CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

Similar documents
Enteral Pump Instructions for Use To Assemble When the low

Table of Contents. kangaroo 924. English. General Information... Operating Procedures... Battery... Beginning Administration...

Administration of AMBISOME Using the GemStar Pump

Operating Manual. Kangaroo TM. 924 Enteral Feeding Pump with Pole Clamp

Syringe Pump. User Manual

USER GUIDE. Software Version 1.11

Ozone + UV Sanitation

User s Manual. i-warm Fluid Warmer

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

INSTRUCTIONS FOR OPERATION AND CARE OF

Cool Flow & CoolOR PERSONAL COOLING SYSTEMS POLAR PRODUCTS polarproducts.com

Alaris Syringe Module v9

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

OPERATING INSTRUCTIONS. Hearing Instrument Restoration System.

Important Safeguards. Save these instructions for future reference. (continued on next page)

Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

PERSONAL Ultrasonic Cool Mist Humidifier

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

P.N ELECTRIC KETTLE User Manual Series MODEL BVSTKT308

MedReady Set-up, Helpful Hints, and Solutions for Special Needs

Clinician Information


MODEL 7000 SUCTION UNIT

Automatic Phone-Out Home Monitoring Systems

Alaris Syringe Module v9

IW-25-2 Dehumidifier Installation & Operations. Manual

Model S-530 Coin Sorter / Value Counter Operating Manual

ADORABLE Ultrasonic Cool Mist Humidifier

Manual Feed Slot Opening. Wastebin. Credit Card Casters

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

Model 7500EB Portable Eyewash with Heater

Operator s Manual DigiPump LP8 Infusion Pump - Digicare Biomedical Technology Inc CONTENTS. A. About this manual...2

BLENDTEC DIVISION OF K-TEC, INC 1206 SOUTH 1680 WEST OREM, UTAH USA TELEPHONE FACSIMILE

Multiple use Digital Thermometer With 7 Day Memory

User Instruction Manual

PREASSEMBLED SURGICAL WASH SET FOR DIDECO COMPACT ADVANCED Instructions for Use Product Designations: WS-55C, WS-125C, WS-175C, WS-225C DESCRIPTION:

4L Instant Water Boiler Instructions for Use

Infrared Portable Space Heater

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Earn Reward Points register your new

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

BLAST-IT-ALL BUMPER BLASTER

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

When using electrical appliances, especially when children are present, basic safety precautions should always be taken, including the following:

Stand Fan. English. Owner s Guide. Model F R

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Operator s Manual. IP-100 Immersion Probe Cooler

Installation & Operating Instructions

Suits all KPF849 models

English. Your Model Number is: HD1500 IMPORTANT

DANGER Any appliance is electrically. WARNING To reduce the risk of IMPORTANT SAFETY INSTRUCTIONS

SINGLE SPEED SYRINGE PUMP

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

Please read and retain these instructions for future reference v001: 19/09/18. DC 6V, 4 x D size batteries, not included

Installation Instructions EFS Hand Washing Station

COOLFLOW IRRIGATION PUMP USER MANUAL

SPECIFICATIONS PART NAME

Ultrasonic Humidifier

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA

P.N User Manual STAINLESS STEEL ELECTRIC KETTLE 5964/5965 Series MODELS

Portable Air-conditioner

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Lock-N-Load Sonic Cleaner 2L. Instruction Manual

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

Operator's Manual. PCP October 2017

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R. For How-To videos, go to

WARNING THE MAGNUM PRESSURE BLAST CABINET


USER MANUAL SAVE THESE INSTRUCTIONS

PREASSEMBLED SURGICAL WASH SET FOR DIDECO ELECTA

I N ST. MODEL 2912PS AUTOMATIC SLICER... with Portion Scale 701 S. RIDGE AVENUE TROY, OHIO

DANGER Any appliance is electrically READ ALL INSTRUCTIONS BEFORE USING

CLEAr view TOASTER. unprocess your food. Visit us at bydash.com. Instruction manual & recipe IDEAS MODEL DVTS501. page title bydash.

