dimensions in order to ensure correct operation of the air duct detector. 4 4188-971_issue 1_07/09_duct sensor kit

Dimensions 180 146 183 70 235 27 35 Fig. 1: Dimensions 2.1 Mounting the air duct kit The required mounting position is indicated by the arrow on the top of the enclosure. The arrow shaped bottom of the enclosure provides a quick info for the correct positional arrangement of the air duct kit. Mount the kit with the supplied three long screws on the duct. Only the three marked holes may be used to fasten the kit on the air duct. The kit can be mounted in different positions (top, side, bottom) on the air duct without affecting the proper operation. The arrow on the housing of the air duct kit must point into the direction of the air flow. The Venturi tube must be aligned in the middle of the ducts diameter and lead into the duct. Fig. 2: Mounting and orientation of the air duct detector 4188-971_issue 1_07/09_duct sensor kit 5

2.2 Calculation of upstream and downstream distances Air duct with circular cross-section Air duct with rectangular cross-section d h = 2 x H x B H + B d h = D H B D In order to prevent incorrect measurements the air through the duct detector should be in the same direction as the air flow through the duct. For applications with a detector mounting close to reducing dampers and regulating flaps, filter units or bends, the following minimum distances must be observed: upstream at least 3 x the nominal diameter of the air duct downstream at least 5 x the nominal diameter of the air duct Fig. 3: Air duct detector after a bend in the duct system and downstream from an air intake (Example) 6 4188-971_issue 1_07/09_duct sensor kit

Different application samples for the air duct mounting are shown in following diagrams to calculate the required air inlet/exhaust sections. MIN 3xd h MIN 5xd h MIN 3xd h MIN 5xd h Fig. 4: Exhauster Fig. 5: Reducing damper or regulating flap MIN 3xd h MIN 5xd h MIN 3xd h MIN 5xd h Fig. 6: Silencer Fig. 7: Air reservoir MIN 3xd h MIN 5xd h MIN 3xd h MIN 5xd h MIN 3xd h Fig. 8: Bend in the air duct system Fig. 9: Branch in the air duct system MIN 3xd h MIN 5xd h MIN 5xd h MIN 3xdh Return air Inlet air Fig. 10: Diameter decrease or increase in the air duct system Fig. 11: Air control unit 4188-971_issue 1_07/09_duct sensor kit 7

2.3 Mounting Venturi tubes up to 600 mm To mount the air duct (with or without the optional mounting kit Part No. S4-34760-99) with a pipe length of max. 600 mm the air duct must be drilled as shown in the figure. Mounting information! Drill a hole ( 38 mm) in the air duct and deburr the borehole. Cut the Venturi tube to the required length (refer Section 2.5 Adapt the Venturi tube length ). Hole 38 mm of air flow Air duct diameter up to 600 mm Close the end of the Venturi tube by means of the supplied sealing cap. Fig. 12: Venturi tubes up to 600 mm The immersion depth of the Venturi tube in the air duct should be 90% of the ducts diameter. Observe distance caused by the optional mounting kit if required! Refer to section 2.6 Mounting the Venturi tube! 8 4188-971_issue 1_07/09_duct sensor kit

2.4 Mounting Venturi tubes between 600 mm and 2800 mm To mount the air duct (with or without the optional mounting kit Part No. S4-34760-99) with a pipe length of more than 600 mm the air duct must be drilled at two points as shown in the figure. Mounting information! Drill a hole ( 38mm) in the air duct and deburr the borehole. Hole 38 mm of air flow Hole 50 mm air duct diameters between 600 mm and 2700 mm Because ot its lenght, the Venturi tube has to be supported in the opposite side of the air duct. upper hole 38 mm bottom hole 50 mm Cut the Venturi tube to the required length (refer Section 2.5 Adapt the Venturi tube length ). Seal the borehole of the air duct on the lower end of the Venturi tube with the supplied plastic gasket (use only Part No. S4-34760-15 / S4-760-28). Insert rubber gasket in the lower borehole of the air duct ( 50 mm). Close the end of the Venturi tube by means of the supplied sealing cap. 30 Fig. 13: Venturi tubes between 600 mm and 2800 mm The Venturi tube should not protrude by more than 30 mm above the air duct. The Venturi tube must be about 30 mm longer as the diameter of the air duct. Observe distance caused by the optional mounting kit if required! Refer to section 2.6 Mounting the Venturi tube! 4188-971_issue 1_07/09_duct sensor kit 9

