ONSITE WASTEWATER EFFLUENT UV DISINFECTION DEVICE MODEL 120 UV UNIT PART #P8888

Similar documents
SALCOR INC. P. O. Box 1090, Fallbrook, CA Phone: Fax:

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

Ozone + UV Sanitation

CURE ZONE 2 (#A )

UV I UNIT030W / UV I UNIT055W

UV Lamp and Quartz Sleeve Replacement/Maintenance

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

CURE ZONE (#A )

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

SLT-Series Installation and maintenance instructions

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

PCO/UV N-Duct Model. Owner s Guide

OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

ASSEMBLY AND DRESSING INSTRUCTIONS

Purelight XD UV Light Wand. User s Guide

Murano Shower Cabin Installation Instruction

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

Document No B1 February Atlantic Ultraviolet Corporation

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Instruction Sheet DANGER

Instruction Sheet DANGER

Ultraviolet Water Sterilizer Installation and Maintenance Manual

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Operation Manual for Eco-Logic Pond & Lake Restoration System

Decon Scrubber Owner s Manual

Massachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI)

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2

Document No A3 Revised February Atlantic Ultraviolet Corporation

Features Decor Star PL-004-SS

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

Open Kjeldahl Apparatus INSTRUCTION MANUAL

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

Decor Star 1. Decor Star PL-037-SS

Features Decor Star PL-004-SS

Cleaning Instructions for Symbol IP54 Devices

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

SludgeHammer. Owner s Manual. Model S-400/600. The latest advance in wastewater treatment. NSF/ANSI Standard #40. nature called. we answered.

Ultraviolet Disinfection Unit Installation and Owners Manual

OSCAR-II Installation Manual, Idaho. July 2018

Duke Manufacturing Co.

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

Features Luxier SP21-SS

Ultraviolet (UV) Water Treatment System

Features Luxier SP21-SS

Technical Bulletin IG018 Quanex Building Products

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

1020 Industrial Drive, Orlinda, TN fax

AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Hi-Temp Bath Installation and Operation Manual

ENVIRONMENTAL HEALTH AND SAFETY. Power Washing Guidelines

WEDECO Quadron UV System

Features Luxier SP26-GS

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

Package Content. Decor Star 1 2. PL-011-GS Rev. A

Innovative Lighting R-Series Vertical Refrigeration

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

INSTALLATION & MAINTENANCE

READ THIS MANUAL PLEASE KEEP FOR PERMANENT REFERENCE. Part No , Revised

Experiment #6 Photolithography: Microprocessing Technology Fabrication of the microstructures with SPR photoresist

Model # VWK-2 INSTRUCTION MANUAL

S-Series Installation and maintenance instructions

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

ORALITE Microprismatic Garment Tapes

Model CWA200 Owner s Manual

DUST FREE CARBON Whole House Air Purifier

c=) MODEL: NSD10037 PACKING DIAGRAM UMP AND (3) SHIMS ' IGHTS AND TRANSFORMER. LOWER COLUMN ESERVOIR BASE CASTING POLYFOA

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

O W N E R S MANUAL ROUGE

Care and maintenance instructions for products supplied by VEKSØ A/S

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

Guidelines to Minimize Phytophthora Contamination in Restoration Projects

SHQ15 A, 25 A HEATER CONTROLLERS

Installation and Operation Manual

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

A measured step forward

OWNER S MANUAL MODEL BW4B SLICER WARMER

AQUA LOGIC S CORONA SERIES UV STERILIZERS

RIGA ZUHNE

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N

1 General Description

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

SYSTEM BASIC WHIRLPOOLS

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

QIAcube HT Unpacking and Installation Instructions

SuperOX TM Oxygen Sensor U.S. Patent No. 5,635,044

Innovative Lighting R-Series Overhead LED Conversion Kits

PZ1, PZ3 & PZ6 Installation Guide

Document No A9 Revised August Atlantic Ultraviolet Corporation

Transcription:

ONSITE WASTEWATER EFFLUENT UV DISINFECTION DEVICE MODEL 120 UV UNIT PART #P8888 I. CLEARSTREAM MODEL 120 UV UNIT 1. Clearstream manufacturers a UV disinfection unit for wastewater treatment applications. UV is a proven method to protect the health and environment from pathogens in wastewater because: It is extremely effective at eradicating viruses and bacteria It is very energy efficient 2. Clearstream s 120 UV Unit has been tested numerous times by third party testing sites in the effluent stream of Clearstream s ATU s. 3. An optional benefit of Clearstream s 120 UV Unit is when used with the RMSYS Monitoring System maintenance personnel can be notified electronically (i.e. cell phone, computer, ipad) of UV system failure. II. INSTALLATION INSTRUCTIONS 1. First, unpack the unit and check for any damage in shipping. There are seven (7) subassemblies that comprise the UV system, which are: a. Disinfection chamber 3 ABS with 4 inlet and 4 outlet hubs. b. Disinfection subassembly bulb support frame packed inside the disinfection chamber. c. PVC handle to remove frame. d. UV lamp packed inside the PVC handle. e. Riser pipe 4 ABS with a ¾ PVC nipple at one end. The PVC handle with UV lamp are packed inside. f. Electrical subassembly junction box with pre-wired alarm board, electronic ballast and UV lamp power cable. g. Two (2) 4 Schedule 40 ABS pipe couplings. Please NOTE: Inspect the unit upon receipt and report any damage to the shipper (i.e. UPS, FedEx, etc.) Clearstream is not responsible for damage in shipment. If a part is defective, then see Clearstream Warranty. III. IV. CONTRACTOR SUPPLIED MATERIAL LIST: 1. ABS cement (also a multipurpose cement if you will be bonding to PVC pipe) 2. Silicone sealant 3. Teflon tape 4. Isopropyl alcohol 5. Power and control wiring (a schematic wiring diagram is included with this package) INSTALLATION METHODS: 1. UV assembly in the ground couple the 4 inlet side of the 120 UV UNIT to the 4 pipe exiting the Clearstream Treatment System, then couple the 4 outlet side to the 4 pipe going to the method of treated effluent disposal. 2. UV assembly in the pump tank couple the 4 inlet side of the 120 UV UNIT to the 4 inlet pipe entering the pump tank. Please NOTE: The electrical junction box if above grade should always be protected from mowing machines, etc., and from flooding if installed in a pump tank or meter vault.

V. MAINTENANCE AND SERVICE 1. The Clearstream UV Disinfectant Device Unit is designed to provide long service life. It is recommended that the UV lamp be replaced every one (1) to two (2) years to insure proper disinfection. To replace the lamp: a. Power off the dedicated UV circuit breaker located in the system electrical panel that supplies power to the UV System. b. For personnel protection put on gloves and eye protection before removing the electrical junction box and ballast from the UV disinfection chamber and carefully set it aside. c. Using the power line connected to the UV lamp as a lifting device, lift the lamp up out of the disinfection assembly. d. Disconnect the four (4) pin connector attaching the power line to the UV lamp. e. Connect the new lamp to the four (4) pin connector and again using the power line as a lowering device completely lower the new lamp into the UV subassembly. f. Ensure that the remaining power line stored inside the 4 riser pipe. g. Then insert the plastic section on the back side of the control center enclosure into the top of the 4 riser pipe. h. Power on the dedicated UV circuit breaker located in the system electrical panel. The new bulb should illuminate. 2. It is recommended that the disinfection subassembly be removed and serviced a minimum of once (1) per year to insure proper effluent disinfection. To clean the disinfection subassembly, use a soft sponge and mild detergent then rinse with clean water. For the difficult stains on the lamp use isopropyl alcohol on a soft cloth to remove fingerprints and other attached films.