E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

Similar documents
Mobile CWA Detection and Identification. Innovation with Integrity. Mobile Mass Spectrometer MM2 CBRNE

RAID-S2. Innovation with Integrity. Stationary Rapid Alarm and Identification Device. Defence CBRNE

RAID-M 100. Innovation with Integrity. Hand-held Chemical Agent Monitor. Defence CBRNE

DE-tector. Innovation with Integrity. Narcotics & Explosives Detector CBRNE

Standoff CWA/TIC Detection. Innovation with Integrity. Toxic Gas/Vapour Threat Mitigation RAPIDplus CBRNE

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

Explosives Trace Detection. Innovation with Integrity. Explosives Threat Mitigation: Bruker RoadRunner. Safety & Security

Chemical Threat Detection. Innovation with Integrity. Integrated CWA/TIC detection and identification: Bruker RAID-S2plus CBRNE

Product Overview. Innovation with Integrity. Bruker: The Gold Standard in CBRNE Detection CBRNE

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Explosives Trace Detection. Innovation with Integrity. Explosives Threat Mitigation: Bruker DE-tector flex. Safety & Security

Chemical/Radiological Threat Detection. Innovation with Integrity. Combined NC Detection: Bruker RAID-XP Series CBRNE

Mobile Platforms Capability Brochure. Innovation with Integrity. The Gold Standard in CBRNE Detection Solutions. CBRNE Detection

Application Note CBRNE Stand-Off Detection of Toxic Industrial Chemicals in Industrial Complexes Using RAPIDplus

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS

Technical specifications of FT-IR Spectrometer

This document is a preview generated by EVS

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

CALIDUS tm the Modular micro Gas Chromatograph

PHOENIXL 300 New Standards in Leak Testing. Technical information

Datalogging as standard

SCION 436-GC. Dimensions and Weights

intrinsically safe detector for hydrocarbon gases

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Hiden HPR-20 QIC EGA for evolved gas analysis in TGA-MS

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

On-site Detection of Siloxanes and other unwanted VOCs in Landfill/Sewage/Biogas using Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS)

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Chemtron Science Laboratories Pvt. Ltd.

Operate the Mutli-Gas Monitor PID

Battery-operated, hand-held alarm and measuring instruments for radiation protection

Perkin Elmer Clarus 500 Gas Chromatograph

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

An Introduction to Mass Spectrometry

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Homeland Security Task Force Meeting October 10, 2012

VM-3000 Mercury Vapor Monitor

Dräger X-am 7000 Multi-Gas Detection

OPEN PATH DETECTION OF ACROLEIN LEAKS

THE EMILI SERIES: MAKING EVERY LIQUID TRANSPARENT

ELD500 PRECISION LEAK DETECTOR

Hiden QGA Quantitative Gas Analysis System

Gas Chromatography (GC-342)

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Mercury Vapor Monitor VM-3000

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

EasyLog Data Logger Series

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Process Gas Chromatograph

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

VM-3000 Mercury Vapor Monitor

EasyLog Data Logger Series

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

BenchTOF. The next generation of time-of-flight mass spectrometers for GC and GC GC

Recent Improvements in Process GC Instrumentation

AGILENT VS SERIES LEAK DETECTORS

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating

Accessories, interfaces, sensors and complete solutions.

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

GC Injectors. GC Injectors

ProStar 325 UV-Vis Detector

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Rosemount 1500XA Process Gas Chromatograph

NEW - S.I.S. Newsletter. NEW! - Visit our New Machining website at:

Vision: To provide world-class detection technologies and services enabling integrated solutions to protect people, assets and communities.

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Coal Pile Fire Monitoring System

Nanotechnology-Based Gas Sensors

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Series 9000 Total Hydrocarbon Analyzer

Software-Aided Operation of Modern Industrial Leak Detectors

Rosemount 1500XA Process Gas Chromatograph

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Dräger Polytron 7000 Fixed gas detector

safe and your operations compliant

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

More Precision. indusensor // Linear inductive displacement sensors

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

get mass. without massive work. [ 3100 MASS DETECTOR ]

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

SIMRAD GD10PE IR GAS DETECTOR

Battery Powered Digital Mass Flow Meters for Gases

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Updated Leak Detection & Location Technology

Battery Powered Digital Mass Flow Meters for Gases

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

TYPES AND APPROPRIATE INJECTORS

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

Transcription:

E²M Enhanced Environmental Mass Spectrometer Innovation with Integrity Safety & Security