2001 Smith Eastern Corporation

POWERSHRED 425Ci/425i/485Ci/485i

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Forehead Infrared Thermometer

16 OUTDOOR MISTING FAN

User Manual. 40 Tower Fan MODEL: WFTR40W

CA5000 Liquid CO 2 Freezer Backup System

DEHUMIDIFIER INSTRUCTION MANUAL

MACH 5-20 oz POPCORN MACHINE OPERATION MANUAL

Margo Moo TM and Digger Dog TM Steam Inhaler Guidebook

Water Tech TM. Handheld underwater pool & spa cleaner Use and Care Manual POOL BLASTER CATFISH PPV

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Description of the CADD-Prizm VIP Pump

OP40R 40cm Remote Control Pedestal Fan

Proven Quality Made in Germany

Care and Use Instructions

Sapphire TM. Bring Home The Future Of Infusion Care. Ambulatory Infusion System. > Intuitive, easy-to-use touch screen design

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Transcription:

OPERATOR S MANUAL

CONTENTS I. INTRODUCTION... pg 2 FRONT HOUSING PARTS LOCATION (Figure 1)... pg 4 REAR HOUSING PARTS LOCATION (Figure 2)... pg 5 II. CONTROL PANEL... pg 6 KEYPAD (Figure 3)... pg 6 III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9 IV. INDICATORS AND ALARMS... pg 10 V. MAINTENANCE... pg 11 VI. TROUBLESHOOTING GUIDE... pg 12 VII. SPECIFICATIONS... pg 14 VIII. SERVICE... pg 15 IX. ACCESSORIES... pg 15 X. WARRANTY... pg 16 1

I. INTRODUCTION The EnteralEZ is a timesaving, user-friendly enteral feeding pump that can be used for the delivery of enteral nutrition formulas. The pump is simple to program, and many of its functions can be activated with a single touch. Reliable and accurate, the EnteralEZ is designed to give the user easy access to its many useful features. Anti-free flow alarm feature identifies potentially harmful bolus of enteral formula. Prime feature allows convenient set priming at the touch of a button. VOLUCHECK keeps a record of accumulated amount of formula delivered over several feedings. Large clear display windows can be read from a distance. Clear button clears all displays. Audible and visible alarms are readily differentiated. User is alerted to low battery, empty formula container, occluded tubing, dose complete, and in event of formula free-flow. Smooth plastic case is easily cleaned with mild soap. Simple self-test allows operator to check major functions before use. 2

INTRODUCTION (Continued) Built in pole clamp allows patient mobility. Memory is not erased by power interruption. Dose can be set in 1ml increments up to 2000ml, then in 5ml increments up to 9999ml. Alarm volume is adjustable, except for free-flow alarm, which is always at full volume for safety. Programming directions are printed directly on pump. Special holder on back of pump conveniently stores Disposable Set Cap and helps prevent possible contamination. 3

FRONT HOUSING PARTS LOCATION Drop Sensor Area Drip Chamber Guide Tube Guide Slot ZEVEX EnteralEZ Drip Chamber Bracket ON TM OFF Rotor Low Bat Bat Occ Emp Dose Comp Figure 1 4

CAUTION TO REDUCE THE RISK OF ELECTICAL SHOCK, DO NOT REMOVE BACK COVER. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. REAR HOUSING PARTS LOCATION Carrying Handle ALARM VOLUME CONTROL Cord Wrap Pole Clamp Knob CAP HOLDER Holder for Disposable Set Cap Power Cord Alarm Port Figure 2 5

II. CONTROL PANEL DISPLAYS RATE: Indicates rate of delivery (in ml/hr). DOSE: Indicates dose limit setting (in ml). VOLUME: Indicates formula volume delivered since this display's memory was last cleared (in ml). ZEVEX ON OFF EnteralEZ TM BUTTONS ON: Turns pump on. OFF: Turns pump off; power to battery charger remains ON if power cord is plugged in. MORE: Increases delivery rate or dose limit. LESS: Decreases delivery rate or dose limit. DOSE: Displays dose limit. Sets dose limit when used with MORE or LESS. VOLUCHECK : Displays the accumulated delivered volume (Acc) since memory was last cleared. RUN/STOP PRIME*: Puts pump in run or hold mode, or if held for three seconds, pump flashes PRInnE in display and primes until button is released. CLEAR: Clears VOLUME, DOSE, RATE or total accumulated volume when pressed in sequences described in Section III (OPERAT- ING INSTRUCTIONS). Low Bat Bat Occ Emp Dose Comp Figure 3 6