2.5 Adapt the Venturi tube length The Venturi tube of the air duct kit has to be adapted to the diameter of the air duct system. Venturi tubes are available in three different lengths which can then be cut - if needed - to the required length. Diameter of the air duct Length of the Venturi tube Part No. 140 mm to 600 mm 600 mm S4-34760-06 600 mm to 1400 mm 1500 mm S4-34760-15 1400 mm to 2700 mm 2800 mm S4-34760-28 1) For systems with a tube length of more than 600 mm the Venturi tube must be about 30 mm longer as the diameter of the air duct. Fig. 14: Cutting the Venturi tube to the required length. 2.6 Mounting the Venturi tube Fit the supplied rubber gasket on the upper side of the Venturi tube (enclosure Venturi tube). Insert Venturi tube in the correct positional-rohr arrangement into the oval opening of the air duct kit. Fasten Venturi tube in the bottom of the enclosure with the supplied short screw (subpackage). The end of the Venturi tube must be terminated with the supplied end cap. Fig. 15: Mounting the Venturi tube 10 4188-971_issue 1_07/09_duct sensor kit

2.7 Mounting kit for circular and insulated air ducts The mounting kit (Part No. S4-34760-99) has to be used for mounting on insulated or circular air duct systems. The mounting kit can simply be bend to fit to the shape of the duct. Pre-punched mounting holes are provided for easy installation. Close the openings of the air duct with the supplied rubber grommets (refer to Fig.). Ventur tube hole Forming edge Fig. 16: Mounting kit for insulated and circular air ducts Mounting holes Mounting example Fig. 17: Circular air ducts Fig. 18: Insulated rectangular air duct 4188-971_issue 1_07/09_duct sensor kit 11

3 Opening the enclosure Open enclosure on the detectors side: 1. Lift plastic tab at the top carefully upwards with a small bladed srewdriver. 2. Unfix transparent cover by turning it anti clockwise and remove it. Open enclosure on the terminals side: 1. Lift plastic tab at the top carefully upwards with a small bladed srewdriver. 2. Unfix transparent cover and remove it. Fig. 19: Open enclosure (Detector side) Fig. 20: Open enclosure (terminal side ) 3.1 Detector base wiring Vigilon loop Fig. 21: Cable for loop wiring The terminal assignment as well as the connection to the Fire alarm panel is detailed in the section 8 Wiring. 12 4188-971_issue 1_07/09_duct sensor kit

3.2 Install fire detector The S-Quad (Part No. S4-715) must be aligned to the detector base and mounted by turning the detector clockwise into the base until it engages. The S-Quad is connected and powered via the loop of the Fire alarm control panel. Alarm and fault messages are transmitted via the loop to the connected Fire alarm control panel and indicated on the panel display. An activated alarm is also local indicated with the flashing red detector LED. The LED is visible for the mounted detectors in the air duct kit through the transparent cover. Fig. 22: Insert S-Quad sensor An external remote indicator may be connected if required. It is recommended to use the removal tool to insert/remove the detector from the base. Fix flow indicator (supplied Film strip) inside the cover (refer to Fig. 25). Replace cover in correct positional arrangement. Fig. 23: Flow indicator (Film strip) 4188-971_issue 1_07/09_duct sensor kit 13

4 Final check The air duct kit must be fastened correctly on the air duct by using the supplied three screws (or optional mounting kit). The ambient conditions must match the specifications of the components. The arrow head on the air duct kit must point into the direction of the air flow inside the air duct. The rubber gasket between the Venturi tube and kit is fitted as required and the tube is fastened with the appropriate screw in the air duct kit. The lower end of the Venturi tube is terminated with the supplied end cap. The cabinet must not show any signs of damage. Additional vents into the cabinet are not permitted. If the air flow against the Venturi tube is present the flow indicator oscillates. The oscillating speed depends on the air flow speed inside the air duct. The detector base is correctly wired and all terminal screws are tighten. The cover is properly engaged at the fixing points to ensure the IP protection rating. 14 4188-971_issue 1_07/09_duct sensor kit

