GRADESHIFT UDL INSTRUCTION MANUAL 3.1 PSTN CONNECTION

Similar documents
Installation Manual. for D2300 DualCom GPRS

GRADESHIFT UDL INSTRUCTION MANUAL

Installation Manual for D1100 / D1101 DigiCom

DigiPlus INSTRUCTION MANUAL

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

ADE Gen4. Speech Dialler Engineering Information. Description. Features

GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

Sentient. Downloader Manual D4854

MK9 series CarePhone. Installers Mauual

GradeShift G2r/G3r INSTallaTIoN MaNUal

secure signalling systems for I&HAS

EURO 46 V10 User Manual

IRIS Touch Firmware Enhancements and Additions from Version to Version

WEBWA al Y arm 2 sig 4 nall2 in 4

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

NESS 5000 SERIES DIALLER

600 Range Dialer Installation Manual. Version 1.0

EURO 46 User Manual. For use with EURO 46 (version 9.1 or above) RINS1531-2

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

EURO User Manual. For use with EURO 76, MSX 162, MSX 280 software: Version 9.1 or above RINS1527-2

Lifeline 400 user guide q6 18/2/04 10:56 am Page 2. Lifeline 400. installation and user guide. Part Number D B

Euro ONE. RENDER ALARMS Your security, above all else. User Manual. t: f:

User Manual. PIEZO WARNING The Wireless Alarm contains a loud siren, please be aware of this after an activation

ATS2000/3000/4000/4500 Control Panel. Programming guide

IRIS Touch Engineering Manual. Version 1.2

rvm4c Installation Guide Remote Video Module

User/Installation Guide

Page ii. Cooper Security Ltd. 2012

The following equipment is included in your Tunstall Home box t :

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with:

Memcom Emergency Telephone

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

Installation, Maintenance and Operation Manual

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

AT60 AUTO DIALLER User Guide

SC-F3G User Manual 1.0

Computer Room Guard Model VM Manual and Installation Instructions

PERMACONN PM1030 Includes DI300. Installation Manual

Monitoring solutions

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Quick Alert Remote (QA216R)

Wireless Alarm System Extended User Guide. Alarm Panel Time 10:09 c

User/Installation Guide

AV-3008 LED, SOL AV-3008 GSM (for LED keypads)

ZSC100 Gas Detection and Alarm System Controller

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

Installation and user guide

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Basic Installation Manual

For business, corporate and public sector security. Protected premises, protected network

M550 and M600. Installation Instructions

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Changes for EN50131 BS8243 PD6662

Product brochure. Protect your world. Choose an alarm signalling provider recognised for quality and reliability. Never compromise.

IRIS Touch Engineering Manual. Version 1.2

Intruder Alarm Handbook

Fusion Alarm System USER GUIDE

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

EC-P Zone Intruder Alarm System

PTE0705 Electric Fence Monitor

EVO192 v3.0 Fire and Burglary What s New

M800, M800iD Plus, M1000 and M3000. User's Guide

Tunstall Vi+ User Guide

LEITRONIC AG Swiss Security Systems EasyAlarm ELEVATOR

Please read and retain these instructions for future reference v002: 23/01/18

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

T4000 Security Communicator

Fratech Multipath-IP

BURGLAR ALARM PANEL BS-468

TECHNICAL. Voice Alarm Dialing or Store Caster Announcements from up to Eight Inputs. K-2000-DVA Multi-Input Voice Dialer/Announcer

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

USER & INSTALLATION GUIDE

RVRC Training Manual Fast Trace Installer Menu

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Configuration and Operation Manual for the Unipos

EURO 46 APP. User Manual. Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2

Ref.1067/032 Ref.1067/042

SECURIT 700L PLUS ENGINEERING MANUAL

Memcom + Emergency Telephone

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

SafeLine SL6 THE NEXT GENERATION OF

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

Your Lifeline Vi+ home unit. Your MyAmie pendant

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

P2267 NETWORK INTERFACE

Security GSM Alarm System

English. Doro CareIP Mobile. User Guide

THIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS

USER & INSTALLATION GUIDE

Transcription:

GRADESHIFT UDL INSTRUCTION MANUAL 3.1 PSTN CONNECTION

GradeShift UDL Instruction Manual 3.1 PSTN Connection Telephone Line Connection There are several different types of telephone line available from different service providers. GradeShift requires an analogue telephone line connection. Earth Loop Calling or Earth Calling types of analogue telephone line cannot be used. GradeShift cannot be directly connected to any type of digital telephone line. Earth connection In accordance with EN regulations GradeShift does not require an Earth connection at the telephone line terminals. Analogue PSTN Telephone Line The analogue PSTN is a communication network where the line from the exchange equipment and the service supplied to the subscriber is analogue, i.e. not digital. A telephone line is always terminated at the user s premises by an NTP (Network Termination Point) which is provided by the Telecoms Service Provider. This is a socket or connection where the user s equipment can be connected. Some NTPs provide a socket and terminals for connection. In many cases, the NTP operates using power supplied from the exchange equipment via the telephone line. Figure 1 Analogue PSTN Telephone Line