III. OPERATING INSTRUCTIONS 1. Plug power cord into a 120 VAC, 60 Hz three-wire grounded outlet. 2. Press ON. Alarm sounds briefly. VOLUME display flashes. 3. Press MORE or LESS until desired infusion rate is displayed. 4. Press DOSE then MORE or LESS while dos is displayed until desired dose is displayed. If dose limit is not set, pump will run until container is empty or pump is stopped. 5. Close Roller Clamp on tubing, if so equipped. 6. Fill feeding bag to desired level and close cap. 7. Hang bag on IV pole approximately 26-30 above pump using the bag hanger. 8. Place base of Drip Chamber inside Drip Chamber Bracket. 9. Bring tube counter-clockwise around Rotor. Seat in-line occluder or retainer into the Bracket. Press tubing into Tube Guide Slot. 10. Open Roller Clamp, if so equipped, and remove Disposable Set Cap. Cap can be placed in Cap Holder on back of pump. Expel air from disposable set by allowing liquid to flow through tube. Tubing can be conveniently primed by pressing RUN/STOP PRIME* key for three seconds and holding until tubing is primed. Tubing may also be manually primed before loading into pump by opening roller clamp, if so equipped, or grasp the in-line occluder by the base and tilt approximately 45 degrees to the left or right while gently pulling down. Hold this position until air is expelled from the tube. If needed, gently squeeze bag at the same time to start fluid flow. Close Roller Clamp once tubing is primed, if so equipped, and replace set. 11. Firmly insert red Stepped Enteral Adapter of disposable set into feeding tube. 12. Open Roller Clamp, if so equipped. 7 Base In-line occluder 1. Press tubing into tubing guide slot. 2. Insert and fully seat in-line occluder flange into pump bracket

OPERATING INSTRUCTIONS (Continued) 13. Press RUN/STOP PRIME* to begin feeding. 14. To change infusion rate, press RUN/STOP PRIME* to stop pump. Press MORE or LESS to make necessary adjustment. Delivery rate is retained in memory. If MORE or LESS is pressed without stopping pump, alarm will sound and pump will continue operating. To view dose while pump is operating, press DOSE; Rotor will momentarily pause while programmed dose is displayed. 15. To change dose, press RUN/STOP PRIME* to stop pump. Press DOSE then MORE or LESS to make necessary adjustment. Dose is retained in memory. If MORE or LESS is pressed without stopping pump, alarm will sound and pump will continue running. 16. To clear rate, dose or accumulated volume, press RUN/STOP PRIME* to stop pump. CLEAR will only function when pump has been stopped. Pump will beep twice, pause, and beep twice again as display clears. If CLEAR is pressed while pump is operating, alarm will sound and pump will continue to run. To reset VOLUME to 0ml/hr, press and hold CLEAR for two beeps. To reset DOSE to 0ml, press DOSE, then within three seconds press and hold CLEAR for two beeps. To reset total accumulated volume delivered to 0ml, press VOLUCHECK, then within three seconds press and hold CLEAR for two beeps. To clear all memories except VOLUCHECK, and reset infusion rate to 1ml/hr, press and hold clear for four beeps. ALL will show in left (RATE) window. 17. To view total accumulated volume delivered, press RUN/STOP PRIME* to stop pump, then press VOLUCHECK. Press RUN/STOP PRIME* again to restart the pump. 18. To turn pump off at any time press OFF. WARNING: Close Roller Clamp, if so equipped, before tubing is removed from pump to prevent formula free-flow. 8

LOADING DISPOSABLE SET Roller Clamp (If so equipped) Drip Chamber ZEVEX EnteralEZ Drip Chamber Bracket ON OFF TM In-line Occluder or retainer Low Bat Bat Occ Emp Dose Comp Loading Direction Rotor Disposable Set Cap Stepped Enteral Adapter Figure 4 9