Enhanced GC/MS System The E 2 M is the successor to the highly successful and proven GC/MS system EM 640. It represents Bruker s continuing commitment to the advancement of existing instruments. The instrument can be mounted on vehicles and operated while the vehicle is underway. The E 2 M uses 24 VDC which means that it can use the vehicle power supply. The E 2 M is able to identify organic chemicals from any medium (soil, water, air) within 20 minutes via complementary sampling techniques. Specifications and performance are not limited to a selected portion of chemicals. New libraries can be created and used by the customer. The detection limit for volatile organic compounds is from low ppb to the low ppm range depending on the analytical procedure, e.g. adsorbent enrichment (low ppb range) or on-line monitoring (approx. 1 ppm range) from ambient air. Training and operation is reduced to the lowest possible level whilst the reliability is increased. E 2 M with GC and mounting The E 2 M is a mobile, compact, lightweight and rugged GC/MS system for fast, reliable onsite identification and quantification of organic substances in soil, air, water and from surfaces. Quadropul - heart of the E 2 M

System Components and Accessories E2M gas chromatograph with transport case Quadrupole Mass Spectrometer Inlet: Thermodesorber / Injector / SPME programmable up to 240 C Carrier gas: ambient air Capillary: various polarities, 5...20 m GC temperature range: 3 ramps up to 240 C Sampling case Air/surface probe E2M base unit with transport case Fast on-site sample preparation Air samples Solid/Soil samples Liquid Samples (Purge&Trap) Wipe Tests Brief SOP s for sampling methods Direct measurement of air and surface contaminations Ruggedized notebook For use in harsh environments Injector kit / SPME kit Split-injection of liquid samples Solid Phase Micro Extraction

Control Software Main menu from E2M operator software The E 2 M software includes all standard MS acquisition methods Full spectra acquisition; 1...520 da Single ion monitoring (SIM) Easy to use graphical user interface Adaptation to existing fire brigades SOP HAZMAT database linkage The E 2 M is supported by new Software Modules for instrument control and data acquisition. The E 2 M Control (Advanced User) is used to set all parameters of the instrument and therefore to create new applications. The software tools are compatible with standard WINDOWS systems and standard PCs. The data transfer is provided by an Ethernet-100 interface. Air monitoring with E2M control software E2M Analysis / E2M Control: Air- and Surface monitoring of TICs up to 20 substances simultaneously up to 8 characteristic ions per substance E 2 M Analysis-GC Mode: Recording chromatograms of complex substance mixtures and identification of the substances via MS spectra libraries (NIST, TICLib or customer specific libraries) The E 2 M Analysis (Operator level) supports an easy and uncomplicated operation of the system for already prepared methods. GC run in E2M Analysis Software Both software tools include the fully automated data evaluation based on the NIST spectra library (National Institute of Standards and Technology), and the Bruker TICLib (Toxic Industrial Compounds) or a customer specific libraries.

Typical Applications of the E2M Environmental protection Fast and reliable on-site detection and identification of hazardous chemicals from soil, water and air within minutes. Mobile on-site analysis E2M is designed for vehicle integration and can operate while the vehicle is underway. Vehicles can be cars, vans, trucks as well as ships, helicopters and other aircrafts. Event monitoring First responders Protection of major events such as sport, concerts, folk festivals etc. Identification of released chemicals leads to corect timely decisions and reduces the number of potential casualties. Fast investigation of chemical hazards, drugs and explosives by the Fire Brigades, Police and other Emergency and Blue Light Services. Homeland defence Fast detection and clear identification of released chemicals in critical infrastructures (subways, airports, railway stations, public buildings etc) by first responders (police, custom, fire brigades, analytical task forces).

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL 06-2012, CBRN #255614 Technical Specifications Dimensions (LxWxH) 436 x 368 x 442 mm Weight 37,7 kg Volume 58 l Ionisation Electron impact, 70 ev Filament Dual Mass stability 0.2 da at all allowed operating conditions Detector Off axis CEM, automatic tuning Vacuum system Ion getter pump < 10-6 mbar (20 l/s, N2), noiseless Inlet Membrane, heated Mass range 1 520 da Scan rate 7200 da/s with a resolution of 0.1 da Calibration PFTBA, automatic tuning Selected Ion Monitoring (SIM) Up to 20 substances simultaneously MTBF 1500 hours, 2 hours-in 3-monthsoperation for vacuum-hold MTBS 2 years External power supply 24 V DC (18... 32V) < 250 W @ 20 C Humidity 95% @ 60 C Certifications CE IP42 IEC 61000 (EMC) IEC 60068-2 and 2-2 CISPR 16-1, 16-2 (radiated emissions) 0...+50 C (Temperature) IEC 60068-2-6, -2-27 (Shock/Vibration) Data handling Separate standard PC, WINDOWS based operating systems Connected via Ethernet-100 Interface Three level software for result visualization, expert Bruker Detection Division of Bruker Daltonik GmbH Zweigniederlassung Leipzig Leipzig Germany Phone +49 (341) 2431-30 Fax +49 (341) 2431-404 detection@bruker.com www.bruker.com/cbrne Bruker Detection Division of Bruker Daltonics Ltd. Coventry United Kingdom Phone +44 (2476) 855-200 Fax +44 (2476) 465-317 detection@bruker.com Bruker Detection Corp. Billerica, MA USA Phone +1 (978) 663-3660 Fax +1 (978) 667-5993 detection@bruker.com