PSTN Line Connection Options GradeShift s PSTN connection requires an analogue telephone line (also called a POTS line). Analogue telephone lines often carry ADSL (Broadband) signals as well. Refer to ADSL later in this section. Connecting other telecoms equipment in parallel to the analogue telephone line used by GradeShift can stop the unit sending polling calls and alarm calls to an Alarm Receiving Centre. Parallel connection should not be used for GradeShift when it is used in a security system. There are several ways that a GradeShift may be connected to a PSTN telephone line particularly when other equipment needs to share the same telephone line. Some require that your Telecom Service Provider supplies particular line features. Some require GradeShift NVM programming options. The highest security PSTN line for GradeShift (Recommended): A PSTN line supplied as outgoing calls only, i.e. Incoming Ringing Barred, AND the PSTN line is ex-directory, AND the PSTN line goes to the GradeShift ONLY. Other equipment can be connected to the GradeShift A1 & B1 terminals (i.e. series connection) to make outgoing calls only. See Figure 3. The next best security option for a PSTN line (Recommended): A PSTN line supplied with the 3-way calling feature, AND the GradeShift NVM is programmed for 3-way calling, AND the PSTN line goes to the GradeShift ONLY. Other equipment can be connected to the GradeShift A1 & B1 terminals (i.e. series connection) for incoming and outgoing calls. See Figure 3. The no security option ( NOT Recommended ) A PSTN line supplied without outgoing calls only or the 3-way calling feature. This option cannot cancel or hold incoming calls and these will inhibit the GradeShift from making a telephone call to the Alarm Receiving Centre. Parallel Connection ( Do NOT use ) The GradeShift A & B terminals connect to the telephone line, and other equipment connects directly to the same telephone line. See Fig 2. This connection option can not cancel or hold incoming or outgoing calls to other telephone equipment on the same line, and these will inhibit GradeShift from making polling & alarm calls to the ARC. Figure 2

PSTN Line Connection (GradeShift ALONE on line) Your Telecom Service Provider should be asked to supply and fit an analogue line and an NTP with terminals near the alarm system. The alarm installer should then follow steps 1 & 2 below. Series Connection (GradeShift & OTHER EQUIPMENT on line) Your Telecom Service Provider should be asked to supply and fit an analogue line and an NTP with terminals near the alarm system. The alarm installer should then follow steps 1 to 3 below. 1. Connect 2 wires to the GradeShift s PSTN A & B terminals. 2. Connect the other end of the wires to the NTP connections for the incoming telephone line, marked A & B, or 2 & 5. 3. If the PSTN line used by GradeShift is shared with other customer apparatus (e.g. telephone, fax or answer machine) connect the GradeShift s terminals marked A1 and B1 to a new PSTN Master Socket. The customer may then plug their phone, fax etc, into that socket. See Fig 3. A PSTN Master Socket type LJU2/4A is suitable and has screw terminals for connection. These can be obtained from many electrical distributors including: CPC Part Number: TE 05285 Maplin Part Number: FT48C RS Part Number: 472-534

Where the GradeShift s telephone line is shared with the customer s phone/fax etc. you can avoid GradeShift s polling calls interfering with the customer s calls. Setup a programmable output on the panel to operate when the panel is set/unset. (When unset, the customer is likely to be in the premises and using the phone.) Connect this panel output to GradeShift s pin triggering terminal 4. In this way, GradeShift will know when the telephone line is likely to be used and can avoid making polling calls that clash with the customer s calls. PABX (Private Automatic Branch Exchange) A PABX is a telephone exchange in one business or building (where a dial 9 is needed for an outside line). It connects to one or more outside telephone lines and has two or more extensions within the business or building. See Figure 4. GradeShift may be connected to one of the outside telephone lines where they are the analogue PSTN type. See Figure 4. The extensions within the building may be analogue or digital. Where an extension is analogue, a normal phone or fax machine may be connected. GradeShift may be connected to this analogue extension. See Figure 4. Where the PABX is mains powered and it is not battery backed-up then the extension line to the GradeShift may fail in the event of a mains failure. This may make this type of telephone connection unsuitable for GradeShift in alarm applications. Where the extension is a digital line then a special feature phone is usually required, provided by the manufacturer of the PABX equipment. GradeShift cannot be directly connected to any type of digital telephone line.

Figure 4 PABX with connection to Analogue PSTN Line ADSL (Asynchronous Digital Subscriber Line) or Broadband When an analogue PSTN telephone line also carries ADSL (Broadband) signals and it is used by a security system e.g. GradeShift, then an ADSL (Broadband) filter MUST be used. A filter is used to separate the analogue telephone signals from the Broadband digital data signals because the phone or security system may be disrupted or completely inhibited if Broadband digital data is allowed into them from the telephone line. The CSL CS0720 Broadband Filter is designed specifically for use with security systems. This item meets all of the requirements of the British and European telephone and security standards. See Figure 5. Other types of filter and plug-in filters should not be used for Series Connection of a security system to the telephone line. The installer must ensure that the Broadband Filter is fitted in the wiring between the NTP and the GradeShift s A&B terminals. Other items connected to the GradeShift s A1 and B1 terminals must be analogue equipment, i.e. phone, fax. Note that a computer or broadband modem will not work if connected here because the Broadband Filter will stop the entire broadband signal from reaching the GradeShift. Figure 5

Q. Why is a Broadband Filter necessary? A. When ADSL (Broadband) digital data is supplied on a normal PSTN telephone line then an ADSL (Broadband) Filter must be fitted between that telephone line and each item of non digital equipment because: 1). The operation of non digital equipment may be disrupted or completely inhibited if ADSL (Broadband) digital data is allowed into it from the telephone line. 2). The operation of the ADSL (Broadband) equipment may be disrupted or completely inhibited by the connection of unfiltered non digital equipment to the telephone line. Non digital equipment means anything that can be used on a normal analogue PSTN telephone line, e.g. a Phone, Fax, GradeShift, Control Panel Digi-Modem.