IV. INDICATORS AND ALARMS LOW BAT: When operating on battery, light begins flashing and pump audibly alarms approximately 15 minutes before battery runs down and pump stops. After 15 minutes, light will flash, alarm will sound, and pump will stop. When LOW BAT light comes on, plug pump into an AC outlet to continue normal feeding while recharging battery. It is advisable to not run battery down completely. NOTE: Pump will not begin operating if Low Bat indicator is flashing. BAT: When operating on battery, light is on. Pump should be plugged into an AC outlet whenever possible. OCC/EMP: When pump is running, light turns on if: Feeding container is empty. Occlusion has stopped delivery. Pump is left on STOP for more than 2-½ minutes. Drip Chamber is improperly loaded. DOSE COMP: Pump stops delivering, light flashes and audible alarm sounds four times when amount of formula delivered reaches selected dose. Alarm is repeated every five minutes until action is taken. FrE FLO: Whenever power is on, dual-tone alarm sounds if drop sensor detects uncontrolled flow, or if drop sensor is blocked for more than six seconds. Possible causes include Drip Chamber is over-filled, Drip Chamber walls are coated with formula and/or Drop Sensor Area needs to be cleaned. Alarm sounds at maximum, regardless of volume setting, and display flashes FrE FLO. 10

V. MAINTENANCE CLEANING AND DISINFECTING PUMP Always disconnect pump from the AC outlet before cleaning to avoid electrical shock. Do not autoclave. Do not immerse pump in cleaning solutions or water. Do not use disinfectants containing phenol. Prolonged exposure to alcohol, household detergents, or strong cleaners may damage pump housing. Using a cloth or sponge, clean pump housing and Rotor with warm soapy water. Clean Drop Sensor Area with soft cotton swabs dipped in isopropyl alcohol. When a pump has come in contact with infectious disease, clean as above using isopropyl alcohol or a disinfectant safe for plastics, instead of soapy water. SELF TEST To test major functions: Press ON. Press and hold MORE and LESS buttons simultaneously for 3 seconds. RATE and VOLUME displays should show a row of eight's, and Rotor should turn. Press MORE, LESS, DOSE, CLEAR, VOLUCHECK and RUN/STOP PRIME* buttons to test each key. All alarm indicators should light, alarm should sound, and Rotor should stop momentarily. Pump will display software version. Place a pencil or your finger in Drip Chamber Guide, Rotor should stop, alarm should activate and alarm indicators should light when obstruction is removed. Turn pump off to cancel test. If pump fails to respond as described, pump requires service (see Section VIII. SERVICE for instructions). 11

VI. TROUBLESHOOTING GUIDE The EnteralEZ Enteral Feeding Pump is a reliable electromechanical device. As with any electromechanical device, problems may occur. The following tips may help you to correct minor problems. SITUATION LOW BAT alarms. After approximately 15 minutes, pump stops, displays flash & alarm beeps. OCC/EMP alarms. Pump stops, alarm beeps, displays flash. DOSE COMP alarms. Displays flash. POSSIBLE CAUSES Battery charge is below performance level. Roller Clamp is closed. Container is empty. Occlusion is restricting flow. Drip Chamber not properly placed in pump; drops not being sensed. Pump is on STOP more than 2-1/2 minutes. Pump has delivered selected dose. SOLUTIONS Plug cord into AC outlet. Open Roller Clamp. Replace or refill. Correct occlusion: kinked tubing in disposable set; clogged feeding tube; or blocked container. Reposition properly. Press RUN/STOP PRIME* to resume feeding, or turn pump off. Change dose limit, if desired. Press RUN/STOP PRIME*. Pump will run until new dose is completed again. - or - Press OFF. Feeding completed. 12

TROUBLESHOOTING GUIDE (Continued) SITUATION FrE FLO alarm beeps. Displays flash. POSSIBLE CAUSES Pump set is dislodged. Tubing off Rotor. Drop sensor blocked due to formula on Drip Chamber walls. Drop sensor blocked due to overfilled Drip Chamber. SOLUTIONS Close Roller Clamp. Check set placement on Rotor. Open Roller Clamp and restart pump. Replace disposable set. Close Roller Clamp. Disconnect disposable set from patient's feeding tube. Remove disposable set from pump, open Roller Clamp and invert Drip Chamber to purge formula from Drip Chamber. Close Roller Clamp. Reload disposable set and open Roller Clamp. Rate change alarm beeps. Pump does not stop. Drop sensors need cleaning. MORE, LESS, CLEAR or VOLUCHECK will only work when pump has stopped. Clean Drop Sensor Area with cotton swab dipped in isopropyl alcohol. Press RUN/STOP PRIME* once. Check accumulated volume or change rate, as desired. Press RUN/STOP PRIME* again to restart. 13