5 Maintenance If the air duct kit or the Vigilon panel is undergoing service and maintenance work observe ensure appropriate action is taken to prevent unwanted alarms. To test the air duct detector enabled the test operation mode for this detector zone at the panel. Fig. 24: Test alarm activation of the detector 1. Pull the seal of the service opening carefully outwards and turn it aside. 2. Remove spraying nozzle from test gas can. 3. Press the valve of the test gas can towards the inspection hole. 4. Apply test gas in the inside of the chamber by briefly pressing the test gas can 5. Wait for alarm activation of the detector (red LED flashes, as the case indication at the panel). 6. If the detector is not activated apply again some test gas in frequent intervals. 7. Close opening with the seal after testing. Detector zones which are in test mode will not cause a test fire condition! 4188-971_issue 1_07/09_duct sensor kit 15

6 Specifications Air duct detector housing (Part No. S4-34760) Terminals : 1.5 mm² max. Air velocity : 1 m/s to 20 m/s Ambient temperature : -10 C to +60 C Storage temperature : -15 C to +65 C Protection class : IP 54 Housing : ABS plastic Colour : grey (with transparent cover) Weight : approx. 800g (without detector / detector base) Dimensions (W x H x D) : 180 x 235 x 183 (mm) S-Quad (Part No. S4-715) Operating voltage : 35 V to 41 V Alarm indicator : red LED, flashing Air velocity range : 0 to 5.000 ft/min. ft/min. Ambient temperature : -20 C to +50 C Temperature, storage : -25 C to +70 C Ambient humidity : 95% relative humidity (non-condensing) IP rating : IP 43 (with base + option) Housing : ABS plastic Colour : white (similar to RAL 9010) Weight : approx. 110 g Dimensions (with base) : Ø 117 mm, H = 62 mm Detector specification : EN 54-7, CEA 4021 EN 54-17 (section 4.8) data : Vmax 42V Vnom 40V Vmin 24V VSO max 16V VSO min 8V IC max 0.4A IS max 1A IL max 20uA ZC max 0.1ohms Venturi tube Part No. S4-34760-06 S4-34760-15 S4-34760-28 Length (mm) 600 1500 2800 Weight (Kg) 0,2 0,6 1,2 Material aluminium 7 Accessories Description Part No. Air duct kit S4-34760 Venturi tube 600 mm S4-34760-06 Venturi tube 1500 mm S4-34760-15 Venturi tube 2800 mm S4-34760-28 Mounting kit for circular and insulated air ducts S4-34760-99 S-Quad Optical Sensor S4-715 16 4188-971_issue 1_07/09_duct sensor kit

L2 02 L1 01 S4-34760_Venturi-Air Duct Kit 8 Loop Wiring Duct Sensor 1 - L1 2-0V 3 - L2 4-0V 5 - EM 6 - C 7 - Earth 8 - Earth 12 34 56 78 100m max. + - Unmonitored LED output Earth to metal box C3 IN4 OUT5 S-Quad Note: The 0V terminals in the terminal plate are electrically connected together. L2 0V L1 0V Manual call point C3 IN4 OUT5 S-Quad LOOP CIRCUIT 1 L2 02 L1 01 3 S device (2-way) L1 0V L2 0V Term inal Card LOOP n PANEL Fig. 25: Loop Wiring 4188-971_issue 1_07/09_duct sensor kit 17

Fig. 26: Vigilon loop wiring 18 4188-971_issue 1_07/09_duct sensor kit

Page intentionally left blank. 4188-971_issue 1_07/09_duct sensor kit 19

At the end of their useful life, the packaging, product and batteries should be disposed of via a suitable recycling centre and in accordance with national or local legislation. WEEE Directive: At the end of their useful life, the packaging, product and batteries should be disposed of via a suitable recycling centre. Do not dispose of with your normal household waste. Do not burn. Gent by Honeywell reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions of changes. Gent by Honeywell 140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN Tel : 0116 2462 000 20 4188-971_issue 1_07/09_duct sensor kit