VII. SPECIFICATIONS TYPE OF DEVICE: PUMP MECHANISM: OPERATING RATE RANGE: DOSE LIMIT: DOSE ACCURACY: OCCLUSION PRESSURE: BATTERY: DIMENSIONS: WEIGHT: CASE MATERIAL: POWER REQUIREMENT: OPERATING TEMPERATURE: OPERATING HUMIDITY: STORAGE TEMPERATURE: STORAGE HUMIDITY: Volumetric enteral feeding pump Rotary peristaltic 1-295 ml/hour in 1ml/hour increments 1-2000 ml in 1 ml increments, 2000-9999 ml in 5 ml increments +/- 10% of selected flow rate Does not exceed 15 psi Sealed lead acid like car battery Rechargeable Automatically recharges when connected to an AC outlet Recharge time is 12 hours from complete discharge to full recharge Operating time is approximately six hours at 125 ml/hr with a full charge 7.4"H x 9.0"W x 5.1"D (19cm x 23cm x 13cm) 5.6 pounds (2.54 kilograms) Flame retardant plastic 120 VAC,.25A, 60 Hz 50 F to 104 F (10 C to 40 C) 30 to 75% non-condensing -40 F to 158 F (-40 C to 70 C) 10 to 95% non-condensing 14

VIII. SERVICE For service, contact enteral products customer service at: ZEVEX Incorporated 4314 ZEVEX Park Lane Salt Lake City, Utah 84123 www.zevex.com Tel: (801) 264-1001 Fax: (801) 264-1051 Toll-Free in USA: (800) 970-2337 IX. ACCESSORIES ZEVEX offers several disposable sets which are compatible with the EnteralEZ : Order No. Description Units/Case LG010 LifeGuard Non-vented spike with attached pump set 30 LG500 LifeGuard 500ml Bag with attached pump set 30 LG200 LifeGuard 1200ml Bag with attached pump set 30 ZEVEX also offers a complete line of enteral nutrition delivery products including the EnteraLite Ambulatory Enteral Feeding Pump and related accessories. 15

X. WARRANTY Solely for the benefit of the original buyer, ZEVEX Incorporated ("ZEVEX") warrants all new EnteralEZ products of its manufacture to be free from defects in material and workmanship, and will replace or repair, F.O.B. at its factory in Salt Lake City, Utah or other location designated by ZEVEX, any EnteralEZ products to be returned to it within twenty-four (24) months of original purchase by the buyer. Such repair or replacement shall be free of charge. ZEVEX warrants to the original buyer, all repaired or replaced products to be free from defects in material and workmanship and will replace or repair such products F.O.B., at is factory in Salt Lake City, Utah, or other location designated by ZEVEX. Such repair or replacement shall carry a warranty of ninety (90) days from the date of repair or replacement or the balance of the new product warranty as described above, whichever is greater. This Warranty applies to all EnteralEZ products manufactured by ZEVEX and is the ONLY WARRANTY GIVEN FOR THE SALE OF PRODUCTS OR SERVICES. NO WARRANTIES IMPLIED IN LAW, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. ZEVEX WILL BE LIABLE, IN ANY EVENT, ONLY FOR THE PURCHASE PRICE OF THE DEFECTIVE PRODUCT, BUT NOT FOR ANY CONSEQUENTIAL DAMAGES. This Warranty may not be modified, amended or otherwise changed, except by a written document properly executed by a corporate officer of ZEVEX. 16

OPERATOR S MANUAL 4314 ZEVEX PARK LANE SALT LAKE CITY, UT 84123, USA TEL: (801) 264-1001 TOLL-FREE IN USA: 1 (800) 970-2337 FAX: (801) 264-1051 2004 ZEVEX INCORPORATED MADE IN USA www.zevex.com PART NO. LS-0541-1/B 1202K